VICOR Maxi V375A5C400BL, Maxi V375A2C160BL, Maxi V375A3V3C264BL, Maxi V375A3V3C200BL, Maxi V375A5C300BL Datasheet

...
Page 1
S
N
RT
L
C
U
S
C
US
®
Ma
x
i
Fa
m
i
l
y
Features
DC input range: 250 – 425 V
Isolated ouput
Input surge withstand: 500 V for 100 ms
DC output: 2 – 54 V
Programmable output: 10 to 110%
Regulation: ±0.25% no load to full load
Efficiency: Up to 89%
Maximum operating temp: 100°C, full load
Power density: up to 120 W per cubic inch
Height above board: 0.43 in. (10,9 mm)
Parallelable, with N+M fault tolerance
Low noise ZCS/ZVS architecture
RoHS Compliant (with F or G pin option)
Product Overview
These DC-DC converter modules use advanced power processing, control and packaging technologies to provide the performance, flexibility, reliability and cost effec­tiveness of a mature power component. High frequency ZCS/ZVS switching provides high power density with low noise and high efficiency.
375
Actual size:
4.6 x 2.2 x 0.5 in 117 x 56 x 12,7 mm
DC-
DC Conv
Absolute Maximum Ratings
Parameter Rating Unit Notes
+In to –In voltage -0.5 to +525 Vdc PC to –In voltage -0.5 to +7.0 Vdc PR to –In voltage -0.5 to +7.0 Vdc SC to -Out voltage -0.5 to +1.5 Vdc
-Sense to -Out voltage 1.0 Vdc Isolation voltage
in to out 3000 Vrms Test voltage in to base 1500 Vrms Test voltage
out to base 500 Vrms Test voltage Operating Temperature -55 to +100 °C M-Grade Storage Temperature -65 to +125 °C M-Grade
Pin soldering temperature
Mounting torque 5 (0.57) in-lbs (N-m) 6 each
500 (260) °F (°C) <5 sec; wave solder 750 (390) °F (°C) <7 sec; hand solder
er
t
er
V
I
nput
odule
Applications
Off-line systems with PFC front ends, industrial and process control, distributed power, medical, ATE, communications, defense, aerospace
For details on proper operation please refer to the
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Part Numbering
e.g. V375A12T600BL2
Output Voltage
2 = 2 V
3 V 3 = 3.3 V
5 = 5 V
8 = 8 V 12 = 12 V 15 = 15 V 24 = 24 V 28 = 28 V 32 = 32 V 36 = 36 V 48 = 48 V 54 = 54 V
Maxi Family
Page 1 of 15
Product Grade Temperatures (°C)
Grade Operating Storage
E = C = T = H = M =
-
10 to +100-20 to +125
-
20 to +100-40 to +125
-
40 to +100-40 to +125
-
40 to +100-55 to +125
-
55 to +100-65 to +125
V3 7 5 AB
Rev 9.0
4/2013
Output Power
Vout Pout 2 V 160 W
3.3 V 200 W, 264 W 5 V 300 W, 400 W 8 V 300 W, 400 W 12 V 400 W, 600 W 15 V 400 W, 600 W 24 V 400 W, 600 W 28 V 400 W, 600 W 32 V 600 W 36 V 400 W, 500 W, 600 W 48 V 400 W, 600 W 54 V 600 W
vicorpower.com
800 735.6200
Pin Style Finish Blank: Short Tin/Lead L: Long Tin/Lead S: Short ModuMate Gold N: Long ModuMate Gold F: Short RoHS Gold G: Long RoHS Gold
Baseplate Blank: Slotted 2: Threaded 3: Through-hole
Page 2
375 V Input
MODULE FAMILY ELECTRICAL CHARACTERISTICS
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter Min Typ Max Unit Notes
Operating input voltage 250 375 425 Vdc
Input surge withstand 500 Vdc <100 ms
ndervoltage turn-on 242.5 247.5 Vdc
U
Undervoltage turn-off 204.7 212.2 Vdc
Overvoltage turn-off/on 429.2 446.3 467.5 Vdc
Disabled input current 1.1 mA PC pin low
MODULE OUTPUT SPECIFICATIONS
Parameter Min Typ Max Unit Notes
Output voltage setpoint 1%Vout nom Nominal input; full load; 25°C
Line regulation ±0.02 ±0.2 % Low line to high line; full load
Temperature regulation ±0.002 ±0.005 % / °C Over operating temperature range
Power sharing accuracy ±2 ±5 % 10 to 100% of full load
Of nominal output voltage. For trimming below 90%
Programming range 10 110 %
+Out to –Out, +Sense to –Out — Absolute Maximum Ratings
2 V -0.5 to 3.1 Vdc Externally applied
3.3 V -0.5 to 4.7 Vdc Externally applied 5 V -0.5 to 7.0 Vdc Externally applied 8 V -0.5 to 10.9 Vdc Externally applied 12 V -0.5 to 16.1 Vdc Externally applied 15 V -0.5 to 20.0 Vdc Externally applied 24 V -0.5 to 31.7 Vdc Externally applied 28 V -0.5 to 36.9 Vdc Externally applied 32 V -0.5 to 41.9 Vdc Externally applied 36 V -0.5 to 47.1 Vdc Externally applied 48 V -0.5 to 62.9 Vdc Externally applied 54 V -0.5 to 70.2 Vdc Externally applied
of nominal, a minimum load of 10% of maximum rated power may be required.
Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading,
contact Vicor applications engineering at 800-927-9474.
THERMAL RESISTANCE AND CAPACITY
Parameter Min Typ Max Unit
Baseplate to sink; flat, greased surface 0.08 °C/Watt Baseplate to sink; thermal pad (P/N 20263) 0.07 °C/Watt Baseplate to ambient 4.9 °C/Watt Baseplate to ambient; 1000 LFM 1.1 °C/Watt Thermal capacity 165 Watt-sec/°C
Maxi Family
Page 2 of 15
Rev 9.0 vicorpower.com
4/2013
800 735.6200
Page 3
MODULE FAMILY ELECTRICAL CHARACTERISTICS (CONT.)
MODULE CONTROL SPECIFICATIONS
Parameter Min Typ Max Unit Notes
375 V Input
PRIMARY SIDE
PC bias voltage 5.50 5.75 6.00 Vdc PC current = 1.0 mA
current limit 1.5 2.1 3.0 mA PC voltage = 5.5 V
PC module disable 2.3 2.6 2.9 Vdc Switch must be able to sink 4 mA. See Fig. 2
C module enable delay 4 7 ms
P
PC module alarm 0.5 Vavg UV, OV, OT, module fault. See Figs. 3 and 5
PC resistance 0.9 1.0 1.1 M See Fig. 3, converter off or fault mode
PR emitter amplitude 5.7 5.9 6.1 Volts PR load >30 , <30 pF
PR emitter current 150 mA
PR receiver impedance 375 500 625 25°C
PR receiver threshold 2.4 2.5 2.6 Volts Minimum pulse width: 20 ns
PR drive capability 12 modules Without PR buffer amplifier
SECONDARY SIDE
SC bandgap voltage 1.21 1.23 1.25 Vdc Referenced to –Sense
SC resistance 990 1000 1010
SC capacitance 0.033 µF
SC module alarm 0 Vdc With open trim; referenced to –Sense. See Fig. 7
(PC = Primary Control; PR = Parallel)
During normal operation
(SC = Secondary Control)
MODULE GENERAL SPECIFICATIONS
Parameter Min Typ Max Unit Notes
Remote sense (total drop) 0.5 Vdc 0.25 V per leg (sense leads must be connected to
respective, output terminals) Isolation test voltage (in to out)* 3000 Vrms Complies with reinforced insulation requirements Isolation test voltage (in to base)* 1500 Vrms Complies with basic insulation requirements Isolation test voltage (out to base)* 500 Vrms Complies with operational insulation requirements
Isolation resistance 10 M in to out, in to baseplate, out to baseplate
Weight (E, C, T grade)
Weight (H, M grade)
Temperature limiting 100 115 °C See Figs. 3 and 5. Do not operate coverter >100C.
Agency approvals cURus, cTÜVus, CE
* Isolation test voltage, 1 minute or less.
6.5 7.3 8.1 ounces
(184.3) (207.5) (230.7) (grams)
7.4 8.2 9.0 ounces
(209.3) (232.5) (255.7) (grams)
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Note:
Specifications are subject to change without notice.
