STOR-96 and 912-G-W-1RH 0311
VESTIL MANUFACTURING CORP.
2999 N. Wayne St., Angola, IN 46703
Ph: 260-665-7586 · Fax: 260- 665-1339
E-mail: sales@vestil.com · Website: www.vestil.com
STORAGE SHED MODELS: STOR-96-G-W-1RH & STOR-912-G-W-1RH
Introduction………………………. ……………….… 1
Assembly Instructions STOR-96-G-W-1RH .………..
Assembly Instructions STOR-912-G-W-1RH……...…8
2
STOR-96-G-W-1RH Exploded Parts Diagram & parts
List…………………………………………….…… 17
STOR-912-G-W-1RH Exploded Parts Diagram & Parts
List………………………………………………..... 18-19
IMPORTANT NOTES, WARNINGS AND SAFETY INSTRUCTIONS
Ensure that all employees understand and follow these instructions.
Failure to read and understand this owner’s manual before using or
servicing constitutes a misuse of the product. All persons who will
install, use, or care for this product must be familiar with this material.
o Ensure that all information / safety / warning labels stay in place and are
legible.
Do not perform any modifications to the unit without the manufacturer’s
approval. Failure to receive authorization for changes to the equipment
could void the warranty.
Maintenance and repairs are to be done only by personnel qualified to
perform the required work. Consideration will not be given for warranty
repair charges without prior written authorization by the manufacturer.
OWNER’S
MANUAL
RECEIVING INSTRUCTIONS
It is possible that this product
could incur damage during
transit.
Inspect the unit closely when
it arrives. If you see evidence
of damage or rough handling to
either the packaging or to the
product when it is being
unloaded, immediately
note of it on the Bill Of Lading!
It is important that you
remove the product’s packaging
upon its arrival to ensure that
there is no concealed damage
or to enable a timely claim with
the carrier for freight damage.
Also verify that the product
and its specifications are as
ordered.
make a
STOR-96-G-W-1RH
______________________________
STOR-912-G-W-1RH
TOOLS REQUIRED
-7/16” socket or wrench
-1/2” socket or wrench
-5/16” nut driver for drill
-Level
-Eye/Hand protection advised
Note – At least two people
required to assemble this
product; three suggested
Co
pyright 2011 Vestil Mfg. Co. Page 1 of 20
STOR-96 and 912-G-W-1RH 0311
ASSEMBLY INSTRUCTIONS
Review the bill of materials located on page 17. Unpack all materials and verify quantities before starting.
Consult the factory in the event there are any questions or problems at the time of installation, or for
information regarding optional features not covered by the owner’s manual.
---------------------------------------------------------------------------------------
SINGLE STORAGE UNIT MODEL STOR-96-G-W-1RH
Place wooden floor on clean and level surface.
Position back wall as shown above.
Copyright 2011 Vestil Mfg. Co. Page 2 of 20
STOR-96 and 912-G-W-1RH 0311
Secure back wall to the wooden floor using the ¼” X 2” lag bolts into the 5 predrilled holes. Continue holding
back wall until at least two walls are connected together and lagged to the wooden floor.
Install lockstrip to both vertical ends of back wall.
Install one side wall by inserting into the lockstrip just installed on the back wall vertical end.
Copyright 2011 Vestil Mfg. Co. Page 3 of 20
STOR-96 and 912-G-W-1RH 0311
Install 2nd side wall using foot to hold bottom of wall while inserting into lockstrip.
Secure both side walls to the wooden floor using ¼” X 2” lag bolts into the 5 predrilled holes located at the
bottom of each side wall.
Install lockstrips (2) on side walls, then insert front wall into lockstrips. Install lag bolts, ¼” X 2” lag bolts,
utilizing the 5 predrilled holes to secure front wall to the wooden floor.
Copyright 2011 Vestil Mfg. Co. Page 4 of 20
STOR-96 and 912-G-W-1RH 0311
Place roof on top of the storage unit walls and simply pull it down into the channels until it bottoms out.
Secure roof to the front and back walls with 8pc 1” long self-tapping screws. (4 pcs. per wall) These holes are
not predrilled. Space screws evenly across both sides.
Install door hinges on front wall using 4pc , 5/16” X 1” hex head bolts and 2pc threaded plates. (See following
illustrations)
Copyright 2011 Vestil Mfg. Co. Page 5 of 20
STOR-96 and 912-G-W-1RH 0311
Install hinge on front wall using threaded plate, threaded plate must be
located inside slot as shown. (see Step 11a) Install 4pc – 5/16” nut onto ends of 5/16” X 1” hex head bolts (two
bolts and nuts per hinge). Nuts not shown.
Install door to hinge using re-enforcing hinge plates(2), and 6 pc -¼”X1”carriage bolt, ¼” lock washer and
¼”nut per hinge. Align and tighten. Hinge plates must be inside building as shown.
Install locking bar. Use 6pc of ¼”X 1” carriage bolts, 6pc 5/16” washers, 6pc ¼” washers and 6pc ¼” nuts as
shown above. Rounded head of carriage bolts will be on the outside of the building.
Copyright 2011 Vestil Mfg. Co. Page 6 of 20