Viking VCWH53048AG, VWH548481CS, VCWH53648KA, VCWH54848PG, VCWH53648BF INSTALLATION INSTRUCTIONS

...
Installation
Professional Indoor & Outdoor Hoods
VWH53012 / VWH53612
VWH53048 / VWH53648 / VWH54248
VWH54848 / VWH56048
VCWH53048 / VCWH53648 / VCWH54248
VCWH54848 / VCWH56048
VCIH53608 / VCIH54208 / VCIH55408 / VCIH56608
VWHO3678 / VWHO4878 / VWHO6078 (Canadian Outdoor models not applicable)
Table of Contents
Warnings & Important Information VWH/CVWH 10” H/12”H. Wall Hoods w/Standard Ventilator 30”, & 36”
Dimensions & Specifications_______________________________________________________________ 5 Clearance Dimensions_____________________________________________________________________ 6 Interior Ventilator Dimensions ____________________________________________________________ 7
VWH/CVWH 18”H. 24”Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”
Dimensions & Specifications ______________________________________________________________8 Clearance Dimensions ______________________________________________________________________9 Interior Ventilator Dimensions _____________________________________________________________10 Exterior Ventilator Dimensions ___________________________________________________________11
VWHO/CVWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”
Dimensions & Specifications ______________________________________________________________12 Clearance Dimensions ____________________________________________________________________13
VCWH/CVCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, & 60”
Dimensions & Specifications ______________________________________________________________14 Clearance Dimensions ____________________________________________________________________15 Interior Ventilator Dimensions ___________________________________________________________16 Exterior Ventilator Dimensions ___________________________________________________________17
VCIH/CVCIH Chimney Island Hoods 36”, 42”, 54”, & 66”
Dimensions & Specifications ______________________________________________________________18 Clearance Dimensions ____________________________________________________________________19 Interior Ventilator Dimensions ___________________________________________________________20 Exterior Ventilator Dimensions ___________________________________________________________21
VBCV/CVBCV Wall Custom Ventilator System
Dimensions & Specifications ______________________________________________________________22 Installing Hood Canopy___________________________________________________________________23 Clearance Dimensions ____________________________________________________________________24
VBCV Ventilator Dimensions ______________________________________________________________25 Planning Information _________________________________________________________________________27 Installation Procedures
Installation (VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator)___________________28
Duct Cover Option (VWH/CVWH 12”H. Wall Hoods w/Standard Ventilator)__________________30
Installation (VWH/CVWH 12”H. Wall Hoods w/Recirculating Kit) ____________________________30
Installation (VWH/CVWH 18”H. Wall & VCWH Chimney Wall Hoods) ________________________33
Duct Cover Option (VWH/CVWH 18”H. Wall Hoods) ________________________________________34
Duct Cover Option (VCWH/CVCWH Chimney Wall Hoods) __________________________________35
Installation (VCIH Island Hoods)___________________________________________________________36 Service & Registration ________________________________________________________________________38 Wiring Diagram ______________________________________________________________________________39
_________________________________________________________________ 3-
4
2
IMPORTANT–Please Read and Follow!
NOTE:
If installing hood with warming shelf panel, install
warming shelf panel first.
WA R NI N G
IMPORTANT – PLEASE READ AND FOLLOW
• Before beginning, please read these instructions completely
and carefully.
• Do not remove permanently affixed labels, warnings, or
plates from the product. This may void the warranty.
• Please observe all local and national codes and ordinances.
If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition.
• Damp environment approved models should be installed in
a covered non-enclosed area and should be protected from the elements as much as possible.
• The installer should leave these instructions with the
consumer who should retain for local inspector’s use and for future reference.
• Check with a qualified and trained installer or local codes
for makeup air requirement, if any.
