For operation with natural gas and liquid propane gas
Floor mounted, gas-fired condensing boiler
Heating input 19 to 199 MBH
5.6 to 58 kW
VITOCROSSAL 300
Product may not be exactly as shown
Vitocrossal 300
CU3A Series 26 to 57
Floor mounted, gas-fired condensing
boiler with modulating MatriX gas burner.
For room air dependent or independent
operation.
5673 647 - 03 07/2015
H
Product Information
Benefits
Equipped with the industry’s first intelligent combustion
management system and powerful control technology,
the new generation Vitocrossal 300 CU3A gas-fired
Floor mounted condensing boiler delivers unparalleled
performance, reliability and comfort.
The benefits at a glance:
Vitocrossal 300 CU3A 26 to 57 Technical Data
■ Best value in its class with new industry-leading
technology and the most standard features.
■ Highest Efficiency up to 98% at full modulation and up
to 95% A.F.U.E.
■ Lasting performance with industry-leading Viessmann
made SA240 316 Ti stainless steel Inox-Crossal heat
exchanger constructed to CSA B51 and ASME Section IV.
■ Low Emission Combustion with Viessmann made
stainless steel MatriX burner. Factory calibrated.
■ Fast Installation and Reduced Maintenance with Lambda
Pro, industry-first intelligent combustion management
system: Adjusts automatically to gas type and quality.
No fuel conversion kit required.
■ Powerful and User-friendly
Viessmann Vitotronic on-board multi-function outdoor
reset boiler and system control for multi-temperature
space and DHW heating.
■ Expanded Application Range with increased capacity up
to 199 MBH (58 kW). Multi-boiler installation up to
1592 MBH (464 kW) with up to 8 boilers.
■ Greater Venting Flexibility with increased vent length [up
to 198 ft. (60 m)] and multiple venting options.
- Horizontal or vertical sealed combustion coaxial
venting (field supplied).
- Horizontal or vertical single-wall venting (field
supplied).
■ Compact, Esthetic Product Design and zero clearance
to combustibles.
■ Extremely Quiet Operation; quieter than most
refrigerators.
■ True High-Altitude Operation up to 10,000 ft. (3,000 m)
with simple electronic adjustment.
■ Efficiency up to 98% through intensive condensation.
The flue gas temperature is only approximately 9-27ºF
(5-15ºC) above boiler return temperature.
2
2
5673 647 - 03
Vitocrossal 300 CU3A 26 to 57 Technical Data
Cross-Section
Vitocrossal 300 CU3A 26 to 57
Product Information
Vitocrossal 300 CU3A boiler efficiency dependent
on system heating water return temperatures and
load conditions
Product may not be exactly as shown
Legend
A Digital Vitotronic boiler control unit
B Water-cooled stainless steel combustion chamber
C Modulating MatriX gas burner – for extremely clean
combustion
D Stainless steel Inox-Crossal heat exchanger
E Highly effective thermal insulation
F Flue gas collector with condensate drain pipe
G Combustion air intake for direct vent (two-pipe)
systems
5673 647 - 03
3
3
Technical Data
Vitocrossal 300 CU3A 26 to 57 Technical Data
Technical Data
Boiler Model No. CU3A26354557
Natural Gas / Liquid Propane Gas
CSA input
CSA output / DOE heating capacity*1
Net AHRI RatingMBH
Heat exchanger surface areaft.
Min. gas supply pressure
Natural gas
Liquid propane gas
Max. gas supply pressure *3
Natural gas
Liquid propane gas
A.F.U.E.%95959595
Weightlbs
Boiler water contentUSG
Max. operating pressure
at 210ºF (99ºC)
Boiler water temperature
- Adjustable high limit (AHL) range
space heating (steady state)
DHW production
- Fixed high limit (FHL)
Boiler connections
Boiler heating supply and return
Pressure relief valve
Boiler drain
Gas valve connection
MBH
(kW)
MBH
(kW)
(kW)
(m2)
“w.c.
“w.c.
“w.c.
“w.c.
(kg)
(L)
psig
(bar)
ºF
(ºC)
ºF
(ºC)
ºF
(ºC)
NPTM
NPTF
NPTM
NPTF
2
19-94
(5.6-27.5)
17.7-87
(5.2-25.5)
76
(22)
16.7
(1.5)
4
10
14
14
269
(122)
13.5
(51)
30
(2)
68-194
(20-90)
194
(90)
210
(99)
1a”
¾”
1”
¾”
25-125
(7.3-36.6)
23.3-116
(6.8-34)
101
(30)
20.7
(1.9)
4
10
14
14
275
(125)
13.0
(49)
30
(2)
68-194
(20-90)
194
(90)
210
(99)
1a”
¾”
1”
¾”
43-160
(12.6-47)
40-149
(11.7-43.7)
129
(38)
34.1
(3.2)
4
10
14
14
352
(160)
18.8
(71)
30
(2)
68-194
(20-90)
194
(90)
210
(99)
1a”
¾”
1”
¾”
43-199
(12.6-58)
40-185
(11.7-54.2)
161
(47)
34.1
(3.2)
4
10
14
14
352
(160)
18.8
(71)
30
(2)
68-194
(20-90)
194
(90)
210
(99)
1a”
¾”
1”
¾”
*1 Output based on 140ºF (60ºC), 120ºF (49ºC) system supply/return temperature.
