NetSure™ 5100 Ordering Guide
-48V DC Power System 582137100, 58870530036
Page 2
NetSure™ 5100 Ordering Guide
Description
The NetSure™ 5100 Series, a compact -48 volt 600 A DC power solution, features an advanced control unit, up to (29) positions for 2000 W high-eiciency eSure™ rectifiers or 1500 W -48 V to +24 V converters or 2000 W solar converters, a single, bulk or dual row distribution cabinet, and hybrid and solar connectivity panels. The power system supports 19" W and 23" W rack mounting and is available in a number of configurations, designed to work with a wide range of applications.
The distribution cabinet supports up to (52) 1 A to 300 A circuit breakers or 1 A to 100 A TPS/TLS fuses. Options for battery disconnect breaker positions and dual voltage (-48 V/+24 V) breaker positions are available. Multiple LVD levels are supported, allowing load prioritization in up to two steps.
Remote monitoring and control is supported through multiple web browsers including IE, Firefox, Chrome and Safari. Standard supported protocols include
ModBus and SNMP. Encrypted security is also available as an option. Local access is provided through the controllers’ keypad and TFT display. NetSure DC Power systems from Vertiv oer extremely low failure rates, as well as low total cost of ownership. The 2000 W eSure™ rectifier delivers peak system eiciency above 96%. Maximum value is achieved by an advanced energy optimization function known as ECO mode, enabling significant energy savings even at low loads.
Table of Contents
Step 1. Choose Distribution Cabinet or Bulk Power Shelf ...........................................3
Step 2. Choose Distribution Panels .................................................................4
Step 3. Choose Distribution/Battery Devices for Selected Distribution Panels ......................6
Step 4. Optional – Choose Adapters & Hardware ...................................................9
Step 5. Optional – Choose Low Voltage Disconnect ................................................9
Step 6. Choose 19" W or 23" W Rectifier/Converter Module Shelves ...............................10
Step 7. Optional – Choose AC Cords .............................................................. 11
Step 8. Choose Controller ......................................................................... 11
Step 9. Optional – Choose Controller Interfaces ...................................................12
Step 10. Optional – Choose 20 Position GMT Fuse Module ........................................12
Step 11. Optional – Choose 19" W or 23" W Relay Rack .............................................13
Step 12. Optional – Choose Battery Tray(s) & Battery Tray Accessories ...........................13
Step 13. Optional – Choose Hybrid Panel & Hybrid Breakers .......................................15
Step 14. Optional – Choose Solar Panel Disconnect Panel & Breakers .............................16
Step 15. Optional – Choose Accessories ...........................................................16
Step 16. Order Rectifiers and Converter Modules .................................................17
Note 1: Click on the step above to jump to that page. Note 2: To return to the Table of Contents, click on the header of any page.
Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20) 2
Page 3
Requester Contact Information:
SUBMIT
Name*
Company*
Addess*
Zip Code*
Email*
Phone*
* These are required fields. Please complete.
Please SAVE this form to
your desktop. Then press the
submit button below
19" W NetSure 5100 DC Power System 23" W NetSure 5100 DC Power SystemeSure Rectifier, R48-2000e3
Step 1. Choose Distribution Cabinet or Bulk Power Shelf
Select one, quantity of one.
List Number
n/a 58870530036
List 20 58213710020 Distribution cabinet, one row, 19" W 4 RU Accepts one distribution panel.
List 21 58213710021 Distribution cabinet, two rows, 19" W 8 RU Accepts two distribution panels.
List 25 58213710025 Distribution cabinet, one row, 23" W 4 RU Accepts one distribution panel.
List 26 58213710026 Distribution cabinet, two rows, 23" W 8 RU
Vertiv™ Part Number
Description Qt y.
Bulk output shelf e/w controller slot, 19" W. Skip to Step 6.
Rack Space
1 RU Stand alone system.
Notes Pictorial
Accepts two distribution panels
including a split bus, dual
voltage panel.
List 27 58213710027 Distribution cabinet, one row, 23" W 4 RU
Accepts one List DF (26) position distribution panel. No LVD can be used with this distribution cabinet.
3Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 4
NetSure™ 5100 Ordering Guide
Step 2. Choose Distribution Panels
Select one per row. Two row cabinet must include (2) panels. Note restrictions.
