Viking VWH53012, VWH53612, VWH53048, VWH53648, VWH54248 Installation Guide

...
0 (0)
Installation
Professional Indoor & Outdoor Hoods
VWH53012 / VWH53612
VWH53048 / VWH53648 / VWH54248
VWH54848 / VWH56048
VCWH53048 / VCWH53648 / VCWH54248
VCWH54848 / VCWH56048
VCIH53608 / VCIH54208 / VCIH55408 / VCIH56608
VWHO3678 / VWHO4878 / VWHO6078 (Canadian Outdoor models not applicable)
2
Warnings & Important Information
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 -
4
VWH/CVWH 10” H/12”H. Wall Hoods w/Standard Ventilator 30”, & 36”
D i m e n s i o n s & S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5
Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6
Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 7
VWH/CVWH 18”H. 24”Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”
D i m e n s i o n s & S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 8
Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 9
Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 0
Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 1
VWHO/CVWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”
D i m e n s i o n s & S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 2
Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 3
VCWH/CVCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, & 60”
D i m e n s i o n s & S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 4
Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 5
Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 6
Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 7
VCIH/CVCIH Chimney Island Hoods 36”, 42”, 54”, & 66”
D i m e n s i o n s & S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 8
Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 9
Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 0
Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 1
VBCV/CVBCV Wall Custom Ventilator System
D i m e n s i o n s & S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 2
Installing Hood Canopy _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 3
Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 4
VBCV Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 5
Planning Information _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 7
Installation Procedures
Installation (VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator) _ _ _ _ _ _ _ _ _ _ _ _ _ 28
Duct Cover Option (VWH/CVWH 12”H. Wall Hoods w/Standard Ventilator) _ _ _ _ _ _ _ _ _ _ _ _ 30
Installation (VWH/CVWH 12”H. Wall Hoods w/Recirculating Kit) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 30
Installation (VWH/CVWH 18”H. Wall & VCWH Chimney Wall Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 33
Duct Cover Option (VWH/CVWH 18”H. Wall Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 34
Duct Cover Option (VCWH/CVCWH Chimney Wall Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 35
Installation (VCIH Island Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 6
Service & Registration_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 8
Wiring Diagram _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 9
Table of Contents
3
NOTE:
If installing hood with warming shelf panel, install
warming shelf panel first.
IMPORTANT – PLEASE READ AND FOLLOW
• Before beginning, please read these instructions
completely and carefully.
• Do not remove permanently affixed labels, warnings, or
plates from the product. This may void the warranty.
• Please observe all local and national codes and
ordinances. If no local codes are applicable, wire in
accordance with the National Electrical Code,
ANSI/NFPA 70-latest edition.
• Damp environment approved models should be installed
in a covered non-enclosed area and should be protected
from the elements as much as possible.
• The installer should leave these instructions with the
consumer who should retain for local inspector’s use and
for future reference.
• Check with a qualified and trained installer or local codes
for makeup air requirement, if any.
This hood is for residential installation only and is not
designed for installation over a commercial product. Make
sure power is off at the main circuit breaker or fuse box
before making connections. To avoid risk of fire, electric
shock, or injury to persons, turn off the electricity to the
hood from the power supply before servicing or cleaning.
Viking hoods are equipped with variable speed control
blowers. These units will not function with a single speed
ventilator. All Viking Range ventilator kits are designed
specifically for use with Viking Range hoods. Use of any
non-Viking Range ventilator kit will void the hood warranty.
Viking hoods are equipped with the variable speed
controls for blowers. These units will not function with a
single speed ventilator. All Viking ventilator kits are
designed specifically for use with Viking hoods. Use of any
non-Viking ventilator kit will void the hood warranty.
READ AND SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Installation work and electrical wiring must be
done by qualified person(s) in accordance with
all applicable codes and standards, including
fire-rated construction.
2. Sufficient air is needed for proper combustion
and exhausting of gases through the flute
(chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the
American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the
local code authorities.
3. When cutting of drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
4. Ducted fans must always be vented to the outdoors.
5. WARNING!: To reduce risk of fire, use only
metal ductwork
6. CAUTION!: To reduce risk of fire and to
properly exhaust air, be sure to duct air outside.
Do not vent exhaust air into spaces within walls
or ceilings, or into attics, crawl spaces, or
garages.
7. CAUTION!: To Reduce the Risk of Fire and
Electric Shock, Install this rangehood only with
remote blower models manufactured by Viking,
model numbers – DEV900/DEV1200, VEV900,
VIL1200, OR DEV1500 or integral blowers
manufactured by Viking, model numbers –
VINV300/600/1200, or DIL1200. NOTE – Please
refer inside for specific canopy/blower
combinations.
WARNING
WARNING
To reduce the risk of fire, electric shock, or injury to
persons, observe the following:
• Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
• Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.
IMPORTANT–Please Read and Follow!
