Vicor FlatPAC Specifications

Page 1
50 to 600 Watts Autoranging, AC-DC Switchers
FlatPAC™
FlatPAC™ Rev 1.6 vicorpower.com
Page 1 of 6 01/2015
800 927.9474
0
1 1 E U U U
Configuration Chart
RoHS compliant (VE versions)
Microcontroller architecture
Inputs: 115/230 Vac autoranging
Meets FCC Part 15, EN55022,
Class B conducted emissions
80 – 90% efficiency
Any output: 1 to 95 Vdc
Module enable/disable
(except LU series)
UL, TÜV, CE marked
Remote sense and current limit
BUS OK and AC OK
(except LU series)
40 ms ride-through time
OVP and thermal shutdown
1 output; up to 200 W
1 or 2 outputs; up to 400 W
1, 2, or 3 outputs; up to 600 W
Product Highlights
If you’re looking for the convenience of a complete, low profile, agency­approved switching power supply, look no further. The FlatPAC combines Vicor’s workhorse VI-200 family of DC-DC converters with a modular package and front-end subassembly to provide from 50 to 600 W of output power from one to three outputs.
A flat plate heat sink for use in conduction cooled applications may be specified as an alternate to the standard finned version by adding “CC” to the end of the model number.
Vicor’s FlatPAC is also available with a current controlled output using BatMod converter modules of 12, 24, or 48 Vdc outputs. This option is specified by appending “BM” or “BC” (for conduction cooled versions) to the end of the FlatPAC model number.
Mixing VI-200 and BatMods in a single FlatPAC is not permissible.
The FlatPAC’s contemporary design allows us to configure your order quickly and provide rapid turnaround on standard models. It is truly a complete power solution, enabling you to spend more time designing your system and less time worrying about how to power it.
Substitute VE– for VI– for RoHS compliant versions
Configuration Total # of
Power Converters Dimensions
Single Output
VI-LU - 50 – 200 W 1
9.25" x 2.5" x 1.37" (234,8 x 124,5 x 34,8 mm)
VI-MU - 200 – 400 W 2
9.25" x 4.9" x 1.37" (234,8 x 124,5 x 34,8 mm)
VI-NU - 300 – 600 W 3
9.25" x 7.3" x 1.37" (234,8 x 185,4 x 34,8 mm)
Dual Output
VI-PU - 100 – 400 W 2
9.25" x 4.9" x 1.37" (234,8 x 124,5 x 34,8 mm)
VI-QU - 150 – 600 W 3
9.25" x 7.3" x 1.37" (234,8 x 185,4 x 34,8 mm)
Triple Output
VI-RU - 150 – 600 W 3
9.25" x 7.3" 1.37" (234,8 x 185,4 x 34,8 mm)
Typical Model: VI-RU - -
Input Output Input Characteristics 115/230 Vac 1: 5 Vdc at 200 W 90–132/180–264 Vac
2: 12 Vdc at 200 W U = Autoranging 3: 12 Vdc at 200 W
Z = 2 V Y = 3.3 V 0 = 5 V X = 5.2 V
W = 5.5 V V = 5.8 V T = 6.5 V R = 7.5 V
M = 10 V 1 = 12 V P = 13.8 V 2 = 15 V
N = 18.5 V 3 = 24 V L = 28 V J = 36 V
K = 40 V 4 = 48 V H = 52 V F = 72 V
D = 85 V B = 95 V
Output Voltage
Grade Operating Storage
E = 0 to +85 –20 to +100 C = 0 to +85 –20 to +100 I = – 30 to +85 –55 to +100
Temperatures apply to product case.
Product Grade Temps. °C
V
OUT
5 V V
OUT
< 5 V
Y = 50 W Y = 10 A X = 75 W X = 15 A W = 100 W W = 20 A V = 150 W V = 30 A U = 200 W U = 40 A
Output Power/Current
VOUT 5 V VOUT < 5 V
W= 100 W W = 20 A V = 150 W V = 30 A U = 200 W U = 40 A S = 300 W S = 60 A Q = 400 W Q = 80 A
Output Power/Current
VOUT 5 V VOUT < 5 V
S = 300 W S = 60 A P = 450 W P = 90 A M = 600 W M = 120 A
Output Power/Current
BC = BatMod/Conduction Cooled BM = BatMod CC = Conduction Cooled
Options
Page 2
FlatPAC™
FlatPAC™ Rev 1.6 vicorpower.com
Page 2 of 6 01/2015
800 927.9474
INPUT SPECIFICATIONS
Parameter Min Typ Max Unit Notes
AC line input
Autoranging 90 – 132/180 – 264 Vac
Line frequency
47 – 63 Hz (C-Grade and E-Grade)
47 – 440 Hz (I-Grade)
Inrush current: 115 Vac operation:
1 converter 16 A @ peak line 2 converters 23 A @ peak line 3 converters 39 A @ peak line
Inrush current: 230 Vac operation
1 converter 32 A @ peak line 2 converters 47 A @ peak line 3 converters 78 A @ peak line
Ride-through time (full load)
90/180 Vac low line 5 ms minimum 115/230 Vac nominal line 40 ms minimum
AC fail warning time 5 ms minimum (low line, full load)
AC and BUS OK (2 and 3 converter models only)
Off state – Vce 70 V On state – Vcesat 0.4 V @ 1 mA (1.5 mA max.)
