PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
Installation and service must be
performed by a qualified installer, service
agency or the gas suppler.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier from
your neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER
APPLIANCE.
Stardance
Direct Vent/Natural Vent
Gas Heater
Model SDV30: 3900-3916, 39403956
This appliance may be installed in an after
market permanently located manufactured
(mobile) home where not prohibited by
local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit is
used.
Homeowner’s Installation
and Operating Manual
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
20007065 1/07 Rev. 13
Stardance Direct Vent/Natural Vent Gas Heater
Table of Contents
PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.
Thank you and congratulations on your purchase of a Vermont Castings stove.
IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these
instructions may result in a possible fire hazard and will void the warranty.
The Stardance Direct Vent/Natural Vent Room Heater, Model
Nos. 3900-3916, 3940-3956 is a vented gas appliance listed
to the ANSI standard Z21.88b-2002 and CSA-2.33b-2002 for
Vented Room Heaters, and CSA 2.17-M91, Gas-Fired Appli
ances For Use at High Altitudes.
The installation of the Stardance Direct Vent/Natural Vent Room
Heater must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 54
— latest edition and CSA B-149.1 Installation Code. (EXCEP
TION: Do not derate this appliance for altitude. Maintain the
manifold pressure at 3.5” w.c. for Natural Gas and 10.0” w.c.
for LP gas at maximum input.) Refer to Page 32 (RF only).
This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with
other gases unless a certified kit is used.
Installation and replacement of gas piping, gas utilization
equipment or accessories, and repair and servicing of
equipment shall be performed only by a qualified agency.
The term “qualified agency” means any individual, firm,
corporation, or company that either in person or through
a representative is engaged in and is responsible for (a)
installation or replacement of gas piping, or (b), the connection, installation, repair, or servicing of equipment, who
is experienced in such work, familiar with all precautions
required, and has complied with all the requirements of the
authority having jurisdiction.
The Stardance Direct Vent/Natural Vent Room Heater
should be inspected before use and at least annually by a
qualified service agency. It is imperative that control compartments, burners, and circulating air passageways of the
appliance be kept clean.
The Stardance Direct Vent/Natural Vent Room Heater and its
individual shut-off valve must be disconnected from the gas
supply piping during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.5 kPa).
The Stardance Direct Vent/Natural Vent Room Heater must
be isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure testing of
the gas supply piping system at test pressures equal to or less
than 1/2 psig.
‘Direct Vent’ describes a sealed combustion system in which
incoming outside air for combustion and outgoing exhaust enter
and exit through two separate concentric passages within the
same sealed vent system. The system does not use room air
to support combustion. The Direct Vent system permits the
gas appliance to be vented directly to the outside atmosphere
through the side of the house or vertically through the roof.
Conventional venting systems (Natural Vent) take air from the
room for combustion and vent the exhaust vertically through the
roof to the atmosphere.
This appliance is approved for bedroom installations in the U.S.
and Canada.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local
codes.
-
-
WARNING: Operation of this heater when not connected
to a properly installed and maintained venting system can
result in carbon monoxide (CO) poisoning and possible
death.
The Stardance Direct Vent/Natural Vent Room Heater, when
installed, must be electrically grounded in accordance with
local codes or, in the absence of local codes, with the National
Electrical Code ANSI/NFPA 70, (latest edition), or of the current
Canadian Electrical Code C22.1.
Due to high temperatures this appliance should be located
out of traffic and away from furniture and draperies.
WARNING: This appliance is hot while in operation. Keep
children, clothing, and furniture away. Contact may cause
burns or ignition of combustible materials.
Children and adults should be alerted to the hazards of
high surface temperatures and should stay away to avoid
burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the
appliance.
Clothing or other flammable materials should not be placed
on or near the appliance.
Any safety screen, glass or guard removed for servicing an
appliance must be replaced prior to operating the appliance.
The appliance area must be kept clear and free from combustible materials, gasoline, and other flammable vapors
and liquids.
The flow of combustion and ventilation air must not be
obstructed. The installation must include adequate accessibility and clearance for servicing and proper operation.
WARNING: Do not operate the Room Heater with the glass
panel removed, cracked or broken. Replacement of the
panel should be done by a licensed or qualified service
person.
Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
Do not burn wood, trash or any other material for which
this appliance was not designed. This appliance is designed to burn either natural gas or propane only.
This gas appliance must not be connected to a chimney
flue serving a separate solid-fuel burning appliance.
CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper and
dangerous operation.
Verify proper operation after servicing.
Proposition 65 Warning:
oil fired appliances, and the products of combustion of such fu
els, contain chemicals known to the State of California to cause
cancer, birth defects and other reproductive harm.
California Health & Safety Code Sec. 25249.6
* Aftermarket:
from the manufacturer.
Completion of sale, nor for purpose of resale,
Fuels used in gas, woodburning or
-
20007065
3
Stardance Direct Vent/Natural Vent Gas Heater
9"
(229 mm)
C
L
Valve
Inlet
26"
(680 mm)
25"
(635 mm)
14"
(355 mm)
3"
(76 mm)
C
L
Valve Inlet
Stardance Direct Vent / Natural Vent Dimensions
Attention
The Stardance stove is shipped from the factory as a Direct Vent Gas Heater. This heater
may be converted into a Natural Vent unit in the field. If a Natural Vent heater is desired,
the Vermont Castings Z31D00 FSDHAG Draft Hood must be directly installed to the top
of the unit according to the installation instructions. The Draft Hood Adapter is available
in the 7FSDHASK stove kit or as a separate item.
When the Stardance stove is converted to Natural Vent, it uses 4” vent pipe. For aesthetic purposes the CFM direct vent system may be used up to the ceiling.
4
20007065
Installation Requirements
A
B
E
C
D
The installation must conform with local codes or, in
the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5 inches w.c. for Natural
Gas, and 10 inches w.c. for Propane).
In Canada, installation must be in accordance with the
current CSA B-149.1 Installation Codes and/or local
codes.
The installation should be done by a qualified ser
vice person who is familiar with the building codes
and installation techniques appropriate for your
area to accomplish a safe and effective installation.
Your dealer or your local gas supplier will be able to
refer a qualified service person.
WARNING: Due to high temperatures, the HEATER
should be located out of traffic and away from furniture and draperies.
The surface of the Heater Is hot when it is in use.
Young children should be watched carefully when
they are in the same room when the Heater is in
use, and they should be taught to avoid the hot
surface. Keep any objects that can burn well away
from the Heater, and observe the recommended
clearances that follow.
Locating the Stove
In choosing a location for the stove, consider:
• The location of outside walls;
• Where additional heat is needed:
• Where family members gather most often;
• The vent system requirements.
NOTE: We do not recommend the use of wallpaper
next to this stove. Over time, radiant heat may cause
the wallpaper to shrink, or may adversely affect the
binders in the wallpaper adhesive.
Stardance Direct Vent/Natural Vent Gas Heater
-
ST207
Fig. 2 Possible stove locations.
Clearance Requirements
Minimum Clearances to Combustible
Materials
Measure side clearances as shown in Figures 3 and 4
from the outer edge of the cast iron stove top. Measure
rear clearances from the outermost surface of the steel
rear skirt.
The Stardance heater is approved for installation into
an alcove constructed of combustible materials to the
dimensions and clearances shown on the next page.
The same clearances apply in a standard parallel installation.
Warning:
• Always maintain required clearances
(air spaces) to nearby combustibles to prevent
fire hazard. Do not fill air spaces with insulation. All venting components must maintain a
1” (25 mm) clearance to combustible materials.
Maintain a 6” (150 mm) clearance when using a
single wall pipe.
• The gas appliance and vent system must be
vented directly to the outside of the building
and never be attached to a chimney serving a
separate solid fuel or gas-burning appliance.
Each direct vent appliance must use its own
separate vent system. Common vents are prohibited.
• Refer to the manufacturer’s instructions included with the venting system for complete
installation procedures.
Fig. 5 Dimensions and clearances to ceiling or alcove.
Hearth Requirements
The Stardance Heater must be installed on rigid floor
ing. When the heater is installed directly on any combustible surface other than wood flooring, a metal or
wood panel extending the full width and depth of the
unit must be used as the hearth. There are no other
hearth requirements.
-
6
20007065
Stardance Direct Vent/Natural Vent Gas Heater
20
19
18
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18 19 20
Vertical Run (in feet)
(Measured from the appliance flue collar to the top of the vent pipe.)
