SAFETY INFORMATION
PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE.
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas suppler.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier from
your neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
DO NOT STORE OR USE GASO­LINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
Stardance Direct Vent/Natural Vent Gas Heater
Model SDV30: 3900-3916, 3940­3956
This appliance may be installed in an after market permanently located manufactured (mobile) home where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases unless a certified kit is used.
Homeowner’s Installation
and Operating Manual
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
20007065 1/07 Rev. 13
Stardance Direct Vent/Natural Vent Gas Heater
Table of Contents
PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.
Thank you and congratulations on your purchase of a Vermont Castings stove.
IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these
instructions may result in a possible fire hazard and will void the warranty.
Installation & Operating Instructions .............................................................................................3
Stove Dimensions ................................................................................................................4
Installation Requirements .....................................................................................................
Locating the Stove ...............................................................................................................5
Clearance Requirements .....................................................................................................5
Parallel & Corner Installation ................................................................................................
Wall and Ceiling Clearances ................................................................................................6
Hearth Requirements ...........................................................................................................
Gas Specifications................................................................................................................7
Gas Inlet and Manifold Pressures ........................................................................................7
Horizontal & Termination - Direct Vent ONLY .......................................................................
Vertical Termination - Direct Vent ONLY ...............................................................................8
Vent Termination Clearances ...............................................................................................
General Venting Information - Termination Location ..........................................................10
Termination Clearances .....................................................................................................11
Venting Requirements - Natural Vent ONLY ......................................................................11
Venting Requirements and Options - Direct Vent ONLY ....................................................
Assembly Procedures
Install the Optional Fan ......................................................................................................13
Venting System Assembly - Direct Vent .............................................................................14
Install Vent Adapter Pipe ....................................................................................................
Side Wall Termination Assembly ........................................................................................15
Vent Termination Below Grade ...........................................................................................
Vertical (Through the Roof) Vent Assembly .......................................................................17
Venting System Assembly - Natural Vent ...........................................................................18
Install the Vent Pipe ...........................................................................................................
Install the Log Set ..............................................................................................................19
Connect Gas Supply Line ..................................................................................................
Burner Information..............................................................................................................20
Air Shutter Adjustment & Instructions .................................................................................20
Complete the Assembly .....................................................................................................
Install ON/OFF Switch ........................................................................................................21
Thermostat Connection (Optional) .....................................................................................
Install the Front Plate .........................................................................................................22
Operation
Your First Fire .....................................................................................................................
Pilot and Burner Information ..............................................................................................23
Flame & Temperature Adjustment / Flame Characteristics ................................................
Lighting and Operating Instructions ...................................................................................24
Troubleshooting - Honeywell #8420 Gas Control System ..................................................25
Instructions for RF Comfort Control Valve ..........................................................................
Fuel Conversion Instructions ..............................................................................................30
Maintenance
Annual System Inspection ..................................................................................................33
Logset and Burner/Cleaning and Inspection ......................................................................33
Care of Cast Iron ................................................................................................................
Cleaning the Glass .............................................................................................................33
Glass Replacement ............................................................................................................
Gasket Replacement ..........................................................................................................34
Inspect the Vent System Annually ......................................................................................34
Check the Gas Flame Regularly ........................................................................................
Stove Disassembly .............................................................................................................34
Wiring Diagram ...................................................................................................................
Replacement Parts .........................................................................................................................36
Optional Accessories ....................................................................................................................39
Warranty
2
Energuide ........................................................................................................................................44
..........................................................................................................................................42
5
6
6
7
8
12
14
17
19
19
21
22
23
23
26
33
33
34
35
20007065
Stardance Direct Vent/Natural Vent Gas Heater
General Information
The Stardance Direct Vent/Natural Vent Room Heater, Model Nos. 3900-3916, 3940-3956 is a vented gas appliance listed to the ANSI standard Z21.88b-2002 and CSA-2.33b-2002 for Vented Room Heaters, and CSA 2.17-M91, Gas-Fired Appli ances For Use at High Altitudes.