List Number
List AA 582137100AA
List AB 582137100AB
List AN 582137100AN
Vertiv™ Part Number
Description Qt y. Notes Pictorial
23" W distribution panel, 24 load-position bullet
23" W distribution panel, 26 load-position bullet
19" W distribution panel, 19-position bullet
Mounts in single row cabinet.
Mounts in two row cabinet.
Mounts in single row cabinet.
List AO 582137100AO
List BA 582137100BA
List BB 582137100BB
List BC 582137100BC
19" W distribution panel, 21-position bullet
23" W distribution/battery panel, 18 load/6 battery-position bullet
23" W distribution/battery panel, 6 load/20 battery-position bullet
23" W distribution/battery panel, 16 load/8 battery-position bullet
Mounts in two row cabinet.
Mounts in single row cabinet.
Mounts in two row cabinet (bottom row only).
Mounts in single row cabinet.
4Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 5
Step 2. (continued)
Select one per row. Two row cabinet must include (2) panels. Note restrictions.
List Number
List BD 582137100BD
List BN 582137100BN
List BO 582137100BO
List DA 582137100DA
List DB 582137100DB
Vertiv™ Part Number
Description Qt y. Notes Pictorial
23" W distribution/battery panel, 16 load/10 battery-position bullet
19" W distribution/battery panel, 14 load/5 battery-position bullet
19" W distribution/battery panel, 12 load/9 battery-position bullet
23" W dual voltage distribution panel, (21) 48V/(4) 24V DC load-position bullet
23" W dual voltage distribution panel, (17) 48V/(8) 24V DC load-position bullet
Mounts in two row cabinet (bottom row only).
Mounts in single row cabinet.
Mounts in two row cabinet (bottom row only).
Mounts in 23" W two row cabinet (top row only).
Mounts in 23" W two row cabinet (top row only).
List DC 582137100DC
List DD 582137100DD
List DE 582137100DE
List DF 582137100DF
23" W dual voltage distribution panel, (13) 48V/(12) 24V DC load-position bullet
23" W dual voltage distribution panel, (9) 48V/(16) 24V DC load-position bullet
23" W dual voltage distribution panel, (5) 48V/(20) 24V DC load-position bullet
23" W Distribution panel, 26 Load-position bullet w/return bar
Mounts in 23" W two row cabinet (top row only).
Mounts in 23" W two row cabinet (top row only).
Mounts in 23" W two row cabinet (top row only).
Mounts in single row List 27 cabinet.
5Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 6
NetSure™ 5100 Ordering Guide
Step 3. Choose Distribution/Battery Devices for Selected Distribution Panels
Step 3a. Choose Bullet-Nose Type Circuit Breaker
List Number
Electrical/Mechanical Trip Toggle Handle Bullet Breakers
n/a 101596 1 Black toggle handle Occupies one position.
n/a 101597 3 Black toggle handle Occupies one position.
n/a 101598 5 Black toggle handle Occupies one position.
n/a 101599 10 Black toggle handle Occupies one position.
n/a 101600 15 Black toggle handle Occupies one position.
n/a 101601 20 Black toggle handle Occupies one position.
n/a 101602 25 Black toggle handle Occupies one position.
n/a 101603 30 Black toggle handle Occupies one position.
n/a 101604 35 Black toggle handle Occupies one position.
n/a 101605 40 Black toggle handle Occupies one position.
n/a 121997 45 Black toggle handle Occupies one position.
n/a 101606 50 Black toggle handle Occupies one position.
n/a 101607 60 Black toggle handle Occupies one position.
n/a 101608 70 Black toggle handle Occupies one position.
n/a 101609 75 Black toggle handle Occupies one position.
n/a 121995 80 Black toggle handle Occupies one position.
n/a 138887 90 Black toggle handle Occupies one position, space required.
n/a 101610 100 Black toggle handle Occupies one position, space required.
n/a 516838 125 Black toggle handle Occupies two positions, space required.
n/a 516839 150 Black toggle handle Occupies two positions, space required.
n/a 144884 175 Black toggle handle Occupies two positions, space required.
n/a 121832 200 Black toggle handle Occupies two positions, space required.
n/a 144886 225 Black toggle handle Occupies three positions, space required.
n/a 121836 250 Black toggle handle Occupies three positions, space required.
n/a 149076 300 Black toggle handle Occupies three positions, space required.
