• Operation Instructions 8
Activate Water Pump 8
Power System Features9
Topside Control Instructions 10
Topside Functions 11
Diagnostic Messages 12
Spa Jets and Air Controls 14
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW
ALL INSTRUCTIONS
1.WARNING: To reduce the risk of injury, do not permit
children to use this product unless they are closely supervised
at all times. Keep spa cover locked when not in use.
2.A wire connector is provided on this unit to connect a minimum
No. 8 AWG (8.4mm2) solid copper conductor between this
unit and any metal equipment, metal water pipe or conduit
within 5 feet (1.5m) of the unit.
3.DANGER: Risk of Injury. The suction fittings in this spa are
sized to match the specific water flow created by the pump.
Should the need arise to replace the suction fittings or the
pump, be sure that the flow rates are compatible. Never
operate the spa if the suction fittings are broken or missing.
Never replace a suction fitting with one rated less than the flow
rate marked on the original fitting.
4.DANGER: Risk of Accidental Drowning. Extreme Caution
must be exercised to prevent unauthorized access by children.
To avoid accidents, insure that children cannot use this spa
unless they are supervised at all times.
5. DANGER: Risk of Electric Shock. Install at least 5 feet (1.5m)
from all metal surfaces. As an alternative, a spa may be
installed within 5 feet of metal surfaces if each metal surface is
permanently connected by a minimum No. 8 AWG (8.4mm2)
solid copper conductor to the wire connector on the terminal
box that is provided for this purpose.
6.DANGER: Risk of Electric Shock. Do not permit any
2
electrical appliance, such as a light, telephone, radio or
television within 5 feet (1.5m) of a spa.
7.WARNING: To Reduce the Risk of Injury:
a) Before using your spa you should check the water
temperature with a thermometer that is known to be
accurate. The water temperature in a spa should never
exceed 104°F (40°C). A water temperature of 104°F is
considered safe for a healthy adult. Lower water
temperatures are recommended for young children and
when spa use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for
causing fetal injury during the early months of pregnancy,
pregnant or possibly pregnant women should limit spa water
temperature to 100°F (38°C).
c) The use of alcohol, drugs, or medication before or during
spa use may lead to unconsciousness with the possibility of
drowning.
d) Persons suffering from obesity or with a medical history of
heart disease, low or high blood pressure, circulatory
system problems or diabetes should consult a physician
before using a spa.
e) Persons using medication should consult a physician before
using a spa since some medication may induce drowsiness
while other medications may affect heart rate, blood
pressure and circulation.
8.The causes, symptoms and affects of hyperthermia may be
described as follows:
Hyperthermia occurs when the internal temperature of the body
reaches a level several degrees above the normal temperature
of 98.6°F. The symptoms of hyperthermia include an increase
in the internal temperature of the body, dizziness, lethargy,
drowsiness and fainting.
The effects of hyperthermia include:
• Failure to feel heat
• Failure to recognize the need to exit the spa
• Unawareness of impending hazards
3
• Fetal injury in pregnant women
• Physical inability to exit the spa or hot tub
• Unconsciousness resulting in the potential of drowning
9. WARNING: The use of alcohol, drugs or medication can
greatly increase the risk of fatal hyperthermia. If you suspect
hyperthermia, immediately get medical help, lay the victim on
their back with the head slightly elevated for easier breathing,
cover the body with a blanket and apply ice packs to the
head.
10. Never touch or come in contact with any electrical accessory
when in your spa or when your body is wet.
11. Prior to performing any service to the spa pack, turn off ALL
power to the system at the main power source breaker.
NOTE: A READILY ACCESSIBLE DISCONNECTING MEANS
SHALL BE PROVIDED DURING INSTALLATION.
SAVE THESE INSTRUCTIONS
PERSONAL SAFETY PRECAUTIONS
1. Please use the spa when others are present.
2. Children should have spa access only with the permission and
supervision of an adult.