This hood is for residential installation only and is not designed for installation over a commercial product. Make sure power is off at the main circuit breaker or fuse box before making connections. To avoid risk of fire, electric shock, or injury to persons, turn off the electricity to the hood from the power supply before servicing or cleaning. Viking hoods are equipped with variable speed control blowers. These units will not function with a single speed ventilator. All Viking Range ventilator kits are designed specifically for use with Viking Range hoods. Use of any non­Viking Range ventilator kit will void the hood warranty.
Viking hoods are equipped with the variable speed controls for blowers. These units will not function with a single speed ventilator. All Viking ventilator kits are designed specifically for use with Viking hoods. Use of any non-Viking ventilator kit will void the hood warranty.
READ AND SAVE THESE INSTRUCTIONS
To reduce the risk of fire, electric shock, or injury to persons, observe the following:
• Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
• Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire­rated construction.
2. Sufficient air is needed for proper combustion and exhausting of gases through the flute (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
3. When cutting of drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
4. Ducted fans mustalways be vented to the outdoors.
5. WARNING!: To reduce risk of fire, use only metal ductwork
6. CAUTION!: To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings, or into attics, crawl spaces, or garages.
7. CAUTION!: To Reduce the Risk of Fire and Electric Shock, Install this rangehood only with remote blower models manufactured by Viking, model numbers – DEV900/DEV1200, VEV900, VIL1200, OR DEV1500 or integral blowers manufactured by Viking, model numbers – VINV300/600/1200, or DIL1200. NOTE – Please refer inside for specific canopy/blower combinations.
3
IMPORTANT–Please Read and Follow!
WA R NI N G
To reduce the risk of injury to persons in the event of a rangetop grease fire, observe the following. (Based on “Kitchen FiresafetyTips,” published by NFPA.)
1. SMOTHER FLAMES with a close fitted lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN. You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels a violent steam explosion will result.
4. Use an extinguisher ONLY if
• You know it is a Class ABC extinguisher, and you already know how to operate it.
• The fire is small and contained in the area where it started.
• The fire department is being called.
• You can fight the fire with your back to an exit.
C A U T IO N
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
WA R NI N G
This appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
WA R NI N G
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS
Rangehoods must be installed with the ventilators that are specified on their carton indicating suitability with this model. Other ventilators cannot be substituted.
4
2
1”
(5
3
.
3
c
m
)
A
1
0”
(
2
5. 4 c
m
)
1
2
(
3
0
.5
cm
)
A (Hood width) 30”W. 29-7/8“ (76.2 cm) 36”W. 35-7/8” (91.1 cm)
5
(12
.7
c
m
)
2
1”
(53
.3
c
m
)
A
1
2 ”
(30.
5
cm)
A (Hood width) 30”W. 29-7/8“ (76.2 cm) 36”W. 35-7/8” (91.1 cm)
5
(
1
2.7 c
m
)
1
2 ”
(30.
5
cm)
Dimensions & Specifications
(VWH 10”H./12”H. Wall Hoods w/Standard Ventilator 30”, & 36”)
NOTE: Optional duct cover sold separately.
VWH/CVWH 10”H./12”H. Wall Hoods
Description 30” 36”
Duct cover width
Duct cover depth
Duct cover height
Number of lights
Number of filters
Heat lamps
Interior ventilator kit
Interior duct size*
Interior—Maximum amps
* Disregard when using recirculating kits. 460 CFM blower is shipped with hood.
w/Standard Ventilator
29-7/8” (75.9 cm) 35-7/8” (91.1 cm)
12” (30.5 cm)
12” (30.5 cm)
2
2
N/A
460 CFM Standard
7” (17.8 cm)
5.6 A
5
* NOTE: When installing with a 24”high-shelf, the 27” (68.6 cm) max. dimensions must be used.
2
4
"
m
i
n
.
(
6
1
.
0
c
m
)
t
o
2
7
"
m
a
x
.
*
(
6
8
.
6
c
m
)
6
0
"
mi
n
.
(
1
5
2
.
4
c
m
)
t
o
6
3
"
m
a
x
.
(
1
6
0
.
0
c
m
)
3
6
"
(
9
1
.
