The information in this document is subject to modification without
any prior notice.
Some models are available in dedicated countries only.
VINTEC offers no guarantee for our wine cellar if it is being used for any purpose other
than that for which it was specifically designed. VINTEC cannot be held responsible for
any error in this manual. VINTEC is not responsible or liable for any spoilage or damage
to wines or any other contents incidental or consequential to possible defects of the wine
cellar. Warranty applies to the wine cellar only and not to the content of the wine cellar.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
R600A WARNINGS
The following models use small quantity of R600A (iso-butane) flammable refrigerant:
For your safety please observe the following recommendations :
This appliance contains a small quantity of R600A refrigerant which is
environmentally friendly, but flammable. It does not damage the ozone layer, nor
does it increase the greenhouse effect.
During transportation and installation, ensure that the tubing of the refrigerant
circuit is not damaged.
Avoid using or manipulating sharp objects near by the appliances.
Leaking refrigerant can ignite and may damage the eyes.
In the event any damage does occur, avoid exposure to open fires and any device
which creates a spark. Disconnect the appliance from the mains power.
Thoroughly ventilate the room in which the appliance is located for several
minutes.
Notify Customer Service for necessary action and advice.
1
code: VIM 201301/S/01
The room for installing the appliance must be at least 1 cubic metre per 8 grams of
refrigerant. The refrigerant quantity contained in this appliance is listed above in
grams; it is also noted on the Rating Plate of the appliance.
It is hazardous for anyone other than an Authorised Service Person to carry out
servicing or repairs to this appliance.
– WARNING: Keep ventilation openings in the appliance enclosure or in the built-in
structure clear of obstruction.
– WARNING: Do not use mechanical devices or other means to accelerate the defrosting
process, other than those recommended by the manufacturer.
– WARNING: Do not damage the refrigerant circuit.
– WARNING: Do not use electrical appliances inside the compartments.
– WARNING: In Queensland Australia, the authorized person must hold a Gas Work
Authorisation for hydrocarbon refrigerants, before carrying out servicing or repairs which
involve the removal of covers.
The environment and personal safety must be considered when disposing of this appliance.
Please ensure the appliance is taken to a recycle center for safe recycling. DO NOT
dispose of the appliance in land fill as the insulation and refrigerant gas contained in these
appliances are flammable.
Allow 24 hours before switching on the wine cellar. During this time we recommend
that you leave the door open to clear any residual odors.
BEFORE LOADING & PLUGGING IN THE WINE CELLAR
Important: All models without front venting (air opening) are strictly for free standing
only. (See technical chart)
Recommendations:
The location you have selected for your wine cellar should:
- be unencumbered and well ventilated;
- be well away from any heat source and direct sunlight;
- not be too damp (laundry, pantry, bathroom etc.);
- have a flat floor;
- have a standard and reliable electricity supply (standard socket to country standards,
linked to the ground), it is NOT recommended to use a multi-socket or extension lead;
- have a surge protector fitted to the electrical outlet;
- away from the microwave oven. Certain microwave ovens do not have wave interference
shield. When placed within 1 meter vicinity of the wine cabinet, they may affect the
operation of the wine cabinet.
2
code: VIM 201301/S/01
Notes:
- V30 models are for free standing ONLY.
- V40& V26 models are built-in type as per the drawings thereafter.
The wine cellar should be placed where the ambient temperature is between 5ºC to 35ºC.
If the ambient temperature is above or below this range, the performance of the unit may
be affected. Placing your unit in extreme cold or hot conditions may cause interior
temperatures to fluctuate. The ideal range of temperature may not be reached. (See
Climate Class at the end of this manual)
Grounding instructions
The wine cellar must be grounded in case of an electrical short circuit. Grounding reduces
the risk of electrical shock. The wine cellar is equipped with a power cord having a
grounding wire and plug. The wine cellar plug must be plugged into a properly affixed and
grounded electrical outlet.
Note: In locations where there is frequent lightning, it is advisable to use surge
protectors.
Improper use of the grounding plug can result in the risk of electric shock. Consult a
qualified electrician or service person if the grounding instructions are not completely
understood.
If the supply cord is damaged, it must be replace by a qualified person in order to avoid
electrical hazard.
