Telecommunication Peripheral Products
Technical Practice
PTC-6
6 - Line Positive
Transfer Control
November 18, 1997
Provide Centrex Transfer and Hold
Capabilities Behind PABX’s or Key Systems
The PTC-6 “positive transfer control”
device is the perfect solution for operating
Centrex services from behind a PABX or
key system.
The PTC-6 provides a half second hook
flash to the Centrex line upon detecting a
programmable Touch Tone command (✱✱
or ##). This allows a PABX user to transfer
a caller or place an inbound caller on hold
at the Centrex.
The PTC-6 can also be used to disconnect other equipment such as paging amplifiers
and voice mail systems.
VIKING©
http://www.VikingElectronics.com
E-mail...Sales@VikingElectronics.com
Features Applications
• Provide hook switch transfers to six Centrex
lines
• Stackable to increase capacity
• ✱✱ or ## selectable flash transfers
• Compatible with loop or ground start lines
• Centrex transfers from PABX or electronic key
systems
• Centrex hold of inbound caller
• Touch Tone disconnect of paging and voice mail
systems
• RJ21 female jack provided for easy punchdown
installation
Sales...(715) 386 - 8861
Made in the U.S.A.
Specifications
Power: 120V AC/13.8V AC 1.25 UL listed adapter provided
Dimensions: 210mm x 159mm x 44mm (8.25” x 6.25” x 1.75”)
Shipping Weight: 1.36 kg (3 lbs)
Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95% non-
condensing humidity
Connections: (1) RJ21X female jack
Hook Switch Flash: 500 ms
1 2 3 4
ON
OFF
Dip Switch Settings
Installation
Switch 1
ON
OFF
Note: Switches 2 - 4 are not used
and must remain in the OFF position.
Activation Codes
##
✱✱
(1 - 6) Centrex
Lines
Description
Trunk 1 in
Trunk 2 in
Trunk 3 in
Trunk 4 in
Trunk 5 in
Trunk 6 in
1T/1R
2T/2R
3T/3R
4T/4R
5T/5R
6T/6R
RJ21 Male Connector
(not included)
Pin
26/1
27/2
28/3
29/4
30/5
31/6
Color
W-BL/BL-W
W-O/O-W
W-G/G-W
W-BN/BN-W
W-S/S-W
R-BL/BL-R
PABX/KSU
To Trunk Ports
Trunk 1 out
Trunk 2 out
Trunk 3 out
Trunk 4 out
Trunk 5 out
Trunk 6 out
1T/1R
2T/2R
3T/3R
4T/4R
5T/5R
6T/6R
38/13
39/14
40/15
41/16
42/17
43/18
BK-G/G-BK
BK-BN/BN-BK
BK-S/S-BK
Y-BL/BL-Y
Y-O/O-Y
Y-G/G-Y
Operation
When it has been determined that a call must be transferred through the Centrex lines, the receiving party simply dials a
## or ✱✱ depending on the dip switch settings (see Dip Switch Settings above). The PTC-6 then performs a 500ms
hookswitch flash ahead of the PABX or key system allowing the user to dial the extension number for the transfer.
Product Support Line...(715) 386-8666 Fax Back Line...(715) 386-4345
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking
Electronics, its affiliates and/or subsidiaries assume no responsibility for errors and/or omissions contained in this information. Revisions
of this document or new editions of it may be issued to incorporate such changes.
Printed in the U.S.A. ZF290960 Rev CFax Back Doc # 685