Totally Eliminate Paging Feedback
Even the best designed paging systems can experience feedback. Now you can eliminate annoying feedback over your paging speakers with Viking’s model FBI-1A digital anti- feedback paging interface.
The FBI-1A utilizes state of the art digital recording technology to record the “live” page from a phone system’s paging port output or unused trunk port. The FBI-1A then immediately plays back the recorded page once
oor twice (selectable) over the paging system.
Pages of up to 16 seconds (expandable to 60 seconds) can be stored and the FBI-1A automatically adjusts to the page length for faster processing. In addition, the FBI-1A can be programmed to provide pre-page and post-page alert tones.
http://www.VikingElectronics.com
VIKING©
E-mail...Sales@VikingElectronics.com
Features Applications
• High quality (64K) digital message storage
• High output - 2V RMS into 600 ohms
16 second record time expands to 1 minute using an ERAM-60 Memory Kit
• Compatible with Paging ports or Trunk ports
• Activate recording from VOX detection, contact closure or loop detect (Trunk mode only)
VOX sensitivity adjustment
• Selectable page repeat
Selectable pre-page alert tone
• Selectable post-page alert tone
Adjustable alert tone volume
• N.O./N.C. relay contacts control paging system
• Record/Playback LED indicator
• Compatible with virtually all paging and telephone systems
Eliminate Paging Feedback in:
• Warehouses, Factories, Offices
• Retail Stores, Hotels, Airports
• Stadiums, School Gymnasiums, Pools
• Casinos, Bingo Halls, Dining Establishments
• Other large noisy areas
Sales...(715) 386 - 8861
Specifications
Power: 120V AC/13.8V AC 1.25A, UL listed adapter provided Dimensions: 133mm x 89mm x 44mm (5.25” x 3.5” x 1.75”) Shipping Weight: 0.73 kg (1.6 lbs) Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95% non-
condensing humidity
Sampling Rate: 64K (equivalent) Maximum Page Length: 16 seconds (expandable to 60 seconds with Viking model ERAM-60 memory upgrade kit) Output Impedance: 600 ohm Maximum Audio Output: 2V RMS (driving a 600 ohm load) Talk Battery: 24V DC (Trunk mode only) Connections: 10 position screw terminal block
Installation
VIKING
PAGING
Paging Volume
(see Programming section H)
120V AC
Mode Switch (see Programming section A) Page LED - Lights during recording and playback
(see Programming section I) Page Alert Tone Volume (see Programming section G) Paging Options (see Programming section C)
Phone System
(PABX/KSU)
600 ohm paging port or unused trunk port
VOLUME
MAX
MIN MAXMIN
POWER 13.8V AC
PAGING OPTIONS
PAGE REPEAT
PRE-PAGE TONE
POST PAGE TONE
MODE SWITCH
PAGING
TRUNK
PORT
PORT
PAGE
LED
MODEL FBI-1A
©
VIKING
ELECTRONICS
HUDSON, WI 54016
DIGITAL ANTI-FEEDBACK
PAGING INTERFACE
600 OHM
AUDIO OUT
PAGING
INPUT
12345678 910
PAGE TONE
VOL
123
VOX
SENSITIVITY
PAGING
CONTROL
OUTPUT
COMMON
CANCEL PAGE
RECORD PAGE
N.O.
600 ohm
page output
(to paging amp input)
VOX Sensitivity - Voice Operated
Recording Adjustment (see Programming section B)
Paging Control Output (see Programming section D)
N.C. relay contact COM. relay contact N.O. relay contact
Cancel Page (see Programming section E) Record Page (see Programming section F) Common
VIKING©
POWER 13.8V AC
MODE SWITCH
TRUNK/PAGING PORT
PAGING
MUSIC
INPUT
INPUT
MODEL CPA-7B
PAGING VOLUME
VIKING
ELECTRONICS
HUDSON, WI 54016
GENERAL PURPOSE TELECOM
PAGING SYSTEM
SPEAKERS
600 OHM
1 2 3 4 5 6 7 8 9 10
RING TRIP
TIME OUT
RING/ALERT TONE
VOLUME
COMMON
AUDIO OUT
NIGHT BELL
PAGE TRIGGER
TALK BATTERY
PAGE W/ COMMON AUDIBLE
RING TRIP PAGE W/ NIGHT BELL
Model CPA-7B
Paging Amplifier
(not included)
Programming
A. Mode Switch
In the Trunk Port position, 24V talk battery is supplied for connecting the FBI-1A paging input to a phone system’s unused trunk port. In the Paging Port position, a 600 ohm audio input is supplied for connecting to a phone system’s paging port output.
B. VOX Sensitivity
If the FBI-1A is installed on a phone system’s paging port that does not supply a page control contact (normally open relay contact that closes while the paging port is activated) the VOX (Voice Operated Recording) feature may be used. The VOX sensitivity may require adjustment. Rotate the POT clockwise to increase the sensitivity for low level input signals (see Programming section I).
Note: The VOX (Voice Operated Recording) feature is not used in the trunk mode or when a page control contact is connected to the record page input of the FBI-1A to trigger the recording. In these applications, set the VOX sensitivity to the minimum level.
C. Paging Options
1. Post-page Tone - The FBI-1A will output a short (high) beep after the entire page has been played, indicating
that it is ready to record a new page.
2. Pre-page Tone - The FBI-1A will output a (low) beep before the page, alerting listeners of the oncoming page.
3. Page Repeat - The FBI-1A will play the recorded page twice, eliminating the need to repeat pages.
Note: To disable a feature, move the corresponding DIP switch to the OFF position.
DIP Switch
1 - ON 2 - ON 3 - ON
Feature
Enables post page tone Enables pre-page tone Play message twice
1
2
3
123
ON
OFF
VIKING
PAGING VOLUME
MAXMIN MAXMIN
DIGITAL ANTI-FEEDBACK
PAGING INTERFACE
POWER 13.8V AC
PAGING OPTIONS
PAGE REPEAT PRE-PAGE TONE
POST PAGE TONE
MODE SWITCH
PAGING
TRUNK
PORT
PAGE
PORT
TONE
PAGE
VOL
LED
123
MODEL FBI-1A
©
VIKING
ELECTRONICS
HUDSON, WI 54016
600 OHM
AUDIO OUT
PAGING
INPUT
12345678 910
VOX
SENSITIVITY
COMMON
RECORD PAGE
PAGING
CONTROL
OUTPUT
CANCEL PAGE
Loading...
+ 2 hidden pages