![](/html/21/21cc/21cca58ea8c66ac11b769989b7e52aff4d7f011f64f00b8c1124af02add552dc/bg1.png)
Technical Data Sheet
Vibra-Tite® 930
Epoxy
November 2012
Product Description
Vibra-Tite 930 is a single-part heat cured epoxy
adhesive with excellent adhesion to metal oily
surfaces as well as composite material. This epoxy
can be used to enhance joint stiffness and joint
durability. The high bond strength of this adhesive
allows it to replace mechanical fasteners, soldering,
brazing, or welding. This material requires heat in
the range of 120oC to 200oC. Vibra-Tite 930 is nonsagging allowing this product to be used in large gaps
and on vertical surfaces.
Features and Benefits
Excellent Adhesive Strength
Enhanced Joint Durability
Bonds Through Oily Substrates
Easy to Use 1K System
High Shear and Peel Strengths
Good High Temperature Performance
Good Chemical Resistance
Properties of Uncured Material
Chemical Type Epoxy
Appearance Silver Paste
Specific Gravity 1.38
Toxicity Low
Solids 100%
Viscosity @ 25ºC, cP 900,000
Thixotropic Index 3.01
Peel Strength, PLI 48
Typical Curing Performance
Cure Speed
Heat is required to cure the epoxy. The cure time is
dependent on the temperature used. The following is
time required to cure the epoxy at different
temperatures.
Temperature, oC Cure Time, minutes
121 45
163 30
177 15
200 10
Technical data contained within this document is intended for reference only
For assistance and recommendations on specifications for this product, contact ND Industries
info@ndindustries.com
11/13/2012 Page 1 of 1
Performance of Cured Material
Typical Values
Shear Strength PSI
Steel 5,000
Galvanized 4,500
Aluminum 3,900
Environmental and Fluid Resistance
(Shear strength values)
Typical Values
Heat age 100%
Environmental Cycles 90%
Humidity 90%
Salt Spray 90%
SAE J2334 80%
General Information
Storage
Product should be stored in cool, dry conditions.
VIBRA-TITE 930 when un-mixed has a shelf life of
12 months when stored at 25°C. Storage in cool,
clean areas is recommended. Usable shelf life may
vary depending on method of applications and
storage conditions.
Note
The data are furnished for information only and are
believed to be reliable. We cannot assume
responsibility for the results obtained by others over
whose methods we have no control. It is
recommended that the product be tested in the
application for which it is to be used.