Viking VGIQ530T, VGBQ530E, VGIQ530E, VGIQ532T, VGBQ412T User Manual

...
Viking Installation Guide
Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
IMPORTANT: PLEASE READ AND FOLLOW
Before beginning, please read these instructions completely and carefully.
plates from product. This may void the warranty
Please observe all local and national codes and ordinances.
The installer should leave these instructions with the consumer who should retain for local inspector's use and
for future reference
EXCESSIVE WEIGHT HAZARD
Use two or more people to move and install this unit. Failure to follow this instruction can result in back or
other injury.
Installation must conform with local codes or in the absence of codes, the National Fuel Gas Code, ANSI Z223.1. In
Canada: Installation must be in accordance with the current
CAN/CGA-B149.1, Natural Gas and Propane Installation Code or CAN/CGA-B149.2, Propane Storage and Handling
Code and/or local codes. For units with an external electrical souce, when installed, must be electrically
grounded in accordance with local codes or with the National Electrical code ANBI/NFPAT0, or Canadian Electrical
code, CBA C22.1
GENERAL INFORMATION
A&WARNING: This outdoor gas grill is not intended
to be installed in or on recreational vehicles and/or boats.
WARNING: Keep electrical supply cord and the
fuel supply hose away from heated surfaces.
i WARNING: This appliance is not fused. Installer
must install a ground fault interrupt.
Keep grill area clear and free from combustible materials, gasoline, and other flammable vapors.
When the outdoor grill is not in use, the gas supply must be turned off at the LP gas supply cylinder.
The pressure regulator and hose assembly supplied with
the outdoor grill must be used. Replacement pressure
regulators and hose assemblies must be those specified by the manufacturer.
Finding a leak is not a "do-it-yourself" procedure. Some leaks can only be found with the burner control in the on
position and this must be clone by a qualified technician.
The LP supply cylinder to be used must be constructed and marked in accordance with the specifications for LP- gas cylinders of the U.S. Department of Transportation
(DOT) or the National Standard of Canada, CAN/CSA- B337, Cy/inders, Spheres, and Tubes for the
Transportation of Dangerous Goods.
Gas Manifold Pressure -
Natural gas - 4.0" W.C.R LP/Propane - 10.0" W.C.R
If the following instructions are not followed exactly, a fire causing death or serious injury may occur:
-Do not store a spare LP gas cylinder under or near this appliance.
-Never fill the cylinder beyond 80 percent full.
FOR YOUR SAFETY
If you smellgas:
1. Shutoff gasto the appliance.
2. Extinguishany open flame.
3. Open lid.
4. If odor continues, keep away from the appliance, immediately call your gas supplier or your fire
department.
FOR YOUR SAFETY
1. Do not store or usegasoline or other flammable vaporsand liquids inthe vicinity of this or any
other appliance.
2. Any LPcylinder not connected for use shallnot be stored inthe vicinity of this or any other appliance.
Ifnot installed,operated and maintained in
accordance with the manufacturer'sinstructions,this
product could expose you to substancesinfuel or fuel combustion which can causedeath or serious
illnessand which areknown to causecancer,birth defects or other reproductive harm.
Forexample, benzene is a chemicalwhich is partof the gas supplied to the cooking
product. It is consumed inthe flame during
combustion. However,exposureto a small amount of benzene is possible ifa gas leak
occurs. Formaldehyde and soot are by-
productsof incomplete combustion. Properly adjusted burners with a bluish rather than yellow flame minimize incomplete combustion.
2
BASIC SPECIFICATIONS T-SERIES GRILLS
Description Cutout Width
Cutout Depth Cutout Height Overall Width
Overall Depth Gas
Requirements
Electrical Requirements
Grill Burner Rating
TilJSea rTM Burner
Rating (if applicable) Smoker Burner
Rating (Ifapplicable) Side Burner
Rating (Ifapplicable) RotisserieBurner
Rating (Ifapplicable) Approximate
Shipping Weight
VGBQ30OT/O302T VGIQ300T
28 5/8" 28 5/8"
(72.7 cm) (72.7 cm)
VGBQ410T/VGIQ41 OT
40 1/4"
(102.2cm)
VGBQ412T
40 1/4"
(102.2cm)
28" (71.1cm)
101/4" (26.0cm)
29 1/2" 29 1/2" 41 3/16" 41 3/16"
(74.9cm) (74.9cm) (104.6cm) (104.6cm)
32 3/4" (83.2cm)
Natural: standard residential 1/2" (1.3 cm)ID gas service line. LP/Propane: equipped with high capacity hose/regulator assembly for connection to standard 5gal, 20 lb.
