Viking PHK28SS, VCWB301LSS Installation Guide

Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-VIKING1 (845-4641)
or visit the Viking Web site at
Viking Installation Guide
Professional/Custom Panel
Built-In Full Height Wine Cellar
F20904A EN
(101212)
U
L
U
L
C
2
Table of Contents
Warnings & Important Information_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6 Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 7 Cutout Dimensions (Professional/Custom) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 8 Cabinet Information (Professional) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 9 Cabinet Information (Professional w/flush mount trim)_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 12 Cabinet Information (Custom Panel) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 15 Custom Side Panel Dimensions (Professional/Standard Mount)_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 18 Custom Side Panel Dimensions (Custom Panel/Professional w/flush mount trim) _ _ _ _ _ _ _ _ _ _ _ 19
Custom Door Panel Dimensions_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 20
Door Panel Installation (Custom Panel) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 21 Custom Wood Facing Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 22 General Information _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 24
Unpacking & Moving _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 25 Home Security System Connection _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 26
Securing Your Wine Cellar _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 27 Kickplate Installation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 29 Door Stop/Hinge Adjustment _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 30 Performance Checklist _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 31 Service & Registration_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 32
3
IMPORTANT–Please Read and Follow!
• Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage, amperage, and phase is attached to the product.
• To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified people in accordance with all applicable codes and standards, including fire-rated construction.
• The installer should leave these instructions with the consumer who should retain them for local inspector’s use and for future reference.
It is your responsibility to:
• Comply with installation specifications and dimensions
• Properly install unit
• Remove any moldings or decorative panels that prevent the unit from being serviced
• Assure that floor will support unit, door panels and contents (approximately 1200 lbs/540 kg)
• Provide a properly grounded electrical outlet
• Assure that location will permit appliance doors to open 90° minimum
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word“DANGER” or “WARNING.” These words mean:
DANGER
Hazards or unsafe practices which
WILL result in severe personalinjury
or death.
WARNING
Hazards or unsafe practices which
COULD result in minor personal injury
or property damage.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
CAUTION
Hazards or unsafe practices
which COULD result in severe
personal injury or death.
4
IMPORTANT–Please Read and Follow!
WARNING
TIP OVER HAZARD
Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions.
Use two or more people to move and install appliance. Failure to do so can result in death or serious injury.
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power or turn power disconnect switch to OFF position before removing top grille. Failure to do so can result in death or electrical shock.
Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent tipping. Use cardboard shipping material or plywood under unit until it is installed in the operating position to protect floor surface.
5
IMPORTANT–Please Read and Follow!
A GFI
shall be used if required by NFPA-70 (National Electric Code), federal/state/local
laws, or local ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture.
• Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below.
If the use of a GFI is required
, it should be:
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
6
Dimensions
30” Professional
30” Custom
7
Specifications
Description VCWB301/Standard Mount VCWB301/Flush Mount
Overall width 30” (76.2 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max.
Overall depth from rear To rear edge of side trim: 22-3/16” (56.4 cm)
To front of door: 24-1/32” (61.0 cm)
To end of handle bracket: 27” (68.6 cm)
23-13/16” (60.5 cm)
To front of door: 24-1/32” (61.0 cm)
To end of handle bracket: 27” (68.6 cm)
Cutout width 29-5/8” (75.2 cm) 30” (76.2 cm)
Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max.
Cutout depth 24” (61.0 cm) min.
Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 2.3 amps
Overall capacity 150 bottles
Approximate shipping w eight 560 lbs. (252 kg)
NOTE: Flush Mount Trim is shipped with the wine cellar in a box marked “Refrigerator Trim Parts ­DO NOT DISCARD”.
Description FDWB301
Overall width 30” (76.2 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max.
Overall depth from rear To front edge of side trim: 23-13/16” (60.5 cm)
To front edge of cabinet side trim: 24-3/4” (62.9 cm)
To front edge of door handle: Varies
Cutout width 30” (76.2 cm)
Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max.
Cutout depth 25” (63.5 cm) - can be installed in 24” (61.0) cm deep openings; door faces
and top grille will protrude 3/4” (1.9 cm) into room.
Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 2.3 amps
Overall capacity 150 bottles
Approximate shipping w eight 560 lbs. (252 kg)
9-5/16”
(23.6 cm)
70”
(177.5 cm)
29”
(73.7cm)
30”
(76.2 cm)
22-3/16”
Standar
23-13/16”
Flush Mount
24-1/32”
(61.0 cm)
27”
(68.6 cm)
(56.4 cm)
Mount/
d
(60.5 cm)
82-7/8”
(210.5 cm)
min.
to
84-1/16”
(213.5 cm)
max.
9-5/8”
(24.4 cm)
70”
(177.5 cm)
30”
(76.2 cm)
29”
(73.7 cm)
23-13/16”
(60.5 cm)
cm)
24-3/4”
(62.9
S
E
I
R
A
V
82-7/8”
(210.5 cm)
min.
to
84-1/16”
(213.5 cm)
max.
8
Cutout Dimensions (Professional/Custom)
9
1-1/2”
(3.8 cm)
Cabinet Information (Professional)
Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/16” (5.2 cm) from the cabinet face. The handle protrudes an additional 2-1/2” (6.4 cm) into the room.
TOP VIEW
2” x 4” Mounting Board [1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)] Attached to anti-tip mounting bracket Note: If unit is installed deeper than 24” (61.0 cm), then shim behind anti-tip bracket thickness by the same amount
1-1/2”
1-1/2”
(3.8 cm)
(3.8 cm)
3-1/2”
(8.9 cm)
8-1/4” (20.9 cm)
Anti-tip mounting brackets attached to wall studs
84-1/16” (213.5 cm) max. anti-tip board and opening height
to
82-7/8” (210.5 cm) min. anti-tip board and opening height
4”
(10.2 cm)
Electrical outlet location
Wall
73-3/4”
(187.3 cm)
24” (61.0 cm) Professional
25” (63.5 cm) Custom Panel*
29-5/8” (75.2 cm) Standard Mount
30” (76.2 cm) Flush Mount Only
*Custom Panel models fit flush in 25”
(63.5 cm) deep cabinet openings. They can be installed in standard 24” (61.0 cm) deep openings. The door faces and top grille will protrude 3/4” (1.9 cm) into the room.
24”
(61.0 cm)
standard
cabinet
depth
2-1/16” (5.2 cm) offset
3/4” (1.9 cm) full end panel
5/16”
(0.8 cm)
1-13/16” (4.6 cm)
Door
10
Cabinet Information (Professional)
Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/16” (5.2 cm) from the cabinet face. The handle protrudes an additional 2-1/2” (6.4 cm) into the room.
TOP VIEW
Cabinet Information (Professional)
TOP VIEW
111213
1-13/16”
(4.6 cm)
space if 24”
(61.0 cm)
standard cabinet
depth is used
Door
Wall
2-1/16” (5.2 cm) offset
3/4” (1.9 cm) full end panel
Countertop overhang
24”
(61.0 cm)
standard
cabinet
depth
1-13/16”
(4.6 cm)
space if 24”
(61.0 cm)
standard cabinet
depth is used
Door
Wall
2-1/16” (5.2 cm) offset
3/4” (1.9 cm) full end panel
Partial overlay cabinet door
24”
(61.0 cm)
standard
cabinet
depth
Loading...