ENGINEERING REQUEST FORM
DATE |
|
2006/8/25 |
|
SUPPLIER |
Techview |
|
REF. NO. |
|
V-115 |
|
|
|
|
|
|
|
|
|
CUT-IN SERIAL NO. |
|
|
||||
|
PRODUCT NAME |
MODEL NUMBER |
|
TARGET DATE |
|
|
||||||
VA2012wb-1-W |
VS10859 |
|
TBD |
|
|
TBD |
|
|
||||
VA2012w/wb-2-W |
VS10859 |
|
|
|
|
|
|
|
|
|||
VX2025wm-W |
VS10859 |
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
REASON FOR CHANGE
LED flicker appeared when change the power saving mode to normal picture in ORT test. In order to solve the abnormal phenomenon, power BD modified.
FROM |
TO |
||||
Before change: |
After change: |
||||
Power board P/N: AS08B532009 |
Power board P/N: AS08B532009 |
||||
Description: PWR MODULE(DTA)EADP-64CF B,90~264V GP |
Rev: A |
|
Description :PWR MODULE(DTA)EADP-64CF B,90~264V GP |
Rev: B |
|
|
|
|
|
|
|
REMARKS
We will provide the cut-in date and serial number each week.
ATTACHMENTS
1 Attachment page.(1 page)
2
3
4
5