Viking PI-1A Product Manual

PRODUCT MANUAL
Designed, Manufactured and Supported in the USA
COMMUNICATION & SECURITY SOLUTIONS
Interface Your Paging System with
Nearly Any Phone System!
Features
Viking’s Telecom Paging Interface allows you to provide paging from nearly any phone system in­stead of from a microphone. You can also provide background music and electronic night bell over the audio system.
The PI-1A features a built-in voice activated (VOX) or AC ring activated relay which provides D.P.D.T. contacts for muting background music during pag­ing or to provide an electronic night bell. These contacts are necessary when interfacing with sys­tems such as Panasonic, South Western Bell, In­tertel, etc., which do not provide a paging contact closure.
In the event a paging port is not available, the PI- 1A can provide talk battery to allow connection of the public address system to an unused line/trunk input on the phone system.
The electronic night bell feature is activated by a standard ringing analog PABX/KSU station circuit or by a common audible contact closure provided by an electronic key system. The ring pitch and vol­ume are adjustable allowing you to differentiate be­tween multiple ringing lines.
• Floating 600 ohm output
• Selectable 22V DC talk battery for interfacing with unused phone system line input/trunk ports
• Paging port interface
• Ringing analog line input for night bell
• Contact closure input for night bell
• DPDT normally open and normally closed VOX activated contacts for cutting out background music
• Adjustable VOX contact time-out
• Adjustable VOX trigger sensitivity
• Adjustable ring volume
• Adjustable ring pitch
• Wall mount housing: (2) #6x3/4 panhead screws included
• Integrate your public address system with nearly any phone system
• Cut out background music during paging
• Electronic night bell from ringing line or contact closure
Note: The PI-1A is not compatible with ring trip paging applications. See Viking models FXI-1 (DOD# 494), PA-15 (DOD# 486), or RAD-1A (DOD# 410).
Power: 120V AC/12V DC 500mA, UL listed adapter pro­vided Dimensions: 111mm x 76mm x 36mm (4.38” x 2.97” x
1.38”)
Shipping Weight: .48 kg (1.06 lbs) Environmental: 0°C to 32°C (32°F to 90°F) with 5% to
95% non-condensing humidity Relay Contacts: 30V DC@1A, 110V DC@0.3A, 125V AC @ 0.5A Maximum Ring Output: 0.5V AC RMS no load, 0.4V AC RMS @ 600 ohms VOX Minimum Audio Signal to Activate Relay: At 1KHz with VOX sensitivity POT set to minimum: -17dbm, with POT set to maximum: -37dbm
VOX Time Out Delay: 0.9 sec min / 4.3 sec max Talk Battery: 22V DC
PI-1A
Telecom Paging
Interface
July 11, 2013
Applications
Specifications
www.vikingelectronics.com
Information: (715) 386-8861
VIKING
Installation and Programming
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges.
Step 1. Move the Talk Battery Switch to the PP position.
Step 2. Connect terminals 1 & 2 to the paging port.
Step 3. Connect terminals 3 & 4 to a line level input on your amplifier.
2
1. Paging Port
A. Paging
Features Overview
V
V
Pin Description
12
Positive 12V: A regulated 12VDC output
provided to operated external relays or other devices (use terminal 11 as common).
11
Ground: Used as the ground (common) for
terminals 10 and/or 12.
10
Night Ring Contact Closure Input:
Produces ringing over the paging system when shorted to Ground (terminal 11).
9
Line in: A ringing line will produce ringing
over the paging system.
8
7 Normally closed relay contact
6 Common relay contact
5 Normally open relay contact
4
Audio Out: Floating 600 Ohm output, con-
nect to input of paging amplifier.
3
2
Audio In: Connect to a page port output or
an unused C.O. line input (trunk/FXO port).
1
Switch
Talk
Battery
For Use With:
PP OFF
Paging port output of PABX/ KSU
T ON
Unused Line/ Trunk input of PABX/KSU
To Paging
Port
To Paging Amplifer
Input (600 Ohm)
4: Audio Out 3: Audio Out 2: Audio In 1: Audio In
Power Input: 12V DC
(adapter included)
VOX Time Out Delay: The voice activated contact closures, terminal screws 1, 2, 3 (Aux Relay) and 5, 6, 7 (Primary Relay) on the PI-1A, have an adjustable time out delay from
0.9 to 4.3 seconds. VOX Trigger Sensitivity: Turn the pot to the left to
decrease and the right to increase VOX trigger sensitivity.
PP
Talk Battery Switch
Note: The VOX trigger sensitivity will probably not need to be adjusted unless the PI-1A is disconnecting in the middle of a page (turn clockwise to increase sensitivity if this is the case) or the PI-1A is not disconnecting on periods of silence longer than the VOX time out delay (turn counter clockwise to decrease sensitivity if this is the case).
OX Trigger Sensitivity: Turn the pot to the left to decrease
and the right to increase VOX trigger sensitivity.
OX Time Out Delay: The voice activated contact closures, terminal screws 1, 2, 3 (Aux Relay) and 5, 6, 7 (Primary Relay) on the PI-1A, have an adjustable time out delay from 0.9 to 4.3 seconds.
Auxiliary Relay
The auxiliary relay is a second set of
contacts that work in conjunction with the
primary relay, (terminal screws 5, 6, 7).
J1
3: Normally Closed 2: Common 1: Normally Open
PP
Talk Battery Switch
T
(2) #6x3/4 panhead screws (included)
Power Input: 12V DC
(adapter included)
Ring Pitch Control: Turn the pot to the left to decrease and the right to increase the ringing (warble) pitch.
Ring Volume Control: Turn the pot to the left to decrease and the right to increase the ringing (warble) volume. Minimum: 0mV RMS, maximum: 490mV RMS.