ViewZ VZ-070-TBBSV, VZ-070-TSBSV Operation Manual

VZ-070-TBBSV
VZ-070-TSBSV
Monitor Operation Manual V1.3
3G
Operating Instructions
Broadcasting Monitor User guide
15
3
5 6 7 816
Connecting to BNC Signal Device
9
SDI input signal Format
9
17
Connecting to Component Signal Device
10
17
Component input signal Format
18
10
11
Color Only NTSC Setup Max Bright
12
19 20
14
Input Output Timecode
Contents
Setting
Contents
OSD
Caution
Load System Default
Product features
Bklight Dimming
Monitor View
Misc
Source Alias UMD System Info H Flip Test Pattern
Initial Setup Basic Information Advanced
Brightness Contrast
Video
Color Temp
Composite input signal Format
HDMI input signal Format HDMI output signal Format
Function Key Marker Handheld
Connecting to Composite Signal Device
H/V Delay Still
A/V Scope
Scope Position Waveform Enable
Aspect Anamorphic Zoom Mode
Aspect Menu
Scan
Vector Enable Audio Level Meter
Peaking Color
Peaking Sensitivity
Peaking
DSLR Scale
Specification
Accessory
Limit Blink
False Color Blink
Limit Emphasis
False Color Palette
False Color L/L
False Color U/L
False Color
Peaking Blinking
Waveform Source
SDI output signal Format
Connecting to HDMI Signal Device
Color
Getting Started
Connections
MENU Features
Other Information
2
WARNING – TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THE SET TO RAIN OR MOISTURE.
"IMPORTANT SAFETY INSTRUCTIONS"
Read these instructions
Keep these instructions
Heed all warnings
Follow all instructions
Do not use this apparatus near water
Clean only with a dry cloth
Do not block any of the ventilation openings. Install in accordance with he manufacturer's instructions
Only use the attachments/accessories specified by the manufacturer.
□ Unplug this apparatus during lightning storms or when unused for long periods of time
Shall be connected to a MAINS socket outlet with a protective earthing Connection
□ The disconnect device shall remain readily operable
□ The socket-outlet shall be installed near the equipment and shall be easily accessible
Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus.
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
Do not defeat the safety purpose o f the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. When the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus
Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus
Caution
It is highly recommended to read and understand the cautions listed below thoroughly before you start using the product. And if you are unclear with any parts of the cautions or have questions, please contact us.
Caution
Caution
Manual contents are subject to change without notice
Explanation of Safety Related Symbols
Caution
Caution (cont'd)
4
Integrated Converte
r
Multi-Format Signal
ViewZ monitors are compatible with various sources includi ng
- HDMI (compatible with DVI)
- SDI signals: 3G(425A/B ), HD, SD
- CVBS(composite) and YPbPr(component)
3G-SDI: 3Gb/sec 4:4:4 HD
SDI-HDMI Loop Through
12Bit Internal Processing
2K Input Capabilit
y
Peaking / Focus Assist
DSLR Scaling
False Colors Filte
r
Under Monitor Displa
y
Menu Jog Congrol
Jog dial on the front of the m oni tor enables users to control all features
W
aveform Monito
r
Vector Scope Monito
r
Pixel to Pixel Mapping
De-Embedded Audio Level Mete
r
Aspect Format Markers
4:3, 14:9, 15:9, 16:9 etc . area, line, safety, center markers display
Gamma Encoding Select
Range from 1.0 to 3.0 users selectable. Factory default setting is 2.8
Time Code
Time code reader displays embedded LTC or VITC formats
H/V Dela
y
RJ-45 Remote Control
Product Features
Product Features
Plug in your RJ-45 connector to the back of the monitor and communicate with other ViewZ monitors (RS-485 control / Tally Light Control)
Peaking filter shows if the image is out of focus in difficult wide full range DSLR shots by highlighting areas that are out of f ocus with a cross stripe patt ern
Actively scales live video images to reduce the black areas of the screen to allow for a ful screen 16:9 image
Color filtering allows users to display different areas of the images as different colors to set portions of the scene as over or under exposed
UMD function displays ancilliary data at the bottom of the screen
Onscreen display of video levels with respect to time, used to calibrate multiple camera setups and vertical blanking level and color burst
Allows for color temperature and gamma encoding changes to be implemented quickly. Active Video Looping supports full 1080p/60 f rames on the HDMI output
Supports full SMPTE 425 signal conversion transparency from SDI to HDMI with test and measurement overlays
SMPTE 425 compliant HD display that supports frame rates of 50.60 in 1080p, 1080i, and 720p
Integrated active SDI-HDMI and HDMI-SDI converter allows the transparent conversion of HD to HDMI signal or conversion of HDMI back to HD format
View the blanking area and syncronize signals by displaying the horizontal and vertical intervals in the center of the screen
De-embedded audio selected out. Auto sensing to display three range meter of up to 16 ch
1:1 pixel mode displays the original image resolution without scaling to match a certain resolution or an aspect ratio
On-screen display of chrominance information in Cb and Cr channels. Display can be opaque or solid against the visual di splay
2k content can be displayed on ViewZ monitors without the loss of HD signal by converting and downscaling the content
Product Features
* Does not support P.O.E.
Monitor View
Exterior Information
VZ-070XXXX
X
monitor
Rear
221.5 x 126 (mm)
Stand
221.5 x 136 (mm)
Front
1. Mount
2. Tally display
3. Speaker
5. Function key F1
7. Function key F2
9. Function key F3
11. Function key F4
13. Function key F5
15. Function key F6
4. Source select
6. scanchoice
8. Main menu open
10. EXIT
12. UP
14. DOWN
15. Menu control Jog
14. Power LED
13. V mount
14. RS-485 IN
15. RS-485 OUT
16. DC 12V Power in
17. XLR Power in
18. On/Off switch
2. SDI signal in
4. SDI signal out
6. Composite out
8. Audio in R
10. PC Audio out
12. HDMI out
1. Component [ Pr ], CVBS 3 in
7. Audio in L
9. PC Audio in
11. HDMI in
3. Component [ Pb ], CVBS 2 in
5. Component [ Y ], CVBS 1 in
Monitor View
6
1
- Turn the main jog to make your choice, and click the jog to select
2
- Press the main jog on the front of the monitor for 2 seconds to enter or exit the menu
- Turn the jog to move around the menu
- Click the jog to make your selection
3
Factory default setting for programmable keys on the front of the monitor
▶▶
First Steps
Selecting Input
Menu Control
When the monitor is powered on and connected to your source,
F3 Max Bright F5 HDMI Output
F1 Blue/Mono F2
Function key
Initial Setup
- To select your source, please press SOURCE button
- Factory default is HDMI. Please skip this step if you are connected to HDMI source
- Main jog allows users to move one step at a time. If you wish to move back to previous step in the menu, press the jog for two seconds. If you want to exit the menu and restart, press exit button depending on where you are in menu tree
- Users can program 6 function buttons on the front by
MENU Function Key Function Key #
- If you click the jog without entering the main menu, brightness, contrast, color, and volume control will be available. For an example, click the jog 2 times to control contrst and 4 times to change volume
Aspect
SDI Output
H/V Delay
- All featuress in the monitor can be programmed in one of these six keys
F6
F4
VZ-070XXXX
X
Initial Setup
Loading...
+ 14 hidden pages