4
WARNING
TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK, OR INJURY
TO PERSONS
Rangehoods must be installed with
the ventilators that are specified on
their carton indicating suitability with
this model. Other ventilators cannot be substituted.
CAUTION
For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.
WARNING
To reduce the risk of injury to persons in the event
of a rangetop grease fire, observe the following.
(Based on “Kitchen Firesafety Tips,” published by
NFPA.)
1. SMOTHER FLAMES with a close fitted lid, cookie
sheet, or metal tray, then turn off the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do
not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN. You may be
burned.
3. DO NOT USE WATER, including wet dishcloths or
towels a violent steam explosion will result.
4. Use an extinguisher ONLY if
• You know it is a Class ABC extinguisher, and you
already know how to operate it.
• The fire is small and contained in the area where
it started.
• The fire department is being called.
• You can fight the fire with your back to an exit.
IMPORTANT–Please Read and Follow!
WARNING
This appliance is not to be used by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning the use of the appliance
by a person responsible for their safety. Children
should be supervised to ensure that they do not
play with the appliance.
5
21”
(53.3 cm)
A
10”
(25.4 cm)
12 ”
(30.5 cm)
A (Hood width)
30”W. 29-7/8“ (76.2 cm)
36”W. 35-7/8” (91.1 cm)
5”
(12.7 cm)
21”
(53.3 cm)
A
12 ”
(30.5 cm)
A (Hood width)
30”W. 29-7/8“ (76.2 cm)
36”W. 35-7/8” (91.1 cm)
5”
(12.7 cm)
12 ”
(30.5 cm)
(VWH 10”H./12”H. Wall Hoods w/Standard Ventilator 30”, & 36”)
* Disregard when using recirculating kits.
460 CFM blower is shipped with hood.
NOTE: Optional duct cover sold separately.
VWH/CVWH 10”H./12”H. Wall Hoods
w/Standard Ventilator
Description 30” 36”
Duct cover width
29-7/8” (75.9 cm) 35-7/8” (91.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
2
Number of filters
2
Heat lamps
N/A
Interior ventilator kit
460 CFM Standard
Interior duct size*
7” (17.8 cm)
Interior—Maximum amps
5.6 A
Dimensions & Specifications
6
* NOTE: When installing with a 24” high-shelf,
the 27” (68.6 cm) max. dimensions must be used.
24" min.
(61.0 cm)
to
27" max.*
(68.6 cm)
60" min.
(152.4 cm)
to
63" max.
(160.0 cm)
36"
(91.4 cm)
(VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator)
Clearance Dimensions
7
A
B
C
D
18”
(4.6 cm)
3-7/8”
(9.8 cm)
3-4”
(1.9 cm)
7” (17.8 cm) dia.
duct location
Electrical
hookup
1/2”
(1.3 cm)
4”
(10.2 cm)
3-1/2”
(8.9 cm)
A
24”W. 23-7/8” (60.6 cm)
30”W. 29-7/8” (75.9 cm)
36”W. 35-7/8” (91.1 cm)
B
24”W. 5-1/4” (13.3 cm)
30”W. 8-1/4” (20.9 cm)
36”W. 11-1/4” (28.6 cm)
C
24”W. 11-15/16” (30.3 cm)
30”W. 14-15/16” (37.9 cm)
36”W. 17-15/16” (45.6 cm)
D
24”W. 5/8” (1.6 cm)
30”W. 3-5/8” (9.2 cm)
36”W. 6-5/8” (16.8 cm)
460 CFM Interior Ventilator Installation
Top View
(VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator)
Interior Ventilator Dimensions
8
24"
(61.0 cm)
A
18"
(45.7 cm)
12"
(30.5 cm)
6"
(15.2 cm)
A
30" W 29-7/8" (76.2 cm)
36" W 35-7/8" (91.1 cm)
42" W 41-7/8" (106.4 cm)
48" W 47-7/8" (121.6 cm)
60" W 59-7/8" (152.1 cm)
(VWH/CVWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
NOTE: Optional duct cover sold separately.
VWH/CVWH 18”H. Wall Hoods
Description 30” 36” 42” 48” 60”
Duct cover width
29-7/8”
(75.9 cm)
35-7/8”
(91.1 cm)
41-7/8”
(106.4 cm)
47-7/8”
(121.6 cm)
59-7/8”
(152.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
2 2 2 3 4
Number of filters
2 2 2 3 4
Heat lamps
1 1 1 2 3
Interior ventilator kits
VINV300/
600/1200
VINV300/
600/1200
VINV600/
1200
VINV1200* VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL1200 DIL1200 DIL1200 DIL1200 DIL1200
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
Exterior duct size
10” (24.5 cm)
Interior—Maximum amps
4.2/5.2/8.2 4.2/5.2/8.2 5.2/8.2 10.8 10.8
Exterior—Maximum amps
8.0/5.3 8.0/5.3 8.0/5.3 7.8/8.5 7.8/8.5
In-Line—Maximum amps
5.3/7.2 5.3/7.2 5.3/7.2 9.6 10.0
Total Watts
47 Watts
Dimensions & Specifications
9
30” min.
