Viewsonic VG151-1 Service Bulletin 002

Viewsonic VG151-1 Service Bulletin 002

ViewSonic® Corporation

381 Brea Canyon Road Walnut, CA 91789 Tel: (909) 444-8727 Fax: (909) 444-8654

Service Bulletin

SB # VG151_SB_002

To : Authorized Service Providers

Issue Date: May 24, 2001

ECO # : 1321-2

Model # : VG151

Cut-in S/N : 902011210058

 

 

S/N Range :

 

 

Target Date :

 

Subject: Countermeasure to ensure proper mode synchronization for systems with H/V sync. amplitude less than 3V.

Prepared By :

Tommy Jue

Approved By :

David Lee

Purpose:

Countermeasure for start up/mode change compatibility issue when product is used with systems where the H/V sync. signal is lower than 3V.

Service Bulletin Application:

ASP Distribution:

Recall.

- USA ASP

Service Inventory, Repairs In-Process & No Problem Found (NPF).

- Canada ASP

Repairs In-Process & NPF.

- Latin America ASP

Repairs In-Process.

- 3rd Party ASP

Technician judgement for unit under service (symptomatic).

- Supplier Service ASP

 

- Limited ASP

 

- ViewSonic Internal

 

- Complete ASP Listing

Change(s)/Countermeasure(s):

Part Location

Part Description

Part Number

Repair Action

Comment

Failure

Repair

 

 

 

 

 

Code

Code

IC17

74LS86 TSSOP

E-IC-0401-2281

Replace original 74HC86A

GOA D5

 

 

 

IC with this new part.

 

*Note: Repair action(s) that consist of the countermeasures contained in this or any other service bulletin(s), shall use D5 as the repair code. All other repair action(s) outside of the service bulletin(s) shall use the appropriate repair codes contained in the Repair and Defect Codes Handbook (i.e. C7).

Please contact the Quality Assurance Department at (909) 444-8727 for further information.