4
c
m
)
Clearance Dimensions
(VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator)
6
A
B
C
D
18”
(4.6 cm)
3-7/8”
(9.8 cm)
3-4”
(1.9 cm)
7” (17.8 cm) dia. duct location
Electrical hookup
1/2”
(1.3 cm)
4”
(10.2 cm)
3-1/2”
(8.9 cm)
A 24”W. 23-7/8” (60.6 cm) 30”W. 29-7/8” (75.9 cm) 36”W. 35-7/8” (91.1 cm)
B 24”W. 5-1/4” (13.3 cm) 30”W. 8-1/4” (20.9 cm) 36”W. 11-1/4” (28.6 cm)
C 24”W. 11-15/16” (30.3 cm) 30”W. 14-15/16” (37.9 cm) 36”W. 17-15/16” (45.6 cm)
D 24”W. 5/8” (1.6 cm) 30”W. 3-5/8” (9.2 cm) 36”W. 6-5/8” (16.8 cm)
Interior Ventilator Dimensions
(VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator)
Top View
460 CFM Interior Ventilator Installation
7
2
4
"
(
6
1
.
0
c
m
)
A
1
8
"
(
4
5
.
7
c
m
)
1
2
"
(
3
0
.
5
c
m
)
6
"
(
1
5
.
2
c
m
)
A 30" W 29-7/8" (76.2 cm) 36" W 35-7/8" (91.1 cm) 42" W 41-7/8" (106.4 cm) 48" W 47-7/8" (121.6 cm) 60" W 59-7/8" (152.1 cm)
Dimensions & Specifications
(VWH/CVWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”)
NOTE: Optional duct cover sold separately.
Duct cover width
Duct cover depth
Duct cover height
Number of lights
Number of filters
Heat lamps
Interior ventilator kits
Exterior ventilator kits
In-line ventilator kits
Interior duct size
Exterior duct size
Interior—Maximum amps
Exterior—Maximum amps
In-Line—Maximum amps
Total Watts
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max
duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; A ll products must be hard wired with 2-wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
VWH/CVWH 18”H. Wall Hoods
Description 30” 36” 42” 48” 60”
29-7/8”
(75.9 cm)
2 2 2 3 4
2 2 2 3 4
1 1 1 2 3
VINV300/ 600/1200
DEV900/
1200*
DIL1200 DIL1200 DIL1200 DIL1200 DIL1200
7”/10”
(17.8/25.4cm)
4.2/5.2/8.2 4.2/5.2/8.2 5.2/8.2 10.8 10.8
8.0/5.3 8.0/5.3 8.0/5.3 7.8/8.5 7.8/8.5
5.3/7.2 5.3/7.2 5.3/7.2 9.6 10.0
35-7/8”
(91.1 cm)
VINV300/ 600/1200
DEV900/
1200*
7”/10”
(17.8/25.4cm)
41-7/8”
(106.4 cm)
12” (30.5 cm)
12” (30.5 cm)
VINV600/
1200
DEV900/
1200*
7”/10”
(17.8/25.4cm)
10” (24.5 cm)
47 Watts
8
47-7/8”
(121.6 cm)
VINV1200* VINV1200*
DEV1200*/
1500**
10”
(25.4 cm)
59-7/8” (152.1
cm)
DEV1200*/
1500**
10”
(25.4 cm)
3
0
m
i
n
.
(
7
6
.
2
c
m
)
t
o
3
6
m
a
x
.
(
9
1
.
4
c
m
)
6
6
” m
i
n
.
(
1
6
7
.
6
c
m
)
t
o
7
2
” m
a
x
.
(
1
8
2
.
9
c
m
)
36
(
9
1
.