*2 Net AHRI rating based on piping and pick-up allowance of 1.15.
*3 If the gas supply pressure exceeds the maximum gas supply pressure value, a separate gas pressure regulator
must be installed upstream of the heating system.
Note: For high altitude installation at 10,000 ft. the input for model Vitocrossal 300 CU3A will have an altitude
de-ration of 18%.
4
4
5673 647 - 03
Vitocrossal 300 CU3A 26 to 57 Technical Data
Technical Data
Technical Data
Boiler Model No. CU3A26354557
Dimensions
Overall depth
Overall width
Overall height
(with control interface open)
Overall height
Flue gas *4
Temperature (at boiler return
temperature of 86ºF (30ºC)
- at rated full load
- at rated partial load
Temperature (at boiler return
temperature of 140ºF (60ºC)
Max. condensate flow rate *5
for NG and LPG
T
S/TR =104/86ºF (40/30ºC)USG/h
Condensate connection hose
Boiler flue gas connection *6Ø
Combustion air supply connection outer
Sound Rating (A scale)
- at maximum input
- at minimum input
Standby losses *7BTU/hr
inches
(mm)
inches
(mm)
inches
(mm)
inches
(mm)
ºF (ºC)
ºF (ºC)
ºF (ºC)
(L/h)
nozzle
Ø in.
in. (mm)3 (80)3 (80)4 (110)4 (110)
Ø in. (mm)3 (80)3 (80)3 (80)3 (80)
dB
dB
W/hr
27
684
26
660
67
1707
61.5
1562
113 (45)
90 (32)
167 (75)
0.9
3.43
27
684
26
660
67
1707
61.5
1562
113 (45)
90 (32)
167 (75)
1.2
4.62
31b
801
26
660
67
1707
61.5
1562
113 (45)
90 (32)
167 (75)
1.6
5.95
31b
1707
61.5
1562
113 (45)
90 (32)
167 (75)
7.92
¾¾ ¾ ¾
48
32
1128
330
55
33
1000
292
53
33
1120
328
801
26
660
67
2.1
58
33
995
291
*4 Measured flue gas temperature with a combustion air temperature of 68°F (20°C).
*5 Based on maximum input rate.
*6 For side wall vent installations (coaxial system):
Do not exceed max. equivalent length specified in the Installation Instructions of the Vitocrossal 300 CU3A
Venting System.
Do not attempt to common-vent Vitocrossal 300 CU3A with any other appliance.
Side wall co-axial vent installation must include Viessmann protective screen!
For details refer to the Installation Instructions for the Vitocrossal 300 CU3A Venting System.
*7 Standby losses measured from the boiler temperature sensor well based on a boiler water temperature of 158°F
(70°C) and a room temperature of 68°F (20°C).
For information regarding other Viessmann System Technology componentry, please reference documentation
of respective product.
5673 647 - 03
5
5
Dimensional Information
Models 300 CU3A 26 to 57
Vitocrossal 300 CU3A 26 to 57 Technical Data
Legend
A Overall boiler height (boiler control open)
B Overall boiler height (boiler control closed)
C Safety header connection
D Boiler supply
E Gas connection
F Boiler return
G Boiler drain
H Vent connection
I Condensate drain connection
J Combustion air connection
Model 26 to 35Model 45 and 57
a in. (mm)
b in. (mm)
c in. (mm)
d in. (mm)
Note: All height dimensions of the boiler have a tolerance of +.6 in. (+15 mm) due to the factory installed adjustable feet.
27 (684)
17 (430)
23b (595)
4
¾ (120)
a in. (mm)
b in. (mm)
c in. (mm) 28 (712)
d in. (mm)
31b (801)
21b (545)
5b (140)
6
6
5673 647 - 03
Vitocrossal 300 CU3A 26 to 57 Technical Data
Recommended Minimum Service Clearances
Note: The Vitocrossal 300 CU3A series boiler conforms
on the special venting system label.
The back or side clearance shall be increased if
piping installation is required.