(76.2 cm)
to
36” max.
(91.4 cm)
66” min.
(167.6 cm)
to
72” max.
(182.9 cm)
36”
(91.4 cm)
(VWH/CVWH 18”H. Wall Hoods)
Clearance Dimensions
10
10" (25.4 cm)
dia. duct location
B
A
30" W 14-15/16" (37.9 cm)
36" W 17-15/16" (45.6 cm)
42" W 20-15/16" (53.2 cm)
48" W 23-15/16" (60.8 cm)
60" W 29-15/16" (76.0 cm)
A
5-1/2"
(14.0 cm)
B
30" W 29-7/8" (75.9 cm)
36" W 35-7/8" (91.1 cm)
42" W 41-7/8" (106.4 cm)
48" W 47-7/8" (121.6 cm)
60" W 59-7/8" (152.1 cm)
A
B
7" (17.8 cm)
dia. duct location
4-5/8"
(11.7 cm)
B
30" W 29-7/8" (75.9 cm)
36" W 35-7/8" (91.1 cm)
42" W 41-7/8" (106.4 cm)
48" W 47-7/8" (121.6 cm)
60" W 59-7/8" (152.1 cm)
A
30" W 14-15/16" (37.9 cm)
36" W 17-15/16" (45.6 cm)
42" W 20-15/16" (53.2 cm)
48" W 23-15/16" (60.8 cm)
60" W 29-15/16" (76.0 cm)
300 or 600 CFM Interior Ventilator Installation for all Wall Hoods
1200 CFM Interior Ventilator Installation for all Wall Hoods
Top View
Top View
(VWH/CVWH 18”H. Wall Hoods)
Interior Ventilator Dimensions
11
10" (25.4 cm)
dia. duct location
A
B
A
30" W 14-15/16" (37.9 cm)
36" W 17-15/16" (45.6 cm)
42" W 20-15/16" (53.2 cm)
48" W 23-15/16" (60.8 cm)
60" W 29-15/16" (76.0 cm)
B
30" W 29-7/8" (75.9 cm)
36" W 35-7/8" (91.1 cm)
42" W 41-7/8" (106.4 cm)
48" W 47-7/8" (121.6 cm)
60" W 59-7/8" (152.1 cm)
5-15/16"
(15.1 cm)
A
B
10" (25.4 cm)
dia. duct location
5-15/16"
(15.1 cm)
A
30" W 14-15/16" (37.9 cm)
36" W 17-15/16" (45.6 cm)
42" W 20-15/16" (53.2 cm)
48" W 23-15/16" (60.8 cm)
60" W 29-15/16" (76.0 cm)
B
30" W 29-7/8" (75.9 cm)
36" W 35-7/8" (91.1 cm)
42" W 41-7/8" (106.4 cm)
48" W 47-7/8" (121.6 cm)
60" W 59-7/8" (152.1 cm)
900 or 1200 CFM Exterior or In-Line Ventilator Installation for all
Wall Hoods
1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all
Wall Hoods
Top View
Top View
(VWH/CVWH 18”H. Wall Hoods)
Exterior Ventilator Dimensions
12
27"
(68.6 cm)
A
18"
(45.7 cm)
12"
(30.5 cm)
6"
(15.2 cm)
A
36" W 35-7/8" (91.1 cm)
48" W 47-7/8" (121.6 cm)
60" W 59-7/8" (152.1 cm)
Seal joints with silicone.
Provided on “T” Series only.
(VWHO/CVWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”)
* A 1,200 CFM interior- or exterior-power ventilator should be used with all outdoor models and when i ndoor models are
installed over range/rangetop with gas char-grill. Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
NOTE: Optional duct cover sold separately.
VWHO/CVWHO 18”H. Outdoor Wall Hoods
Description 36” 48” 60”
Duct cover width
35-7/8” (91.1 cm) 47-7/8” (121.6 cm) 59-7/8” (152.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
2 3 4
Number of filters
2 3 4
Interior ventilator kits
VINV1200* VINV1200* VINV1200*
Exterior ventilator kits
DEV1200*/1500** DEV1200*/1500** DEV1200*/1500**
In-line ventilator kits
DIL1200 DIL1200 DIL1200
Interior duct size
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
9.0 11.4 11.8
Exterior—Maximum amps
6.1/6.8 8.4/9.1 8.8/9.5
In-Line—Maximum amps
7.9 10.2 10.6
Total watts
47 Watts
Dimensions & Specifications