LP/Propane gas cylinder with Type 1, QCC-1 connection or standard residential 1/2" (1.3 cm) ID gas service line.
9 volt DC battery for electronic ignition
120VAC/60HZ - 24" (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor
25,000 BTU Nat./22,500 BTU LP
(7.3 kW Nat./&5 kW LP)
N/A
12,500Nat./10,500 LPBTU
(3.7 kW Nat./3.1 kW LP)
325 Ibs. (147kg)
30,000 BTU Nat/LP
8.3 kW Nat./LP N/A
15,000 BTU Nat./13,500 BTU LP
(4.4 kW Nat./4.0 kW LP)
(1) 15,000 Nat./13,500 BTU LP
(4.4 kW Nat./4.0 kW LP)
325 Ibs. 380 Ibs. (147 kg) (172 kg)
30,000 BTU Nat./LP N/A
8.3 kW Nat./LP 12,500 BTU Nat./10,500 BTU LP
(3.7 kW Nat./3.1 kW LP)
350 Ibs. (159kg)
Description Cutout Width
Cutout Depth Cutout Height
Overall Width Overall Depth
Gas Requirements
Electrical Requirements
Grill Burner Rating
TruSearTM Burner Rating (If applicable)
Smoker Burner Rating
Side Burner Rating (if applicable)
Rotisserie Burner Rating
Approximate Shipping Weight
VGBQB30T/VGIQB30T VGBQB32T/VGIQ532T
52 1/4'j (132.7 cm)
1
28" (71.1 cm)
10 1/4" (26.0 cm)
53 3/16" (135.1 cm)
32 3/4" (83.2 cm) Natural: standard residential 1/2" (1.3 cm) ID gas service line. LP/Propane: equipped with high capacity hose/regulator assembly for connection to standard 5gal, 20 lb.
LP/Propane gas cylinder with Type 1, QCC-1 connection or standard residential 1/2" (1.3 cm) ID gas service line.
9volt DC battery for electronic ignition 120VAC/60HZ - 24" (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor
25,000 BTU Nat./22,500 BTU LP
(7.3 kW Nat./&5 kW LP)
30,000 BTU Nat./LP
8.8 kW Nat./LP 12,500 BTU Nat./10,500 BTU LP
(3.7 kW Nat./3.1 kW LP)
15,000 BTU Nat./13,500 BTU LP
(4.4 kW Nat./4.0 kW LP)
(2)15,000Nat./13,500BTULP
(4.4kW Nat./4.0kW LP)
490 Ibs. (222kg)
30,000 BTU Nat./LP
8.8 kW Nat./LP
(1) 15,000 BTU Nat./13.500 BTU LP
(4.4 kW Nat./4.0 kW LP)
460 Ibs. (209 kg)
3
BASIC SPECIFICATIONS E-SERIES GRILLS
Description Cutout Width
Cutout Depth Cutout Height
Overall Width
Overall Depth ,Sas
Requirements
Electrical Requirements
Maximum Amp Usage
Still Burner Rating
TruSearTM Burner
Rating (if applicable) Smoker Burner
Rating (If applicable) Side Burner
Rating (If applicable) RotisserieBurner
Rating (If applicable) &pproximate
Shipping Weight
VGBQ300E VGIQ300E VGBQ410ENGIQ410E VGBQ412E
28 5/8" 28 5/8" 40 1/4" 40 1/4"
(72.7cm) (72.7cm) (102.2cm) (102.2cm)
28" (71.1cm) 10 1/4" (26.0cm)
29 1/2" 29 1/2" 41 3/16" 41 3/16"
(74.9cm) (74.9cm) (104.6cm) (104.6cm)
32 3/4" (83.2cm)
Natural: standard residential 1/2" (1.3 cm) ID gas service line. LP/Propane: equipped with high capacity hose/regulator assembly for connection to standard 5gal, 20 lb.
LP/Propane gas cylinder with Type 1, QCC-1 connection or standard residential 1/2" (1.3 cm) ID gas service line.