The installation of your Vermont Castings stove must
conform with local codes, or in the absence of local
codes, with the National Fuel Gas Code ANSI Z223.1/
NFPA 54 - latest edition, or CSA B149.1 Installation
code. (EXCEPTION: Do not derate this appliance for
altitude up to 4,500 feet (1,370m). Maintain the manifold pressure at 3.5” w.c. for Natural Gas and 10.0”
w.c. for LP Gas.
Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet
(1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA,
installations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having
jurisdiction.
In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause injury or property damage. Refer to this manual for
correct installation and operational procedures.
For assistance or additional information consult
a qualified installer, service agency, or the gas
supplier.
20007065
Gas Specifications
Gas Inlet and Manifold Pressures
Stardance Direct Vent / Natural Vent
Certified to:
ANSI Z21.88-2005 / CSA 2.33-2005
Vented Gas Fireplace Heaters
High Elevations
Horizontal Termination -
Direct Vent ONLY
The vent must rise vertically a minimum of 24” (610mm)
off the top of the unit, before the first elbow. The horizontal run may extend up to 20’ (6m) and include a
vertical rise of up to 40’ (12m). (Fig. 7) Horizontal
termination must also meet the criteria shown in Figures
9 through 11.
• Approved vent systems must terminate above and
including the heavy line in Figure 7.
• Two 45˚ elbows may be substituted for each single
90˚ elbow.
• With a rise between 2’ - 5’, one 90˚ or two 45˚ el
bows may be used.
May use up to
three 90° Elbows
One 90°
Elbow
Fig. 7 Horizontal vent termination window.
Unacceptable
Venting Configureation
-
ST134a
7
Stardance Direct Vent/Natural Vent Gas Heater
20
19
18
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Vertical Run (in feet)
(Measure from the appliance flue collar to the top of the vent pipe.)
A vertical vent system must terminate no less than 8’
(2.44m) and no more than 40’ (12m) above the appliance flue collar. A 2Z\v” restrictor plate (supplied) must
be used where specified in all vertically terminated vent
systems. (Fig. 8) NOTE: The restrictor plate supplied
with the vertical termination should be discarded. Install
restrictor plate supplied with stove directly at stove
outlet. A vertically terminated vent system must also
conform to the following criteria:
• No more than three 90˚ elbows may be used.
• Two 45˚ elbows may be substituted for one 90˚ el
bow. No more than six elbows may be used.
• Vent must rise a minimum of 2 feet before offset is
used.
• Termination height must conform to roof clearance
as specified in Figure 9.
All Vertical Terminations in this area
Require use of the
2¹⁄₄” Restrictor Plate*
Fig. 8 Vertical vent termination window.
*The restrictor Plate is used on Direct Vent Installations
Only.
8
Vertical Terminations
must be within this
area
Unacceptable Venting
Configuration
No Restrictor Plate
-
ST132a
Vent Termination Clearances
When planning the installation, consider the location
of the vent terminal and clearances. Some of the most
common clearances to keep in mind are shown in Figure 10.
Important: All vent clearances must be maintained.
Check your vent termination clearances against
Figures 9 through 11.
The vent should be placed so that people cannot be
burned by accidentally touching the vent surfaces when
the stove is operating.
The vent termination should be located where it cannot
be damaged by such things as automobile doors, lawn
mowers or snowblowers and it should be located away
from areas where it could become blocked by snow,
etc.
Some considerations are:
• Obstructions or impediments to venting.
• Nearby combustible materials that could come into
contact with combustion exhaust gases.
• Other nearby openings {within 12” (305mm)} through
which exhaust gas could reenter the building.
• All vegetation within 3’ ((76mm) that may interfere
with the draft.
Other factors that influence where the installation will
be sited include the location of outside walls, where
additional heat may be desired in the home, where the
family members gather most regularly, and perhaps
most importantly, the distance limitations of the venting
system.
IMPORTANT
Direct Vent Only
• The horizontal termination must not be recessed
into the exterior wall or siding.
• Horizontal vent runs must be level toward the vent
termination.
• Clearances around the vent termination must be
maintained.
• For installations using Simpson DuraVent pipe,
parallel installations with minimum wall clearance
have restricted access for connecting the Horizontal Vent Cap straps to the vent pipe. See the
maker’s instructions for recommended installation
procedures.
