Viking Installation Guide
Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
IMPORTANT:
PLEASE READ AND FOLLOW
• Before beginning, please read these instructions
completely and carefully.
• Do not remove permanently affixed labels, warnings, or
plates from product. This may void the warranty
• Please observe all local and national codes and ordinances.
• The installer should leave these instructions with the
consumer who should retain for local inspector's use and
for future reference
EXCESSIVE WEIGHT HAZARD
Use two or more people to move and install this unit.
Failure to follow this instruction can result in back or
other injury.
Installation must conform with local codes or in the absence
of codes, the National Fuel Gas Code, ANSI Z223.1. In
Canada: Installation must be in accordance with the current
CAN/CGA-B149.1, Natural Gas and Propane Installation
Code or CAN/CGA-B149.2, Propane Storage and Handling
Code and/or local codes. For units with an external
electrical souce, when installed, must be electrically
grounded in accordance with local codes or with the
National Electrical code ANBI/NFPAT0, or Canadian Electrical
code, CBA C22.1
GENERAL INFORMATION
A&WARNING: This outdoor gas grill is not intended
to be installed in or on recreational vehicles and/or boats.
WARNING: Keep electrical supply cord and the
fuel supply hose away from heated surfaces.
i WARNING: This appliance is not fused. Installer
must install a ground fault interrupt.
•Keep grill area clear and free from combustible materials,
gasoline, and other flammable vapors.
•When the outdoor grill is not in use, the gas supply must
be turned off at the LP gas supply cylinder.
•The pressure regulator and hose assembly supplied with
the outdoor grill must be used. Replacement pressure
regulators and hose assemblies must be those specified
by the manufacturer.
•Finding a leak is not a "do-it-yourself" procedure. Some
leaks can only be found with the burner control in the on
position and this must be clone by a qualified technician.
•The LP supply cylinder to be used must be constructed
and marked in accordance with the specifications for LP-
gas cylinders of the U.S. Department of Transportation
(DOT) or the National Standard of Canada, CAN/CSA-
B337, Cy/inders, Spheres, and Tubes for the
Transportation of Dangerous Goods.
•Gas Manifold Pressure -
Natural gas - 4.0" W.C.R
LP/Propane - 10.0" W.C.R
•If the following instructions are not followed exactly, a fire
causing death or serious injury may occur:
-Do not store a spare LP gas cylinder under or near this
appliance.
-Never fill the cylinder beyond 80 percent full.
FOR YOUR SAFETY
If you smellgas:
1. Shutoff gasto the appliance.
2. Extinguishany open flame.
3. Open lid.
4. If odor continues, keep away from the appliance,
immediately call your gas supplier or your fire
department.
FOR YOUR SAFETY
1. Do not store or usegasoline or other flammable
vaporsand liquids inthe vicinity of this or any
other appliance.
2. Any LPcylinder not connected for use shallnot be
stored inthe vicinity of this or any other appliance.
Ifnot installed,operated and maintained in
accordance with the manufacturer'sinstructions,this
product could expose you to substancesinfuel or
fuel combustion which can causedeath or serious
illnessand which areknown to causecancer,birth
defects or other reproductive harm.
Forexample, benzene is a chemicalwhich is
partof the gas supplied to the cooking
product. It is consumed inthe flame during
combustion. However,exposureto a small
amount of benzene is possible ifa gas leak
occurs. Formaldehyde and soot are by-
productsof incomplete combustion. Properly
adjusted burners with a bluish rather than
yellow flame minimize incomplete combustion.
2
BASIC SPECIFICATIONS T-SERIES GRILLS
Description
Cutout Width
Cutout Depth
Cutout Height
Overall Width
Overall Depth
Gas
Requirements
Electrical
Requirements
Grill Burner
Rating
TilJSea rTM Burner
Rating (if applicable)
Smoker Burner
Rating (Ifapplicable)
Side Burner
Rating (Ifapplicable)
RotisserieBurner
Rating (Ifapplicable)
Approximate
Shipping Weight
VGBQ30OT/O302T VGIQ300T
28 5/8" 28 5/8"
(72.7 cm) (72.7 cm)
VGBQ410T/VGIQ41 OT
40 1/4"
(102.2cm)
VGBQ412T
40 1/4"
(102.2cm)
28" (71.1cm)
101/4" (26.0cm)
29 1/2" 29 1/2" 41 3/16" 41 3/16"
(74.9cm) (74.9cm) (104.6cm) (104.6cm)
32 3/4" (83.2cm)
Natural: standard residential 1/2" (1.3 cm)ID gas service line.
