ENGINEERING REQUEST FORM
DATE 2006/8/25 SUPPLIER Techview REF. NO. V-115
VA2012wb-1-W
VA2012w/wb-2-W
VX2025wm-W
PRODUCT NAME MODEL NUMBER TARGET DATE CUT-IN SERIAL NO.
VS10859
VS10859
VS10859
TBD TBD
LED flicker appeared when change the power saving mode to normal picture in ORT test. In order to solve the abnormal phenomenon, power BD
modified.
REASON FOR CHANGE
Before change:
Power board P/N: AS08B532009
Description: PWR MODULE(DTA)EADP-64CF B,90~264V GP Rev: A
FROM TO
After change:
Power board P/N: AS08B532009
Description :PWR MODULE(DTA)EADP-64CF B,90~264V GP Rev: B
We will provide the cut-in date and serial number each week.
ATTACHMENTS
1 Attachment page.(1 page)
2
3
4
5
REMARKS
Page 1 of 1
Attachment Page : ( Detail description for changes )
Before change: Power board P/N: AS08B532009 ,Description:PWR MODULE(DTA)EADP-64CF B,90~264V GP Rev:
Transformer P/N:MV-CE 5048A ,circuitry qty:4,Diode ZD1:7.5A
P/B Rev:A
After change:Power board P/N: AS08B532009,Description:PWR MODULE(DTA)EADP-64CF B,90~264V GP Rev: B
Transformer P/N:MV-CE 5048B circuitry qty:5,Diode ZD1:12A
P/B Rev: B
The Transformer
change from MV-CE
5048A to MV-CE
5048B
ZD1 change from
7.5A to 12A