The installation of the Stardance Direct Vent/Natural Vent Room Heater must conform with local codes, or in the absence of lo­cal codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest edition and CSA B-149.1 Installation Code. (EXCEP TION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5” w.c. for Natural Gas and 10.0” w.c. for LP gas at maximum input.) Refer to Page 32 (RF only).
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.
Installation and replacement of gas piping, gas utilization equipment or accessories, and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) installation or replacement of gas piping, or (b), the con­nection, installation, repair, or servicing of equipment, who is experienced in such work, familiar with all precautions required, and has complied with all the requirements of the authority having jurisdiction.
The Stardance Direct Vent/Natural Vent Room Heater should be inspected before use and at least annually by a qualified service agency. It is imperative that control com­partments, burners, and circulating air passageways of the appliance be kept clean.
The Stardance Direct Vent/Natural Vent Room Heater and its individual shut-off valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The Stardance Direct Vent/Natural Vent Room Heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
‘Direct Vent’ describes a sealed combustion system in which incoming outside air for combustion and outgoing exhaust enter and exit through two separate concentric passages within the same sealed vent system. The system does not use room air to support combustion. The Direct Vent system permits the gas appliance to be vented directly to the outside atmosphere through the side of the house or vertically through the roof. Conventional venting systems (Natural Vent) take air from the room for combustion and vent the exhaust vertically through the roof to the atmosphere.
This appliance is approved for bedroom installations in the U.S. and Canada.
This appliance may be installed in an aftermarket* manufac­tured (mobile) home, where not prohibited by state or local codes.
-
-
WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.
The Stardance Direct Vent/Natural Vent Room Heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, (latest edition), or of the current Canadian Electrical Code C22.1.
Due to high temperatures this appliance should be located out of traffic and away from furniture and draperies.
WARNING: This appliance is hot while in operation. Keep children, clothing, and furniture away. Contact may cause burns or ignition of combustible materials.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be care­fully supervised when they are in the same room as the appliance.
Clothing or other flammable materials should not be placed on or near the appliance.
Any safety screen, glass or guard removed for servicing an appliance must be replaced prior to operating the appli­ance.
The appliance area must be kept clear and free from com­bustible materials, gasoline, and other flammable vapors and liquids.
The flow of combustion and ventilation air must not be obstructed. The installation must include adequate acces­sibility and clearance for servicing and proper operation.
WARNING: Do not operate the Room Heater with the glass panel removed, cracked or broken. Replacement of the panel should be done by a licensed or qualified service person.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Do not burn wood, trash or any other material for which this appliance was not designed. This appliance is de­signed to burn either natural gas or propane only.
This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing. Proposition 65 Warning:
oil fired appliances, and the products of combustion of such fu els, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.
California Health & Safety Code Sec. 25249.6
* Aftermarket:
from the manufacturer.
Completion of sale, nor for purpose of resale,
Fuels used in gas, woodburning or
-
20007065
3
Stardance Direct Vent/Natural Vent Gas Heater
9"
(229 mm)
C
L
Valve Inlet
26"
(680 mm)
25"
(635 mm)
14"
(355 mm)
3"
(76 mm)
C
L
Valve Inlet
Stardance Direct Vent / Natural Vent Dimensions
Attention
The Stardance stove is shipped from the factory as a Direct Vent Gas Heater. This heater may be converted into a Natural Vent unit in the field. If a Natural Vent heater is desired, the Vermont Castings Z31D00 FSDHAG Draft Hood must be directly installed to the top of the unit according to the installation instructions. The Draft Hood Adapter is available in the 7FSDHASK stove kit or as a separate item.
When the Stardance stove is converted to Natural Vent, it uses 4” vent pipe. For aes­thetic purposes the CFM direct vent system may be used up to the ceiling.
4
20007065
Installation Requirements
A
B
E
C
D
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEP­TION: Do not derate this appliance for altitude. Main­tain the manifold pressure at 3.5 inches w.c. for Natural Gas, and 10 inches w.c. for Propane).