LP/Propane: equipped with high capacity hose/regulator assembly for connection to standard 5gal, 20 lb.
LP/Propane gas cylinder with Type 1, QCC-1 connection or standard residential 1/2" (1.3 cm)
ID gas service line.
9 volt DC battery for electronic ignition
120VAC/60HZ - 24" (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor
25,000 BTU Nat./22,500 BTU LP
(7.3 kW Nat./&5 kW LP)
N/A
12,500Nat./10,500 LPBTU
(3.7 kW Nat./3.1 kW LP)
325 Ibs.
(147kg)
30,000 BTU Nat/LP
8.3 kW Nat./LP
N/A
15,000 BTU Nat./13,500 BTU LP
(4.4 kW Nat./4.0 kW LP)
(1) 15,000 Nat./13,500 BTU LP
(4.4 kW Nat./4.0 kW LP)
325 Ibs. 380 Ibs.
(147 kg) (172 kg)
30,000 BTU Nat./LP N/A
8.3 kW Nat./LP
12,500 BTU Nat./10,500 BTU LP
(3.7 kW Nat./3.1 kW LP)
350 Ibs.
(159kg)
Description
Cutout Width
Cutout Depth
Cutout Height
Overall Width
Overall Depth
Gas
Requirements
Electrical
Requirements
Grill Burner
Rating
TruSearTM Burner
Rating (If applicable)
Smoker Burner
Rating
Side Burner
Rating (if applicable)
Rotisserie Burner
Rating
Approximate
Shipping Weight
VGBQB30T/VGIQB30T VGBQB32T/VGIQ532T
52 1/4'j (132.7 cm)
1
28" (71.1 cm)
10 1/4" (26.0 cm)
53 3/16" (135.1 cm)
32 3/4" (83.2 cm)
Natural: standard residential 1/2" (1.3 cm) ID gas service line.
LP/Propane: equipped with high capacity hose/regulator assembly for connection to standard 5gal, 20 lb.
LP/Propane gas cylinder with Type 1, QCC-1 connection or standard residential 1/2" (1.3 cm)
ID gas service line.
9volt DC battery for electronic ignition
120VAC/60HZ - 24" (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor
25,000 BTU Nat./22,500 BTU LP
(7.3 kW Nat./&5 kW LP)
30,000 BTU Nat./LP
8.8 kW Nat./LP
12,500 BTU Nat./10,500 BTU LP
(3.7 kW Nat./3.1 kW LP)
15,000 BTU Nat./13,500 BTU LP
(4.4 kW Nat./4.0 kW LP)
(2)15,000Nat./13,500BTULP
(4.4kW Nat./4.0kW LP)
490 Ibs.
(222kg)
30,000 BTU Nat./LP
8.8 kW Nat./LP
(1) 15,000 BTU Nat./13.500 BTU LP
(4.4 kW Nat./4.0 kW LP)
460 Ibs.
(209 kg)
3
BASIC SPECIFICATIONS E-SERIES GRILLS
Description
Cutout Width
Cutout Depth
Cutout Height
Overall Width
Overall Depth
,Sas
Requirements
Electrical
Requirements
Maximum Amp
Usage
Still Burner
Rating
TruSearTM Burner
Rating (if applicable)
Smoker Burner
Rating (If applicable)
Side Burner
Rating (If applicable)
RotisserieBurner
Rating (If applicable)
&pproximate
Shipping Weight
VGBQ300E VGIQ300E VGBQ410ENGIQ410E VGBQ412E
28 5/8" 28 5/8" 40 1/4" 40 1/4"
(72.7cm) (72.7cm) (102.2cm) (102.2cm)
28" (71.1cm)
10 1/4" (26.0cm)
29 1/2" 29 1/2" 41 3/16" 41 3/16"
(74.9cm) (74.9cm) (104.6cm) (104.6cm)
32 3/4" (83.2cm)
Natural: standard residential 1/2" (1.3 cm) ID gas service line.
LP/Propane: equipped with high capacity hose/regulator assembly for connection to standard 5gal, 20 lb.
LP/Propane gas cylinder with Type 1, QCC-1 connection or standard residential 1/2" (1.3 cm)
ID gas service line.
