Viessmann AirflowPLUS AH2A series
Hydronic forced air handler
Viessmann Airfl owPLUS
Product may not be exactly as shown
Viessmann AirflowPLUS
AH2A Series, Models 213, 354 and 385
The Viessmann AirflowPLUS works directly with other
hot water sources to provide warm comfortable heating
for any home or small commercial building.
5680 010 - 10 01/2019
Page 2
Viessmann AirflowPLUS AH2A Series
Viessmann AirflowPLUS AH2A Technical Data
The Viessmann AirflowPLUS Series is engineered to
be used with hydronic (boiler) systems, tank-less or on
demand water heaters and domestic water systems
(combo systems or aqua systems). Combo water systems
use the homes hot water heater to provide both space
heating and domestic hot water, eliminating the need for
a furnace. Outputs range from 28,000 BTUH to 115,000
BTUH.
The benefits at a glance:
■ Total Comfort: Delivers warm comfortable conditioned
air, warmer than heat pumps and many furnaces.
■ Quiet performance: Engineered and balanced with extra
insulation for quiet operation.
■ Dependable: Manufactured to precise specifications,
using high performance components.
■ Accessories: Prewired for heating, cooling, and
electronic air cleaners.
Components
■ Multi-position: Unit mounts in any direction - upflow,
downflow or horizontal discharge right or left. Use built
in filter rack for bottom return or add on external filter
rack for other return air options (included).
■ Ease of Service: All components slide out on rails for
easy maintenance and/or service.
■ Cooling: Pre-wired for A/C. Just add your favorite
evaporator coil and condensing unit from most
manufacturers.
■ Protection: Built-in safety sensors provide whole house
freeze protection, in case of thermostat failure.
■ All designs include an integral bottom return air filter
rack and air filter and a filter rack is also provided for
side return applications.
■ All models are compatible with standard or digital
thermostats.
Cabinet
All cabinets have a tough, durable powder coat finish
on satin coat 20 gauge steel.
Heating coils
All heating coils are copper and assembled using no lead
solder. All coils and internal piping conform to ASTM
B-68, B-88 and/or B-743 standards.
High density aluminum fins provide maximum heat
transfer for small coil surface.
Legend
A Standard adaptors (at the rear)
B Heating coil and pump slide out for easy service
C Integrate pump with check valve
D Fibreglass insulation with reinforced foil face and
gasket seals
E Fan and controls slide out on rails
F Integrated filter rack
2
Fan and motor
The fan is a wide body dynamically balanced for extra
quiet operation. Multi-directional sleeve bearing motors
allow mounting in any direction for maximum installation
flexibility.
Circulating pump
The internal circulating pump is matched for maximum
performance. All Viessmann AirflowPLUS air handlers come
with internally mounted pumps for ease of installation.
Check valve
A check valve is built into the circulator to protect against
backflow of water.
Cooling .2” e.s.p.
Cooling capacity(tons)1.5 - 3.02.50 - 4.03.5 - 5.0
CabinetD x W x H* in.
(mm)
22c x 18 x 32b
(578 x 457 x 825)
Supply air openingin.
(mm)
Return air openingin.
(mm)
Weightlb.
kg
Circulating pump *
TypeGrundfos 15/58RU
VoltsAC115115115
Motor horsepowerhp1/251/251/25
CapacitorMFD/VOLTS10/18010/18010/180
Motor rated amps - loadedAMPS0.740.740.74
- locked rotorAMPS4.444.444.44
Maximum working pressurePSI145145145
Min./max. fluid temperatureºF
(ºC)
Hydronic heating coil
ConstructionCopper tubing, aluminum fins, galvanized steel support frame
Rows...fins/in.3...123...123...12
Total face areasq. ft. (m
2
)1.3 (0.12)2.8 (0.26)2.8 (0.26)
Piping connections
Supplyin.
Returnin.
Pressure drop through the coilfeet of head
[@ 160°F (71°C)
supply water
temperature]
gbc
(8)
(13)
(18)
(21)
3
(681)
600
700
1,100
1,200
16 x 20
(406 x 508)
14 x 18
(356 x 457)
85
(39)
120/200
(49/93)
44,000
(13)
61,000
(18)
83,000
(24)
98,000
(29)
5
(1135)
1,200
1,400
1,300
1,600
23 x 22 x 34b
(584 x 559 x 876)
20 x 20
(508 x 508)
18 x 18
(457 x 457)
100
(45)
120/200
(49/93)
51,000
(15)
74,000
(22)
90,000
(26)
115,000
(33)
5
(1135)
1,600
1,800
1,900
2,100
28 x 22 x 34b
(711 x 559 x 876)
20 x 25
(508 x 635)
18 x 23
(457 x 584)
110
(50)
120/200
(49/93)
b FIPc FIPc FIP
b FIPc FIPc FIP
1222
* Using the adjustable levelling feet can add up to 1b in. (38 mm) to the height of the air handler.