Electrical Trip Toggle Handle Bullet Breakers
n/a 102272 1 White toggle handle Occupies one position.
n/a 102273 3 White toggle handle Occupies one position.
n/a 102274 5 White toggle handle Occupies one position.
n/a 102275 10 White toggle handle Occupies one position.
n/a 102276 15 White toggle handle Occupies one position.
n/a 102277 20 White toggle handle Occupies one position.
n/a 102278 25 White toggle handle Occupies one position.
n/a 102279 30 White toggle handle Occupies one position.
n/a 102280 35 White toggle handle Occupies one position.
n/a 102281 40 White toggle handle Occupies one position.
n/a 121998 45 White toggle handle Occupies one position.
Vertiv™ Part Number
Ampere
Rating
Description Qt y. Notes Pictorial
6Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 7
List Number
Electrical Trip Toggle Handle Bullet Breakers
n/a 102282 50 White toggle handle Occupies one position.
n/a 102283 60 White toggle handle Occupies one position.
n/a 102284 70 White toggle handle Occupies one position.
n/a 102285 75 White toggle handle Occupies one position.
n/a 121996 80 White toggle handle Occupies one position.
n/a 138887 90 White toggle handle Occupies one position, space required.
n/a 102286 100 White toggle handle Occupies one position, space required.
n/a 516991 125 White toggle handle Occupies two positions, space required.
n/a 516993 150 White toggle handle Occupies two positions, space required.
n/a 144883 175 White toggle handle Occupies two positions, space required.
n/a 121831 200 White toggle handle Occupies two positions, space required.
n/a 144885 225 White toggle handle Occupies three positions, space required.
n/a 121835 250 White toggle handle Occupies three positions, space required.
n/a 149075 300 White toggle handle Occupies three positions, space required.
Vertiv™ Part Number
Ampere
Rating
Description Qt y. Notes Pictorial
Step 3b. ChooseTLS/TPS Fuses with Bullet-Type Fuse Holders
List Number
n/a 117201
n/a 248230900 3 TLS/TPS fuse Occupies one position.
n/a 248231000 5 TLS/TPS fuse Occupies one position.
n/a 248231200 6 TLS/TPS fuse Occupies one position.
n/a 248231500 10 TLS/TPS fuse Occupies one position.
n/a 248231800 15 TLS/TPS fuse Occupies one position.
n/a 248232100 20 TLS/TPS fuse Occupies one position.
n/a 248232400 25 TLS/TPS fuse Occupies one position.
n/a 248232700 30 TLS/TPS fuse Occupies one position.
n/a 248233300 40 TLS/TPS fuse Occupies one position.
n/a 248233900 50 TLS/TPS fuse Occupies one position.
n/a 248234200 60 TLS/TPS fuse Occupies one position.
n/a 248234500 70 TLS/TPS fuse Occupies one position.
n/a 118413 80 TLS/TPS fuse Occupies one position.
n/a 118414 90 TLS/TPS fuse Occupies one position, fuse holder space required.
n/a 118415 100 TLS/TPS fuse Occupies one position, fuse holder space required.
Vertiv Part Number
Ampere
Rating
Description Qt y. Notes Pictorial
Fuse holder, TLS/TPS, bullet type
Order one fuse holder per fuse.
7Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 8
NetSure™ 5100 Ordering Guide
Step 3c. Choose GMT Fuses with GMT Fuse Module
List Number
n/a 559737
n/a 549017
n/a 248610301 18/100 GMT fuse Occupies one position.
n/a 248610200 1/4 GMT fuse Occupies one position.
n/a 248610300 1/2 GMT fuse Occupies one position.
n/a 248610500 3/4 GMT fuse Occupies one position.
n/a 248610700 1-1/3 GMT fuse Occupies one position.
n/a 248610800 2 GMT fuse Occupies one position.
n/a 248610900 3 GMT fuse Occupies one position.
n/a 248611000 5 GMT fuse Occupies one position.
n/a 248611300 7-1/2* GMT fuse Occupies one position.
n/a 248611200 10* GMT fuse Occupies one position.
n/a 248611500 15 GMT fuse Occupies one position, space required.
Vertiv™ Part Number
Ampere
Rating
Description Qt y. Notes Pictorial
Fuse module, six GMT fuse positions
Fuse module, six GMT fuse positions
Occupies two bullet positions. Mounts in single row distribution panel system or top row of dual row distribution panel system.