Maxi Family
Page 3 of 15
Rev 9.0 vicorpower.com
4/2013
800 735.6200
Page 4
375 V Input
ODULE SPECIFIC OPERATING SPECIFICATIONS
M
2 Vout, 160 W (e.g. V375A2C160BL)
arameter Min Typ Max Unit Notes
P
Efficiency 72 73.7 % Nominal input; full load; 25°C Ripple and noise 200 250 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 2.7 2.8 2.9 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 8.4 11 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 80 Amps Current limit 81.6 92 108 Amps Output voltage 95% of nominal Short circuit current 56 92 108 Amps Output voltage <250 mV
3.3 Vout, 264 W (e.g. V375A3V3C264BL)
Parameter Min Typ Max Unit Notes
Efficiency 79.4 81.5 % Nominal input; full load; 25°C Ripple and noise 120 150 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 4.14 4.3 4.46 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 4.9 7.8 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 80 Amps Current limit 81.6 92 104 Amps Output voltage 95% of nominal Short circuit current 56 92 104 Amps Output voltage <250 mV
3.3 Vout, 200 W (e.g. V375A3V3C200BL)
Parameter Min Typ Max Unit Notes
Efficiency 78 78.9 % Nominal input; full load; 25°C Ripple and noise 60 75 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 4.14 4.3 4.46 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 7.9 9.1 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 60.6 Amps Current limit 61.8 69.7 81.9 Amps Output voltage 95% of nominal Short circuit current 42.4 69.7 81.9 Amps Output voltage <250 mV
5 Vout, 400 W (e.g. V375A5C400BL)
Parameter Min Typ Max Unit Notes
Efficiency 80 83 % Nominal input; full load; 25°C Ripple and noise 120 150 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 6.26 6.49 6.72 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 6.6 9 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 80 Amps Current limit 81.6 92 108 Amps Output voltage 95% of nominal Short circuit current 56 97 108 Amps Output voltage <250 mV
Maxi Family
Page 4 of 15
Rev 9.0 vicorpower.com
4/2013
800 735.6200
Page 5
375 V Input
ODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
M
5 Vout, 300 W (e.g. V375A5C300BL)
Parameter Min Typ Max Unit Notes
Efficiency 82 83.3 % Nominal input; full load; 25°C Ripple and noise 80 100 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 6.03 6.25 6.47 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 8.8 10.2 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 60 Amps Current limit 61.2 69 81 Amps Output voltage 95% of nominal Short circuit current 42 69 81 Amps Output voltage <250 mV
8 Vout, 400 W (e.g. V375A8C400BL)
Parameter Min Typ Max Unit Notes
Efficiency 81.6 82.8 % Nominal input; full load; 25°C Ripple and noise 288 360 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 9.55 9.9 10.3 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 17.9 19 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 50 Amps Current limit 51 57.5 67.5 Amps Output voltage 95% of nominal Short circuit current 35 57.5 67.5 Amps Output voltage <250 mV
8 Vout, 300 W (e.g. V375A8C300BL)
Parameter Min Typ Max Unit Notes
Efficiency 82 83.1 % Nominal input; full load; 25°C Ripple and noise 220 275 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 9.36 9.7 10.1 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 9.3 10.8 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Output Current 0 37.5 Amps Current limit 38.2 43.1 50.7 Amps Output voltage 95% of nominal Short circuit current 26.2 43.1 50.7 Amps Output voltage <250 mV
12 Vout, 600 W (e.g. V375A12C600BL)
Parameter Min Typ Max Unit Notes
Efficiency 81.5 86 % Nominal input; full load; 25°C Ripple and noise 320 400 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 13.7 14.3 14.9 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 8.7 13 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 50 Amps Current limit 51 57.5 67.5 Amps Output voltage 95% of nominal Short circuit current 35 57.5 67.5 Amps Output voltage <250 mV
Maxi Family
Page 5 of 15
Rev 9.0 vicorpower.com
4/2013
800 735.6200
Page 6
375 V Input
ODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
M
12 Vout, 400 W (e.g. V375A12C400BL)
Parameter Min Typ Max Unit Notes