120VAC/60HZ - 3' ( 91.4 cm) power cord supply cord with 3-prong grounded plug attached to grill
120VAC/d0HZ - 24" (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor
2.1amps
N/A
12,500 Nat./10,500 LP BTU
(3.7 kW Nat./3.1 kW LP)
325 Ibs. 325 Ibs. 380 Ibs. 350 Ibs.
(147 kg) (147 kg) (172 kg) (159 kg)
2.1 amps 2.2 amps 2.3 amps
25,000 BTU Nat./22,500 BTU LP
(7.3 kW Nat./&5 kW LP)
30,000 BTU Nat/LP 30,000 BTU Nat./LP
8.3 kW Nat./LP 8.3 kW Nat./LP
N/A 12,500 BTU Nat./10,500 BTU LP
(3.7 kW Nat./3.1 kW LP)
15,000 BTU Nat./13,500 BTU LP
(4.4 kW Nat./4.0 kW LP
(1)15,000 Nat./13,500 BTU LP
(4.4 kW Nat./4.0 kW LP)
N/A
Description
Cutout Width
Cutout Depth
Cutout Height
Overall Width
Overall Depth
Gas
Requirements
Electrical
Recluirements
Maximum Amp
Usage
Grill Burner
Rating
TruSeaFMBurner
Rating (If applicable)
Smoker Burner
Rating
Side Burner
Rating (If applicable)
Rotisserie Burner
Rating
Approximate
Shipping Weight
VGBQ530ENGIQ530E VGBQ532E/VGIQ532E
52 1/4" (132.7cm)
28" (71.1cm)
10 1/4" (26.0cm)
53 3/16" (135.1cm)
323/4" (83.2cm)
Natural: standardresidential1/2" (1.3cm)ID gasserviceline.
LP/Propane: equipped with high capacityhose/regulatorassemblyfor connectionto standard5gal,20 lb.
LP/Propanegas cylinderwithType 1,QCC-1connectionor standardresidential1/2" (1.3cm)
ID gas serviceline.
120VAC/60HZ-3' ( 91.4cm) powercordsupplycord with 3-prong grounded plug attachedto grill
120VAC/&0HZ- 24" (51.0cm)power cordsupplycord with 3-prong grounded plug attachedto rotisseriemotor
3.0 amps 3.0 amps
25,000 BTU Nat./22,500 BTU LP
(7.3 kW Nat./&5 kW LP)
30,000 BTU Nat./LP I 30,000 BTU Nat./LP
8.8 kW Nat./LP I 8.8 kW Nat./LP
12,500 BTU Nat./10,500 BTU LP
(3.7 kW Nat./3.1 kW LP)
15,000 BTU Nat./13,500 BTU LP
(4.4 kW Nat./4.0 kW LP)
(2)15,000 Nat./13,500 BTU LP (1) 15,000 BTU Nat./13.500 BTU LP
(4.4 kW Nat./4.0 kW LP) (4.4 kW Nat./4.0 kW LP)
490 Ibs. 460 Ibs.
(222 kg) (209 kg)
GAS CONNECTION
Verify the type of gas supply to be used, either natural or LP,and make sure the marking on the grill rating
plate agrees with that of the supply. Never connect an unregulated gas line to the appliance. An installer supplied gas
shut-off valve must be installed in an easily accessible location. All installer supplied parts must conform to local codes,
or in the absence of local codes, with the National electrical Code, ANSI/NFPA 70 and the National Fuel Code, ANSI
Z223.1. In Canada: Installation must be in accordance with the current CAN/CGA-B142.l, Natural Gas Installation
Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes. All pipe sealants must be an approved type
and resistant to the actions of LP gas. Never use pipe sealant on flare fittings. All gas connections should be made by
a competent technician and in accordance with local codes and or ordinances, in the absence of codes, the installation
must comply with the National Fuel Gas Code ANSI Z223.1.
The gas grill and its individual shut-off valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa). The gas grill must be isolated from
the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system
at test pressures equal to or less than 1/2 psi (3.5 kPa).
GAS CONVERSION
To convert a grill from natural to LP/Propane or LP/Propane to natural, you MUST use the conversion kit
supplied by the manufacturer.
Conversions should only be performed by an authorized service
technician.
ELECTRICAL CONNECTION FOR E-SERIESGRILLS
ELECTRICAL SHOCK HAZARD
This appliance is equipped with a 3' (91.4 cm) 3-prong
with a grounding plug for your protection
ainst shock hazard and should be plugged directly into a
rounded receptacle. Do not cut or remove the
prong from this plug. This unit is not fused and
installer must install a GFI. Unit must be grounded in
accordance with local codes or with the National Electrical
Code ANSI/NFPA 70, or the Canadian Electrical Code, CSA
C22.1