INSTALLING YOUR WINE CELLAR
Unpack and remove all of the protection and adhesive strips from the packaging around
and inside the wine cellar.
The wine cellar must be positioned such that the plug is accessible. Release the power
cord. Move your wine cellar to its final location. The wine cellar should be installed in a
suitable place where the compressor will not be subject to physical contact.
Leveling your wine cellar: Wine cellar must be leveled BEFORE
loading your wines.
Your Vintec wine cellar is equipped with 4 adjustable feet to facilitate easy leveling.
VINTEC recommends that you tighten the back feet to the maximum and adjust the front
feet to level the wine cellar.
3
code: VIM 201301/S/01
Fixing the Back spacer:
Compressor run appliances require proper ventilation for proper and longer usage. Your
Vintec wine cellar is supplied with a back spacer. Affix the back spacer at the back of the
cellar for air circulation and heat evacuation.
IMPORTANT - THIS SPACER MUST BE ATTACHED TO THE UNIT BEFORE
THE INSTALLATION, FOR VENTILATION PURPOSE. FAILURE TO DO SO VOIDS THE
WARRANTY
INSTALLATION INSTRUCTIONS FOR BUILT IN WINE CELLARS:
(UNDERBENCH OR IN COLUMN) FRONT VENTING WINE CELLARS ONLY.
V30 models are free standing only. Any built in voids the warranty
4
code: VIM 201301/S/01
1. Vintec “Built in” wine cellars are front venting but are not designed to be fully
integrated behind a joinery door.
2. Vintec “Built in” wine cellars require 10mm clearance on both sides and top, 30mm
clearance at the rear (Back spacer is provided),to facilitate installation, removal, servicing
and ventilation.
3. Vintec “Built in” wine cellars draw air from the rear and expels through the metal grid
under the door at the front. If a kick board is to be placed in front of the wine cellar’s grid
another one must be fitted into the kick board with a minimum air flow allowance of
150cm2.
4. Vintec “Built in” wine cellars have a power switch located on the control panel so
power point location is not critical.
5. The wine cellar requires a standard 240 volt/10 amp power point. (Or according to
different countries specifications).
6. The power cord is 1.9m in length and is fixed on the right side at the back when looking
from front of cabinet.
7. As with most appliances of today, the wine cellar has sensitive electronic components
which are susceptible to damage through lightning and electricity supply faults. It is
therefore advised to use a power surge protector to avoid problems of this nature.
8 Air vent within the joinery must be provided for Vintec built in wine cellars (front
venting)
In Hot climate zone, an air vent or grid, with a minimum ventilation size of 200mm x
40mm MUST be cut out at the rear top of the back partitioning or at the top of either side
of the partitioning, allowing cool fresh air full access to flow into the 30mm gap located at
the rear of the cabinet.
This air vent or grid must not be opened on the same side as other appliances such as
ovens or an area that is sealed and without access to fresh cool air.Failing to comply with
the above specifications could result in WARRANTY void.
5
code: VIM 201301/S/01
INSTALLATION DRAWINGS FOR BUILT IN WINE CELLARS: (UNDERBENCH
OR IN COLUMN) FRONT VENTING WINE CELLARS ONLY
.
30 mm *
This applies to all V40SG/DG
BK&S3 models
.
* only 10mm requires for V26 etc.
6
code: VIM 201301/S/01
Dimensional drawings:
V26’s
V40’s (30mm recess plinth)
7
code: VIM 201301/S/01
V40’s (85mm recess plinth)
V40 S3/BK models
TURNING ON YOUR WINE CELLAR
Plug in and switch on the cellar by pressing on the power button for a few seconds.
When you use the wine cellar for the first time (or restart the wine cellar after having it
shut off for a long time), there will be a few degrees variance between the temperature you
have selected and the one indicated on the LED readout. This is normal and it is due to
the length of the activation time. Once the wine cellar is running for a few hours
everything will stabilize.
Important: If the unit is unplugged, power is lost, or turned off, wait 3 to 5 minutes
before restarting the unit. The wine cellar will not start if you attempt to restart before
this time delay.
8
code: VIM 201301/S/01
Loading...
+ 20 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.