ViewSonic® Corporation
9F, No.192, Lien Chen Rd, Chung Ho, Taipei, Taiwan• Tel: (886) 2-22463456 • Fax: (886) 222437314
Service Bulletin
To : Authorized Service Providers Issue Date: Aug. 19 2005 ECO # : 5619-1
Model # : VE710s-4M/P/G/E ;
VE710b-4M/P/G/E
(VS10047)
Subject/Symptom: Service notification to add 2nd source of Q802
Prepared By :
Purpose: Service notification to add 2nd source of Q802
Service Bulletin Application: ASP Distribution:
Recall. - USA ASP
Service Inventory, Repairs In-Process & No Problem Found (NPF). - Canada ASP
Repairs In-Process & NPF. - Latin America ASP
Repairs In-Process. - 3rd Party ASP
Technician judgment for unit under service (symptomatic). - Supplier Service ASP
Change(s)/Countermeasure(s):
Part Location Part Description Part Number Repair Action Comment Failure
XISTOR,NPN R SMD
Q802
Q802
HMBT2907A SOT23
XISTOR,NPN R SMD
Daniel Lee
HI-SINCERITY
MMBT2907ALT1G
SOT-23 ON
Cut-in S/N: VE710S PUP053600001 ; VE710B PUN053600001
S/N Range:
Target Date: VE710S 2005-09-05 ; VE710B 2005-09-06
Approved By :
E-00003850 2nd source part G0A D5
E-00003851 2nd source part G0A D5
SB # VE710-4_Serires_SB_001
Ivan Chan
- Limited ASP
- ViewSonic Internal
- Complete ASP Listing
Code
Repair
Code
*Note: Repair action(s) that consist of the countermeasures contained in this or any other service bulletin(s), shall use D5 as the repair code. All other repair
action(s) outside of the service bulletin(s) shall use the appropriate repair codes contained in the Repair and Defect Codes Handbook (i.e. C7).
Please contact the Quality Assurance Department at (886) 2-2246-3456 for further information.
4.19: Form, Service Bulletin Release Date: 06-07-05
VSC_FORM_1031, Rev. 1a Page