Vertiv Liebert EFC 220, Liebert EFC 300, Liebert EFC 320, Liebert EFC 400, Liebert EFC 440 User manual

Liebert® EFC
from 100 to 450 kW
The Highly Eicient Indirect Evaporative Freecooling Unit
Liebert® EFC from 100 to 450 kW
Vertiv™ brings together hardware, software, analytics and ongoing services to ensure its customers’ vital applications run continuously, perform optimally and grow with their business needs.
Vertiv solves the most important challenges facing today’s data centers, communication networks and commercial and industrial facilities with a portfolio of power, cooling and IT infrastructure solutions and services that extends from the cloud to the edge of the network.
Headquartered in Columbus, Ohio, USA, Vertiv employs around 20,000 people and does business in more than 130 countries. For more information, and for the latest news and content from Vertiv, visit Vertiv.com.
Liebert® EFC, the Highly Eicient Indirect Evaporative Freecooling Solution
The Liebert EFC is equipped with the most advanced industry technology. The system includes indirect air-to-air heat exchange and evaporative cooling technology all in one footprint. The Liebert EFC is capable of reducing air temperatures by leveraging on the evaporative cooling principle.
The process involves the evaporation of water which, as a consequence, cools the surrounding air. Through this technology, the Liebert EFC can thus achieve pPUE levels of 1.03 ensuring top energy eiciency, as well as minimized operating costs.
Liebert EFC 300Liebert EFC 220 Liebert EFC 320
Liebert EFC 400 Liebert EFC 440
2
Optimized Water Consumption
Data Center Freefrom Contaminations
1.03
Top Energy Eiciency Levels pPUE down to 1.03
<
Reduced Electrical Infrastructure
$
Reduced Capital Cost
Technical Expertise
Supplying indirect freecooling for data center applications
via the evaporative technology.
3
Liebert® EFC from 100 to 450 kW
Liebert® EFC: Enhancing Data Center Eiciency
Evaporative Cooling
The highly eicient evaporative system sprays water onto the heat exchanger to enable cooling even at high ambient air temperatures, without the need for mechanical cooling.
Highly Eicient EC Fans
The new generation of fans installed in the Liebert EFC dramatically reduce the noise level and increase the overall eiciency of the unit.
Reduced CO2 Emissions
At pPUE levels of 1.03, Liebert EFC requires minimum power input consequently reducing CO2 emissions.
Energy Eiciency
The evaporative cooling technology enables Liebert EFC to reach pPUE levels as low as 1.03.
Eurovent Certified Heat Exchanger
Eurovent certification guarantees that Liebert EFC heat exchangers undergo independent testing, thus delivering rating accuracy and enhancing the unit's reliability.
Freecooling
Evaporative cooling extends indirect freecooling operation all year round.
Data Center Free from Contaminations
The air-to-air heat exchanger separates external and internal air, protecting the data center air from bacterial contamination, as well as other external events such as fire and pollution.
Liebert® iCOM™
Liebert® iCOM™ Control ensures high level management of the units to work together as a single system, thus optimizing room temperature and airflow.
Integrated Chilled Water Coil and Direct Expansion System
These technologies ensure the unit's operation even in climates characterized by extreme humidity levels or severe temperature peaks.
Partial Load Eiciency
New generation EC fans and integrated digital scroll compressors contribute to achieving the highest eiciency levels at partial load.
4
The evaporative system has a dedicated internal pump that provides the water needed.
Water is sprayed through special nozzles onto the heat exchanger and evaporates, thus humidifying and cooling the air.
5
Liebert® EFC from 100 to 450 kW
Temperature (°C)
%
%
Absolute Humidity (g/kg)
35 40 45 50 55
Ensuring Top Eiciency Levels through the Evaporative Principle
The Liebert® EFC combines the capabilities of freecooling and evaporative cooling principles in one single unit. It has been specifically designed to select the most appropriate operating mode based on the external environment conditions, leveraging both principles in order to deliver significant energy savings.
The use of the evaporative cooling, hence using cold external air as a means of cooling, allows freecooling operation to be maximized and compressor-related cooling to be reduced to a minimum, thus optimizing operating costs.
30
25
The evaporative principle uses air to absorb water that is sprayed through special nozzles onto the heat exchanger. Water evaporation, thus removes heat from the air and cools the outside air temperature.
30
Outside air consequently transitions from Dry Bulb Temperature to Wet Bulb Temperature (the graph below shows the transition from 35°C to 20°C).
100% 90%80% 70%60% 50%40%
30
20
15
10
25
20
15
10
5
5
-5
0
50-5-10 10 15 20 25 30 35 40 45 50 55
( 35°C DB ; 20°C WB )
Psychrometric Chart for Sea-Level Elevation
20
10%
6
Where Indirect Evaporative Cooling Works
In order to optimize the overall system eiciency, the Liebert® EFC has been designed to change its operation mode according to the external environment. When the external air is cold enough to allow freecooling, the unit works in dry operation mode (winter operation mode).