Occupies two bullet positions. Mounts in bottom row of dual row distribution panel system.
n/a 102774 Replacement safety cover
n/a 248872600 Replacement dummy fuse Occupies one position.
* Space required when operating at 65 °C.
Step 3d. Choose Bullet Nose Bypass Bus Bar
List Number
n/a 535015 Bullet nose bypass busbar
Vertiv Part Number
Description Qt y. Notes Pictorial
8Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 9
Step 4. Optional – Choose Adapters & Hardware
List Number
n/a 559803 1 Pole Lug adapter kit
n/a 559804 2 Pole Lug adapter kit
n/a 559805 3 Pole Lug adapter kit
n/a 534449 2 Pole Lug adapter kit
n/a 514714 3 Pole Lug adapter kit
n/a 545412 -
Vertiv™ Part Number
Number of Poles
Description Qty. Notes Pictorial
Lug hardware kit
Right angle adapter converts (1) load position (1/4-20 on 5/8" centers) to (1) load landing (1/4-20 on 5/8" centers).
Right angle load busbar and straight return busbar for rear wiring egress converts (2) load positions (1/4-20 on 5/8" centers) to (1) landing (3/8-16 on 1" centers).
Right angle load busbar and straight return busbar for rear wiring egress converts (3) load positions (1/4-20 on 5/8" centers) to (1) landing (3/8-16 on 1" centers).
Includes (1) busbar that mounts on the two lug landing positions of a 125 A, 150 A, or 200 A bullet nose circuit breaker, and provides a landing for one standard two-hole lug having 3/8" bolt clearance holes on 1" centers. Also includes (1) busbar that mounts on two landings of the associated ground return bar (if furnished), and provides one landing for a standard two-hole lug having 3/8" bolt clearance holes on 1" centers. All busbar and lug mounting hardware is included. Order (1) part no. 534449 per 125 A, 150 A, and 200 A bullet nose circuit breaker ordered.
Includes (1) busbar that mounts on the three lug landing positions of a 225 A through 300 A bullet nose circuit breaker, and provides one landing for a standard two-hole lug having 3/8" bolt clearance holes on 1" centers. Also includes (1) busbar that mounts on three landings of the associated ground return bar (if furnished), and provides one landing for a standard two-hole lug having 3/8" bolt clearance holes on 1" centers. All busbar and lug mounting hardware is included. Order (1) part no. 514714 per 225 A through 300 A bullet nose circuit breaker ordered.
(4) 1/4-20 nuts, lock washers, and flat washers.
Step 5. Optional – Choose Low Voltage Disconnect
Select either low-voltage battery disconnect (List LB) or load disconnect (List LL) for a single row panel. For a dual row panel, select either List LB or List LL or select both.
List Number
List LB 582137100LB
List LL 582137100LL
Vertiv Part Number
Description Q ty. Notes
Low voltage battery disconnect
Low voltage
load disconnect
Maximum of one in a system.
Maximum of one in a system. On dual row cabinet contactor only disconnects bottom row.
9Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 10
NetSure™ 5100 Ordering Guide
Step 6. Choose 19" W or 23" W Rectifier/Converter Module Shelves
Select one List 30 for each module shelf chosen except when 58870530036 is chosen. Select one shelf with a controller slot and then select expansion shelves. For conduit input order a List 40, 45 or 46 and the hard-wired module shelves.
19" W NetSure 5100 Shelf 23" W NetSure 5100 Shelf
List Number
List 30 58213710030 Interface components for 1RU module, shelf n/a
List 40 58213710040 19" W AC/Solar input termination panel n/a
List 45 58213710045 23" W AC/Solar input termination panel n/a
List 46 58213710046 23" W AC input termination panel n/a
Module Shelves e/w Controller
n/a 58870530011
n/a 58870530014
n/a 58870530015
n/a 58870530031
n/a 58870530034
n/a 58870530035
Bulk Output Shelf
n/a 58870530036
Module Shelves for Expansion
n/a 58870530021
n/a 58870530024
n/a 58870530025
n/a 58870530041
n/a 58870530044
n/a 58870530045
n/a 58870530001
n/a 58870530004
n/a 58870530005
*When using molex cords and solar converters only one solar converter can be powered per AC Cord.
Vertiv™ Part Number
Description Qt y.
23" W shelf e/w controller slot. Holds (5) rectifier or solar converter modules. Hard-wire AC.