3.To reduce the risk of child drowning, keep the spa filter clean
and unclogged. Do not modify the suction or filtration
systems.
4.Exercise caution when entering or leaving the spa. When
moving or changing positions, be sure of your footing before
applying your full weight as water refraction can be
misleading.
5.Do not stay in the spa for extended periods of time. Set a
reasonable time limit after which you leave the spa, cool
down, take a shower, relax and then return for another stay in
the spa.
4
INSTALLATION AND SET-UP INSTRUCTIONS
SURFACE AND PAD REQUIREMENTS
• Your new portable spa must be placed on a uniformly firm,
flat and level surface. A concrete pad 4 inches thick is
best.
• In order to prevent flooding of the electrical equipment, the
pad must be such that water will drain away from the spa.
• If your spa is located near sprinklers, adjust or cap them so
as not to hit the siding of the spa.
BALCONIES AND DECK REQUIREMENTS
• Decking must be constructed to support 85 pounds per
square ft.
• Balconies must be constructed to meet current state and
local codes.
• Gates must be self-closing and self-latching.
ELECTRICAL REQUIREMENTS (All Models)
• Your 120-volt spa pack comes installed with a 15-amp rated
dedicated G.F.C.I. cord connected device.
• Your 120-volt spa pack is designed to be “PERMANENTLY
CONNECTED”.
• Use of any extension cord is dangerous and is not to be used in
conjunction with the operation of the spa. Low voltage damage
may result and will void your warranty.
• It is the customer’s responsibility to acquire necessary
permits and to arrange for installation and hook up of
the electrical power.
• Your spa comes set up from the factory to accept 120v
ONLY. Any attempt to remove the factory installed GFCI
cord or alter the voltage will result in voiding your
warranty.
5
SPA STARTUP DIRECTIONS
All Viking Spas require a solid, flat surface.* This is to ensure that the
spa cabinet is not exposed to a pressure stress condition that may
result in cabinet damage and shell cracking. A concrete pad is the
best example of a solid, flat surface, however, wood decking is suitable, provided it can withstand 85# per sq. ft. without deflection.
* FAILURE TO PROVIDE A PROPER, SOLID, FLAT SURFACE
MAY DAMAGE YOUR SPA AND VOID YOUR WARRANTY.
The following procedure should be followed on initial startup and
whenever the spa is drained for maintenance. Read each step in its
entirety before proceeding with that step.
FILL THE SPA WITH WATER
a. Clear all debris from your spa.
b. Remove filter element.
c. Using a garden hose, place hose in filter chamber for filling.
Do not fill higher than three quarters of the way up the skimmer
opening.
d. We DO NOT recommend the use of softened water due
to the potential harm of damaging equipment.
e. As water level rises, check inside equipment compartments for
water leaks. It may be necessary to tighten loose unions and/or
fittings.
f. Make sure T-Handled Gate VALVES at pump and heater are open.
(Fully extended up position).
6
APPLY POWER
a. Apply power by turning on the spa-dedicated circuit breaker.
b. Test the GFCI: push the TEST button and power is cut off. Push
RESET and power is restored. If these do not seem to work,
STOP! Do not use your spa. There is no power, the
GFCI is defective or the equipment is malfunctioning. Only a
LICENSED ELECTRICIAN should do further inspection.
ELECTRICAL SPECIFICATIONS
GENERAL
NOTICE: All spa electrical wiring must be in accordance
to meet NEC (National Electrical Code) state and local
codes.
Wire gauge must be in accordance with NEC
requirements for the distance from current source to spa and
the current rating as stated on the ID label that is attached to
the equipment control enclosure.
GFCI CIRCUIT BREAKER REQUIREMENTS
The existing electrical outlet must have correct currently rating per local
and state codes to accept GFCI from spa.
Breaker
CAPACITY 15 amps
POLES 2
# WIRES 3
7