Control Panels _________________________________________________________________________ 21
Service & Registration __________________________________________________________________ 22
2
IMPORTANT – Please Read and Follow!
• Make sure that incoming voltage is the
same as unit rating. An electric rating
plate specifying voltage, frequency,
wattage, amperage, and phase is
attached to the product.
• To reduce the risk of re, electrical shock,
or injury to persons, installation work
and electrical wiring must be done by
a quali ed technician in accordance
with all applicable codes and standards,
including re-rated construction.
• The installer should leave these
instructions with the consumer who
should retain them for local inspector’s
use and for future reference.
For additional information or installation
videos, visit our website at www.
vikingrange.com in the US or brigade.ca in
Canada.
Your safety and the safety of others is very
important.
We have provided many important safety
messages in this manual and on your appliance.
ALWAYS read and obey all safety messages.
This is the safety alert symbol. This
symbol alerts you to hazards that
can kill or hurt you and others.
All safety messages will be preceded by the
safety alert symbol and the word “DANGER” or
“WARNING.” These words mean:
DANGER
You will be killed or seriously injured if you
don't follow instructions.
WARNING
You can be killed or seriously injured if you
don't follow instructions.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
It is your responsibility to:
• comply with installation speci cations and dimensions.
• properly install unit.
• remove any moldings or decorative panels that prevent the unit from being serviced.
• make sure that you have these materials (not provided with your unit), which are necessary
for proper installation:
• 1/4” (6 mm) copper tubing with shuto valve
• 1– Saddle valve (do not use self-piercing feature of the valve)
• assure that oor will support unit, door panels and contents (approximately
1200 pounds [540 kg]).
• provide a properly grounded electrical outlet.
• assure that location will permit appliance doors to open 90º minimum.
A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local
ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to
any signi cant sources of water or moisture.
• Viking Range, LLC will
installed properly or do not meet the requirements below.
If the use of a GFI is required, it should be:
• Of the receptacle type (breaker type or portable type
• Used with permanent wiring only (temporary or portable wiring
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size
recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard)
• In good condition and free from any loose- tting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
NOT warranty any problems resulting from GFI outlets which are not
NOT recommended)
NOT recommended)
NOT
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power or turn
power disconnect switch to
OFF position before removing
top grille. Failure to do so can result in death or
electrical shock.
Power On/O Switch
Your unit is shipped with the power switch on. When rst plugged in, the
display will ash. Push any button to initiate display.
The power on/o switch is located to the left of the center behind the
access panel. It is used to turn the power o when cleaning or servicing
the refrigerator.
To turn power o , remove the access panel. Press the power on/o switch
to the o position.
To turn power on, press power on/o switch to the on position. Replace
access panel.
and secured per installation instructions.
Use two or more people to move and install
appliance. Failure to do so can result in death or
serious injury.
WARNING
TIP OVER HAZARD
Appliance is top heavy and tips
easily when not completely
installed. Keep doors closed until
appliance is completely installed
access panel
B
4
Dimensions (Integrated Bottom-Freezer)
83-15/16”
(213.2 cm)
36”
(91.4 cm)
50-1/2”
(128.3 cm)
22-1/2”
(57.2 cm)
24-5/8”
(62.5 cm)
27-3/8”
(69.5 cm)
ModelDimension ADimension B*
VBI7360/CVBI7360
FBI7360/CFBI7360
MVBI7360/CMVBI7360
12-1/8”
(30.8 cm)
17-1/16”
(43.3 cm)
4-1/16” (10.3 cm)
27-3/8" (69.5 cm)24-3/4" (62.9 cm)
N/A24" (61.0 cm)
27" (68.5 cm)24-3/4" (62.9 cm)
*To outside of door panel
5
5
Speci cations (Integrated Bottom-Freezer)
36” Integrated Refrigerator/Freezer
DescriptionVBI7360 / CVBI7360MVBI7360 / CMVBI7360
Overall width36" (91.4 cm)
Overall height (from bottom)83-15/16" (213.2 cm) min to 84-3/4" (215.7 cm) max
Overall depth from rear To front edge kickplate: 22-1/2” (57.2 cm)
To front of door panel: 24-3/4” (62.9 cm)
To front of handle endcap:
27-3/8" (69.5 cm)
Cutout width 36" (91.4 cm)
Cutout height84-3/16" (213.8 cm) min to 85-3/16" (216.3 cm) max
Cutout depth 25” (63.5 cm) min.
Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with