When ambient temperatures are higher, also external humidity determines unit capacity and performances as the evaporative eect is directly associated to the external air capacity to absorb water.
When the unit operates in environments with higher temperature and lower relative humidity (summer operation mode), Liebert EFC works in evaporative (wet) mode.
In climates featuring high levels of humidity the unit may thus require the integration of a Direct Expansion (DX) system or the installation of a Chilled Water (CW) coil (extreme operation mo de).
DRY OPERATION
(Dry Bulb Temperature
<17°C -20°C)*
The unit can cool the data center
solely via the air-to-air heat exchanger, thus using only cold external air.
WET OPERATION
(Wet Bulb Temperature
<20°C - 22°C)*
The unit can leverage the
evaporative eect via humidification.
DX/CW
INTEGRATION
WET
DRY
OPERATION
Dry Bulb Temperature, °C
*Assumptions: data center 36°C 24° C - 100% of full load per unit (redundancy operation)
OPERATION
DX/CW
INTEGRATION
External humidity assumes a key role in determining unit performances:
Moisture Content, kg/kg Dry Air
y At 24°C and 90% relative
humidity, the unit may require DX/CW integration.
y At 35°C (higher temperature)
and 25% (lower relative humidity), the unit can solely operate with evaporative cooling.
7
Liebert® EFC from 100 to 450 kW
DC Hot Return Air
DC Supply Air
Externel Air
Exhaust External Air
DC Hot Return Air
Externel Air
DC Hot Return Air
DC Supply Air
Externel Air
Exhaust External Air
Liebert® EFC Operation Modes In Detail
Winter
The use of the evaporative cooling, hence using cold external air as a means of cooling, allows freecooling operation to be maximized and compressor-related cooling to be reduced to a minimum, thus optimizing operating costs.
DC Hot Return Air
Externel Air
Exhaust External Air
DC Supply Air
DRY OPERATION
Air-to-Air Heat Exchange Without Spraying Water
Summer
During the warm season (summer operation mode) the evaporative system must run in order to saturate the air. Thisenables the unit to cool the data center air even with high external air temperatures. By saturating the air, the dry bulb temperature can be reduced.
Optional
In case of extreme external conditions, a Direct Expansion (DX) system is available to provide additional cooling. As an alternative, the Chilled Water (CW) coil can be installed. DX and CW systems are sized to provide partial back up for the overall cooling load and are designed to provide maximum eiciency with minimum energy consumption.
DC Hot Return Air
Externel Air
DC Hot Return Air
Externel Air
Exhaust External Air
Exhaust External Air
DC Supply Air
DC Supply Air
WET OPERATION
Air-to-Air Heat Exchange Via the Spraying of Water to the External Air Side
DX/CW INTEGRATION
External Air Is too Hot to Achieve 100% Cooling with Adiabatic, the DX Module Is thus Integrated to Cover the Missing Capacity
8
The State-of-the-Art Liebert® iCOM™ Control
50-5-10 10 15 20 25 30 35 40 45 50 55
Temperature (°C) in the Data Center
100%90% 8 0% 70% 60% 50% 40%
30%
20%
10%
5
10
15
20
25
30
Absolute Humidity (g/kg) in the Data Center
2004
ASHRAE
Recommended
2011
ASHRAE
Recommended
A1
A2
A3
A4
Precise, User-friendly Information at Unit Level
To guarantee ASHRAE
recommended guidelines even at extreme conditions
y Extreme Winter Operation
(i.e.below-20°C) can cause the unit's unrequired internal dehumidification causing it to exceed ASHRAE recommended minimum humidity. Liebert® EFC oers a constant control of data center air via its integrated Liebert® iCOM™ control logic, ensuring dew point temperature is lower than heat exchanger surface temperature, thus avoiding unrequired dehumidification.
To provide precise temperature
and airflow control in front of servers
y The Vertiv SmartAisle™ control
logic embedded in the Liebert® iCOM™ optimizes internal air volumes and temperatures according to specific server needs. VertivSmartAisle logic allows Liebert EFC to exactly match the servers' airflow needs, ensuring that not even a single Watt is wasted in moving or cooling unrequired air.
To optimize water and
electricity costs with the Cost Function software feature
y The user friendly Liebert®
iCOM™ Control exploits the management of energy and water also at teamwork level.
The system collects
information from the dierent units’ key parameters and operating modes (dry, wet and DX/CW) while taking into account water and electricity costs. The control predictively calculates and then implements the combination which optimizes operating costs.
