IMPORTANT
Before aempng to carry out any maintenance or repair work on our
units, the unit MUST BE COMPLETELY ISOLATED from its electrical supply.
Ensur
e a minimum of two minutes aer electrical disconnecon before
a
empng access. This will allow any moving parts to come to a rest.
VES Andover Ltd Eagle Close Chandlers Ford Ind. Est Eastleigh Hampshire SO53 4NF
Tel: 08448 15 60 60 Fax: 02380 261204 e-mail: vesltd@ves.co.uk web: www.ves.co.uk
Original Instrucons : Installaon, Operaon & Maintenance Manual
WEEE Direcve
Ahe endoheir useful lifethe packaging andproduct should
be disposedof viaasuitable recyclingcentre. Donot dispose of
with normalhousehold waste. Do not burn.
Standards
MERA fans conform to all relevant Brish and European
standards and direcves. Further informaon is available
from VES Andover Ltd on request
Please ensurethahis documens passedon to the enduser
We reserve the right to alter the specificaon without noce
©VES Andover Ltd. 2010. No part of this publicaon may be
photocopied or otherwise reproduced without the prior
permission in wring of VES Andover Ltd.
Maintenance
1. Before cleaning, isolate the fan completely from the mains supply.
2. Carefully remove the front cover
3. T
o clean the front cover, either wipe it with a damp, lint free cloth or
wash it in warm soapy water. Thoroughly dry the front cover and refit.
4. Do not immerse the fan in water or other liquids to clean any other parts
of the fan.
5. Never use strong solvents to clean the fan.
6. Apart from cleaning, no other maintenance is required.
For replacement fans or install kits please visit www.vesdirect.co.uk
Specificaon
Power Supply 230VAC 50Hz
Operang Temperature 0~40°C
Insulaon Class 1
Motor Protecon IP rated to X2
gniraeBepyT rotoM
0241)mpr( deepS
63)W( rewoP
51.0)A( tnerruC
Warranty
The fan is guaranteed against defects for 1 year from the date of purchase.
If you have any problems, contact VES at the address shown below.
Original Instrucons : Installaon, Operaon & Maintenance Manual
Wire the fan as per
wiring diagram &
instrucons
Prepare hole in
mounng surface &
plug mounng holes as
required
Replace snap on front
cover
Installaon connued
Secure fan body
mounng surface
Original Instrucons : Installaon, Operaon & Maintenance Manual
Wiring Diagrams
Standard Wiring
(Typical Installaon)
Operaon
The MERA250 fan
To iniate the extract
mode pull the switch once, to reverse the fan pull twice, and pull a third
me to stop the fan. Ensure that excessive force is not used when pulling
the switch as this may damage the unit.
is reversible and can operate in extract or supply mode.
Mode selecon is achieved via the pull cord switch.
IMPORTANT
All electrical work should be carried out by a qualified engineer and in
accordance with the current IEE Regulaons.
Before aempng to carry out any maintenance or repair work on our
units, the unit MUST BE COMPLETELY ISOLATED from its electrical supply.
Ensure a minimum of two minutes aer electrical disconnecon before
aempng access. This will allow any moving parts to come to a rest.
Fuse
Double Pole
Isolang Switch
L
N
E
Fan
Terminals
Not Used
L
N
E
IMPORTANT
The fan must be fused at 3A unless it forms part of a 5A lighng circuit.
An isolator should be installed to isolate all poles to the fan. Please note the
integral pull cord switch does not isolate the fan from the electrical supply.
Using the fan chasis as a
template, mark centre holes
on mounng surface
Remove the front cover
from the fan by hand - tools
not required
x1
x2 x3