4
c
m
)
Clearance Dimensions
(VWH/CVWH 18”H. Wall Hoods)
9
10" (25.4 cm) dia. duct location
B
A 30" W 14-15/16" (37.9 cm) 36" W 17-15/16" (45.6 cm) 42" W 20-15/16" (53.2 cm) 48" W 23-15/16" (60.8 cm) 60" W 29-15/16" (76.0 cm)
A
5-1/2"
(14.0 cm)
B 30" W 29-7/8" (75.9 cm) 36" W 35-7/8" (91.1 cm) 42" W 41-7/8" (106.4 cm) 48" W 47-7/8" (121.6 cm) 60" W 59-7/8" (152.1 cm)
A
B
7" (17.8 cm) dia. duct location
4-5/8"
(11.7 cm)
B 3
0" W 29-7/8" (75.9 cm) 36" W 35-7/8" (91.1 cm) 42" W 41-7/8" (106.4 cm) 48" W 47-7/8" (121.6 cm) 60" W 59-7/8" (152.1 cm)
A
3
0" W 14-15/16" (37.9 cm) 36" W 17-15/16" (45.6 cm) 42" W 20-15/16" (53.2 cm) 48" W 23-15/16" (60.8 cm) 60" W 29-15/16" (76.0 cm)
Interior Ventilator Dimensions
(VWH/CVWH 18”H. Wall Hoods)
Top View
300 or 600 CFM Interior Ventilator Installation for all Wall Hoods
Top View
1200 CFM Interior Ventilator Installation for all Wall Hoods
10
10" (25.4 cm) dia. duct location
A
B
A 30" W 14-15/16" (37.9 cm) 36" W 17-15/16" (45.6 cm) 42" W 20-15/16" (53.2 cm) 48" W 23-15/16" (60.8 cm) 60" W 29-15/16" (76.0 cm)
B 30" W 29-7/8" (75.9 cm) 36" W 35-7/8" (91.1 cm) 42" W 41-7/8" (106.4 cm) 48" W 47-7/8" (121.6 cm) 60" W 59-7/8" (152.1 cm)
5-15/16" (15.1 cm)
A
B
10" (25.4 cm) dia. duct location
5-15/16"
(15.1 cm)
A 30" W 14-15/16" (37.9 cm) 36" W 17-15/16" (45.6 cm) 42" W 20-15/16" (53.2 cm) 48" W 23-15/16" (60.8 cm) 60" W 29-15/16" (76.0 cm)
B 30" W 29-7/8" (75.9 cm) 36" W 35-7/8" (91.1 cm) 42" W 41-7/8" (106.4 cm) 48" W 47-7/8" (121.6 cm) 60" W 59-7/8" (152.1 cm)
Exterior Ventilator Dimensions
(VWH/CVWH 18”H. Wall Hoods)
Top View
900 or 1200 CFM Exterior or In-Line Ventilator Installation for all Wall
Hoods
Top View
1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all Wall
Hoods
11
2
7
"
(
6
8
.
6
c
m
)
A
1
8
"
(
4
5
.
7
c
m
)
6
"
(
1
5
.
2
c
m
)
A 36" W 35-7/8" (91.1 cm) 48" W 47-7/8" (121.6 cm) 60" W 59-7/8" (152.1 cm)
Dimensions & Specifications
(VWHO/CVWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”)
Number of lights
Number of filters
Interior ventilator kits
Exterior ventilator kits
In-line ventilator kits
Interior duct size
Exterior duct size
Interior—Maximum amps
Exterior—Maximum amps
In-Line—Maximum amps
Total watts
* A 1,200 CFM interior- or exterior-power ventilator should be used with all outdoor models and when indoor models are installed
over range/rangetop with gas char-grill. Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; A ll products must be hard wired with 2-wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
VWHO/CVWHO 18”H. Outdoor Wall Hoods
Description 36” 48” 60”
2 3 4
2 3 4
VINV1200* VINV1200* VINV1200*
DEV1200*/1500** DEV1200*/1500** DEV1200*/1500**
DIL1200 DIL1200 DIL1200
10” (25.4 cm)
10” (25.4 cm)
9.0 11.4 11.8
6.1/6.8 8.4/9.1 8.8/9.5
7.9 10.2 10.6
47 Watts
12
Loading...