Viessmann 4753, 4752, 4751 User guide [ml]

Gebrauchsanleitung
Manual
2 Signalköpfe m. Vorsignal
mit Multiplex-Technologie
2 Signal heads w. distant signal
with Multiplex technology
H0: 4751 – Ausfahrsignale 4752 – Blocksignale 4753 – Einfahrsignale
1. Wichtige Hinweise ...................................... 2
2. Einführung / Eigenschaften ........................ 3
3. Montage ..................................................... 4
4. Anschluss ................................................... 7
5. Fehlersuche & Abhilfe ................................ 7
6. Gewährleistung .......................................... 8
7. Technische Daten ...................................... 8
1. Important information ................................. 2
2. Introduction ................................................ 3
3. Mounting .................................................... 4
4. Connections ............................................... 7
5. Troubleshooting ......................................... 7
6. Warranty ..................................................... 8
7. Technical Data ............................................ 8
DE EN
1. Wichtige Hinweise
Vor Gebrauch die Sicherheitshinweise und Anlei­tung genau lesen und beachten! Anleitung aufbe­wahren. Sie ist Teil des Produktes.
1. Important information
Read and follow these safety precautions and in­structions carefully before use! Keep this manual. It is part of the product.
Sicherer Betrieb
Vorsicht: Verletzungsgefahr! Aufgrund der detaillierten Abbildung des
Originals bzw. der vorgesehenen Verwen­dung kann das Produkt Spitzen, Kanten und abbruchgefährdete Teile aufweisen. Es gehört aus diesem Grund nicht in die Hän­de von Kindern!
Vorsicht: Stromschlaggefahr! Verwendetes Versorgungsgerät (Transfor-
mator, Netzteil) regelmäßig auf Schäden an Kabeln, Stecker, Gehäuse usw. prüfen. Bei Schäden am Versorgungsgerät dieses kei­nesfalls benutzen!
Achtung: Bruchgefahr! Modell stets vorsichtig am Gehäuse an-
fassen, da die ligranen Teile des Modells
sonst abbrechen könnten. Achtung: Zerstörungsgefahr! Schließen Sie dieses Signal ausschließlich
an ein Steuermodul für Multiplex-Signale (z. B. 5229) an!
Weitere Sicherheitshinweise nden Sie im Kapi­tel Anschluss.
Das Produkt richtig verwenden
Das Produkt darf ausschließlich dieser Anlei­tung gemäß verwendet werden. Dieses Signal­modell ist bestimmt
► zum Einbau in Modelleisenbahnanlagen,
► zum Anschluss an ein Steuermodul für
Multiplex-Signale (z. B. Viessmann 5229),
► zum Betrieb in trockenen Räumen.
Jeder darüber hinausgehende Gebrauch gilt als nicht bestimmungsgemäß. Für daraus resultieren­de Schäden haftet der Hersteller nicht.
Lieferumfang
Kontrollieren Sie nach dem Auspacken den Liefer­umfang auf Vollständigkeit:
► 2 Signalköpfe 475x
mit Multiplexsteckverbindern,
► 2 Träger mit Anschlusskabeln / Buchsen ► diese Anleitung.
Safe operation
Caution: Risk of injury! Due to the de­tailed reproduction of the original and the intended use, this product can have peaks, edges and breakable parts. For that reason this product is not for children.
Warning: Electrical hazard! Never put the connecting wires into a power socket! Reg­ularly examine the transformer for damage to the cord, plug, case etc. In case of any damage, do not use the transformer!
Attention: Risk of break! Please touch the model always carefully at the case be-
cause the ligree parts of the model could
break off. Attention: risk of destruction! Connect
this signal only with digital control modul for multiplex signals (e.g., item no. 5229)
You nd other more security tips in the capital
connection
Using the product for its correct purpose
This product must only be used as specied in
this manual. This model is intended
for installation in model railroad layouts and diorama
for connection to a digital control modul for multiplex signals (e.g. 5229)
for operation in a dry area.
Using the product for any other purpose is not ap­proved and is considered incorrect. The manufac­turer cannot be held responsible for any damage resulting from the inproper use of this product.
Checking the package contents
Check the contents of the package for complete­ness after unpacking:
signal heads 475x
with multiplex plug connection
2 bearers with multiplex connection wires /
sockets
this manual
2
2. Einführung / Eigenschaften
Signale der Bauart 1969 sind nach wie vor der Streckenstandard und auf allen Bahnstrecken ab Epoche III einsetzbar. Aufgestellt seit 1969 basie­ren Sie auf den fast identischen Bauformen 1951
und 1958. Sie sind die bis heute am häugsten zu
ndenden Signaltypen im Streckennetz der ehe-
maligen Deutschen Bundesbahn. Mehr Infos zu allen Arten von Signalen sowie
deren Aufstellung und Steuerung nden Sie im
Viessmann Signalbuch (Artikelnr. 5299). Die Signalschirme sind komplett mit wartungs-
freien, energiesparenden und langlebigen LEDs
bestückt. Das Rangierfahrtsignal ist vorbildgerecht
mit weißen LEDs ausgestattet.
2. Introduction
Signals of the construction in 1969 are still dis­tance standard and could be used on all sections from epoch III. Used since 1969 they are based on the almost identical construction forms in 1951 and 1958. They are the most used signal types so far in the railway network of the former German Federal Railways.
You nd more information to all kinds of signals as
well as their installation and control in the Viess­mann signal book. (5299)
The signal background are complete with mainte­nance-free, power-saving and long life time LEDs equipped. The shunting driving signal is equipped with white LEDs like the original.
Funktionen
Filigrane Lichtsignalköpfe mit kräftiger LED-Be­leuchtung machen jede Modelleisenbahn zu einem echten Blickfang. Die Signalköpfe verfügen über Steckverbinder. Dadurch sind sie austausch­bar und können an der Signalbrücke 4750 ange­steckt oder z. B. an Brückenstellwerken oder an­deren Trägern montiert werden.
Multiplex-Technologie
Die Signalköpfe sind mit der intelligenten Multi­plextechnik ausgestattet. Dadurch führen nur ma­ximal vier Kabel mit einem Spezialstecker vom Si­gnalkopf zum Steuermodul für Multiplex-Signale. Das Steuermodul erkennt auf Knopfdruck auto-
matisch, welcher Signaltyp angeschlossen ist und konguriert sich entsprechend.
Abb. 1
Functions
The nest brass etched parts and ligree light sig­nal heads with strong LED lighting make the sig­nal bridge to a real eye-catcher. The signal heads are interchangeable by plug connector with the signal heads obtainable in pairs in each case in 4751 – in 4753.
Multiplex technology
The signal heads are equipped with the intelligent multiplex technology. Thereby only four cables maximum with a special plug of the signal head carry through to the control module for Multiplex Signals. The control module recognizes by touch of a button automatically, which signal type is con-
nected and congures itself accordingly
Fig. 1
3
Loading...
+ 5 hidden pages