Installation
®
3 Series
Freestanding 30” Dual Fuel
Self-Clean Sealed Burner Range
IMPORTANT–Read and Follow!
3
2
Table of Contents
• Before beginning, please read these instructions completely and carefully.
DO NOT remove permanently affixed labels, warnings, or plates from product. This may void the warranty.
• All local and national codes and ordinances must be observed. Installation must conform with local codes or in the absence of codes, the National Fuel Gas Code ANSI Z223.1/NFPA-54 – latest edition.
• The installer must leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
In Canada: Installation must be in accordance with the current CAN/CGA B149.1 & 2 Gas Installation codes and/or local codes. Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes.
In Massachusetts: All gas products must be installed by a “Massachusetts” licensed plumber or gasfitter. A “T” type handle manual valve must be installed in the gas supply line to the appliance.
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. ALWAYS read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word “DANGER,” “WARNING” or “CAUTION.” These words mean:
Hazards or unsafe practices
which WILL result in severe personal
injury or death.
DANGER
Hazards or unsafe practices
which COULD result in severe personal
injury or death.
Hazards or unsafe practices which
COULD result in minor personal injury or
property damage.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
WARNING
CAUTION
Warnings & Important Safety Instructions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3
D i m e n s i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6
S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 7
Clearance Dimensions (Proximity to Cabinets) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 8
Clearance Dimensions (Wood/Composite Overlay) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 9
Electrical & Gas Requirements _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 0
General Infor mation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 2
I n s t a l l a t i o n _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 3
Door Removal _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 3
L e g I n s t a l l a t i o n _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 4
Electrical Connection (3-Wire) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 5
Electrical Connection (4-Wire) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 7
L e v e l i n g / A d j u s t m e n t s / A l i g n m e n t _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 9
A n t i - t i p D e v i c e I n s t a l l a t i o n _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 0
W a l l M o u n t A n t i - t i p I n s t a l l a t i o n _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 0
Floor Mount Anti-tip Installation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 1
Connecting Gas & Electrical _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 2
F i n a l I n s t a l l a t i o n _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 3
Door Replacement and Adjustment _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 4
Final Preparation_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 5
Performance Checklist _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 5
Service & Registration _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 6
IMPORTANT–Read and Follow!
54
DANGER
GAS LEAK HAZARD
To avoid risk of personal injury or death; leak testing of the
appliance must be conducted according to the manufacturer’s instructions. Before placing appliance in operation, always check for gas leaks with soapy water solution.
• DO NOT USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS.
DANGER
ELECTRICAL SHOCK HAZARD
To avoid risk of electrical shock,
personal injury or death; verify your appliance has been properly grounded in accordance with local codes or in absence of codes, with the National Electrical Code (NEC). ANSI/NFPA-70 – latest edition.
WARNING
MOVING HAZARD
To avoid risk of severe personal injury; this appliance
requires two or more personnel while handling and moving. Possible use of appliance moving devices is recommended.
DANGER
FIRE/EXPLOSION HAZARD
IF THE INFORMATION IN
THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
DO NOT store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
DO NOT try to light any appliance.DO NOT touch any electrical switch;
DO NOT use any phone in your building.
–Immediately call your gas supplier from
a neighbor’s phone. –Follow the gas supplier’s instructions. –If you cannot reach your gas supplier,
call the fire department.
• Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
DANGER
CHEMICAL HAZARD
To avoid risk of property damage and/or personal injury or death; this appliance is not
too be used as a heating source.
• Benzene is a chemical which is part of the gas supply to this cooking product, which is consumed in the flames during combustion. Exposure to a small amount of benzene is possible if a gas leak occurs. Formaldehyde and soot are by-products of incomplete combustion.
• This appliance contains or produces chemicals which can cause serious injury or death and which are known to the state of California to cause cancer, birth defects or other reproductive harm. To reduce the risk from substances in the fuel or from fuel combustion make sure this appliance is installed, operated, and maintained in accordance to the instructions in this document.