23" W shelf e/w controller slot. Holds (5) rectifier or solar converter modules. Hard-wire AC with cord clamp.
23" W shelf e/w controller slot. Holds (5) rectifier or solar converter modules. Molex cord connectors.
19" W shelf e/w controller slot. Holds (4) rectifier or solar converter modules. Hard-Wire AC.
19" W shelf e/w controller slot. Holds (4) rectifier or solar converter modules. Hard-wire AC withcord clamp.
19" W shelf e/w controller slot. Holds (4) rectifier or solar converter modules. Molex cord connectors.
19" bulk output stand-alone shelf e/w controller slot. Holds (4) rectifier modules. AC input consists of molex cord connectors. Shelf comes with output bus bar lug landing points for customer lugs.
23" W shelf. Holds (6) rectifiers or (3) rectifier and (3) solar converter modules. Hard-wire AC.
23" W shelf. Holds (6) rectifiers or (3) rectifier and (3) solar converter modules. Hard-wire AC with cord clamp.
23" W shelf. Holds (6) rectifiers or (3) rectifier and (3) solar converter modules. Molex cord connectors.
19" W shelf. Holds (5) rectifiers or (2) rectifiers and (3) solar converter modules. Hard-wire AC.
19" W shelf. Holds (5) rectifiers or (2) rectifiers and (3) solar converter modules. Hard-wire AC with cord clamp.
19" Wshelf. Holds (5) rectifiers or (2) rectifiers and (3) solar converter modules. Molex cord connectors.
23" W shelf with (6) positions for rectifiers, solar converters and
-48V to +24V converter modules. Hard-wire AC.
23" W shelf with (6) positions for rectifiers, solar converters and
-48V to +24V converter modules. Hard-Wire AC with cord clamp.
23" W shelf with (6) positions for rectifiers, solar converters and
-48V to +24V converter modules. Molex cord connectors.
Rack Space
1 RU
1 RU For use in Vertiv cabinets.
1 RU For use with Molex AC cords.*
1 RU
1 RU For use in Vertiv cabinets.
1 RU For use with Molex AC cords.*
1 RU
1 RU
1 RU
1 RU
1 RU
1 RU
1 RU
1 RU
1 RU
1 RU
Notes Pictorial
Order one for each module shelf that is ordered other than when the 58870530036 shelf is chosen. Order for individual solar or AC input in conduit. Order for individual solar or AC input in conduit.
Order for AC input in conduit. Each AC feed picks up two rectifiers. For use with up to (3) shelves.
For use with AC input that will be in conduit. Requires List 45 or 46.
For use with AC input that will be in conduit. Requires List
40.
For use with Molex AC cords*. No distribution required. System requires, controller, rectifiers, AC cords.
For use with AC input that will be in conduit. Three left most slots can hold solar converter modules. Requires List 45 or 46.
For use in Vertiv cabinets. Three left most slots can hold solar converter modules.
For use with Molex AC cords. Three left most slots can hold solar converter modules.*
For use with AC input that will be in conduit. Three left most slots can hold solar converter modules. Requires List 40.
For use in Vertiv cabinets. Three left most slots can hold solar converter modules.
For use with Molex AC cords. Three left most slots can hold solar converter modules.*
For use with AC input that will be in conduit. Left three slots set up for solar converters. Right three slots set up for -48V
to +24V converter modules. Requires List 45 or 46.
For use in Vertiv cabinets. Left three slots set up for solar converters. Right three slots set up for -48V to +24V converter modules.
For use with Molex AC cords. Left three slots set up for solar converters. Right three slots set up for -48V to +24V converter modules.*
10Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 11
Step 7. Optional – Choose AC Cords
Select AC cords for molex AC input module shelves.
List Number
n/a 535232
n/a 547898
n/a 553202
n/a 540946
Vertiv™ Part Number
Description Qt y. Pictorial
30" long, 8 AWG, input cable assembly
6' long, 8 AWG, input cable assembly
12' long, 8 AWG,
AC input cable assembly
14' long, 8/3 AWG, AC input line cord, L6-30P
n/a 545252
n/a 545616
14' long, 8/3 AWG, AC input line cord, L5-30P
6' long, 8 AWG, AC input line cord, L6-30P
Step 8. Choose Controller
Select one, quantity of one.
