Viewsonic VG151-1 Service Bulletin 002

ViewSonic® Corporation
381 Brea Canyon Road ••• Walnut, CA 91789 •••• Tel: (909) 444-8727 •••• Fax: (909) 444-8654
Service Bulletin
SB # VG151_SB_002
To : Authorized Service Providers Issue Date: May 24, 2001 ECO # : 1321-2 Model # : VG151 Cut-in S/N : 902011210058
S/N Range :
Target Date : Subject: Countermeasure to ensure proper mode synchronization for systems with H/V sync. amplitude less than 3V. Prepared By :
Tommy Jue
Approved By :
David Lee
Purpose:
Countermeasure for start up/mode change compatibility issue when product is used with systems where the H/V sync. signal is lower than 3V.
Service Bulletin Application: ASP Distribution:
Recall. - USA ASP Service Inventory, Repairs In-Process & No Problem Found (NPF). - Canada ASP Repairs In-Process & NPF. - Latin America ASP Repairs In-Process. - 3rd Party ASP Technician judgement for unit under service (symptomatic). - Supplier Service ASP
- Limited ASP
- ViewSonic Internal
- Complete ASP Listing
Change(s)/Countermeasure(s):
Part Location Part Description Part Number Repair Action Comment Failure
IC17 74LS86 TSSOP E-IC-0401-2281
*Note: Repair a ction(s) that con sist of the countermea sures contain ed in this or any other service bulletin(s), shall use D5 as the repair code. All other repair action(s) outside of the service bulletin(s) shall use the appropriate repair codes contained in the Repair and Defect Codes Handbook (i.e. C7).
Replace original 74HC86A IC with this new part.
Repair
Code
GOA D5
Code
Please contact the Quality Assurance Department at (909) 444-8727 for further information.
FORM: SERVBULL_4.19_V6 Page 1 of 1 11/7/2000