Vermont Casting SR24SHK, SR18SHK, SR30SHK User Manual

Installation and Operating Instructions for Vented Gas Log Sets ­Standard Hearth Kits
Models: SR18SHK, SR24SHK, SR30SHK
Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplace
WARNING
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call
the fire department.
Please record your gas log’s model number for future reference here:
NOTE: This model # can be found on the box or the label attached to the back of the burner pan.
LISTED BY
LISTING NO. 1254
ATTENTION
Installation, service and repair of this appli­ance must be performed by a qualified in­staller, service agency, company or gas supplier experienced with this type of gas appliance.
Installer:
Read this instructions completely and carefully prior to beginning installation. After installation, leave these instructions with the owner.
Owner:
Read these instructions and follow the warnings. Save this manual for future reference.
Check local codes before installing this log set. In some areas of the country, gas log sets are restricted.
The installation and the provisions for combustion and ventilation air must conform with the National Fuel Gas Code, ANSI Z223.1.
WARNING
When used without fresh air, this unit may give off carbon monoxide, an odorless, poisonous gas. You must make adequate provision for accessibility and for combustion and ventilation of fresh air supply.
DANGER! CARBON MONOXIDE POISONING MAY LEAD TO DEATH
CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
www.majesticproducts.com • www.vermontcastings.co
3311956 12/04 Rev. 5
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read these directions thoroughly before installation. For assistance or additional information, consult your gas log dealer, qualified installer, service agency or gas supplier.
WARNING
Do not use this appliance or any part that has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
If not installed, operated and maintained in accordance with the manufacturer’s instruc­tions, this product could expose you to sub­stances in fuel or fuel combustion which are known to the state of California to cause cancer, birth defects or other reproductive harm.
WARNING
WARNING
A properly sized, unobstructed chimney will normally vent all fumes and products of combustion. Any odor or smoke detected in the room is an indication that the flue is not properly removing the combus­tion products. Turn off the gas supply valve immediately! The cause of the venting problem must be discovered and corrected before using this gas log set. Disregarding this warning can cause illness as well as soot damage to your fireplace, room and furnishings.
WARNING
Young children are not allowed to operate this unit and must be supervised when they are in the same room as the appliance.
Installation Precautions
Fireplace damper MUST be locked fully open when operating the gas log set. If the fireplace has glass doors, operate gas log set only with doors fully opened. The fireplace screen
must be in place when the appliance is operating and, unless other provisions for combustion air are provided, the screen shall have an opening(s) for introduction of combustion air.
The log set and its individual shut-off valve MUST be isolated from the gas supply piping system by closing its individual shut-off valve during any pressure testing of gas supply at test pressures equal to or less than 1/2 psig.
The log set and its individual shut-off valve MUST be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig.
Keep the gas log set clear and free from combustible materials, gasoline and other flammable vapors and liquids.
2
3311956
Pre-Installation Checklist Yes No
Are you burning Natural Gas? If you have Propane Gas, you need to purchase a factory authorized safety pilot kit (see below).
Is the gas supply inlet pressure correct? NG: Min. 5.5” w.c./Max. 14.0” w.c.
Does the firebox meet the minimum size dimensions below? Is your fireplace plumbed with gas on the right side (facing) of the fireplace?
If not, see Page 4. Is the gas supply line sized properly (Minimum 1/2” iron pipe)? Do you have a solid fuel (wood burning) fireplace with a vented flue? Do you have a manual gas supply valve installed at your fireplace? If not, a licensed
plumber, gas company technician or other qualified installer must install one. Have you checked local building codes? (Check with your local building department) Does your fireplace have a wire mesh screen in place?
CAUTION: If you answered “NO” to any item, or have any questions regarding your installation, please contact your dealer/distributor for assistance.