20007065
Stardance Direct Vent/Natural Vent Gas Heater
Vent Termination Clearances
Your stove is approved to be vented either through the
side wall, or vertical through the roof.
• CFM Corporation does not require any opening for
inspection of vent pipe.
• Only CFM Corporation and Simpson DuraVent vent
ing components specifically approved and labelled
for this stove may be used.
• Minimum clearances between vent pipes and com
bustible materials is one (1”) inch (25 mm), except
where stated otherwise.
• Venting terminals shall not be recessed into a wall or
siding.
• Horizontal venting must be installed on a level plane
without an inclining or declining slope.
-
There must not be any obstruction such as bushes,
garden sheds, fences, decks or utility buildings within
24” from the front of the termination hood.
Do not locate termination hood where excessive snow
-
or ice build up may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow
blowers, make sure snow is not directed towards vent
termination area.
Location of Vent Termination
It is imperative the vent termination be located observing the minimum clearances as shown on this page.
20007065
9
Stardance Direct Vent/Natural Vent Gas Heater
V
V
V
V
V
V
V
X
X
X
D
E
B
B
B
C
B
M
B
A
J
K
F
L
VENT TERMINATION AIR SUPPLY INLET
AREA WHERE TERMINAL IS NOT PERMITTED
H
I
Operable
Operable
Fixed
Closed
V
B
INSIDE
CORNER DETAIL
V
A
G
N
N
CFM145a
General Venting Information - Termination Location
Canadian Installations1 US Installations
2
A = Clearance above grade, veranda, porch, 12” (30cm) 12” (30cm)
deck, or balcony
B = Clearance to window or door that may be 6” (15cm) for appliances 6” (15cm) for appliances
opened < 10,000Btuh (3kW), 12” (30cm) < 10,000 Btuh (3kW), 9”
for appliances > 10,000 Btuh (3kW) and (23cm) for appliances > 10,000
< 100,000 Btuh (30kW), 36” (91cm) Btuh (3kW) and < 50,000 Btuh
for appliances > 100,000 Btuh (30kW) (15kW), 12” (30cm) for
appliances > 50,000 Btuh (15kW)
C = Clearance to permanently closed window 12” (305mm) recommended to 12” (305mm) recommended to
prevent window condensation prevent window condensation
D = Vertical clearance to ventilated soffit located
above the terminal within a horizontal 18” (458mm) 18” (458mm)
distance of 2’ (610mm) from the center
line of the terminal
E = Clearance to unventilated soffit 12” (305mm) 12” (305mm)
F = Clearance to outside corner see next page see next page
G = Clearance to inside corner (see next page) see next page see next page
H = Clearance to each inside of center line 3’ (91cm) within a height of 15’ (5m) 3’ (91cm) within a height of 15’
extended above meter/regulator assembly above the meter/regulator assembly (5m) above the meter/regulator
assy
I = Clearance to service regulator vent outlet 3’ (91cm) 3’ (91cm)
J = Clearance to nonmechanical air supply inlet 6” (15cm) for appliances < 10,000 6” (15cm) for appliances
to building or the combustion air inlet to any Btuh (3kW), 12” (30cm) for < 10,000 Btuh (3kW), 9”
other appliances appliances > 10,000 Btuh (3kW) and (23cm) for appliances > 10,000
< 100,000 Btuh (30kW), 36” (91cm) Btuh (3kW) and < 50,000 Btuh
for appliances > 100,000 Btuh (30kW) (15kW), 12” (30cm) for
appliances > 50,000 Btuh (15kW)
K = Clearance to a mechanical air supply inlet 6’ (1.83m) 3’ (91cm) above if within 10
feet (3m) horizontally
L = Clearance above paved sidewalk or paved 7’ (2.13m)† 7’ (2.13m)†
driveway located on public property
M = Clearance under veranda, porch, deck or 12” (30cm)‡ 12” (30cm)‡
balcony
N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof
surface, and any other obstruction within a horizontal distance of 18” (450mm).
1 In accordance with the current CSA-B149 Installation Codes
2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes
† A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor:
NOTE: 1. Local codes or regulations may require different clearances.
