Viking E-30-PT, TBB-1, E-30-PT-EWP Technical Practice

Page 1
PPrraaccttiicce
e
T
T
EELLEECCOOM
M
S
S
OOLLUUTTIIOONNSSFFOORRTTHHE
E
221
1
SST
C
C
EENNTTUURRY
Y
TECHNICAL
TECHNICAL
Provide Reliable and Intelligent
Communication - In Noisier Locations
The E-30-PT is designed to provide quick and reliable communication in noisier areas. The mic sensitivity is set to a low level until the TALK button is pressed then it is raised to a normal level. In this way, the E- 30-PT assures that the called party’s voice will be broadcast over the speaker. In applications where the background noise can be loud-
er than the person calling, a handset type phone is recommended.
The E-30-PT features non-volatile memory, a built in dialer, and intelli­gent call progress detection for automatic hang-up when the call is completed. The E-30-PT can be programmed to dial up to 5 different numbers on ring no answer or busy and can be configured to dial these numbers until answered.
FFeeaattuurrees
s
Power: Telephone line powered. Minimum 24V DC talk battery voltage, with a minimum loop current of 20mA loop (room temp), or 25mA (extended cold temp range). Loop current may be boosted on low current lines with a Viking Model TBB-1 talk bat­tery booster (Fax Back # 630).
Minimum Ring Voltage: 90VAC RMS Dimensions: Overall-127mm x 127mm x 57mm (5” x 5” x 2.25”),
Plastic Electrical Box-102mm x 102mm x 54mm (4” x 4” x 2.12”)
Shipping Weight: 1 Kg (2.2 lbs) Operating Temperature: -26°C to 54°C (-15°F to 130°F) Humidity - E-30-PT: 5% to 95% non-condensing Humidity - E-30-PT-EWP: Up to 100% condensing Connections - E-30-PT: RJ11 jack Connections - E-30-PT-EWP: Gel-filled butt connectors
SSppeecciiffiiccaattiioonns
s
The E-30-PT-EWP shares all of the features of the E-30-PT in addition to Enhanced Weather Protection (EWP) for installation in harsh environments. EWP products feature rubber gaskets and boots, hand sol­dered silicon sealed connections, gel-filled butt connectors, as well as urethane potted circuit boards with weather sealed, field-adjustable trim pots and DIP switches for easy on-site programming.
E-30-PT /
E-30-PT /
E-30-PT-EWP
E-30-PT-EWP
Speaker Phone with
Push To Talk Button
November 28, 2007
• Push to talk button
• Phone line powered
• Vandal resistant, stainless steel faceplate with heavy-duty metal call buttons
• Non-volatile E
2
memory (no batteries required)
• Touch Tone or pulse dialing
• Programmable to dial up to 5 numbers on busy or ring no answer
• Red off-hook LED indicator
• Hangs up on CPC, silence, busy signal, return to dial tone, time out or a Touch Tone command
• Programmable to auto-answer on incoming calls
• Remotely programmable
• Extended temperature range (-15°F to 130°F)
• Flush mountable using included plastic rough-in box
E-30-PT-EWP conforms to NEMA requirements
E-30-PT-EWP has Enhanced
Weather protection
• Optional VE-5x5 surface mount back box
AApppplliiccaattiioonns
s
Non-ADA Hot-Line Phones for:
• Terminals • Stadiums
• Parking lots/ramps • Convention centers
• ATM machines
Gate and Door Entry Phones for:
• Business lobbies
• Vehicular and pedestrian gates
• Residences
E-30-PT/E-30-PT-EWP
shown in optional VE-5x5
?
Need More Information on EWP?
Call (715) 386-4345 and select 859.
?
Need More Information on VE-5x5?
Call (715) 386-4345 and select 424.
CAUTION - When installing on an analog extension of a phone system:
Some phone systems do not conform to analog telecom standards and might not be compatible with the E-30-PT phones. For a detailed description of the telephone line specifications required for any of the E-30-PT phones, retrieve Fax Back Document 869.