CAUTION
To prevent possible damage to cabinets and cabinet finishes, use only materials and finishes that will not discolor or delaminate and will withstand temperatures up to 194°F (90°C). Heat resistant adhesive must be used if the product is to be installed in laminated cabinetry. Check with your builder or cabinet supplier to make sure that the materials meet these requirements.
A GFI
shall be used if required by NFPA-70 (National Electric Code), federal/state/local
laws, or local ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture.
• Viking Range, LLC will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below.
If the use of a GFI is required
, it should be:
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
WARNING
TIPPING HAZARD
To reduce the risk of the appliance tipping, it must be secured by a properly installed anti-tip bracket(s). To make sure the bracket has been installed properly, look behind the range with a flashlight to
verify proper installation engaged in the rear top left corner of the range or under the range to verify that a floor hook and bracket have been installed.
• THIS RANGE CAN TIP.
• A CHILD OR ADULT CAN TIP THE
RANGE AND BE KILLED.
• FAILURE TO INSTALL THE ANTI-TIP
DEVICE CAN RESULT IN DEATH OR SERIOUS BURNS TO CHILDREN OR ADULTS.
• IF THE RANGE IS MOVED THEN THE
ANTI-TIP DEVICE MUST BE RE-ENGAGED.
7
Dimensions
6
Note: Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and not certified by CSA. Clearances to non-combustible materials must be approved by the authority having jurisdiction. Minimum clearances from
adjacent combustible construction:
Below cooking surface (36” [91.4 cm] and below)
• Sides - 0”
• Top grate support - 36” (91.4 cm)
Above cooking surface (above 36” [91.4 cm])
• Sides - 6” (15.2 cm)
• Within 6” (15.2 cm) side clearance, wall cabinets no deeper than 13” (33.0 cm) must be minimum 18” (45.7 cm) above cooking surface
• Wall cabinets directly above product must be a minimum of 42” (106.7 cm) above cooking surface
• Rear - 0” with 6 ” backguard or high shelf; 0” with island trim and non-combustible rear wall;
• 6” (15.2 cm) with island trim and combustible rear wall
Dual Fuel 30” W. Range
Description
RVDR
Overall width 29-7/8” (75.9 cm)
Overall height To top of side trim – 35-7/8” (91.1 cm) min. 37” (94.0 cm) max.
Legs adjust – 1-1/8” (2.9 cm)
Overall depth from rear
To front of side panel – 25” (63.5 cm)
To front of door – 25-3/4” (65.4 cm)
To front of control panel–27 1/8" (68.9 cm)
To end of knobs – 29" (73.7 cm)
Additions to Overall Height
To top of island trim – add 0” (0.0 cm)
To top of backguard – add 6” (15.2 cm)
To top of high shelf – add 18-3/16” (46.2 cm)
Gas Requirements Shipped standard for Natural gas, field convert with LP conversion kit included with
each unit; Accepts standard residential 1/2” (1.3 cm) ID gas service line
Gas Manifold Pressure Natural 5.0” W.C.P./ Liquid Propane L/P 10.0” W.C.P.
Electrical Requirements 240-208 VAC 60 Hz electrical connection box on product, connect with locally supplied
3-wire, flexible cord or “pigtail” rated 40 amp. 125-250 VAC minimum. Cord must be
agency approved for use with household electric ranges.
Max Amp Usage
240V–25.4 amps 208V–22.9 amps
Surface Burner Rating Natural/LP
Left front Left rear Center Right rear Right front
18,000 BTU Nat/15,800 BTU LP/Propane (5.3 kW Nat/4.6 kW LP/Propane)
8,000 BTU Nat/7,200 BTU LP/Propane (2.3 kW Nat/1.9 kW LP/Propane)
9,000 BTU Nat/8,000 BTU LP/Propane (2.7 kW Nat/2.3 kW LP/Propane) 12,000 BTU Nat/10,800 BTU LP/Propane (3.5 kW Nat/3.2 kW LP/Propane) 18,000 BTU Nat/15,800 BTU LP/Propane (5.3 kW Nat/4.6 kW LP/Propane)
Oven Interior Width 25-5/16” (64.6 cm)
Oven Interior Height 16-1/2” (41.9 cm)
Oven Interior Depth Overall – 19-1/2” (49.5 cm)
AHAM – 16-13/16” (42.7 cm)
Oven Volume Overall AHAM
4.7 cu. ft.
