Note: For alternative product grades, change the “C” in the part number to “T”.
Parameter Min Typ Max Remarks
Input Voltage 36Vdc 48Vdc 76Vdc
Safety Approvals UL 1950, CSA 22.2-950, EN 60950
Dielectric Withstand 1,500VRMS Input/Output to Base
EMI/ RFI Bellcore GR-001089-Core Issue 2 When used with Vicor 2nd
EN 55022 Level B Generation 48Vin DC-DC converters
FCC Part 15 Level B
Output Current
FM4808C12 8A Delivered current to any
FM4812C12 12A combination of Vicor’s 2nd Generation
48Vin DC-DC Converter
Reverse Polarity Protection
No damage to unit, external
fusing required
Weight 2.1 Ounces (60 Grams)
Parameter C-Grade T-Grade
Storage Temp. –40°C to +125°C –40°C to +125°C
Operating Temp. (Baseplate) –20°C to +100°C –40°C to +100°C
Warranty 2 years 2 years
Product Grade Specifications
FM48-FiltMod Specifications
(typical at TBP= 25°C, nominal line, 75% load, unless otherwise specified)
Typical transient, surge protection and filtering solution
IAM2
2nd Generation
48Vdc Input
DC-DC Converters
–IN
PR
PC
+IN
–OUT
–S
SC
+S
+OUT
FM48
–IN
+IN
IAM48
4 3 2 1
7 6 5
4 3 2 1
7 6 5
Note: The IAM48 is shown in the on state.
To disable, open the connection to pin 3.
45
Shown actual size:
2.28 x 1.45 x 0.5 in
57,9 x 36,8 x 12,7 mm
Data Sheet
FM48
TM
FiltMod
Input Filter Module
Features
• Low Profile Mounting Option
• EMI Filtering
• 8 and 12 Amp versions
•
CE Marked
• Micro Sized Module
Products Highlights
The FM48 input filter module enables
designers to meet the conducted
emission limits of EN55022 level B
and FCC level B when used with
Vicor’s 48 Volt 2nd Generation of
DC-DC converters. FiltMods accept
an input voltage of 36 to 76 Vdc with
a transient withstand capability of
100Vdc for 100 msec. The FiltMods are
packaged in an industry standard
“quarter-brick” module measuring
2.28" x 1.45" x 0.5" and are available
in either 8 or 12 Ampere capacity.
Both versions may be on-board or
in-board mounted for height critical
applications. The FiltMods can be
teamed with Vicor’s IAM48 for
transient and surge protection.
Compatible Products
• IAM48
• 2nd Generation 48V input
DC-DC converters
Part Numbers
FM4808C11: 8 Amp – Short Pins
FM4808C12: 8 Amp – Long Pins
FM4812C11: 12 Amp – Short Pins
FM4812C12: 12 Amp – Long Pins
Set your site on VICOR at www.vicr.com
Conducted Noise
FM4812C12 and Model V48A12C500A
DC-DC Converter.
FM4812C12 and Model V48B24C250A
DC-DC Converter.
Mechanical Drawings (FM48-FiltMod)
567
4321
(REF)
0.080
2,03
DIA. (7X)
0.21
5,2
0.27
6,9
(2X)
2.000
50,80
1.04
26,4
1.45
36,8
.275
6,99
0.800
20,32
0.525
13,34
0.400
10,16
0.350 ±.015
8,89 ±0,38
0.235 ±.015
5,97 ±0,38
FULL R (6X)
0.10
2,5
CHAMFER
(REF.)
(6X)
0.65
16,5
0.49
12,4
0.09
2,3
1.27
32,3
1.30
33,0
2.28
57,9
1.45
36,8
0.13
3,3
0.06
1,5
R (3X)
0.01
X 45˚
Use a
4-40 Screw (6x)
Torque to:
5 in-lbs
0.57 N-m
0.54
13,7
0.43
10,9
0.62
15,7
7X)
(7X)
12,7 ±0,5
0.50 ±0.02
Slotted (Style 1)
or
Threaded (Style 2)
4-40 UNC-2B (6X)
or
Thru Hole (Style 3)
#30 Drill Thru (6X)
(0.1285)
* Style 1 baseplate only
** Style 2 & 3 baseplates
*** Reserved for Vicor accessories
style 2 & 3
baseplates only
(4X)***
0.12*
3,1
0.20**
5,08
ALUMINUM
BASEPLATE
Pin Style 2
(Long)
Pin Style 1
(Short )
23
617
4
5
PLATED
THRU HOLE
DIA
±0,08
*DENOTES TOL = ±0.003
0.133
3,38
1.734**
44,04
.400*
10,16
1.140**
28,96
0.170*
4,32
0.800*
20,32
0.525*
13,34
0.275*
6,99
2.000*
50,80
0.06
1,5
R (4X)
INBOARD
SOLDER
MOUNT
PIN STYLE 1
0.094 ±0.003
2,39 ±0,08
0.43
10,9
(7X)
**PCB WINDOW
PCB THICKNESS
0.062 ±0.010
1,57 ±0,25
0.53
13,3
ONBOARD
SOLDER
MOUNT
PIN STYLE 2
0.094 ±0.003
2,39 ±0,08
PIN OUTS
No. Function Label
1 +Vin +V
2N/C
3N/C
4 –Vin –V
5 –Vout –V
6 Ground GND
7 +Vout +V
Unless otherwise specified,
dimensions are in inches
mm
Decimals Tol. Angles
0.XX ±0.01
±0.25 ±1°
0.XXX ±0.005
±0.127
PCB Mounting Specifications
PINS: TIN/LEAD
HOT SOLDER DIPPED
ALUMINUM
BASEPLATE
ALL MARKINGS
THIS SURFACE
PINS: TIN/LEAD
HOT SOLDER DIP
Vicor Corporation 25 Frontage Road, Andover, MA 01810 • Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715 11-00 • Rev2 • P/N 23295
Set your site on VICOR at www.vicr.com