Minimum Clearances
to the zero inches vent clearance to combustibles
testing requirements dictated by the boiler
Harmonized Standard ANSI Z21.13. CSA/4.9
and therefore is listed for zero clearance to
combustibles when vented with a single-wall UL/
ULC certified special venting system. The zero
inches vent clearance to combustibles for the
Vitocrossal 300 CU3A boiler supercedes the
clearance to combustibles listing that appears
Clearances
TopFrontRearLeftRightVent pipe
00 AL CL0000
AL = Alcove
CL = Closet
The Vitocrossal CU3A series boiler is approved for
closet and alcove installation with the clearances to
combustibles listed above.
Recommended minimum service clearances
For typical Vitocrossal CU3A series boiler installations,
Viessmann recommends installing the boiler with the
clearances shown in the illustration on the left.
See the Vitocrossal 300 CU3A Venting
System Installation Instructions for details.
5673 647 - 03
7
7
Waterside Flow
Pressure Drop (heating water side)
Pressure drop
Vitocrossal 300 CU3A 26 to 57 Technical Data
Flow rate
Legend
A Boiler models CU3A 26 to 35 kW
B Boiler models CU3A 45 to 57 kW
The Vitocrossal 300 is only suitable for fully pumped hot
water heating systems.
∆T = 20ºF (10 K)∆T = 30ºF (15 K)∆T = 40ºF (20 K)
Boiler models CU3A
269.9 (2.2)6.6 (1.5)4.9 (1.1)
3513.3 (3.0)8.9 (2.0)6.6 (1.5)
4517.0 (3.9)11.4 (2.6)8.5 (2.0)
5722.7 (5.2)15.0 (3.4)11.4 (2.6)
Note: This boiler does not require a flow switch.
Flow rate
USGPM (m
3
/h)
Flow rate
USGPM (m3/h)
Flow rate
USGPM (m3/h)
8
5673 647 - 03
Vitocrossal 300 CU3A 26 to 57 Technical Data
On-Board Vitotronic 200, HO1B Control
Modular structure
The control unit is integrated into the boiler. The control
unit comprises a standard unit, electronics modules and
a programming unit.
Standard unit:
■ ON/OFF switch
■ Optolink laptop interface
■ Operating and fault indicators
■ Reset button
■ Fuses
Boiler Control
Programming unit:
■ Easy operation through:
– Plain text display with graphic ability
– Large font and black & white depiction for good
contrast
– Context-sensitive help text
– Removable programming unit; can be mounted
on the wall with separate accessory
■ With digital time switch
■ Control keys for:
– Navigation
– Confirmation
– Help and additional information
– Menu
■ Setting the:
– Room temperature
– Reduced room temperature
– DHW temperature
– Heating program
– Time programs for central heating, DHW heating
and DHW recirculation
– Economy mode
– Party mode
– Holiday program
– Heating curves
– Codes
– Actuator tests
– Test mode
■ Displaying the:
– Boiler water temperature
– DHW temperature
– Operating details
– Diagnostic details
– Fault messages
5673 647 - 03
9
Boiler Control
Design and Function
Vitocrossal 300 CU3A 26 to 57 Technical Data
Functions
■ Weather-compensated control of the boiler water
and/or supply temperature
■ Control of one heating circuit without mixer and two
heating circuits with mixer (with accessory mixing
valve extension modules)
■ Demand-dependent heating circuit pump and burner
off control
■ Adjustment of a variable heating limit
■ Anti-seizing pump protection
■ Integral diagnostic system
■ Maintenance display
■ DHW temperature control with priority
■ Auxiliary function for DHW heating (short-term
heating to a higher temperature)
■ 0-10V External signal input
■ 0-10V Pump speed control output signal
Control Characteristics
PI characteristics with modulating output.
Time Switch
Digital time switch.
■ Individual and 7-day program
■ Automatic daylight savings time changeover
■ Automatic function for DHW heating and DHW
recirculation pump
■Time, day and standard switching times for space heating, DHW heating and the DHW recirculation
pump are factory-set
■Switching times are individually programmable, i.e. up to four switching periods per day
Shortest switching interval: 10 minutes
Power backup: 14 days.
Setting the Operating Programs
The heating system frost protection (see
frost protection function) applies to all heating programs.
You can select the following heating programs with the
program keys:
■ Heating and DHW
■ DHW only
■ Standby mode
External heating program changeover.
Frost protection
■The frost protection function will be started when the outside temperature drops below approx. 34°F (1°C).
With the frost protection function, the heating circuit
pump will be switched ON and the boiler water is
maintained at a lower temperature of approx. 68°F
(20°C).
The DHW tank will be heated to approx. 68°F (20°C).
■ The frost protection function will be stopped when the
outside temperature rises above approx. 37°F (3°C)
(default settings).
Summer Operation
Heating program “w”
The burner is only activated upon a call for domestic hot
water from the DHW storage tank (controlled by DHW
tank temperature sensor).
10
5673 647 - 03