Efficiency 85 86.6 % Nominal input; full load; 25°C Ripple and noise 240 300 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 13.7 14.3 14.9 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 12.5 14.5 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 33.33 Amps Current limit 33.9 38.3 45 Amps Output voltage 95% of nominal Short circuit current 23.3 38.3 45 Amps Output voltage <250 mV
15 Vout, 600 W (e.g. V375A15C600BL)
Parameter Min Typ Max Unit Notes
Efficiency 85.5 87.5 % Nominal input; full load; 25°C Ripple and noise 240 300 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 17.1 17.8 18.5 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 9 12 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 40 Amps Current limit 40.8 46 52 Amps Output voltage 95% of nominal Short circuit current 28 46 52 Amps Output voltage <250 mV
15 Vout, 400 W (e.g. V375A15C400BL)
Parameter Min Typ Max Unit Notes
Efficiency 84 85.3 % Nominal input; full load; 25°C Ripple and noise 300 375 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 17.1 17.8 18.5 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 12.3 14 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 26.67 Amps Current limit 27.2 30.7 36.1 Amps Output voltage 95% of nominal Short circuit current 18.6 30.7 36.1 Amps Output voltage <250 mV
24 Vout, 600 W (e.g. V375A24C600BL)
Parameter Min Typ Max Unit Notes
Efficiency 85.5 87.5 % Nominal input; full load; 25°C Ripple and noise 80 100 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 27.1 28.1 29.1 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 9.3 10.9 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 25 Amps Current limit 25.5 28.8 33.8 Amps Output voltage 95% of nominal Short circuit current 17.5 28.8 37.5 Amps Output voltage <250 mV
Maxi Family
Page 6 of 15
Rev 9.0 vicorpower.com
4/2013
800 735.6200
Page 7
375 V Input
ODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
M
24 Vout, 400 W (e.g. V375A24C400BL)
Parameter Min Typ Max Unit Notes
Efficiency 86.5 87.7 % Nominal input; full load; 25°C Ripple and noise 120 150 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 27.1 28.1 29.1 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 13.2 15 Watts No load Load regulation ±0 ±0.2 % No load to full load; nominal input Load current 0 16.67 Amps Current limit 17 19.2 22.6 Amps Output voltage 95% of nominal Short circuit current 5 19.2 22.6 Amps Output voltage <250 mV
28 Vout, 600 W (e.g. V375A28C600BL)
Parameter Min Typ Max Unit Notes
Efficiency 86.8 87.8 % Nominal input; full load; 25°C Ripple and noise 120 150 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 31.5 32.7 33.9 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 9.5 10.2 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 21.43 Amps Current limit 21.8 24.7 28.9 Amps Output voltage 95% of nominal Short circuit current 14 24.7 28.9 Amps Output voltage <250 mV
28 Vout, 400 W (e.g. V375A28C400BL)
Parameter Min Typ Max Unit Notes
Efficiency 86.5 88 % Nominal input; full load; 25°C Ripple and noise 160 200 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 31.5 32.7 33.9 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 10.7 12 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 14.29 Amps Current limit 14.5 16.4 19.4 Amps Output voltage 95% of nominal Short circuit current 10 16.4 19.4 Amps Output voltage <250 mV
32 Vout, 600 W (e.g. V375A32C600BL)
Parameter Min Typ Max Unit Notes
Efficiency 87.1 88.1 % Nominal input; full load; 25°C Ripple and noise 168 210 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 35.9 37.3 38.7 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 11.6 12.1 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 18.75 Amps Current limit 19.1 21.6 24.5 Amps Output voltage 95% of nominal Short circuit current 13.1 21.6 24.5 Amps Output voltage <250 mV
Maxi Family
Page 7 of 15
Rev 9.0 vicorpower.com
4/2013
800 735.6200
Page 8
375 V Input
ODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
M
36 Vout, 600 W (e.g. V375A36C600BL)
Parameter Min Typ Max Unit Notes
