Viking VEWD527, CVEWD527, VEWD530, CVEWD530, VEWDO530 Installation Guide

...
Installation
Professional Built-In Electric Warming Drawers
(Indoor and Outdoor Models)
VEWD527 / CVEWD527 / VEWD530 / CVEWD530
VEWDO530 / CVEWDO530 / VEWDO536 / CVEWDO536
Warnings & Important Safety Instructions _______________________________________________3 Dimensions _________________________________________________________________________4 Specifications _______________________________________________________________________5 Cutout Dimensions (VEWD/VEWDO)___________________________________________________6 Electrical Requirements ______________________________________________________________7 General Information__________________________________________________________________8 Installation (VEWD/VEWDO) __________________________________________________________9 Final Preparation ___________________________________________________________________10 Service & Registration_______________________________________________________________11
2
IMPORTANT– Read and Follow!
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word “DANGER,” “WARNING” or “CAUTION.” These words mean:
Hazards or unsafe practices
which WILL result in severe personal
injury or death
DANGER
Hazards or unsafe practices
which COULD result in severe personal
injury or death
Hazards or unsafe practices which
COULD result in minor personal injury or
property damage.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
WARNING
CAUTION
Before beginning, please read these instructions completely and carefully.
• DO NOT remove permanently affixed labels, warnings, or plates from product. This may void the warranty.
All local and national codes and ordinances must be observed. Installation must conform with local codes, or in the absence of codes, the National Electrical Code, ANSI/NFPA70 - latest edition.
The installer must leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
In Canada: Installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes.
WARNING
FIRE AND ELECTRICAL SHOCK HAZARD
To reduce the risk of electric shock and fire, DO NOT use a flexible power-supply cord with this appliance.
WARNING
For outdoor installation, installer must install a ground fault interrupt.
WARNING
Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, hertz, wattage, amps, and phase is attached to the product. Wiring the warming drawer with more voltage than it is rated for may cause severe damage to the thermostat, element, and other components. Wiring the warming drawer with less voltage than it is rated for may cause significant decrease in performance.
WARNING
To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified people in accordance with all applicable codes and standards, including fire-rated conditions.
3
Dimensions - VEWD
4
23-1/4”
(59.1 cm)
27-3/4”
(70.5 cm)
8-31/32”
(22.8 cm)
10-1/4”
(26.0 cm)
A
Custom
VEWD527/530
VEWD527 VEWD530
Overall width A
26-1/2”
(67.3 cm)
29-1/2”
(74.9 cm)
23-1/4”
(59.1 cm)
26-3/4”
(67.9 cm)
8-31/32”
(22.8 cm)
10”
(25.4 cm)
A
Outdoor
VEWDO530/536
VEWD530 VEWD536
Overall width A
29-1/2”
(74.9 cm)
35-1/4”
(89.5 cm)
27-3/4”
(70.5 cm)
1-3/8”
26-3/4”
(67.9 cm)
(3.5 cm)
23-1/4”
(59.1 cm)
25-3/4”
(65.4 cm)
1-3/8”
(3.5 cm)
26-3/4”
(67.9 cm)
23-1/4”
(59.1 cm)
Specifications
5
Description
VEWD527 VEWD530 VEWDO530 VEWDO536
Overall width 26-1/2”
(67.3 cm)
29-1/2”
(74.9 cm)
29-1/2”
(74.9 cm)
35-1/4”
(89.5 cm)
Overall height (from bottom)
10-1/4” (26.0 cm)
Overall depth (from rear)
To end of handle
With drawer fully extended
27-3/4”(70.5 cm)
51-3/8” (130.5 cm)
26-3/4”(67.9 cm)
50-3/8” (128.0 cm)
Interior width 17-1/4”
(43.8 cm)
20-1/2”
(52.1 cm)
20-1/2”
(52.1 cm
25”
(63.5 cm)
Interior height 6” (15.2 cm) Interior depth 22-3/4” (27.8 cm)
Electrical Requirements
Hard wire direct with separate 15 amp minimum 2-wire
with ground circuit;120 VAC/50-60 Hz
Max. Amp Usage 425 watts
3.6 amps
450 watts
3.8 amps
450 watts
3.8 amps
550 watts
4.6 amps
Approx. shipping wt. 80 lb.
(36 kg)
90 lb.
(40.5 kg)
90 lb.
(40.5 kg)
110 lb.
(49.5 kg)
Rear View
VEWD/VEWDO
VEWD527 VEWD530/
VEWDO530/
Overall width C
24-7/8”
(63.2 cm)
27-7/8”
(70.8 cm)
Dimensions
C
2”
(5.1 cm)
2” (5.1 cm)
120V Electrical Opening
(When facing cabinet, opening is located on right side.)
8-31/32”
(22.8 cm)
Cutout Dimensions - VEWD/VEWDO
6
A
C
B
VEWD527 VEWD530
Cutout width (A) 25-1/4” (64.1 cm) 28-1/4” (71.8 cm)
Cutout depth (B) 23-1/2” (59.7 cm) 23-1/2” (59.7 cm)
Cutout height (C) 9-1/4” (23.5 cm) 9-1/4” (23.5 cm)
VEWDO530 VEWDO536
Cutout width (A) 28-1/4” (71.8 cm) 34” (86.4 cm) Cutout depth (B) 23-1/2” (59.7 cm) 23-1/2” (59.7 cm)
Cutout height (C) 9-1/4” (23.5 cm) 9-1/4” (23.5 cm)
C
B
A
2” min.