4.1 cu. ft.
Approximate shipping weight
410 lbs.
(184.5 kg)
Specifications
Dual Fuel 30” W. Range
35-7/8”
(91.1 cm) min.
to
37”
(94 cm) max.
25-3/4” (65.4 cm)
45” (114.3 cm)
19-1/4”
(48.9 cm)
25” (63.5 cm)
29” (73.7 cm)
6”
(15.2 cm)
25” (63.5 cm)
27-1/8” (68.9 cm)
Note: Units shown with standard 6” backguard.
29-7/8”
(75.9 cm)
35-7/8”
(91.1 cm) min.
to
(94
37”
.0 cm) max.
Clearance Dimensions (Wood/Composite Overlay)
9
Clearance Dimensions (Proximity to Cabinets)
8
• This range may be installed directly adjacent to existing 36” (91.4 cm) high base cabinets.
IMPORTANT: The side trim MUST be 3/8” (.95 cm) above the adjacent base cabinet countertop. This can be accomplished by raising the unit using the adjustment spindles on the legs.
• The range CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (91.4 cm) high. There must be a minimum of 6” (15.2 cm) side clearance from the range to such combustible surfaces above the 36” (91.4 cm) counter height.
• Within the 6” (15.2 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm), the maximum wall cabinet depth must be 13” (33.0 cm) and wall cabinets within this 6” (15.2 cm) side clearance must be 18” (45.7 cm) above the 36” (91.4 cm) high countertop.
• Wall cabinets above the range must be a minimum of 42” (106.7 cm) above the range cooking surface for the full width of the range. This minimum height requirement does not apply if a range hood is installed over the cooking surface.
The bottom of a standard hood should be 30” (76.2 cm) min. to 36” (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66” (167.6 cm) to 72” (182.9 cm) above the floor. Refer to the range hood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood.
Wall Installation
Island Installation
Note: This range ships standard with a backguard.
Minimum clearance for back wall is 0" with backguard or high-shelf. Note: If a range hood is installed, wall cabinets above the range have a different minimum clearance height.
CAUTION
BURN HAZARD
To avoid risk of personal injury; the use of cabinets for storage
above the appliance may result in a potential burn hazard. Combustible items may ignite, metallic items may become hot and cause burns. If cabinet storage is used, the risk can be reduced by installing a rangehood that projects horizontally a minimum 5" (12.7 cm) beyond the bottom of cabinets.
Note: Minimum clearance for back wall is 0” with backguard or high-shelf.
Important: If installing with an accessory island trim, there must be a minimum of 6” (15.2 cm) clearance from rear of range to a combustible wall.
Note: Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certified by CSA. Clearances to non-combustible materials must be approved by the authority having jurisdiction.
29-7/8”
(75.9 cm)
13” max.
33.0 cm)
(
6” min.
(15.2 cm)
42” min.
(106.7 cm)
Wood/Composite
Wood/Composite
Overlay
66”min.
(167.6 cm)
72”max.
(182.9 cm)
Overlay
24”
(61.0 cm)
or
to
27”
(38.6 cm)
0”
0 cm)
(
30”min.
(76.2 cm)
36”max.
(91.4 cm)
to
8” min.
1
36”
91.4 cm)
(
3/8”
(0.95 cm)
A
Range Width
30” 30” (76.2 cm)
“A”
Dimension
(45.7 cm)
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
30”
(76.2 cm)
6”
(15.2 cm)
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)