Module disable (2 and 3 converter models only, optically isolated LED input)
Continuous forward current 1 – 30 mA Forward voltage 1.65 V @ 30 mA
Dielectric withstand
Primary to chassis GND 2,121 Vdc Primary to secondary 4,242 Vdc Secondary to chassis GND 707 Vdc
SPECIFICATIONS
(typical at 25°C, nominal line and 75% load, unless otherwise specified)
E-Grade C-, I-Grade
Parameter Min Typ Max Min Typ Max Unit Notes
Set point accuracy 1% 2% 0.5% 1% VNOM
Load/line regulation 0.5% 0.05% 0.2% VNOM LL to HL, 10% to Full Load
1% 0.2% 0.5% VNOM LL to HL, No Load to full load
Output temperature drift 0.02 0.01 0.02 %/°C Over rated temperature
Long term drift 0.02 0.02 %/1 k hours
Output ripple
2 V 150 mV 60 mV 100 mV p-p 20 MHz bandwidth 5 V 5% 2% 3% p-p 20 MHz bandwidth 10 – 48 V 3% 0.75% 1.5% p-p 20 MHz bandwidth
Output voltage trimming
1
50% 110% 50% 110%
Total remote sense
compensation 0.5 0.5 Volts 0.25 V max. neg. leg
OVP set point 125% 115% 125% 135% VNOM Recycle power
Current limit 105% 135% 105% 125% INOM Automatic restart
Short circuit current
2
20% 140% 20% 130% INOM
OUTPUT SPECIFICATIONS
Page 3
FlatPAC™ Rev 1.6 vicorpower.com
Page 3 of 6 01/2015
800 927.9474
FlatPAC™
SPECIFICATIONS (CONT.)
E-Grade C-, I- Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Efficiency 78 – 88% 80 – 90% @5 V and higher
Shut down temp. — case 90 95 105 90 95 105 °C
Cool and recycle power to restart
Operating temp. — case 85 85 °C See Thermal Curves
THERMAL CHARACTERISTICS
E-Grade C-, I- Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Weight
3
22.4 22.4 Ounces
(652) (652) (Grams)
MECHANICAL SPECIFICATIONS
AGENCY APPROVALS
Safety Standards Markings Notes
UL1604, UL60950-1 cURus
UL / CSA / EN / IEC 60950-1 cTÜVus,
CE Mark Low Voltage Directive
1
10 V, 12 V and 15 V outputs, trim range ± 10%. Consult factory for wider trim range.
2
Output voltages of 5 V or less incorporate foldback current limiting, outputs greater than 5 V incorporate straight line current limiting.
3
For MU, PU series, multiply value by 2; for NU, QU, RU series, multiply value by 3.
EMI / EMC Characteristics (Performed on selected samples representative of the U Series FlatPac product family.)
Parameter Notes
Conducted emissions, LISN EN 55022 and FCC R&R, Part 15, Subpart B, Class B
Radiated emissions, 10 meters EN 55022; 1998 and FCC R&R, Part 15, Subpart B, Class A
Electrostatic discharge IEC 61000-4-2: 1995, Level 4; ±8 kV Contact, ± 15 kV Air Discharge
RF radiated immunity, E-field IEC 61000-4-3: 1997; 80 MHz to 1.0 GHz, 3 V/M, CW
Electrical fast transients/burst EN 61000-4-4: 1995, Level 3; ±2 kV,
Surge immunity EN 61000-4-5: 1996 Class 3; ±2 kV Line to Ground, ±1 kV Line to Line
RF conducted immunity IEC 61000-4-6: 1996, class 3, 10 Vrms, 150 kHz to 80 MHz
Power frequency magnetic
IEC 61000-4-8: 1994, 30 to 300 A/M, 50Hz
field immunity Voltage dips and interrupts IEC 61000-4-11: 1994
Page 4
FlatPAC™
FlatPAC™ Rev 1.6 vicorpower.com
Page 4 of 6 01/2015
800 927.9474
Time Interval Min Typ Max Units Notes
T0-T1 0 0.1 1.0 ms T2-T3 0 40 ms Ride-through time T2-T4 5 ms Hold-up time T3-T4 5 ms AC fail warning time
Resistor Values for Trimming Standard Output Voltages
Nom. Output Voltage 5 V 12 V 15 V 24 V 28 V 48 V Trim Range
R1(kΩ) 0.953 15.8 22.1 41.2 48.7 90.9
+10%, -10%
R2(kΩ)909090909090
R2
+S
Trim
10K
R1
+ Vout
Vout RTN
+O
–O
–S
AC Mains Connections
Power Up and Power Down Sequencing
Output Trimming
THERMAL CURVES
APPLICATION CIRCUITS
5 V Output
0
25
50
75
100
125
150
175
200
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Output Power (Watts)
0
50
100
150
200
250
300
350
400
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Output Power (Watts)
0
75
150
225
300
375
450
525