(5.1 cm)
Outdoor
Indoor
Note: For Outdoor Models, seal around drawer opening with silicon caulk that is provided.
Flush Mount Option:
Note: To install the warming drawer in a flush mount application, a flush mount
accessory kit is required and sold separately.
VEWD527 VEWD530
Cutout width (A) 26-15/16” (68.4 cm) 29-15/16” (76.0 cm)
Cutout depth (B) 25-3/8” (64.5 cm) 25-3/8” (64.5 cm)
Cutout height (C) 10-5/8” (27.0 cm) 10-5/8” (27.0 cm)
Electrical Requirements
WARNING
Electrical shock hazard.
To avoid the risk of electrical shock, personal injury or death;
verify electrical power is turned off at the breaker box until the range is installed and ready to operate, installation by an authorized installer only.
7
Electrical Connection
VEWD527/ VEWD530/
VEWDO530
VEWDO536
Max. amp usage
425 watts
3.6 amps
450 watts
3.8 amps
550 watts
4.6 amps
Electrical Requirements
Check your national and local codes regarding this unit. Hard wire direct with seperate 120V/15 amp minimum 2-wire wtih ground circuit. Maximum amp usage.
Note: Use copper conductors ONLY!
Grounding Instructions
This appliance must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance.
With the appliance positioned in front of the cabinet opening, connect wire leads extending from the power supply to the terminal block of the unit. Make sure the colored wires of the terminal block are connected to the corresponding colored wires extending from the power supply.
General Information
8
READ AND FOLLOW ALL WARNING AND CAUTION INFORMATION WHEN INSTALLING THIS APPLIANCE.
Moving, Handling and Unpacking
Remove and discard all packing materials, including cardboard and tape on the outside and inside of the warming drawer.
Some stainless steel parts may have a plastic protective wrap which must be peeled off. The interior should be washed thoroughly with hot, soapy water to remove film residues and any dust or debris before being used, then rinsed and wiped dry. Solutions stronger than soap and water are rarely needed.
• When installing this unit directly other units, only install with Viking Range, LLC built-in products.
• Remove warming drawer carefully from carton. Remove all loose packaging and accessories.
• It is the responsibility of the installer to comply with local codes. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/ NFPA 70 - latest edition.
This appliance is not fused. Protect
with a proper sized fuse or circuit breaker and a GFI for outdoor models.
• Line disconnect switch, circuit breaker, GFI (for outdoor models) or plug/receptacle of power cord connection should be readily accessible to the operator.
below
• Ground unit per applicable electrical codes.
• Any installation not matching the specifications discussed in these instructions will void the manufacturer’s warranty.
Installation - VEWD & VEWDO
9
1
2
1
2
Pull out warming drawer pan until fully extended.
Slide finger along right and left side until you reach the black hand latches (located at the front of the rails). Pull
up on both the right and left latches and pull out drawer
pan support.
3
Outdoor onlyOutdoor onlyOutdoor only
Electrical opening
(from rear)
4
Apply silicone caulk around the back
of the warming drawer trim.
Note: For outdoor models ONLY.
2
1
1
5
Feed supply cord up through
hole in rear of warming drawer.
Remove strain relief bracket and mounting
screws on the terminals.
1
2
6
Attach the white (neutral) and black (line) lead terminals.
Attach ground wire to the center terminal.
2”
(5.1 cm)
2”
(5.1 cm)
10
1
2
7
Push supply cord toward terminal
block to relieve strain, reattach supply cord strain relief
bracket over supply cord.
8
9
x4
Slide cavity assembly into the cabinet opening.
Secure the warming drawer using four
#8 mounting screws (four screws provided).
10
Replace drawer assembly.
Installation - VEWD & VEWDO
Final Preparation
• All stainless steel body parts should be wiped with hot, soapy water and with a liquid cleaner designed for this material. If buildup occurs, DO NOT use steel wool, abrasive cloths, cleansers, or powders! If it is necessary to scrape stainless steel to remove encrusted materials, soak with hot, wet cloths to loosen the material, then use a wool or nylon scraper. DO NOT use a metal knife, spatula, or any other material tool to scrape stainless steel! Scratches are almost impossible to remove.
11
Service & Registration
Only authorized replacement parts may be used in performing service on the appliance. All servicing should be referred to a qualified technician.
Contact Viking Range, LLC at 1-888-(845-4641), for the nearest service parts distributor in your area, visit online at vikingrange.com or write to:
VIKING RANGE, LLC
PREFERRED SERVICE
111 Front Street
Greenwood, Mississippi 38930 USA
Warming Drawer – The serial number and model number for your
appliance can be found by pulling drawer out until it stops and lifting inner lining. Rating/Serial plate is located on the left, rear side.
Record the following information indicated below. You will need it if service is ever required.
Model number ____________________________________________________________________________________
Serial number _____________________________________________________________________________________
Date of purchase __________________________________________________________________________________
Date installed ______________________________________________________________________________________
Dealer's name _____________________________________________________________________________________
Address ___________________________________________________________________________________________
These installation instructions should remain with the unit for future
reference.
Viking Range, LLC
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For more product information, call 1-888-(845-4641) or
visit our web site at vikingrange.com in the US
of brigade.ca in Canada
F20664F EN
(101515)