2. The special venting system used on Direct Vent units are certified as part of the appliance, with clearances tested and approved by the listing agency.
3. CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not
meet these requirements.
Fig. 9 Vent termination clearances.
10
20007065
Venting Runs
Horizontal Run (in feet)
Vertical Run (in feet)
(Measured from top of the unit before any elbow)
A: Vertical installations up to 36 feet (12m) in
height. Up to an 18 ft. horizontal vent run can be
installed within the vent system using a
maximum of two 90-degree elbows or four
45-degree elbows.
B: Vertical installations up to 36 feet (12m) in
height. Up to a 24 ft. horizontal vent run can be
installed within the vent system using a
maximum of two 45-degree elbows.
(Ratio = 2/3, Hor./Vert.)
NOTE: When venting staight vertical, without any
elbow, a minimum of 8 ft. vertical is required
off the top of the stove.
Outside Corner
Inside Corner
Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors.
G =
Combustible
6" (152 mm)
Noncombustible
2" (51 mm)
F =
Combustible
6" (152 mm)
Noncombustible
2" (51 mm)
G
Balcony with no side wall
M =
Combustible &
Noncombustible
12" (305 mm)
M
Balcony with perpendicular side wall
M = 24" (610 mm)
P = 20” (508 mm)
M
F
Alcove Applications*
C
D
C
E
V
V
Combustible &
Noncombustible
V
V
V
E = Min. 6” (152 mm) for
non-vinyl sidewalls
Min. 12” (305 mm) for
vinyl sidewalls
O = 8’ (2.4 m) Min.
O
P
*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions
specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All
mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All
gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap.
Fig. 10 Termination clearances.
Stardance Direct Vent/Natural Vent Gas Heater
No.
of Caps D
1 3’ (.9 mm) 2 x D
2 6’ (1.8 m) 1 x D
3 9’ (2.7 m) 2/3 x D
4 12’ (3.7 m) 1/2 x D
NOTE: When using the FSDHAG, the restrictor plate
supplied with the stove is not used.
11
Stardance Direct Vent/Natural Vent Gas Heater
Venting Requirements and Options -
Direct Vent ONLY
Approved Vent System Components
The Stardance Heater must be vented to the outdoors
through an adjacent exterior wall or through the roof.
The venting system must be comprised of the appropriate listed venting components specified on this page.
These parts are available from DuraVent Corporation or
your Vermont Castings Dealer.
See Figure 4 for dimensions relevant to the standard
minimum-vent kits.
All DuraVent Straight vent pipe sections have a net
length 1¹⁄₂” (37mm) less than the nominal dimension;
i.e., a 6” (152mm) Straight pipe section has an effective
length of 4¹⁄₂” (115mm).
CFM Vent Components
The following kits are available to meet the needs of
most installations. All pipe has a 7” outer diameter and
includes a 4” diameter inner section. A (CG) designation indicates the part is finished in Charcoal Gray paint.
Consult your dealer about other vent parts that may be
appropriate to complete the installation.
Vent system from the top of the draft hood adapter to
the ceiling.
12
20007065
Stardance Direct Vent/Natural Vent Gas Heater
Install the Optional Fan
If you are installing the optional convection Fan Kit
#2767 (FK26), continue here. If you are not installing a
Fan Kit, go to Page 14, Venting System Assembly.
1. The fan kit includes a Blower Assembly and a Rheostat Assembly, connected by a cable. (Fig. 12) The
Blower Assembly mounts to the bottom rear of the
stove, and the Rheostat mounts to the valve bracket
to the left of the valve. The assembly includes a
‘snapstat’ which automatically turns the fan On (or
Off) above (or below) approximately 109˚. The Rheostat also provides a range of fan speed settings from
Off (which overrides the snapstat function) to High.
Unpack and inspect the Blower assembly. Confirm
the fan spins freely.
WARNING
This appliance is equipped with a three-prong
(grounded) plug for your protection against shock
hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.
Not Used on RF Models
Not Used on
Stardance
Snapstat Bracket
Snapstat/
Extension
Assembly
4. The rheostat control switch attaches to the left side
of the valve bracket at the front of the stove. (Fig. 15)
• Remove retaining nut from shaft of rheostat. (if
preinstalled)
• Insert the rheostat through the hole in the back
of the left side of the valve bracket, aligning the
locator pin with the smaller hole in that bracket.