Minimum Clearances & Specifications
Natural Gas Units
Minimum Firebox Dimensions Minimum Gas Fuel Line
Set Input Width Flue Pressure
Size Btu/hr Back Front Depth Height Size Minimum Maximum
18” 65,000 16” 33” 15” 18” 51 sq.in. 5.5” w.c. 14.0” w.c. 24” 90,000 20” 36” 15” 18” 51 sq.in. 5.5” w.c. 14.0” w.c. 30” 90,000 27” 39” 15” 18” 51 sq.in. 5.5” w.c. 14.0” w.c.
NOTE: Use of a Pilot or LP Conversion Kit will add 3” to the minimum width requirements. Refer to the pilot kit’s installation instructions.
Propane (LP) Conversion
USE OF THIS SET WITH LP OR PROPANE FUEL REQUIRES THE INSTALALTIN OF ONE OF OUR FACTORY AUTHORIZED SAFETY PILOT KITS:
MODEL SPK P - Pilot Kit with Piezo Spark Ignition MODEL RVKRP - Millivolt PIlot Kit with Remote Control Capabilities
3311956
3
Tools Required
8” adjustable crescent wrench; pipe thread sealant compound or teflon tape; 12” pipe wrench or chan­nel lock pliers.
Gas Plumbed on Left Hand Side of Fireplace
NOTE: Your gas log set is assembled at the factory to be installed in a fireplace plumbed with the gas
on the right side (facing). If your fireplace is plumbed with the gas on the left side, you may remove the u-burner tube from the burner pan by removing the 3/4” knockout at the left back of the burner pan and reinstalling the u-burner tube 180 degrees from its original position. You may also run a flexible connec­tor (or as per local codes) along the back wall of the fireplace to bring your gas line to the right hand side. You can then place the set in front of the flexible connector.
Damper Stop Installation:
For Use with BR, BC, SR, SC, TF and TL Series CFM Specialty Home Products Fireplaces
This Damper Stop is designed to work on all CFM Specialty Home Products BR, BC, SR, SC, TF and TL series fireplaces. For all other fireplaces, refer to Page 6.
When installing a decorative gas appliance in a fireplace, some local codes require this Damper Stop to be used so the Damper will not close completely. To install the Damper Stop:
The Damper Locking Bracket is already installed on all BR, BC, SR, SC, TF and TL fireplaces. Locate the Damper Locking Bracket on the left side of the fireplace’s Combustion Dome. (Fig. 1)
With the Damper open, align the two slots on either side of the cut-out on the Damper Stop with the two small holes on the angled portion of the Damper Locking Bracket. Attach the Damper Stop with the Screws provided, as shown in Figure 2.
NOTE: Some of the early fireplace units may not have the holes in the end of the Damper Locking Bracket. If this is the case, use the Damper Stop as a template to drill two (2) 1/8” holes in the Damper Locking Bracket to mount the Damper Stop.
Damper Locking Bracket
Figure 1
Damper Locking Bracket
Damper Plate
DP100
Damper Stop Screw
Figure 3
4
Damper Stop
DP101
3311956
Damper Stop Installation:
For Use With All Other Fireplaces
The Damper Stop provided keeps your damper from accidentally closing during operation of your set. This Damper Stop must be installed onto
your Damper at all times. NOTE: The damper clamp is designed to hold the damper plate open 3 inches. However, the damper must be fully open when the log set is in operation.
Install the Damper Stop onto the edge of the damper plate. Attach by securing the bolt pro­vided to the damper plate with an adjustable wrench. (Fig. 3)
If the Damper Stop does not fit, drill a 1/4” hole into the damper plate and install an anchor bolt with nut, at a 90 degree angle, so that the damper plate will remain fully open.
Figure 3
Damper Plate
Damper Stop
DP104
The proper finished installation of the Damper Stop is shown in Figure 4. If the bolt fails to block the damper in an open position, the damper should be removed from the chimney.
To check your vent for proper drafting: Light a tightly rolled newspaper on one end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke is drawn
Chimney Clamp
Figure 4
Damper
DP103