Efficiency 86.8 88.6 % Nominal input; full load; 25°C Ripple and noise 216 270 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 40.4 41.9 43.4 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 12.6 14.7 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 16.67 Amps Current limit 17 19.2 22.6 Amps Output voltage 95% of nominal Short circuit current 11.6 19.2 22.6 Amps Output voltage <250 mV
36 Vout, 500 W (e.g. V375A36C500BL)
Parameter Min Typ Max Unit Notes
Efficiency 85.8 88 % Nominal input; full load; 25°C Ripple and noise 200 250 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 40.4 41.9 43.4 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 14.5 16 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 13.89 Amps Current limit 14.5 16 18 Amps Output voltage 95% of nominal Short circuit current 8.5 16 18 Amps Output voltage <250 mV
36 Vout, 400 W (e.g. V375A36C400BL)
Parameter Min Typ Max Unit Notes
Efficiency 87.6 88.6 % Nominal input; full load; 25°C Ripple and noise 150 188 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 40.4 41.9 43.4 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 12.4 13.2 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 11.11 Amps Current limit 11.3 12.8 15 Amps Output voltage 95% of nominal Short circuit current 7.77 12.8 15 Amps Output voltage <250 mV
48 Vout, 600 W (e.g. V375A48C600BL)
Parameter Min Typ Max Unit Notes
Efficiency 87 88.5 % Nominal input; full load; 25°C Ripple and noise 80 100 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 53.2 55.2 57.2 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 13.5 15.0 Watts No load Load regulation ±0.02 ±0.25 % No load to full load; nominal input Load current 0 12.5 Amps Current limit 12.7 14.4 16.3 Amps Output voltage 95% of nominal Short circuit current 8 14.4 16.3 Amps Output voltage <250 mV
Maxi Family
Page 8 of 15
Rev 9.0 vicorpower.com
4/2013
800 735.6200
Page 9
375 V Input
ODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
M
48 Vout, 400 W (e.g. V375A48C400BL)
Parameter Min Typ Max Unit Notes
Efficiency 87 88.3 % Nominal input; full load; 25°C Ripple and noise 200 250 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 53.7 55.7 57.7 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 14.2 16.3 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 8.33 Amps Current limit 8.49 9.58 11.3 Amps Output voltage 95% of nominal Short circuit current 5.83 9.58 11.3 Amps Output voltage <250 mV
54 Vout, 600 W (e.g. V375A54C600BL)
Parameter Min Typ Max Unit Notes
Efficiency 87.7 89.6 % Nominal input; full load; 25°C Ripple and noise 160 200 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint 60.4 62.6 64.8 Volts 25°C; recycle input voltage or PC to restart (>100 ms off) Dissipation, standby 6 12 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 11.11 Amps Current limit 11.3 12.8 15 Amps Output voltage 95% of nominal Short circuit current 7.77 12.8 15 Amps Output voltage <250 mV
Maxi Family
Page 9 of 15
Rev 9.0 vicorpower.com
4/2013
800 735.6200
Page 10
+
IN
P
C
PR
–IN
+OUT
+S
SC
–S
–OUT
C3*
4.7nF
C2*
4.7nF
For C1 – C5, keep leads and connections short.
C5*
4.7nF
C4*
4.7nF
F1*
C1*
0.2µF
BASIC MODULE OPERATION
Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors. * See Maxi, Mini, Micro Design Guide.
375 V Input
Maxi Family
Page 10
Comprehensive Online Application Information
of 15
Rev 9.0 vicorpower.com
4/2013
The Design Guide and Applications Manual includes:
• Application circuits
• Design requirements
• EMC considerations
• Current sharing in power arrays
• Thermal performance information
• Recommended soldering methods
• Accessory modules – filtering, rectification, front-ends
• Mounting options ...and more.
CLICK HERE TO VIEW
DESIGN GUIDE
Also at vicorpower.com
• PowerBench online configurators
• Over 20 Application Notes
• Online calculators – thermal, trimming, hold-up
• PDF data sheets for ALL Vicor products
800 735.6200
Page 11
+IN
PC
PR
–IN
Disable
Disable = PC <2.3 V
+IN
PC
PR
–IN
4 kΩ
"Module
+IN
PC
PR
–IN
Optocoupler
4 kΩ
Alarm
1.00V
+OUT
+S
SC
–S
–OUT
Comparator
+OUT
+S
SC
–S
– OUT
+IN
PC
PR
–IN
Input Undervoltage
2-20 ms typ.
f (VIN)
Auto
Restart
5.7 Vdc
(0-3 mA)
50 Ω
SW2
SW3
1.23 Vdc
6 K
1 K
SW1
SW1, 2, & 3
shown in
"Fault" position
Input Overvoltage (See Note 1) Overtemperature Module Faults
1
Not applicable for 300 Vdc input family
1 M
2–20 ms typ.