• Thread the retaining nut onto the shaft of the
rheostat, tightening with a wrench. Do not overtighten.
• Attach the control knob to the rheostat shaft.
• Use the wire tie to secure the fan and rheostat
wire harnesses together.
Rear Skirt
Sheet Metal
Screws
Rear Skirt
Insert
Fig. 13 Remove rear skirt insert.
ST313
Rheostat
Assembly
Not Used
on RF
Models
Blower
Assembly
ST473
Fig. 12 Fan kit components.
Connect to PC Board on
RF Models Only
2. Remove the rear skirt insert panel at the bottom of
the Rear Skirt (Fig. 13) and fasten the blower assembly to the firebox back with the two Phillips pan-head
bolts originally installed in the firebox back. (‘1’, Fig.
14)
NOTE: Steps 3 and 4 do not apply when the RF
valve is used. After attaching blower assembly to the
firebox, run the spliced female leads to the front of
the stove and attach to back of RF valve. (Page 28,
Fig. 51)
3. Attach the snapstat assembly to the snapstat bracket
with two sheet-metal screws. (‘2’, Fig. 15) Attach the
snapstat bracket to the stove with a hex-head bolt
passing through the bracket and into the stove base.
(‘3’, Fig. 14)
Star Washer
Sheet Metal Screws
Phillips
Pan Head
Bolts
Star
Washer
NOTE: Shown
without shell for
clarification
Fig. 14 Attach the fan assembly and the snapstat.
Fig. 15 Attach the fan rheostat.
1
Rheostat Retaining
Collar
Rheostat Knob
2
3
Snapstat
1/4” - 20
Hex Bolt
Snapstat
Bracket
ST314
ST347a
20007065
13
Stardance Direct Vent/Natural Vent Gas Heater
CEMENT
CEMENT
Venting System Assemlby - Direct Vent
General Information
The Stardance is approved for installation only with the
vent components listed on Page 12. Follow the vent
component instructions exactly.
For U.S. installations: The venting system must conform with local codes and/or the current National Fuel
Gas Code, ANSI Z223.1/NFPA 54.
For Canadian installations: The venting system must
conform to the current CSA B149.1 installation code.
Install the Vent Adapter Pipe
(CFM Corporation Vent Components)
1. Install the Restrictor Plate. Consult the ‘Vent Run
Specifications’ on Page 8 to determine whether the
restrictor plate is needed. If so, put the restrictor
plate in place within the inner flue collar as shown in
Figure 16.
First Section of Vent
Pipe
#8 x 1/2” Sheet
Metal Screws
3” Inner
Starter PIpe
ST211
Fig. 17 Connect the inner starter with the next section of inner vent pipe.
ST210
Fig. 16 Install the restrictor plate only if required for the venting configuraiotn. Refer to Page 8.
2. Attach Inner Starter Pipe, (found in with the logset), to the next section of inner pipe.
• Run a bead of sealant about 1/2” from the upper
end of the Inner starter pipe and join the two sections together.
• Drill three pilot holes into the Inner Starter and
secure the assembly with three sheet metal screws.
(Fig. 17)
3. Dry fit the Inner Pipe assembly to the stove for
the purpose of determining the center line of the
pipe on the wall.
• Side Wall Terminations: Dry fit the outer elbow
with the vertical outer vent and confirm the centerline
alignment with the wall thimble opening.
4. Attach the Inner Vent Assembly to the stove.
• Run a bead of sealant around the bottom end of
the starter pipe and attach the assembly to the stove
using three 1/4-20 x 3/8” Phillips screws provided in
the parts bag. (Fig. 18)
ST212
Fig. 18 Attach inner assembly to flue collar.
5. Install the Outer Adapter Pipe. Apply a 1/4” bead
of cement around the inside wall of the pipe, about
1” from the end. Insert the pipe over the stove flue
collar, keeping the vertical seam oriented to the back
of the stove. Also, be sure to align holes on the pipe
with the holes on the flue collar of the firebox. Fasten
the pipe to the holes in the flue collar with the #12 x
1/2” sheet metal screws provided. (Fig. 19)
ST213
Fig. 19 Fasten outer pipe with #12 x 1/2” sheet metal screw.
14
20007065
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.