Telecommunication Peripheral Products
Anti-Feedback Paging
Technical Practice
FBI-1A
Interface
August 4, 1999
Totally Eliminate Paging Feedback
Even the best designed paging systems can
experience feedback. Now you can eliminate
annoying feedback over your paging speakers
with Viking’s model FBI-1A digital anti-
feedback paging interface.
The FBI-1A utilizes state of the art digital
recording technology to record the “live” page
from a phone system’s paging port output or
unused trunk port. The FBI-1A then
immediately plays back the recorded page once
oor twice (selectable) over the paging system.
Pages of up to 16 seconds (expandable to 60 seconds) can be stored and the FBI-1A
automatically adjusts to the page length for faster processing. In addition, the FBI-1A
can be programmed to provide pre-page and post-page alert tones.
http://www.VikingElectronics.com
VIKING©
E-mail...Sales@VikingElectronics.com
Features Applications
• High quality (64K) digital message storage
• High output - 2V RMS into 600 ohms
• 16 second record time expands to 1 minute
using an ERAM-60 Memory Kit
• Compatible with Paging ports or Trunk ports
• Activate recording from VOX detection, contact
closure or loop detect (Trunk mode only)
• VOX sensitivity adjustment
• Cancel page feature
• Selectable page repeat
• Selectable pre-page alert tone
• Selectable post-page alert tone
• Adjustable alert tone volume
• N.O./N.C. relay contacts control paging
system
• Record/Playback LED indicator
• Compatible with virtually all paging and
telephone systems
Eliminate Paging Feedback in:
• Warehouses, Factories, Offices
• Retail Stores, Hotels, Airports
• Stadiums, School Gymnasiums, Pools
• Casinos, Bingo Halls, Dining Establishments
• Other large noisy areas
Sales...(715) 386 - 8861
Specifications
Power: 120V AC/13.8V AC 1.25A, UL listed adapter provided
Dimensions: 133mm x 89mm x 44mm (5.25” x 3.5” x 1.75”)
Shipping Weight: 0.73 kg (1.6 lbs)
Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95% non-
condensing humidity
Sampling Rate: 64K (equivalent)
Maximum Page Length: 16 seconds (expandable to 60 seconds
with Viking model ERAM-60 memory upgrade kit)
Output Impedance: 600 ohm
Maximum Audio Output: 2V RMS (driving a 600 ohm load)
Talk Battery: 24V DC (Trunk mode only)
Connections: 10 position screw terminal block
Installation
VIKING
PAGING
Paging Volume
(see Programming section H)
120V AC
Mode Switch (see Programming section A)
Page LED - Lights during recording and playback
(see Programming section I)
Page Alert Tone Volume (see Programming section G)
Paging Options (see Programming section C)
Phone System
(PABX/KSU)
600 ohm paging port
or unused trunk port
VOLUME
MAX
MIN MAXMIN
POWER 13.8V AC
PAGING OPTIONS
PAGE REPEAT
PRE-PAGE TONE
POST PAGE TONE
MODE SWITCH
PAGING
TRUNK
PORT
PORT
PAGE
LED
MODEL FBI-1A
©
VIKING
ELECTRONICS
HUDSON, WI 54016
DIGITAL ANTI-FEEDBACK
PAGING INTERFACE
600 OHM
AUDIO OUT
PAGING
INPUT
12345678 910
PAGE
TONE
VOL
123
VOX
SENSITIVITY
PAGING
CONTROL
OUTPUT
COMMON
CANCEL PAGE
RECORD PAGE
N.O.
600 ohm
page output
(to paging amp input)
VOX Sensitivity - Voice Operated
Recording Adjustment
(see Programming section B)
Paging Control Output
(see Programming section D)
N.C. relay contact
COM. relay contact
N.O. relay contact
Cancel Page (see Programming section E)
Record Page (see Programming section F)
Common
VIKING©
POWER 13.8V AC
MODE SWITCH
TRUNK/PAGING PORT
PAGING
MUSIC
INPUT
INPUT
MODEL CPA-7B
PAGING
VOLUME
VIKING
ELECTRONICS
HUDSON, WI 54016
GENERAL PURPOSE TELECOM
PAGING SYSTEM
SPEAKERS
600 OHM
1 2 3 4 5 6 7 8 9 10
RING TRIP
TIME
OUT
RING/ALERT TONE
VOLUME
COMMON
AUDIO OUT
NIGHT BELL
PAGE TRIGGER
TALK BATTERY
PAGE W/ COMMON AUDIBLE
RING TRIP PAGE W/ NIGHT BELL
Model CPA-7B
Paging Amplifier
(not included)
Programming
A. Mode Switch
In the Trunk Port position, 24V talk battery is supplied for connecting the FBI-1A paging input to a phone system’s
unused trunk port. In the Paging Port position, a 600 ohm audio input is supplied for connecting to a phone
system’s paging port output.
B. VOX Sensitivity
If the FBI-1A is installed on a phone system’s paging port that does not supply a page control contact (normally
open relay contact that closes while the paging port is activated) the VOX (Voice Operated Recording) feature may
be used. The VOX sensitivity may require adjustment. Rotate the POT clockwise to increase the sensitivity for low
level input signals (see Programming section I).
Note: The VOX (Voice Operated Recording) feature is not used in the trunk mode or when a page control contact is
connected to the record page input of the FBI-1A to trigger the recording. In these applications, set the VOX
sensitivity to the minimum level.
C. Paging Options
1. Post-page Tone - The FBI-1A will output a short (high) beep after the entire page has been played, indicating
that it is ready to record a new page.
2. Pre-page Tone - The FBI-1A will output a (low) beep before the page, alerting listeners of the oncoming page.
3. Page Repeat - The FBI-1A will play the recorded page twice, eliminating the need to repeat pages.
Note: To disable a feature, move the corresponding DIP switch to the OFF position.
DIP Switch
1 - ON
2 - ON
3 - ON
Feature
Enables post page tone
Enables pre-page tone
Play message twice
1
2
3
123
ON
OFF
VIKING
PAGING
VOLUME
MAXMIN MAXMIN
DIGITAL ANTI-FEEDBACK
PAGING INTERFACE
POWER 13.8V AC
PAGING OPTIONS
PAGE REPEAT
PRE-PAGE TONE
POST PAGE TONE
MODE SWITCH
PAGING
TRUNK
PORT
PAGE
PORT
TONE
PAGE
VOL
LED
123
MODEL FBI-1A
©
VIKING
ELECTRONICS
HUDSON, WI 54016
600 OHM
AUDIO OUT
PAGING
INPUT
12345678 910
VOX
SENSITIVITY
COMMON
RECORD PAGE
PAGING
CONTROL
OUTPUT
CANCEL PAGE