Fault
SC
PC
1.23 V
5.7 V
40 μs typ.
PRIMARY CONTROL - PC PIN
375 V Input
Module Enable/Disable
The module may be disabled by pulling PC below 2.3 V with respect to the –Input. This may be done with an open collec­tor transistor, relay, or optocoupler. Multiple converters may be disabled with a single transistor or relay either directly or via “OR’ing” diodes. See Figure 2.
Primary Auxiliary Supply
At 5.7 V, PC can source up to 1.5 mA. In the example shown in Figure 4, PC powers a module enabled LED.
Module Alarm
The module contains “watchdog” circuitry which monitors input voltage, operating temperature and internal operating parameters. In the event that any of these parameters are outside of their allowable operating range, the module will shut down and PC will go low. PC will periodically go high and the module will check to see if the fault (as an example, overtemperature) has cleared. If the fault has not been cleared, PC will go low again and the cycle will restart. The SC pin will go low in the event of a fault and return to its normal state after the fault has been cleared. See Figures 3 and 5.
Figure 2 Module enable/disable.
Figure 4 LED on-state indicator.
Figure 3 PC/SC module alarm logic.
Figure 5 PC/SC module alarm timing.
Figure 6 Isolated on-state indicator.
Maxi Family Rev 9.0 vicorpower.com
Page 11 of 15 4/2013
Figure 7 Secondary side on-state indicator.
800 735.6200
Page 12
375 V Input
+IN
P
C
PR
–IN
+IN
PC
PR
–IN
Module 2
Module 1
+
Parallel
Bus
0.2 µF
0.001 µF
0.2 µF
0.001 µF
Low inductance ground plane or bus
4.7 nF
4
.7 nF
4.7 nF
4.7 nF
Z
1
*
Z1*
+IN
PC
PR
–IN
+IN
PC
PR
–IN
Module 2
Module 1
T1
T2
+
0.2 µF
0.2 µF
Parallel
Bus
4.7 nF
4.7 nF
4.7 nF
4.7 nF
Z1*
Z1*
–OUT
+S
SC
Error Amplifier
+
0.033 uF
+
-S
+OUT
Load
Rd Trim Down
Ru Trim Up
1.23 V
1 kΩ
100 Ω typ.
1,000 Vout Vnom – Vout
Rd (ohms) =
1,000 (Vout –1.23) Vnom
1.23 (Vout – Vnom)
RU (ohms) =
– 1,000
SECONDARY CONTROL - SC PIN
Output Voltage Programming
The output voltage of the converter can be adjusted or programmed via fixed resistors, potentiometers or voltage DACs. See Figure 8.
PARALLEL BUS - PR PIN
arallel Operation
P
The PR pin supports paralleling for increased power with N+1
N+M) redundancy. Modules of the same input voltage, output
( voltage, and power level will current share if all PR pins are suitably interfaced.
Compatible interface architectures include the following:
AC coupled single-wire interface. All PR pins are connected to a single communication bus through 0 capacitors. This interface supports current sharing and is fault tolerant except for the communication bus. Up to three converters may be paralleled by this method. See Figure 9.
Transformer coupled interface. For paralleling four or more converters a transformer coupled interface is required. See Figure 10.
For details on parallel operation please refer to the
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
.001 µF (500 V)
Figure 8 Output voltage trim down and trim up circuit.
Trim Down
1. This converter is not a constant power device – it has a constant current limit. Hence, available output power is reduced by the same percentage that output voltage is trimmed down. Do not exceed maximum rated output current.
2. The trim down resistor must be connected between the SC and -S pins. Do not bypass the SC pin directly with a capacitor.
Trim Up
1. The converter is rated for a maximum delivered power. To ensure that maximum rated power is not exceeded, reduce maximum output current by the same percentage increase in output voltage.
2. The trim up resistor must be connected between the SC and +S pins. Do not bypass the SC pin directly with a capacitor.
3. Do not trim the converter above maximum trim range (typically +10%) or the output over voltage protection circuitry may be activated.
Maxi Family
Page 12
Trim resistor values calculated automatically:
On-line calculators for trim resistor values are available on the
Resistor values can be calculated for fixed trim up, fixed trim
asp.vicorpower.com/calculators/calculators.asp?calc=1
of 15
vicor website at:
down and for variable trim up or down.