PPhhoonnee......771155..338866..8888661
1
Page 2
Front View of Optional
VE-5x5 (not included)
2.25”
Condensation
Drain Hole
5.14”
5.22”
3.25”
Rear View of VE-5x5
(not included)
(4) 0.38” diameter (for gooseneck mounting)
(4) 0.2 x 0.43 slots for double gang box
(2) 0.2 x 0.43 slots for single gang box
(1) .74" dia
3.0” 3.3”
3.0”
Wall Stud
Front View of
Plastic Rough-In
Box (included)
Wire knock out
(2) Standard flat head dry wall (sheet rock) screws (not included)
10.50”
39.5”
41.41”
3.81”
* Adhere gasket to front panel, centering over mounting holes
CALL
PUSH TO
TALK
CALL
CONNECTED
4.0"
"Push to Talk" Button
Call Connected Red LED
"Call" Button
5.0”
2.1”
(4) 6-32 X 3/4” stainless steel, flat head, hexdrive, screws (included)
Condensation Drain Hole
Side View of
VE-GNP
(not included)
IInnssttaallllaattiioon
n
PPrrooggrraammmmiinng
g
Step 1. Move DIP switch 2 to the ON position (sets unit to answer incoming calls - see section F).
Step 2. From a Touch Tone phone call the line attached to the E-30-PT.
Step 3. When the E-30-PT answers, enter the 6-digit security code (factory set to 845464 - see section C). A double beep
should then be heard indicating you have entered the programming mode.
2. Without the Security Code
A. Accessing the Programming Mode
1. Using the Security Code
Step 1. Move DIP switch 2 to the ON position (sets unit to answer incoming calls - see section F).
Step 2. Move DIP switch 3 to OFF (incoming calls enter the programming mode without security code - see section F).
Step 3. From a Touch Tone phone call the line attached to the E-30-PT.
Step 4. When the E-30-PT answers, a double beep will be heard and you will automatically enter the programming mode.
Step 5. When finished programming, move DIP switch 3 back to the ON position (see section F).
Note: If a valid memory position is entered, a double beep will be heard, four beeps indicate an error.
The optional VE-5x5 Surface Mount Box is designed to be surface mounted to a single gang box, double gang box or VE-GNP gooseneck pedestal (right).
Important: The E-30-PT will NOT mount to a standard double gang box.
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges. Contact Panamax at (800) 472-5555 or Electronic Specialists Inc. at (800) 225-4876.
Caution: When warm air comes in contact with cold surfaces, such as outside walls and conduits, it causes condensation. To prevent condensation from accumulating inside the E-30-PT always bring conduit into the bottom of the unit. If this is not possible, drill a 1/4” diameter hole in the bottom of the gray plastic box.
*Note: Peel off paper liner and adhere gasket to the back of the faceplate, centering it over the four corner mounting holes. Be careful to position the mod­ular jack inside the chassis as not to damage the components on the circuit board.
or
C.O. Line
Analog
PABX/KSU
Station
or
C.O. Line
Analog
PABX/KSU
Station
Rear View of a Standard
E-30-PT Phone
Rear View of an
E-30-PT-EWP Phone
RJ11
** Gel-Filled
Butt
Connectors
(included)
Red
Green
Spade Terminal
(included)
* Earth
Ground
(optional)
Spade Terminal
(included)
* Earth
Ground
(optional)
!
Note: The plastic rough-in box (part # 259576) may be purchased separately in advance. Go to www.vikingelectronics.com and click on “Spare Parts”.
?
Need More Information on VE-5x5 or VE-GNP?
Call (715) 386-4345 and select 424.
?
Need More Information on the DLE-200B?
Call (715) 386-4345 and select 605.
The E-30-PT phone can be programmed from any Touch Tone phone using a C.O. line, analog PABX/KSU station, or a DLE-200B Line Simulator.
