ViewSonic® Corporation
381 Brea Canyon Road • Walnut, CA 91789 • Tel: (909) 444-8727 • Fax: (909) 444-8654
Service Bulletin
SB # VG151_SB_002
To : Authorized Service Providers |
Issue Date: May 24, 2001 |
ECO # : 1321-2 |
Model # : VG151 |
Cut-in S/N : 902011210058 |
|
|
S/N Range : |
|
|
Target Date : |
|
Subject: Countermeasure to ensure proper mode synchronization for systems with H/V sync. amplitude less than 3V.
Prepared By : |
Tommy Jue |
Approved By : |
David Lee |
Purpose:
Countermeasure for start up/mode change compatibility issue when product is used with systems where the H/V sync. signal is lower than 3V.
Service Bulletin Application: |
ASP Distribution: |
Recall. |
- USA ASP |
Service Inventory, Repairs In-Process & No Problem Found (NPF). |
- Canada ASP |
Repairs In-Process & NPF. |
- Latin America ASP |
Repairs In-Process. |
- 3rd Party ASP |
Technician judgement for unit under service (symptomatic). |
- Supplier Service ASP |
|
- Limited ASP |
|
- ViewSonic Internal |
|
- Complete ASP Listing |
Change(s)/Countermeasure(s):
Part Location |
Part Description |
Part Number |
Repair Action |
Comment |
Failure |
Repair |
|
|
|
|
|
Code |
Code |
IC17 |
74LS86 TSSOP |
E-IC-0401-2281 |
Replace original 74HC86A |
GOA D5 |
|
|
|
IC with this new part. |
|
*Note: Repair action(s) that consist of the countermeasures contained in this or any other service bulletin(s), shall use D5 as the repair code. All other repair action(s) outside of the service bulletin(s) shall use the appropriate repair codes contained in the Repair and Defect Codes Handbook (i.e. C7).
Please contact the Quality Assurance Department at (909) 444-8727 for further information.
FORM: SERVBULL_4.19_V6 |
Page 1 of 1 |
11/7/2000 |
Ref.