Utmost Eiciency Even at the Data Center System Level
The Liebert® iCOM™ Control manages the operation of the Liebert EFC units, in order to ensure top reliability in all conditions. Accessto the units installed in the data center, is granted through the Ethernet connection, that is capable of coordinating the multiple on-site installations. The high-level supervision of multiple units allows these to work together as a single system, thus optimizing overall system performance.
9
Liebert® EFC from 100 to 450 kW
High Flexibility Matching Customer Needs
The Liebert® EFC delivers substantial reductions and savings in terms of electrical infrastructure and equipment. With the unit being installed externally, the available internal white space is maximized ensuring ease of system installation. All of these features significantly reduce data center TCO.
Main Options Available Benefits
Water storage reduction
DX or CW coil for mechanical cooling integration
G4 or M5 data center air filter State-of-the-art filtration class
Low ambient kit To avoid unrequired dehumidification at very low ambient temperatures
Automatic transfer switch with intelligent controller Due to the communication with the unit control, all the electrical power data is monitored through the BMS
Dehumidification availability
Premium efficiency
Delivery temperature guaranteed also under the worst ambient conditions
UltraCapacitor Control always active even during a power failure
Monitoring Integrated BMS interface (i.e. ModBus, Bacnet and SNMP)
Energy meter/water meter To manage energy and water consumption, thus optimizing operating costs
Right and left versions available in both perimeter and roof configurations
Perimeter Configuration Roof Configuration
To adapt to any data center layout
Multi-Storey Configuration
10
Annual Distribution of Operating Modes with Indirect Evaporative Freecooling
600
Hours per Year
Hours per Year
Hours per Year
Ambient Air Temperature
While respecting ASHRAE guidelines, the Liebert® EFC unit can be installed not only in cold climates, where the unit can leverage on the dry operating mode, but also in hotter ones (as shown in the example below for Istanbul) where DX operation is reduced to a minimum and used only during extreme temperature peaks that may be experienced throughout the year. This results in asignificant reduction in electrical consumption possible even at full load (reaching the highest possible savings at partial loads).
The Liebert EFC Cost Function optimizes running costs (water and electricity), and according to the external dry bulb and heat load, selects the most convenient working mode (i.e. dry vs. wet). With the same logic, the Cost Function will also optimize the use of the optional Direct Expansion (DX) mode.
550 500 450 400 350 300 250 200 150 100
50
0
-20 -10 01020304050
600 550 500 450 400 350 300 250 200 150 100
50
0
-20 -10 01020304050
600 550 500 450 400 350 300 250 200 150 100
50
0
-20 -10 01020304050
Ambient Air Temperature
Ambient Air Temperature
London
45% dry mode 45% dry or wet mode
(cost function)
10% wet mode
Frankfurt
48% dry mode 36% dry or wet mode
(cost function)
16% wet mode
Istanbul
31% dry mode 33% dry or wet mode
(cost function) 34% wet mode
2% wet + DX mode
Technical Specifications
Model EFC 220 EFC 300 EFC 320 EFC 400 EFC 440
Net Cooling Capacity 1 kW 203 373 385 425 418
FANS 4+4 9+9 9+6 9+6 9+8
Maximum Airflow - Data Center Side
Max Wet Bulb - Adiabatic Effect Only
Max Wet Bulb - Adiabatic + DX Effect
Adiabaitic Capability High High+ Medium Medium High
DX Capability Ratio High Medium Medium High High+
2
m3/h 52.500 97.000 100.000 110.000 107.500
3
°C 21,2 21,8 16,9 19,5 20,4
3
°C 29,0 26,2 22,9 26,5 28,6
Dimensions
Length mm 4000 4500 3650 3650 4620
Depth mm 2300 2900 2900 3400 3400
Height mm 4050 4700 4700 4700 4600
1
Return air temperature: 36°C RH=25%; Supply air temperature: 24°C - considering maximum airflow condition below.
2
ESP = 0 Pa data center and process side.
3
Maximum wet bulb temperatures to provide the above net cooling capacities.
11
Liebert® EFC from 100 to 450 kW
Vertiv™ LIFE™ Services Remote Diagnostic and Preventive Monitoring
Vertiv's service program is designed to ensure that your critical power protection system is maintained in an optimum state of readiness at all times.
The Vertiv™ LIFE™ Services Remote Diagnostic and Preventive Monitoring provides early warning of UPS conditions and out of tolerances. This allows eective proactive maintenance, fast incident response and remote trouble shooting, giving customers complete security and peace of mind. With Vertiv LIFE Services you will benefit from:
Uptime Assurance
Constant monitoring of UPS parameters, thus maximizing the system’s availability.
First Time Fix Rate
Pro-active monitoring and data measuring ensure that when our
customer engineers are dispatched on-site, they arrive prepared for first time resolution.
Proactive Analysis
From Vertiv LIFE Services centers, our experts proactively analyze the data and trends of your equipment, to recommend a ctions to ensure their best performance.