* Note: To increase surge protection, loosen the PCB mounting screw labeled (as shown above) and fasten a wire with spade terminal (included) from the mounting screw to Earth Ground (grounding rod, water pipe, etc.)
** Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches. Do not strip wires prior to terminating.
Page 3
E. Timing/Dialing Options (Memory Location #18)
There are six positions in the timing/dialing options. To program these options, enter the six desired timing/dialing dig­its followed by #18. The six available timing/dialing options are defined as shown below.
Dial: A +B+C+D+E+F+#+1+8
Factory Default Setting:2+3 +4+1+ 1+1
Talk/Listen Delay Call Length Silence Time Out Dial Next Number on Ring No Answer Dial Next Number on Busy Pulse Dial Speed
Enter Timing/Dialing Settings Here:
A B C D E F
#18
Setting A - Talk/Listen Delay
This feature selects switching time between talk and listen modes (VOX switching time). Use chart at the right. * Note: The factory
default is .2 seconds.
Setting B - Call Length Time Out
This feature selects the maximum length of time that calls can be connected. Programmable in increments of 1 minute up to a maximum of 9 minutes (Touch Tones 1 - 9). Program 0 in this location to disable the call length time out. With the call length disabled, the E-30-PT phone must rely on CPC, busy, silence or return dialtone to hang-up. Use chart at the far right. *Note: The factory default is 3 minutes.
Touch
Tone
1 2 3 4 5 6 7 8 9
Talk/Listen
Delay
.1 sec .2 sec * .3 sec .4 sec .5 sec .6 sec .7 sec .8 sec .9 sec
Touch
Tone
0 1 2 3 4 5 6 7 8 9
Call Length
Time Out
Disabled
1 min 2 min 3 min* 4 min 5 min 6 min 7 min 8 min 9 min
D. Speed Dial Numbers (Memory Locations #00 - #04)
Note: Up to 20 digits can be stored in each dial position. Special features such as pause, mode change, Touch Tone
,
and # count as single digits.
The speed dial number programmed in location #00 is the telephone or extension number that is dialed when the “Call” button is first pressed. Additional speed dial numbers will be dialed when there is no answer or a busy signal is detected and the next number redial features are activated. The E-30-PT will cycle through the pro­grammed speed dial numbers until answered. To program, enter the desired speed dial number followed by the memory location number (#00 - #04).
To clear a speed dial location, simply enter the memory location (#00 - #04) alone. The E-30-PT is factory set with no speed dial number programmed.
To Program:
,
#
4 second pause
switch to pulse mode
0, 1, 2...9
Enter:
,,
,#
,7
,6
0, 1, 2...9
B. Quick Programming Features
First speed dial number ...........................................................................................
Second speed dial number ......................................................................................
Third speed dial number ..........................................................................................
Fourth speed dial number ........................................................................................
Fifth speed dial number ...........................................................................................
To add a
, at any point in the dialing string ...............................................................
To add a # at any point in the dialing string ...............................................................
To add a four second pause at any point in the dialing string ....................................
Toggle between Touch Tone and Pulse dialing .........................................................
Timing/Dialing options (factory set to 234111) .........................................................
Change security code (factory set to 845464) .........................................................
0-20 digits 0-20 digits 0-20 digits 0-20 digits 0-20 digits
,, ,# ,7 ,6
6 digits (0-9) 6 digits (0-9)
#00 #01 #02 #03 #04
#18 #19
Enter Digits
then then then then then
then then
- then -
Enter Memory Location
C. Security Code (memory location #19)
The security code allows the user/installer to program the E-30-PT phone while DIP switch 3 is in the ON (normal) posi­tion. The factory set security code is 845464 (V-I-K-I-N-G). It is recommended that the factory set security code be changed. Example: To store 123456 as the security code:
Enter Your Security Code Here:
#19
Step 1. Access programming as shown is Programming section A.
Step 2. Enter 123456 #19..
Step 3. Hang-up.
Note: The security code must be 6 digits and cannot include a ,or a #.
Page 4
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.