List Number
n/a 1M830BNA NCU controller
Vertiv Part Number
Description Qt y. Notes Pictorial
Standard or special firmware configuration can be assigned. Distribution panel comes equipped with IB2 interface board which provides (8) programmable and mappable output relays, (8) programmable binary inputs and (2) temperature inputs.
11Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 12
NetSure™ 5100 Ordering Guide
Step 9. Optional – Choose Controller Interfaces
Select if desired.
Note: Items below cannot be used with 58870530036 bulk output shelf.
List Number
List 70 58213710070 EIB, extended interface board
n/a 547490
n/a 556155
n/a 552992
n/a 04119122
n/a 559741
Vertiv™ Part Number
Description Qty. Notes Pictorial
SMTEMP, 8 input temperature module
Temperature probe, 3.3m,
includes 0.3 m sensor
Temperature probe, 10.3m,
includes 0.3m sensor
10 m temperature
probe extension
NCU controller second Ethernet
port kit
Maximum quantity of one. Provides (5) relay outputs, (2) temperature inputs, (8) battery mid-point monitoring inputs and (3) shunt inputs. Mounts internal to the system.
Provides (8) temperature inputs. Maximum quantity of eight per system. Mounts external to power system.
Provides temperature monitoring and alarming for battery or ambient. Battery-assigned probes provide temperature compensation and battery thermal runaway management.
Provides temperature monitoring and alarming for battery or ambient. Battery-assigned probes provide temperature compensation and battery thermal runaway management.
Provides 10 meter extension for temperature probe.
Provides dual Ethernet feature - one static and one dynamic
n/a 555877 Critical LED Kit Illuminates for a critical alarm.
n/a 431300200
n/a 431300300
n/a 535135
n/a 424227900
n/a 424228000
n/a 424228100
1 amp in-line fuse pigtail kit with
3/8" ring lug
1 amp in-line fuse pigtail kit with
5/16" ring lug
In-line fuse pigtail kit with splice connector, 3/8" ring lug, and 1/4"
ring lug
In-line 49.9 ohm resistor pig-tail
kit with 3/8" ring lug
In-line 49.9 ohm resistor pig-tail
kit with splice connector
In-line 49.9 ohm resistor pig-tail
kit with 5/16" ring lug
Used for connecting to battery or bus potentials for use with digital inputs on IB2 Interface board and battery midpoint/block voltage inputs on the EIB extended interface board. Used for connecting to battery or bus potentials for use with digital inputs on IB2 Interface board and battery midpoint/block voltage inputs on the EIB extended interface board. Used for connecting to battery or bus potentials for use with digital inputs on IB2 Interface board and battery midpoint/block voltage inputs on the EIB extended interface board.
Used for connecting to shunts for use with the EIB extended interface board and SMDU+ shunt interface board.
Used for connecting to shunts for use with the EIB extended interface board and SMDU+ shunt interface board. Used for connecting to shunts for use with the EIB extended interface board and SMDU+ shunt interface board.
Step 10. Optional – Choose 20 Position GMT Fuse Module
Note: Not available with 58870530036 bulk output shelf.
List Number
List KG 582137100KG (20) position GMT fuse panel Mounts below last rectifier shelf
Vertiv™
Part Number
Description Q ty. Notes
12Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 13
Step 11. Optional – Choose 19" W or 23" W Relay Rack
Select one, quantity of one.
List Number
n/a 559817 Relay rack, 51.906"H x 24.376"W x 15"D 28 RU 23" W - Welded.
n/a 559819 Relay rack, 84.000"H x 25.000"W x 15"D 45 RU 23" W - Seismic.
n/a 559818 Relay rack, 72.000"H x 24.375"W x 15"D 37 RU 23" W - Welded.
n/a 559820 Relay rack, 84.000"H x 24.375"W x 15"D 45 RU 23" W - Welded.
n/a 559821 Relay rack, 90.000"H x 24.375"W x 15"D 48 RU 23" W - Welded.
n/a 559822 Relay rack, 96.000"H x 24.375"W x 15"D 51 RU 23" W - Welded.
n/a 562353 Relay Rack, 84.000”H x 25.800”W x 18”D 45 RU 23" W - Seismic*
n/a 559824 Relay rack, 84.000"H x 21.000"W x 15"D 45 RU 19" W - Welded.
n/a 559823 Relay rack, 84.000"H x 20.375"W x 15"D 45 RU 19" W - Seismic.
n/a 563922 Relay rack, 84.000”H x 21.800”W x 18”D 45 RU 19" W - Seismic*
* For power systems mounted in relay racks with more than one battery tray.
