ViewSonic® Corporation
381 Brea Canyon Road •• Walnut, CA 91789 •• Tel: (909) 444-8727 •• Fax: (909) 444-8654
Service Bulletin
SB # VG150_SB_004
To : Authorized Service Providers Issue Date: March 4, 2002 ECO # : 1923-5
Model # : VG150 Cut-in S/N : GQ14551620
S/N Range :
Target Date :
Subject: Upgraded Lien-Chang Inverter due to problem with original board using AD vendor capacitors for locations C10
and C23.
Prepared By : Tommy Jue Approved By : Richard Tanimoto
Purpose:
Upgraded Lien-Chang Inverter due to problem with original board using AD vendor capacitors for locations C10 and C23.
Inverters with 39th week date code known to have problems.
Service Bulletin Application: ASP Distribution:
Recall. - USA ASP
Service Inventory, Repairs In-Process & No Problem Found (NPF). - Canada ASP
Repairs In-Process & NPF. - Latin America ASP
Repairs In-Process. - 3rd Party ASP
Technician judgement for unit under service (symptomatic). - Supplier Service ASP
- Limited ASP
- ViewSonic Internal
- Complete ASP Listing
Change(s)/Countermeasure(s):
Part Location Part Description Part Number Repair Action Comment Failure
Replace with updated
Inverter B-SB-0221-0389
*Note: Repair action(s) that consist of the countermeasures contained in this or any other service bulletin(s), shall use D5 as the repair code. All other repair
action(s) outside of the service bulletin(s) shall use the appropriate repair codes contained in the Repair and Defect Codes Handbook (i.e. C7).
inverter with batch date
code of 40th week or later.
39th week of
inverter with known
failures.
Repair
Code
Code
VZ4 D5
Please contact the Quality Assurance Department at (909) 444-8727 for further information.
FORM: SERVBULL_4.19_V6 Page 1 of 1 11/7/2000