Fax Back Doc 214
ZF302280 Rev A
Printed in the U.S.A.
OOppeerraattiioon
n
PPrroodduuccttSSuuppppoorrttLLiinnee......771155..338866..8866666
6
FFaaxxBBaacckkLLiinnee......771155..338866..4433445
5
F. DIP Switch Programming/Speaker and Microphone Adjustments
Two POTs are provided to increase or decrease speaker volume and microphone sensitivity. In certain noisy locations the microphone sensitivity may need to be decreased as shown below. Caution: Setting the microphone gain too high
may cause distorted audio, prevent the distant party from breaking over and inhibit second number redialing.
Switch
1
1
2
2
3
3
Position
ON
OFF
ON
OFF
ON
OFF
Description
“Call” button alternately connects and disconnects calls (factory setting)
“Call” button connects calls only
Incoming calls answered (factory setting)
Incoming calls are not answered
Normal operation mode (factory setting)
Learn mode - Any incoming calls are auto­matically entered into the programming mode (no security code required). Use this option if you have forgotten your security code.
To Program the E-30-PT Phone...
...to store 123456 as the security code
...to store a Touch Tone 9, a four second pause and then a pulse dialed 333-4444 in the first speed dial position
...to store 555-1234 in the second speed dial position
Step 2 - Enter Digits:
1 2 3 4 5 6 # 1 9
9
,7 ,6 3 3 3 4 4 4 4 # 0 0
5 5 5 1 2 3 4 # 0 1
Step 1 -
See Section A
Enter Programming
Enter Programming
Enter Programming
When the “Call” button is pressed, the E-30-PT phone goes off-hook, and dials a pre-programmed telephone number. The front panel LED will light any time the phone is off hook. In the event that the line is busy or there is a ring-no answer, the unit can be programmed to call additional phone numbers. The phone then cycles through up to 5 pre-programmed speed dial numbers until the call is answered. Once answered, the called party will be able to hear the outside person, but at a very low level. When the outside person presses the “Push to Talk” button, his voice will then be heard at a normal level. The E-30-PT will hang up on CPC, silence, busy signal, return to dial tone, time out or Touch Tone command (
,#). If programmed to auto-answer, the E-30-PT will also answer any incoming call.
G. Programming Examples
Setting C - Silence Time Out
This feature selects the length of time that calls will remain connected without voice activity. Programmable in increments of 10 seconds up to a maximum of 90 seconds (Touch Tones 1 - 9). To disable the silence time out, program 0 in this location. Use chart at the right. * Note: The factory default is 40 seconds.
Setting D - Dial Next Number on Ring No Answer
If enabled and a ring-no-answer is detected, the E-30­PT phone will dial the next programmed speed dial
number, and continue to cycle through the emergency numbers until a call is completed. * Note: This feature is disabled in the factory default.
Touch
Tone
0 1 2 3 4 5 6 7 8 9
Silence
Time Out
Disabled
10 sec 20 sec 30 sec 40 sec* 50 sec 60 sec 70 sec 80 sec 90 sec
If enabled and a busy is detected, the E-30-PT phone will dial the next pro­grammed speed dial number, and continue to cycle through the emergency num­bers until a call is completed. * Notes: This feature is disabled in the factory
default setting. If the busy signal is interrupted with a promotional message, con­tact your central office to have it removed.
Setting E - Dial Next Number on Busy
Setting F - Pulse Dialing Rate (Pulses per Second)
The E-30-PT phone is capable of different pulse dialing speeds. * Note: The fac- tory default setting is 10pps (pulses per second).
Touch Tone
1 2
Setting F
10 pps* 20 pps
Touch Tone
1 or 0 2, 3, 4...9
Setting D
Disabled* Dials second number after 2, 3, 4...9 rings respectively
Touch Tone
1 2
Setting E
Disabled* Enabled
Speaker
Volume
Microphone
Sensitivity
DIP Switches
1 2 3
Off On
(DIP Switches shown
in factory settings)
Loading...