Vertiv™ Part Number
Description Q ty. Rack Space Notes
Step 12. Optional – Choose Battery Tray(s) & Battery Tray Accessories
Select one List 93 or List 94 and up to (4) trays as space and restrictions apply. Select battery disconnect and lugs if required.
Note: Not to be ordered with 58870530036 bulk output shelf.
List Number
List 93 58213710093 -
Vertiv Part Number
Amp Rating Description Qty. Rack Space Notes Pictorial
Battery tray mounting kit
-
n/a 559808 -
n/a 559806 -
n/a 559807 -
List 94 58213710094 -
n/a 559809 -
Battery tray for front terminal batteries, max battery size
11.3" x 4.3" x 21.7" (H x W x L)
Battery tray for front terminal batteries, max battery size
12.8" x 4.96" x 22.51" (H x W x L)
Battery tray for front terminal batteries, max battery size
11.60" x 4.20" x 11.3" (H x W x L)
Battery tray mounting kit
Battery tray for front terminal batteries, max battery size
11.3" x 4.25" x 15.59" (H x W x L)
6 RU, 7 RU or 8 RU
6 RU, 7 RU or 8 RU
6 RU, 7 RU or 8 RU
-
7 RU or 8 RU
For 23" W mounting.
For 23" W mounting.
For 23" W mounting. Not to be used in relay rack 562353.
For 19" W mounting.
13Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 14
NetSure™ 5100 Ordering Guide
Step 12. (continued)
List Number
n/a 559810 -
n/a 559811 -
n/a 559812 -
n/a 559814 -
n/a 559813 -
n/a 559816 -
n/a 559815 -
n/a 256694300 50 Electrical/mechanical trip breaker -
n/a 256694700 60 Electrical/mechanical trip breaker -
n/a 256695100 70 Electrical/mechanical trip breaker -
n/a 256695500 75 Electrical/mechanical trip breaker -
n/a 256695900 100 Electrical/mechanical trip breaker -
n/a 100765 125 Electrical/mechanical trip breaker -
n/a 100763 150 Electrical/mechanical trip breaker -
n/a 121810 200 Electrical/mechanical trip breaker -
Vertiv™ Part Number
Amp Rating
Description Qt y.
Battery tray for front terminal batteries, max battery size 9.4" X 4.33" X 20.12" (H x W x L)
Battery tray for front terminal batteries, max battery size 11.6" X 4.2" X 11.3" (H x W x L)
Battery tray for front terminal batteries, max battery size 12.4" X 4.3" X 22.1" (H x W x L)
Single pole battery disconnect box, left side of rack
Single pole battery disconnect box, right side of rack
Two pole battery disconnect box, left side of rack
Two pole battery disconnect box, right side of rack
Rack Space
7 RU For 19" W mounting.
6 RU, 7 RU or 8 RU
8 RU
-
-
-
-
Notes Pictorial
For 19" W mounting. Not to be used in relay rack 563922.
For 19" W mounting. Not to be used in relay rack 563922.
Requires battery disconnect box 559814 or 559813.
Requires battery disconnect box 559816 or 559815.
n/a 528234 - 2 AWG battery lug kit - 90 degree.
n/a 528235 - 1/0 AWG battery lug kit - 90 degree.
n/a 528236 -
n/a 528237 -
2 AWG long tongue
battery lug kit
1/0 AWG long tongue
battery lug kit
- 90 degree.
- 90 degree.
14Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 15
Step 13. Optional – Choose Hybrid Panel & Hybrid Breakers
Select one hybrid panel and up to (5) breakers. Four of the breakers can be three pole and one can be up to two poles.
List Number
List 60 58213710060 23" W Hybrid input breaker panel 5 RU
Electrical/Mechanical Trip Breakers
n/a 123580 100A E/M breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 123631 125A E/M breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 123632 150A E/M breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 123633 175A E/M breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 123634 200A E/M breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 123635 225A E/M breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 123636 250A E/M breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 550250 300A E/M breaker e/w shunt - Two pole breaker, 25mV shunt.
n/a 550251 400A E/M breaker e/w shunt - Two Pole breaker, 25mV shunt.