600
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Output Power (Watts)
FREE AIR 50 LFM 100 LFM 250 LFM 500 LFM
750 LFM 1000 LFM
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
LU Series MU, PU Series NU, QU, RU Series
Ambient Temperature (Deg. C)
Output Power (Watts)
Output Power (Watts)
Output Power (Watts)
10 to 48 V Output
0
25
50
75
100
125
150
175
200
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Output Power (Watts)
0
50
100
150
200
250
300
350
400
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Output Power (Watts)
0
75
150
225
300
375
450
525
600
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Output Power (Watts)
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
LU Series MU, PU Series NU, QU, RU Series
Ambient Temperature (Deg. C)
Output Power (Watts)
Output Power (Watts)
Output Power (Watts)
Ambient Temperature (°C)
Ambient Temperature (°C)
Ambient Temperature (°C)
Ambient Temperature (°C)
AC
Line
AC-OK
V
> 90 (180)Vac
LINE
Interrupted
AC Line
Ambient Temperature (°C)
Ambient Temperature (°C)
BUS-OK
MOD-DIS –
AC Mains
Earth Ground
MOD-DIS + AC-OK – AC-OK + BUS-OK – BUS-OK +
L1 L2/N GND
Internal Supervisory Circuits (Optocouplers)
1-Up
2-Up
and
3-Up
T1 T2
T0
Conditions: Full Load 90 (180)Vac, AC Line
T4
T3
Page 5
FlatPAC™ Rev 1.6 vicorpower.com
Page 5 of 6 01/2015
800 927.9474
FlatPAC™
MOUNTING HOLE ø 0.15 ±0.01 THRU 5 PLACES
10 11 12 13 14 15 16
7 8 9
4.562 ±0.010
(115,87 ±0,25)
2.281 ±0.010 (57,94 ±0,25)
0.199 ±0.010 (5,05 ±0,25)
0.18
(4,57)
6.00
(152,4)
4.960 ±0.030
(125,98 ±0,76)
3.83
(97,16)
1.17
(29,72)
+
Inputs
1 MOD DIS– 2 MOD DIS+ 3 AC OK– 4 AC OK+ 5 BUS OK– 6 BUS OK+ 7 AC IN L1 8 AC IN L2/N 9 CHASSIS GND
Outputs
10 +OUT (#10-32 Stud) 11 +OUT 12 +SENSE (V
TRIM
*)
13 TRIM (I
TRIM
*)
14 –SENSE (I
MON
*) 15 –OUT 16 –OUT (#10-32 Stud)
*On FlatPACs with BatMODs only.
Input connector, Amp P/N 644488-6; mating connector, MTA-100 IDC Series
Terminals for #16-12 AWG wire
Output connector, Amp P/N 644486-5; mating connector, MTA-100 IDC Series
LU SERIES
MU SERIES PU SERIES
NU SERIES QU SERIES RU SERIES
MECHANICAL DRAWINGS
STANDARD MODELS
CONDUCTION COOLED MODELS “–CC”
10 11 12 13 14 15 16
10 11 12 13 14 15 16
OUTPUT 1 OUTPUT 2
+
2.540 ±0.030 (64,52 ±0,76)
1.27
(32,26)
1.375 ±0.020 (34,91 ±0,51)
0.50
(12,57)
9.245 ±0.030
(234,82 ±0,76)
0.18
(4,57)
7
8
9
6.00
(152,4)
2.156 ±0.010 (54,76 ±0,25)
0.192 ±0.010 (4,88 ±0,25)
1.11
( 28,19)
MOUNTING HOLE ø 0.15 ±0.01 THRU 4 PLACES
OUTPUT 1
10 11 12 13 14 15 16
7.380 ±0.030
(187,45 ±0,76)
5.48
(139,19)
1.93
(49,02)
7.000 ±0.010 (177,8 ±0,25)
4.710 ±0.010
(119,63 ±0,25)
2.290 ±0.010 (58,17 ±0,25)
0.190 ±0.010 (4,83 ±0,25)
1 2
3
4 5 6
7
8
9
0.18
(4,57)
6.00
(152,4)
MOUNTING HOLE ø 0.15 ±0.01 THRU 6 PLACES
+
10
16
10
16
10 11 12 13 14 15
OUTPUT 1
16
OUTPUT 2
OUTPUT 1
+
10 11 12 13 14 15 16
10
16
+
10 11 12 13 14 15 16
OUTPUT 3
OUTPUT 2
OUTPUT 1
10 11 12 13 14 15 16
10 11 12 13 14 15 16
10 11 12 13 14 15 16
Page 6
FlatPAC™
FlatPAC™ Rev 1.6 vicorpower.com
Page 6 of 6 01/2015
800 927.9474
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality con­trols are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the “Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment and is not transferable. UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DIS­CLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FIT­NESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MAT­TER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor prod­ucts and components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the prod­ucts described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service:
custserv@vicorpower.com
Technical Support: apps@vicorpower.com
Loading...