Viavi T-BERD 5800 User Manual

Page 1
Quick Card
T-BERD 5800 Network Tester
SONET Bit Error Rate Testing (BERT)
This quick card describes how to configure and run a SONET Bit Error Rate Test at the full concatenated line rate. Please note that the T-BERD can also test channelized payloads (DS1, VT1.5, and STS-n). Please refer to the T-BERD 5800 User’s Guide for more information.
Equipment Requirements:
T-BERD 5800 equipped with the following:
o BERT software release V26.2 or greater o Test options:
C5LSSONSDH: OC-3/OC-12 option C525GSONSDH: OC-48 option C510GSONSDH: OC-192 option
Optical Transceiver supporting the Optical Carrier level to be
tested (SFP or SFP+)
LC Attenuators (5dB, 10dB, and/or 15dB)
Cables to match the optical transceiver and the line under test
Fiber optic inspection microscope (P5000i or FiberChek Probe)
Fiber optic cleaning supplies
The following information is required to complete the test:
Optical wavelength (typically 1310nm or 1550nm)
Optical Carrier Level (OC-3, OC-12, OC-48 or OC-192)
Test Pattern(s) (default is 2^23-1 ANSI)
BER Pass/Fail Threshold
Figure 1: Equipment Requirements
Fiber Inspection Guidelines:
Inspect and clean (if necessary) both sides of every fiber optic connection being used (bulkhead connectors, patch cords, SFP ports, etc.) prior to reconnection for each test. Using the VIAVI P5000i or FiberChek Probe inspection microscope:
Focus the fiber on the screen. If dirty, clean the connector.
If it appears clean, run the inspection test.
If the test fails, clean the fiber and re-run inspection test. Repeat until it
passes.
To inspect SFP ports with the P5000i, insert the FBPT-LC probe tip into the
SFP, move the focus wheel all the way to one end, and slowly move the focus wheel to the other end.
To inspect SFP ports with the FiberChek Probe, insert the FBPT-LC probe
tip into the SFP, manually focus with middle toggle switch, or pull the trigger to auto-focus.
If a fiber stub (a darker circle on a lighter background as shown in figure 3)
is detected, follow standard inspection and cleaning procedures. If you are unable to focus on a fiber end face, do not clean the port. The SFP contains a lens and cannot be cleaned.
Figure 2: FiberChek Probe
Figure 3: Image of Clean Fiber
Page 2
Setup Test:
1. Press the Power button to turn on the
test set.
2. Press the Test icon at the top of the
screen.
3. Using the Select Test menu, Quick Launch
menu, or Job Manager, launch the SONET Bulk BERT test on Port 1 for the desired Optical Carrier level. For Example:
SONETOC-3STS-3c Bulk BERTP1 Terminate.
Figure 4: Launch Screen
4. Tap to open the Tools Panel and select
.
5. Press to continue.
6. Press the Setup soft key, , on the top
right side of the screen.
Figure 5: Tools Panel
7. Review SFP information in the Connector
tab:
Verify that the SFP operates on the
required wavelength (1310nm or 1550nm).
Verify that the SFP supports the required
optical carrier level (OC-3, OC-12, OC-48, or OC-192).
Note the Min and Max Tx Levels (dBm)
and Max Rx Level (dBm) to assess if optical attenuators are required.
Figure 6: SFP Information
8. Tap the Signal tab at the top of the display and set Clock Source to “Recovered” unless you are
testing dark fiber with no SONET equipment.
9. Press the Results soft key to view the Test Results screen.
Page 3
Connect to line under test:
Insert desired SFP into the Port 1 slot on the top of the T-BERD.
Inspect and, if necessary, clean all SFPs, attenuators, fibers, and bulkheads, as described on page 1.
If necessary, insert optical attenuators into the SFP TX and/or RX ports.
Connect the SFP to the port under test using a jumper cable compatible with the line under test.
Figure 7: T-BERD 5800v2 Dual Port mainframe
Figure 8: T-BERD 5800-100G mainframe
Run Test:
1. Using the drop-down menus, select
Payload/BERT” for the right Results display.
2. Select the Laser tab in the Actions panel, and
press . The button will turn yellow and
be relabeled .
3. Press the Restart soft key .
4. Verify the following:
Summary LED is green
Signal Present LED is green
Frame Sync LED is green
Path Pointer Present LED is green
Pattern Sync LED is green
Summary/Status results shows
‘ALL SUMMARY RESULTS OK”
Figure 9: Test Results Screen
Page 4
Contact Us +1 844 GO VIAVI)
(+1 844 468 4284)
To reach the VIAVI office nearest you, visit viavisolutions.com/contacts.
© 2018 VIAVI Solutions Inc. Product specifications and descriptions in this document are subject to change without notice.
5. Allow the test to run for desired duration
and verify the following:
Bit/TSE Error Rate result does not
exceed your required threshold (0.00E+00 if pass/fail threshold unknown)
Figure 10: Payload/BERT Results
6. In the T-BERD’s Quick Config menu,
change Patternto the next value in the test plan.
7. Press the Restart soft key to reset
results.
8. Allow test to run for desired duration and
verify the following:
Pattern Sync LED is green
Bit/TSE Error Rate does not exceed
your required threshold (0.00E+00 if pass/fail threshold unknown)
Figure 11: Test Plan
9. Repeat steps 6 through 8 for all Patterns in the test plan. Patterns may include:
Delay: Measures Round Trip Delay (RTD) instead of Bit Errors. RTD values are shown instead of BER
in the “Payload/BERT” results display.
Troubleshooting Tips:
If the Signal Present LED is not green, check your cables. Tx and Rx may be reversed.
If the Path Pointer Present LED is not green and AIS-P alarm is on, there may be no loop, no
connectivity to the loop, or the wrong payload may be selected (concatenated vs. channelized).
If RDI-L alarm is on, the Tx Level is too high. Add an attenuator between the SFP Tx port and the
line under test.
If Path Pointer Adjustments is incrementing, Clock Source is set incorrectly. Change Clock
Source to Recovered.
Loading...