Vertiv™ Part Number
Description Qty.
Rack Space
Notes Pictorial
Requires 23" W relay rack. Not to be ordered stand-alone or with the 58870530036 bulk output shelf.
n/a 550252 600A E/M breaker e/w shunt - Three pole breaker, 25 mV shunt.
Electrical Trip Breakers
n/a 516184 100A E breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 516187 125A E breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 516185 150A E breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 516186 175A E breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 516188 200A E breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 516189 225A E breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 516190 250A E breaker e/w shunt - Single pole breaker, 25mV shunt.
n/a 550253 300A E breaker e/w shunt - Two pole breaker, 25mV shunt.
n/a 550254 400A E breaker e/w shunt - Two Pole breaker, 25 mV shunt.
n/a 550255 600A E breaker e/w shunt - Three pole breaker, 25mV shunt.
15Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 16
NetSure™ 5100 Ordering Guide
Step 14. Optional – Choose Solar Panel Disconnect Panel & Breakers
Select one or two solar panels and up to (16) breakers.
Note: Not to be used with the 58870530036 bulk output shelf.
List Number
List 61 58213710061 23" W solar input breaker panel 5 RU
n/a BMY2300074/1 20A solar panel breaker 5 RU (8) breakers per panel.
Vertiv™ Part Number
Description Qty.
Rack Space
Notes Pictorial
Mounts below rectifier shelves or hybrid panel.
Step 15. Optional – Choose Accessories
List Number
n/a 559801
List 33 58213710033
List 34 58213710034
Vertiv Part Number
Description Qty.
Flush mounting kit for data cabinet
23" W field expansion shelf kit for rectifiers, solar converters and -48V to +24V DC converters
23" W field expansion shelf kit for rectifiers and solar converters
Rack
Space
1 RU
1 RU
Notes Pictorial
Molex AC input. Not to be used with the 58870530036 bulk output shelf.
Molex AC input. Not to be used with the 58870530036 bulk output shelf.
List 36 58213710036
n/a 562050 19" W AC cord bracket N/A Mounts on rear of relay rack.
n/a 563456 23" W AC cord bracket N /A Mounts on rear of relay rack.
19" W field expansion shelf kit for rectifiers and solar converters
1 RU
Molex AC input. Not to be used with the 58870530036 bulk output shelf.
16Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 17
Step 16. Order Rectifiers and Converter Modules
SUBMIT
See user and instruction manuals for de-rating information due to temperature.
List Number
n/a 1R482000E3
n/a 1C48241500
n/a 1S482000E3
n/a SXA1100035/1
Vertiv™
Part Number
Comments
Description Qty.
High-efficiency rectifier R48-2000e3, 48 VDC, 2000 watts
High-efficiency converter C48/24-1500, -48 to +24 VDC, 1500 watts
High-efficiency solar converter S48-2000e3, 48 VDC, 2000 watts
Blank cover for 1 RU rectifier, converter or solar converter
Rack Space
1 RU Provides 41.7 amps at 48 VDC.
1 RU Provides 62.5 amps at 24 VDC .
1 RU Provides 41.7 amps at 48 VDC .
1 RU
Notes Pictorial
Optional cover for empty 1RU rectifier, converter or solar converter position.
Please SAVE this form to your desktop. Then email the completed form to: AccountManagement.ESNA@Vertiv.com
Contact your local sales representative with questions or call 1-800-800-1280 for support.
17Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 18
NetSure™ 5100 Ordering Guide
This page is intentionally blank.
18Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 19
This page is intentionally blank.
19Vertiv | NetSure™ 5100 | Ordering Guide (RB02/20)
Page 20
Vertiv.com | Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA
© 2020 Vertiv G roup Corp. All right s reserved. Vertiv ™ and the Vertiv logo are tr ademarks or regis tered trademarks of Ver tiv Group Corp. All o ther names and log os referred to are trade n ames, trademar ks or registered tra demarks of their res pective owners . While every precauti on has been taken to en sure accuracy and c ompleteness he re, Vertiv Group Cor p. assumes no resp onsibility, and dis claims all liabili ty, for damages resu lting from use of this inf ormation or for any erro rs or omissions . Specificatio ns, rebates and oth er promotional oers are su bject to change at Ver tiv’s sole discret ion upon notice.
DC-00105 (RB02/20)
Loading...