Rev 9.0 vicorpower.com
4/2013
Figure 9 — AC coupled single-wire interface. * See Maxi, Mini, Micro Design Guide.
Figure 10 — Transformer-coupled interface.
800 735.6200
Page 13
Module 2
Module 1
Module N+1
+OUT
+S SC
S
OUT
Load
+S
–S
+OUT
+
S
SC
–S
–OUT
+
OUT
+S
SC
–S
–OUT
PARALLEL BUS OUTPUT
375 V Input
The +Out and –Out power buses should be designed to minimize and balance parasitic impedance from each module output to the load.
The +Sense pins must be tied together to form a +Sense bus. This must be Kelvin connected to +Out at a single point. The –Sense pins should be tied together to form a –Sense bus. This must be Kelvin connected to –Out at a single point.
At the discretion of the power system designer, a subset of all modules within an array may be configured as slaves by connecting SC to –S.
OR’ing diodes may be inserted in series with the +Out pins of each module to provide module output fault tolerance.
The +Sense and -Sense leads should be routed in close proximity to each other on the printed circuit board. If wires are used to connect the converters on a PCB to an external load, the Sense leads should be twisted together to reduce noise pickup.
Figure 11 N+1 module array output connections.
PIN STYLES*
Designator Description Finish Notes
(None) Short Tin/Lead Requires in-board, mounting
L Long Tin/Lead On-board mounting for 0.065" boards
S Short ModuMate Gold SurfMate or in-board socket mounting
N Long ModuMate Gold On-board socket mounting
F Short RoHS Gold Select for RoHS compliant in-board solder, socket, or SurfMate mounting
* Pin style designator follows the “B” after the output power and precedes the baseplate designator.
G Long RoHS Gold Select for RoHS compliant on-board solder or socket mounting
Ex.
V48A12T500BN2
— Long ModuMate Pins
Maxi Family
Page 13
of 15
Rev 9.0 vicorpower.com
4/2013
800 735.6200
Page 14
ALL MARKINGS THIS SURFACE
PINS STYLES SOLDER:TIN/LEAD PLATED MODUMATE: GOLD PLATED COPPER RoHS: GOLD PLATED COPPER
ALUMINUM BASEPLATE
0.195 4,95
1.400* 35,56
1.000* 25,40
0.700* 17,78
0.400* 10,16
3.844** 97,64
4.200* 106,68
1.790** 45,47
0
.06
1,5
R (4X)
0.178 4
,52
56789
12 34
±0.003
±0,08
* DENOTES TOL =
P
LATE D
THRU HOLE
DIA
PCB THICK NESS
0.062 ±0.010 1
,57 ±0,25
SHORT PIN STYLE
0.094 ±0.003 2,39 ±0,08
0.194 ±0.003 4,93 ±0,08
L
ONG PIN STYLE
0.094 ±0.003 2,39 ±0,08
0.194 ±0.003 4,93 ±0,08
INBOARD
SOLDER
MOUNT
0.45 11,5
ONBOARD
SOLDER MOUNT
(
7X)
(
2X)
0.53 13,5
**PC B WINDOW
MECHANICAL DRAWINGS
Converter Pins
No. Function Label
1 +In +
Primary
2
Control 3 Parallel PR 4 –In – 5 –Out – 6 –Sense –S
Secondary
7
Control 8 +Sense +S 9 +Out +
PC
SC
375 V Input
Figure 12 Module outline
FOR SOLDERING METHODS AND PROCEDURES PLEASE REFER TO
THE MAXI, MINI, MICRO
DESIGN GUIDE.
Unless otherwise specified, dimensions are in inches
Decimals Tol. Angles
0.XX ±0.01
0.XXX ±0.005
mm
±0,25 ±1°
±0,127
of 15
Figure 13 PCB mounting specifications
Maxi Family
Page 14
Rev 9.0 vicorpower.com
4/2013
800 735.6200
Page 15
375 V Input
icor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
V accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the “Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment and is not transferable. UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operat­ing safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the prod­ucts described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
Maxi Family
Page 15
of 15
email
Customer Service:
Technical Support: apps@vicorpower.com
custserv@vicorpower.com
Rev 9.0 vicorpower.com
4/2013
800 735.6200