ViewSonic® Corporation
381 Brea Canyon Road • Walnut, CA 91789 • Tel: (909) 444-8727 • Fax: (909) 444-8654
To : Authorized Service Providers
Model # : VE710b-2M/G; VE710s-2
(VS10047)
Subject/Symptom: Service notification to add insulator tape between power board & FFC to avoid FFC
damage.
Prepared By :
Daniel Lee
Purpose: Add insulator tape between power board & FFC (flat cable) to avoid FFC (flat cable) damage due to
sharp pin of R830.
Service Bulletin Application: ASP Distribution:
Recall. - USA ASP
Service Inventory, Repairs In-Process & No Problem Found (NPF). - Canada ASP
Repairs In-Process & NPF. - Latin America ASP
Repairs In-Process. - 3rd Party ASP
Technician judgement for unit under service (symptomatic). - Supplier Service ASP
Change(s)/Countermeasure(s):
Part Location Part Description Part Number Repair Action Comment Failure
5F15
*Note: Repair action(s) that consist of the countermeasures contained in this or any other service bulletin(s), shall use D5 as the repair code. All other repair
action(s) outside of the service bulletin(s) shall use the appropriate repair codes contained in the Repair and Defect Codes Handbook (i.e. C7).
Insulator
( 24*31*0.45 T4000)
Service Bulletin
SB # VE710-2_Series_SB_013
Issue Date:
Cut-in S/N: VE710b-2: P1Q0518B0001
S/N Range:
Target Date:
Approved By :
M-00003266 Add Insulator to the circuit See photo. G0A D5
May 27, 2005 ECO # : 5408-2
VE710s-2: P1R0519B0001
Ivan Chan
- Limited ASP
- ViewSonic Internal
- Complete ASP Listing
Code
Repair
Code
Please contact the Quality Assurance Department at (886)-2-2246-3456 for further information.
4.19: Form, Service Bulletin 10/30/2002
SERV-BULL-V1 Page 1 of 1