120VAC/60HZ - 3' ( 91.4 cm) power cord supply cord with 3-prong grounded plug attached to grill 120VAC/d0HZ - 24" (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor
2.1amps
N/A
12,500 Nat./10,500 LP BTU
(3.7 kW Nat./3.1 kW LP)
325 Ibs. 325 Ibs. 380 Ibs. 350 Ibs. (147 kg) (147 kg) (172 kg) (159 kg)
2.1 amps 2.2 amps 2.3 amps 25,000 BTU Nat./22,500 BTU LP
(7.3 kW Nat./&5 kW LP)
30,000 BTU Nat/LP 30,000 BTU Nat./LP
8.3 kW Nat./LP 8.3 kW Nat./LP N/A 12,500 BTU Nat./10,500 BTU LP
(3.7 kW Nat./3.1 kW LP)
15,000 BTU Nat./13,500 BTU LP
(4.4 kW Nat./4.0 kW LP
(1)15,000 Nat./13,500 BTU LP
(4.4 kW Nat./4.0 kW LP)
N/A
Description Cutout Width
Cutout Depth Cutout Height
Overall Width Overall Depth
Gas Requirements
Electrical Recluirements
Maximum Amp Usage Grill Burner
Rating TruSeaFMBurner
Rating (If applicable) Smoker Burner
Rating Side Burner
Rating (If applicable) Rotisserie Burner
Rating Approximate
Shipping Weight
VGBQ530ENGIQ530E VGBQ532E/VGIQ532E
52 1/4" (132.7cm) 28" (71.1cm)
10 1/4" (26.0cm)
53 3/16" (135.1cm)
323/4" (83.2cm)
Natural: standardresidential1/2" (1.3cm)ID gasserviceline. LP/Propane: equipped with high capacityhose/regulatorassemblyfor connectionto standard5gal,20 lb.
LP/Propanegas cylinderwithType 1,QCC-1connectionor standardresidential1/2" (1.3cm) ID gas serviceline.
120VAC/60HZ-3' ( 91.4cm) powercordsupplycord with 3-prong grounded plug attachedto grill 120VAC/&0HZ- 24" (51.0cm)power cordsupplycord with 3-prong grounded plug attachedto rotisseriemotor
3.0 amps 3.0 amps 25,000 BTU Nat./22,500 BTU LP
(7.3 kW Nat./&5 kW LP)
30,000 BTU Nat./LP I 30,000 BTU Nat./LP
8.8 kW Nat./LP I 8.8 kW Nat./LP 12,500 BTU Nat./10,500 BTU LP
(3.7 kW Nat./3.1 kW LP)
15,000 BTU Nat./13,500 BTU LP
(4.4 kW Nat./4.0 kW LP)
(2)15,000 Nat./13,500 BTU LP (1) 15,000 BTU Nat./13.500 BTU LP
(4.4 kW Nat./4.0 kW LP) (4.4 kW Nat./4.0 kW LP)
490 Ibs. 460 Ibs. (222 kg) (209 kg)
GAS CONNECTION
Verify the type of gas supply to be used, either natural or LP,and make sure the marking on the grill rating
plate agrees with that of the supply. Never connect an unregulated gas line to the appliance. An installer supplied gas
shut-off valve must be installed in an easily accessible location. All installer supplied parts must conform to local codes, or in the absence of local codes, with the National electrical Code, ANSI/NFPA 70 and the National Fuel Code, ANSI
Z223.1. In Canada: Installation must be in accordance with the current CAN/CGA-B142.l, Natural Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes. All pipe sealants must be an approved type
and resistant to the actions of LP gas. Never use pipe sealant on flare fittings. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances, in the absence of codes, the installation
must comply with the National Fuel Gas Code ANSI Z223.1.
The gas grill and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa). The gas grill must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system
at test pressures equal to or less than 1/2 psi (3.5 kPa).
GAS CONVERSION
To convert a grill from natural to LP/Propane or LP/Propane to natural, you MUST use the conversion kit supplied by the manufacturer.
Conversions should only be performed by an authorized service
technician.
ELECTRICAL CONNECTION FOR E-SERIESGRILLS
ELECTRICAL SHOCK HAZARD
This appliance is equipped with a 3' (91.4 cm) 3-prong
with a grounding plug for your protection
ainst shock hazard and should be plugged directly into a
rounded receptacle. Do not cut or remove the
prong from this plug. This unit is not fused and
installer must install a GFI. Unit must be grounded in accordance with local codes or with the National Electrical
Code ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1