Gebrauchsanleitung
Manual
2 Signalköpfe m. Vorsignal
mit Multiplex-Technologie
2 Signal heads w. distant signal
with Multiplex technology
H0:
4751 – Ausfahrsignale
4752 – Blocksignale
4753 – Einfahrsignale
1. Wichtige Hinweise ...................................... 2
2. Einführung / Eigenschaften ........................ 3
3. Montage ..................................................... 4
4. Anschluss ................................................... 7
5. Fehlersuche & Abhilfe ................................ 7
6. Gewährleistung .......................................... 8
7. Technische Daten ...................................... 8
1. Important information ................................. 2
2. Introduction ................................................ 3
3. Mounting .................................................... 4
4. Connections ............................................... 7
5. Troubleshooting ......................................... 7
6. Warranty ..................................................... 8
7. Technical Data ............................................ 8
DE EN
1. Wichtige Hinweise
Vor Gebrauch die Sicherheitshinweise und Anleitung genau lesen und beachten! Anleitung aufbewahren. Sie ist Teil des Produktes.
1. Important information
Read and follow these safety precautions and instructions carefully before use! Keep this manual.
It is part of the product.
Sicherer Betrieb
Vorsicht: Verletzungsgefahr!
Aufgrund der detaillierten Abbildung des
Originals bzw. der vorgesehenen Verwendung kann das Produkt Spitzen, Kanten
und abbruchgefährdete Teile aufweisen. Es
gehört aus diesem Grund nicht in die Hände von Kindern!
Vorsicht: Stromschlaggefahr!
Verwendetes Versorgungsgerät (Transfor-
mator, Netzteil) regelmäßig auf Schäden an
Kabeln, Stecker, Gehäuse usw. prüfen. Bei
Schäden am Versorgungsgerät dieses keinesfalls benutzen!
Achtung: Bruchgefahr!
Modell stets vorsichtig am Gehäuse an-
fassen, da die ligranen Teile des Modells
sonst abbrechen könnten.
Achtung: Zerstörungsgefahr!
Schließen Sie dieses Signal ausschließlich
an ein Steuermodul für Multiplex-Signale
(z. B. 5229) an!
Weitere Sicherheitshinweise nden Sie im Kapitel Anschluss.
Das Produkt richtig verwenden
Das Produkt darf ausschließlich dieser Anleitung gemäß verwendet werden. Dieses Signalmodell ist bestimmt
► zum Einbau in Modelleisenbahnanlagen,
► zum Anschluss an ein Steuermodul für
Multiplex-Signale (z. B. Viessmann 5229),
► zum Betrieb in trockenen Räumen.
Jeder darüber hinausgehende Gebrauch gilt als
nicht bestimmungsgemäß. Für daraus resultierende Schäden haftet der Hersteller nicht.
Lieferumfang
Kontrollieren Sie nach dem Auspacken den Lieferumfang auf Vollständigkeit:
► 2 Signalköpfe 475x
mit Multiplexsteckverbindern,
► 2 Träger mit Anschlusskabeln / Buchsen
► diese Anleitung.
Safe operation
Caution: Risk of injury! Due to the detailed reproduction of the original and the
intended use, this product can have peaks,
edges and breakable parts. For that reason
this product is not for children.
Warning: Electrical hazard! Never put the
connecting wires into a power socket! Regularly examine the transformer for damage
to the cord, plug, case etc. In case of any
damage, do not use the transformer!
Attention: Risk of break! Please touch
the model always carefully at the case be-
cause the ligree parts of the model could
break off.
Attention: risk of destruction! Connect
this signal only with digital control modul for
multiplex signals (e.g., item no. 5229)
You nd other more security tips in the capital
connection
Using the product for its correct
purpose
This product must only be used as specied in
this manual. This model is intended
• for installation in model railroad layouts
and diorama
• for connection to a digital control modul
for multiplex signals (e.g. 5229)
• for operation in a dry area.
Using the product for any other purpose is not approved and is considered incorrect. The manufacturer cannot be held responsible for any damage
resulting from the inproper use of this product.
Checking the package contents
Check the contents of the package for completeness after unpacking:
► signal heads 475x
with multiplex plug connection
► 2 bearers with multiplex connection wires /
sockets
► this manual
2
2. Einführung / Eigenschaften
Signale der Bauart 1969 sind nach wie vor der
Streckenstandard und auf allen Bahnstrecken ab
Epoche III einsetzbar. Aufgestellt seit 1969 basieren Sie auf den fast identischen Bauformen 1951
und 1958. Sie sind die bis heute am häugsten zu
ndenden Signaltypen im Streckennetz der ehe-
maligen Deutschen Bundesbahn.
Mehr Infos zu allen Arten von Signalen sowie
deren Aufstellung und Steuerung nden Sie im
Viessmann Signalbuch (Artikelnr. 5299).
Die Signalschirme sind komplett mit wartungs-
freien, energiesparenden und langlebigen LEDs
bestückt. Das Rangierfahrtsignal ist vorbildgerecht
mit weißen LEDs ausgestattet.
2. Introduction
Signals of the construction in 1969 are still distance standard and could be used on all sections
from epoch III. Used since 1969 they are based
on the almost identical construction forms in 1951
and 1958. They are the most used signal types so
far in the railway network of the former German
Federal Railways.
You nd more information to all kinds of signals as
well as their installation and control in the Viessmann signal book. (5299)
The signal background are complete with maintenance-free, power-saving and long life time LEDs
equipped. The shunting driving signal is equipped
with white LEDs like the original.
Funktionen
Filigrane Lichtsignalköpfe mit kräftiger LED-Beleuchtung machen jede Modelleisenbahn zu
einem echten Blickfang. Die Signalköpfe verfügen
über Steckverbinder. Dadurch sind sie austauschbar und können an der Signalbrücke 4750 angesteckt oder z. B. an Brückenstellwerken oder anderen Trägern montiert werden.
Multiplex-Technologie
Die Signalköpfe sind mit der intelligenten Multiplextechnik ausgestattet. Dadurch führen nur maximal vier Kabel mit einem Spezialstecker vom Signalkopf zum Steuermodul für Multiplex-Signale.
Das Steuermodul erkennt auf Knopfdruck auto-
matisch, welcher Signaltyp angeschlossen ist und
konguriert sich entsprechend.
Abb. 1
Functions
The nest brass etched parts and ligree light signal heads with strong LED lighting make the signal bridge to a real eye-catcher. The signal heads
are interchangeable by plug connector with the
signal heads obtainable in pairs in each case in
4751 – in 4753.
Multiplex technology
The signal heads are equipped with the intelligent
multiplex technology. Thereby only four cables
maximum with a special plug of the signal head
carry through to the control module for Multiplex
Signals. The control module recognizes by touch
of a button automatically, which signal type is con-
nected and congures itself accordingly
Fig. 1
3