VICOR MI-27ZMY, MI-27ZIY, MI-27ZMV, MI-27ZMW, MI-27ZMX Datasheet

...
Product Highlights
The MI-Series is designed for military applications and is based on Vicor’s 1st Generation family of zero-current/zero-voltage switching, component level DC-DC converters. Operating at frequencies in excess of 1MHz, the MI-Series offers state-of-the-art performance in terms of power density, efficiency, noise, ease of use, and reliability.
All units are manufactured in ISO 9001-registered facilities. Full epoxy encapsulation in Vicor’s industry standard package enables the MI-Series to meet MIL-STD-810 environmental requirements for humidity, fungus, salt, fog, explosive atmosphere, acceleration, vibration, and shock. (See page 32.)
Standard features such as wide output trimming/programming, current limiting, remote sense, output inhibit, and latching OVP and OTP combine to offer a high degree of protection, versatility, and reliability for military power systems.
MI-200
TM
PARAMETER MIN TYP MAX UNITS TEST CONDITIONS Input Characteristics
Input voltage range See input voltage chart No load power dissipation 1.35 2.0 Watts
Output Characteristics
Set point accuracy 0.5 1.0 % Vnom Load/line regulation 0.05 0.2 % Vnom LL to HL,10% to FL
0.2 0.5 % Vnom LL to HL,NL to 10% Output temperature drift 0.01 0.02 %/°C Output noise - pp 1.0 1.5 % Vnom Whichever is greater
100 150 mV 20MHz BW
Output voltage trimming
(1)
50 110 % Vnom Remote sense compensation 0.5 Vdc OVP set point
(2)
115 125 135 % Vnom Latching Current limit 105 125 % Inom Auto restart Short circuit current
(3)
20 130 % Inom
Control Pin Characteristics
Gate-in high threshold 6 Vdc Gate-in low threshold 0.65 Vdc Gate-in low current 6 mA Power sharing accuracy 0.95 1.05
Isolation Characteristics
Isolation (input to output) 3,000 V
rms
Isolation (output to baseplate) 500 V
rms
Isolation (input to baseplate) 1,500 V
rms
Input/output capacitance 50 75 pF
Environmental (MIL-STD-810)
Altitude - method 500.2 70,000 feet Procedure II Humidity - method 507.2 86 /240 %/hours Procedure 1,cycle 1 Acceleration - method 513.3 9 g's Procedure 2 Vibration - method 514.3 20 g's Procedure 1,category 6 Shock - method 516.3 40 g's Procedure 1
Reliability (MIL-HDBK-217F)
25°C Ground Benign: G.B. 2,478,477 hours 50°C Naval Sheltered: N.S. 584,920 hours 65°C Airborne Inhabited Cargo: A.I.C. 483,303 hours
Thermal Characteristics
Efficiency 80-90 % Baseplate to sink 0.07 °C/W With ther mal pads Thermal shutdown 90 95 105 °C Latching Baseplate operating temperature +85 °C See product grade Storage temperature +100 °C See product grade
Mechanical Specifications
Weight 6.0 (170) ounces (grams)
Converter/Booster Specifications
(At TBP= 25°C, nominal line and 75% load, unless otherwise specified)
Features
Military DC-DC Converters 50 to 100W
(1)
10V,12V,and 15V outputs, standard trim range ±10%. Consult factory for wider trim range.
(2)
No over temperature or voltage protection in booster modules.
(3)
Output voltages of 5V or less incorporate foldback current limiting; outputs of 10V and above provide constant current limiting.
Inputs:
28Vdc per MIL-STD-704D/E 155Vdc per MIL-STD-1399A 270Vdc per MIL-STD-704D/E
Single output: 2 – 48VdcUp to 23W/in
3
MIL-STD-810 environmentsUp to 90% efficiencyRemote sense
Current limitOVP and thermal shutdownPower boosters for
higher power outputs
ZVS/ZCS power architectureLow noise FM controlSize: 4.6" x 2.4" x 0.5"
(116,8 x 61,0 x 12,7mm)
}
MI-200 10/02 1 of 2
Configuration Chart
Input V oltage
Nominal Range Transient
2 = 28V 18 – 50V
(1)
60V
5 = 155V 100 – 210V 230V 6 = 270V 125 – 400V
(2)
475V
7 = 165V 100 – 310V
MI- 2 -
Semi-custom driver and booster modules available: Consult factory.
(1) 16V operation at 75% load. (2) These units rated at 75%
load from 125-150Vin:
MI-26Z-xV MI-26Y-xV MI-260-xW
28Vdc input per MIL-STD 704D/E 155Vdc input per DOD-STD-1399A 270Vdc input per MIL-STD-704D/E
Product Grade Specifications
+0.030 (0,76)
-0.000 (0)
Product ID this surface
FULL R
5
6
7
8
9
4 3
2 1
Pin #
1 2 3 4 5 6* 7* 8* 9
Function
+In
Gate In Gate Out
-In +Out
+Sense Trim
-Sense
-Out
* Do not connect on Booster modules
Aluminum Base
.01
0.040 (1,0) Dia (7) places Solder plate over copper alloy
0.080 (2,0) Dia (2) places Solder plate over copper alloy
0.30±0.015 (7,6)±(0,38)
1.80
(45,7)
4.20
0.50
0.22
(5,6) MIN
0.12
4.60
2.40
1.75
0.30
0.15 (3,8)
2.10
(53,3)
0.40
(10,2)
0.35±0.015
(8,9)±(0,38)
1.40
(35,6)
1.00
(25,4)
0.70
(17,8)
3.60
MI-200 Mechanical Drawing
0.50
(12,7)
0.15 (3,8)
MI-200
(116,8)
(91,4)
(3,0)
(7,6)Min
(12,7)
(61,0)
(44,5)
(106,7)
*
Test data available for review or download from vicorpower.com
Mechanical Drawing
Output Power/Current
5V <5V
Y = 50W 10A X = 75W 15A
W = 100W 20A
V= —o 30A
For additional power,100W and 75W booster modules available.Change MI-2xx-xx to MI-Bxx-xx.
Product Grade Operating Temp.
I = -40°C to +85°C
M = -55°C to +85°C
PARAMETER PRODUCT GRADE
I-Grade M-Grade
Storage temperature -55°C to +100°C -65°C to +100°C Operating temperature (baseplate) -40°C to +85°C -55°C to +85°C Power cycling burn-in 12 hours, 25 cycles 96 hours,200 cycles
Temperature cycled with power off
48 hours, 12-16 cycles 48 hours, 12-16 cycles
-55°C to +100°C -65°C to +100°C Test data supplied at these temperatures* -40°C,+80°C -55°C,+80°C Warranty 2 years 2 years Environmental compliance MIL-STD-810 MIL-STD-810 Derating NAVMAT P-4855-1A NAVMAT P-4855-1A
Output V oltage
Z = 2V T = 6.5V N= 18.5V Y = 3.3V R = 7.5V 3 = 24V 0 = 5V M = 10V L = 28V X = 5.2V 1 = 12V J = 36V W= 5.5V P = 13.8V K = 40V V = 5.8V 2 = 15V 4 = 48V
MI-200 10/02 2 of 2