** If motor speed decreases below the programmed stall speed, the motor will shut down and after a delay period,
the control will attempt to restart the motor. Starting current is limited to significantly less than full load current.
5680 010 - 10
3
Page 4
Dimensions
Viessmann AirflowPLUS AH2A Technical Data
IMPORTANT
The maximum ambient temperature must not exceed
104ºF (40ºC).
Top view
AH2A-213AH2A-354AH2A-385
a in.
(mm)
b in.
(mm)18(457 mm)22(559 mm)22(559 mm)
c* in.
(mm)
d* in.
(mm)
e* in.
(mm)
f in.
(mm)2(51 mm)
g in.
(mm)3(76 mm)
h in.
(mm)
* Using the adjustable levelling feet can add up to 1b in.
(38 mm) to the height of the air handler.
Legend
A Heating water supply connection
B Heating water return connection
22c
(578 mm)
32b
(826 mm)
22a
(572 mm)
23b
(597 mm)
24c
(629 mm)
23
(584 mm)28(711 mm)
34b
(876 mm)
24e
(620 mm)
25b
(650 mm)
1c
(44 mm)
3f
(92 mm)
25
(635 mm)30(762 mm)
34b
(876 mm)
24e
(620 mm)
25b
(650 mm)
1c
(44 mm)
3f
(92 mm)
Front view Side view
4
5680 010 - 10
Page 5
Viessmann AirflowPLUS AH2A Technical Data
Minimum Clearances
Horizontal Installation
Vertical Installation
Recommended minimum service clearances
For typical Viessmann AirflowPLUS installation, it
is recommended to install the air handler with the
clearances shown in the illustration.
a - 24 in. (610 mm)
b - 12 in. (305 mm)
These dimensions reflect the recommended service
clearance for the air handler only, ensure adequate clearance
is left for the installation of ducting, piping and electrical
connections. Only the b clearance may be reduced providing
there is enough clearance for ductwork, plumbing and
electrical connections, with zero clearance between the air
handler unit and ducting being acceptable.
Heating Circuit Pumps
5680 010 - 10
Pump Model Grundfos UPS15-58RU
Rated voltageVAC115
Rated currentAmp0.74
Capacitor
Power consumptionWatts87
Legend
A Speed 1 Pump curve
B Speed 2 Pump curve
C Speed 3 Pump curve
Note: All Viessmann AirflowPLUS air handlers come with
pump speed factory set to speed 3.
F
10
5
Page 6
Electrical Connections
WARNING
DISCONNECT POWER BEFORE
SERVICING BOILER.
If any of the original wires as
supplied with the appliance must be
replaced, it must be replaced with
the exact equivalent.
CAUTION
Label all wires prior to disconnection
when servicing controls. Wiring errors
can cause improper and dangerous
operation. Verify proper operation
after servicing.
Viessmann AirflowPLUS AH2A Technical Data
External Connections
Internal Connections
Power Connection
Terminal
Main power supply
120VAC, 1Ph, 60Hz, 12A
Main
Disconnect
Switch
>
Door Safety
Switch
Viessmann AirflowPLUS
Connection Board
AC Line
PMP
XFO
XFI
ECM
Power
ECM
Control
Stage 1 Cool
Stage 1 Heat
Thermostat - field supplied
(optional two stage
cooling shown)
6
24VAC
Fan Speed
Stage 2 Cool
24VAC COM
A/C Relay
Dry Contacts
Heat Fan
Alarm
5680 010 - 10
Page 7
Viessmann AirflowPLUS AH2A Technical Data
9
8
7
5
4
3
2
1
Electrical Connections (continued)
Legend
1 Diagnostic LED
2 Ambient temperature sensor
3 Return air temperature sensor
4 Supply air temperature sensor
5 Freeze protection temperature sensor
7 Supply water temperature sensor
8 A/C power
9 Pump motor
10 24VAC transformer secondary
11 24VAC transformer primary
12 ECM power
13 ECM control
Legend
AC Line
1 115VAC line
2 115VAC neutral
Pump (PMP)
1 115VAC neutral
2 115VAC line
XFO
1 24VAC
2 N/C
3 24VAC-COM (GND)
XFI
1 115VAC line
2 115VAC neutral
ECM Power
1 N/C
2 N/C
3 N/C
4 115VAC neutral
5 115VAC line
ECM Control
1 Common C1
2 W/W1
3 Common C2
4 Delay tap select
5 Cool tap select
6 Y1
7 Adjust tap select
8 Output
9 Return valve (heat pump only)
qP Humidistat (BK)
qQ Heat tap select
qW 24VAC (R)
qE 2nd stage heat (EM/W2)
qR 2nd stage cool (Y/Y2)
qT Fan (G)
qZ Output +
5680 010 - 10
7
Page 8
Viessmann AirflowPLUS AH2A Technical Data
(recycled and recyclable) paper.
Technical information subject to change without notice.Printed on environmentally friendly