Viking CFGIM515, CFPIM515 Installation Guide

15”W. Undercounter/Freestanding
Installation
Machine
Ice
FGIM515 / CFGIM515
FPIM515 / CFPIM515
2
TABLE OF CONTENTS
Warnings & Important Safety Instructions______________________________________________________________________3 Dimensions (Professional)____________________________________________________________________________________5 Dimensions (Custom Panel) __________________________________________________________________________________6 Specifications ______________________________________________________________________________________________7 Cutout Dimensions _________________________________________________________________________________________7 Drain/Electrical Locations____________________________________________________________________________________8 General Information ________________________________________________________________________________________9 Air Flow ___________________________________________________________________________________________________9 Filters and Treatment _______________________________________________________________________________________9 Installation Overview_______________________________________________________________________________________10 Accessory Door Panel______________________________________________________________________________________10 Custom Panel _____________________________________________________________________________________________10 Door Panel Attachment ____________________________________________________________________________________12 Door Swing Change _______________________________________________________________________________________13 Water and Drain Installation ________________________________________________________________________________14 Electrical Connection ______________________________________________________________________________________16 Final Installation ___________________________________________________________________________________________16 Installation Checklist _______________________________________________________________________________________16 Service Information ________________________________________________________________________________________17
3
IMPORTANT – PLEASE READ AND FOLLOW
• Before beginning, please read these instructions completely and carefully.
DO NOT remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
• Please observe all local and national codes and ordinances.
• Please ensure that this product is properly grounded.
• The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
A GFI
shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture.
• Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below.
If the use of a GFI is required
, it should be:
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard)
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
It is your responsibility to be sure your ice machine is:
• located so the front is not blocked to restrict incoming or discharge air flow.
• properly leveled.
• located in a well ventilated area.
• connected to the proper kind of outlet, with the correct electric supply and grounding. A 115V, 60 Hz, 15 amp fused
electrical supply is required.
Note: Time delay fuse or circuit breaker is recommended.
• not used by anyone unable to operate it properly.
• used only for its intended purpose.
• properly maintained.
•SAVE THESE INSTRUCTIONS•
WARNING
To reduce the risk of fire, electric shock, or injury when using your unit, follow these basic precautions:
• Read all instructions before using the unit.
• Never allow children to operate, play with, or crawl inside the unit.
• Never clean unit parts with flammable fluids. The fumes can create a fire hazard or explosion.
• Always turn the power on/off switch (located behind the air grille on top right side) to the OFF position before attempting to change light bulbs, clean, or service the unit.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. THE FUMES CAN CREATE A FIRE HAZARD OR EXPLOSION.
4
PROPER DISPOSAL (OF OLD REFRIGERATION UNIT)
DANGER
RISK OF CHILD ENTRAPMENT
Before You Throw Away Your Old Refrigeration Unit:
• Take off the doors.
• Leave the shelves in place so that children may not easily climb inside.
IMPORTANT: Child entrapment and suffocation are not problems of the past. Junked or abandoned refrigeration units are still dangerous... even if they will sit for “just a few days.”
IMPORTANT:
Now that you have a new ice machine, it is extremely important that you dispose of your old appliance in a way that minimizes the possibility that children will find it. There have been many cases in years past of children crawling inside junked and abandoned refrigeration units and becoming trapped or suffocated.
Contact your municipal waste disposal authority to find out the best and safest way to dispose of your old refrigeration unit.
5
DIMENSIONS (PROFESSIONAL)
Dimensions FGIM/FPIM w/ Professional door panel
Door Swing
14-7/8”
(37.8 cm)
30-5/16”
(77.0 cm)
14-7/8”
14-7/8”
(37.8 cm)
(37.8 cm)
19-1/4”
(48.9 cm)
22-3/4”
(57.8 cm)
25-1/4”
(64.1 cm)
33-7/8”
(86.0 cm)
min.
to
34-7/8”
(88.6 cm)
max.
20-3/8”
(51.6 cm)
22-3/4”
(57.8 cm)
90.0°
14-3/4”
(37.5 cm)
3-7/8”
(9.8 cm)
Floor drain
access hole
2-1/2”
(6.4 cm)
115.0°
37-3/4”
(95.9 cm)
6
DIMENSIONS (CUSTOM PANEL)
14-7/8”
(37.8 cm)
Door Swing
Dimensions FGIM/FPIM w/ Custom door panel
30-5/16”
(77.0 cm)
14-7/8”
14-7/8”
(37.8 cm)
(37.8 cm)
19-1/4”
(48.9 cm)
22-3/4”
(57.8 cm)
33-7/8”
(86.0 cm)
min.
to
34-7/8”
(88.6 cm)
max.
20-3/8”
(51.6 cm)
22-3/4”
(57.8 cm)
90.0°
90.0°
14-3/4”
(37.5 cm)
3-7/8”
(9.8 cm)
Floor drain
access hole
115.0°
37-3/4”
(95.9 cm)