Minimized Total Cost of Ownership of Your Equipment
The continuous monitoring of all relevant parameters in turn maximizes unit performance, reduces on-site maintenance and extends the life of your equipment.
Fast Incident Response
Vertiv LIFE Services allows for
immediate definition of the best course of action, as a result of the regular communication between your Liebert® EFC unit and our Vertiv LIFE Services centers.Reporting
You will receive a comprehensive report detailing the working order of your equipment and its operational performance.
Reporting
You will receive a comprehensive report detailing the working order of your equipment and its operational performance.
12
Customer Experience Center
Thermal Management
Vertiv’s Customer Experience Center located in Tognana (Padova - Italy), is specifically designed for customers to interact with Thermal Management data center technologies.
The center gives our customers the unique opportunity to witness pre-installation demonstrations, covering technical performance, interoperability and eiciency of Thermal Management solutions under a broad range of real field conditions.
Customers visiting the center may also benefit from a comprehensive consultation from our R&D, engineering and application specialists.
Evaporative Cooling Validation Area
Our Thermal Management Customer Experience Center features a dedicated area to test the state-of-the-art Liebert® EFC unit.
The scope of the Evaporative Cooling Validation Area is to provide customers, consultants and data center specialists with the most complete testing area to experience the capabilities of our evaporative technology at peak conditions.
Testing parameters include IT loads up to450 kW and an airflow of up to 120,000 m3 per hour, replicating typical peak conditions across the EMEA region, and an exceptional performance measurement accuracy within a +/- 5% maximum tolerance and a +/- 2% airflow tolerance. Airflow rate is also measured at the outlet side using calibrated intake nozzles in compliance with ANSI-AMCA 210/07 and ISO5801.
measurements are in line with the metrological laboratories’ standards (Accredia/EA/ILAC) and that our equipment precision level is also compliant with the European EN14511 standard.
Every customer visit is accompanied by a complete final report which includes
each and every tested parameter. Customers are guided through a first­hand experience with full transparency and flexibility enabling them to achieve the highest standards of technical excellence.
All our measuring tools are also periodically tested to adhere to the current international quality procedure ISO9001. This guarantees that all our
13
Liebert® EFC from 100 to 450 kW
Thermal Management Data Center Infrastructure for Small and Large Applications
Liebert® HPC
Wide range of high eiciency Freecooling Chillers from 40 kW to 1600 kW
Designed specifically for data center applications
and to work with Vertiv™ SmartAisle™
Premium energy eiciency version
Unique control capabilities with the Liebert® iCOM™
Control.
Liebert® HPM
Room cooling air conditioners available from 4 to 30 kW
Liebert® PDX Liebert® PCW
Available from 5-220 kW
Premium energy eiciency
Eurovent certified
performance
Unique control capabilities
with the Liebert® iCOM™
Control
Liebert EconoPhase™
available for the direct
expansion system and inverter driven compressors models.
Liebert® EFC
Indirect evaporative freecooling unit leveraging on data center know-how. Available from 100 to 450 kW
Unique control capabilities optimizing water and
energy costs
Substantial reductions and savings in terms of
electrical infrastructure.
14
14
Liebert® AFC
The Adiabatic Freecooling Chiller available from 500-1700 kW
Integrated adiabatic pad system
High freecooling capacity
100% compressor back up.
Service and Software
Solutions
Vertiv™ supports any application with
an extensive service oering including installation, start-up, commissioning, maintenance, replacements, 24/7 remote monitoring and diagnostics and much more.
Our remote diagnostics and preventive monitoring LIFE Service is adding value providing actual information to take decisions, as it allows early detection of anomalies and immediate reaction in case of alarms.
Vertiv™ SmartAisle™
Aisle containment
Provides highest energy eiciency
Works with any Liebert Thermal
Management unit.
Liebert® HPW
High performance wall mount outdoor package cooling system from 5 to 5 kW.
Liebert® HPS
Split system from 5 to 4 kW including an indoor evaporating unit and an outdoor compressorized condenser.
Liebert® HPF
Floor-mount package indoor cooling system from 5 to 5 kW.
15
Vertiv.com | Vertiv Infrastructure Limited, George Curl Way, Southampton, SO18 2RY, VAT Number: GB188146827
© 2020 Vertiv G roup Corp. All right s reserved. Ver tiv and the Vertiv log o are trademarks or re gistered tradema rks of Vertiv Group Cor p. All other names a nd logos referred to a re trade names, tra demarks or regist ered trademarks of th eir respective ow ners. While ever y precaut ion has been taken to en sure accuracy and c ompleteness h ere, Vertiv Group Cor p. assumes no res ponsibility, and d isclaims all liab ility, for damages re sulting from use of th is information or fo r any errors or omiss ions. Specif ications, rebate s and other promotio nal oers are subjec t to change at Vertiv ’s sole discretion up on notice.