Product Highlights
The MI-IAM is an accessory product to Vicor’s MI-Series of DC-DC converters that provides the EMI/RFI filtering and transient protection required in military applications. Designed for use with all 28V and 270V input MI-200 or MI-J00 converters, the MI-IAM can drive any number of modules with output loads to 200W.
The MI-IAM meets the conducted emissions specifications of MIL- STD-461C/D and offers complete input transient, surge, and spike protection to the most severe levels of MIL-STD-1275A and 704A. Reverse polarity protection and overvoltage lockout provide additional safeguards against potentially damaging line conditions. High power arrays can be configured using the expansion port capability of the MI-IAM.
MI-IAMTM
Military Input Attenuator Modules
Features
Inputs:
28Vdc and 270Vdc
MIL-STD-461C/D EMI compliance
MIL-STD-810 environments
MIL-STD-704A & MIL-STD1275A transients and spikes
Reverse polarity protection
Output power: Up to 200W from any combination of MI-200 or MI-J00 modules
Expansion port for additional power
Short circuit protected
Size: 2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7mm)
Specifications
(At TBP = 25°C, nominal line and 75% load, unless otherwise specified)
PARAMETER |
|
MIN |
TYP |
MAX |
UNITS |
NOTES |
Input Characteristics |
|
|
|
|
|
|
28Vdc modules |
Steady state input |
18.8 |
28 |
50 |
Vdc |
|
|
Input spike limit |
-600 |
|
600 |
Vdc |
10µS, 50Ω per MIL-STD-704A |
|
-250 |
|
250 |
Vdc |
100µS, 15mJ per MIL-STD-1275A |
|
|
|
|
||||
|
Input surge limit |
|
|
100 |
Vdc |
60mS, 0.5Ω per MIL-STD-1275A |
|
Overvoltage shutdown |
50 |
|
|
Vdc |
100mS, automatic recovery |
|
Reverse polarity protection |
|
|
|
Shunt diode: input fuse required |
|
|
Recommended fuse |
|
|
20 |
Amps |
F03A type |
270Vdc modules |
Steady state input |
125 |
270 |
400 |
Vdc |
|
|
Input spike limit |
|
|
800 |
Vdc |
10µS, 50Ω |
|
-600 |
|
600 |
Vdc |
100µS, 15mJ |
|
|
|
|
||||
|
Input surge limit |
|
|
500 |
Vdc |
100mS, 0.5Ω |
|
Overvoltage shutdown |
400 |
|
|
Vdc |
100mS, automatic recovery |
|
Reverse polarity protection |
|
|
|
Shunt diode: input fuse required |
|
|
Recommended fuse |
|
|
4 |
Amps |
F03A type |
All models |
No load power dissipation |
0.5 |
1.5 |
Watts |
|
|
|
Inrush current |
|
110 |
125 |
% Iin |
Steady state, lin 10mS |
EMC Characteristics; MIL-STD-461C/D |
|
|
|
|
|
|
Input power leads |
Conducted emissions |
CE01, CE03, CE07 |
|
|
MIL-STD-461C |
|
|
|
CE101, CE102 |
|
|
|
MIL-STD-461D |
|
Conducted susceptibility CS01, CS02, CS06 |
|
|
MIL-STD-461C |
||
|
|
CS101, CS114, CS116 |
|
MIL-STD-461D |
||
|
|
|
|
|
|
|
Output Characteristics |
|
|
|
|
|
|
Clamp voltage |
28Vdc input |
|
60 |
Vdc |
|
|
|
270Vdc input |
|
420 |
Vdc |
|
|
Output power |
|
|
250 |
Watts |
|
|
Overload protection 28Vdc input |
|
20 |
Amps |
|
Foldback threshold; auto recovery |
|
|
|
|
|
|
}with latched shutdown after 10mS |
|
|
270Vdc input |
|
4 |
Amps |
||
Isolation Characteristics |
|
|
|
|
|
|
Input to base |
|
1,500 |
|
Vrms |
|
1 min. |
Output to base |
|
1,500 |
|
Vrms |
|
1 min. |
Environmental (MIL-STD-810) |
|
|
|
|
|
|
Altitude - method 500.2 |
70,000 |
|
feet |
|
Procedure II |
|
Humidity - method 507.2 |
86/240 |
|
% /hours |
Procedure 1, cycle 1 |
||
Acceleration - method 513.3 |
9 |
|
g's |
|
Procedure |
|
Vibration - method 514.3 |
20 |
|
g's |
|
Procedure 1, category 6 |
|
Shock - method 516.3 |
40 |
|
g's |
|
Procedure 1 |
|
|
|
|
|
|
|
|
Reliability (MIL-HDBK-217F) |
|
|
|
|
|
|
25°C Ground Benign: G.B. |
3,352,133 |
|
hours |
|
|
|
50°C Naval Sheltered: N.S. |
804,512 |
|
hours |
|
|
|
65°C Airborne Inhabited Cargo: A.I.C. |
653,666 |
|
hours |
|
|
|
|
|
|
|
|
|
|
Thermal Characteristics |
|
|
|
|
|
|
Efficiency |
|
97 |
|
% |
|
|
Baseplate to sink |
|
0.14 |
|
°C/Watt |
|
|
Operating temperature, baseplate |
|
100 |
°C |
|
See product grade specifications |
|
Storage temperature |
|
125 |
°C |
|
See product grade specifications |
|
|
|
|
|
|
|
|
Mechanical Specifications |
|
|
|
|
|
|
Weight |
|
3 (85) |
ounces (grams) |
MI-IAM 04/03 1 of 2