In Canada, installation must be in accordance with the current CSA B-149.1 Installation Codes and/or local codes.
The installation should be done by a qualified ser vice person who is familiar with the building codes and installation techniques appropriate for your area to accomplish a safe and effective installation.
Your dealer or your local gas supplier will be able to refer a qualified service person.
WARNING: Due to high temperatures, the HEATER should be located out of traffic and away from fur­niture and draperies.
The surface of the Heater Is hot when it is in use. Young children should be watched carefully when they are in the same room when the Heater is in use, and they should be taught to avoid the hot surface. Keep any objects that can burn well away from the Heater, and observe the recommended clearances that follow.
Locating the Stove
In choosing a location for the stove, consider:
• The location of outside walls;
• Where additional heat is needed:
• Where family members gather most often;
• The vent system requirements. NOTE: We do not recommend the use of wallpaper
next to this stove. Over time, radiant heat may cause the wallpaper to shrink, or may adversely affect the binders in the wallpaper adhesive.
Stardance Direct Vent/Natural Vent Gas Heater
-
ST207
Fig. 2 Possible stove locations.
Clearance Requirements
Minimum Clearances to Combustible
Materials
Measure side clearances as shown in Figures 3 and 4 from the outer edge of the cast iron stove top. Measure rear clearances from the outermost surface of the steel rear skirt.
The Stardance heater is approved for installation into an alcove constructed of combustible materials to the dimensions and clearances shown on the next page.
The same clearances apply in a standard parallel instal­lation.
Warning:
• Always maintain required clearances (air spaces) to nearby combustibles to prevent fire hazard. Do not fill air spaces with insula­tion. All venting components must maintain a 1” (25 mm) clearance to combustible materials. Maintain a 6” (150 mm) clearance when using a single wall pipe.
• The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent appliance must use its own separate vent system. Common vents are pro­hibited.
• Refer to the manufacturer’s instructions in­cluded with the venting system for complete installation procedures.
20007065
5
Stardance Direct Vent/Natural Vent Gas Heater
C
L
C
L
B
D
C
A
A
A
B
B
A
A
C
D
B
Parallel Installation: Minimum Clearance
and Flue Centerline, Direct Vent and
Natural Vent
ST128b
Stove Clearances: A: 4” (102 mm) B: 4” (102 mm) Pipe Centerlines: C: 15¹⁄₂” (395 mm) D: 9” (229 mm)
Fig. 3 Parallel installation, minimum back and side clear­ances, and flue centerlines.
Wall Centerline from Floor
Direct Vent Only
ST131b
Effective Minimum Wall Thimble 56” (1480 mm) (CFM Pipe) Centerline 52” (1378 mm) (Simpson Duravent Pipe)
Fig. 5 Minimum wall thimble centerline.
Wall and Ceiling Clearances
Corner Installation:
Minimum Clearance and Flue Centerline,
Direct Vent and Natural Vent
ST101b
A: Rear Wall 4” (102 mm) B: Min. Clearance 45¹⁄₄” (1154 mm)* C: Min. Alcove Height 72” (1830 mm)
Stove Clearance: A: 4” (102 mm) Pipe Centerline: B: 14¹⁄₂” (370 mm)
Fig. 4 Corner installation, minimum corner clearance and flue centerline.
ST129b
D: Max. Alcove Depth 48” (1220 mm) Sidewall Clearance 4” (102 mm)
Fig. 5 Dimensions and clearances to ceiling or alcove.
Hearth Requirements
The Stardance Heater must be installed on rigid floor ing. When the heater is installed directly on any com­bustible surface other than wood flooring, a metal or wood panel extending the full width and depth of the unit must be used as the hearth. There are no other hearth requirements.
-
6
20007065
Stardance Direct Vent/Natural Vent Gas Heater
20
19
18
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18 19 20
Vertical Run (in feet)
(Measured from the appliance flue collar to the top of the vent pipe.)
Horizontal Run (in feet)
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
ST134a FDV28 Horizontal vent run 12/3/99 djt areas modified 1/11/00 djt
Max. Min.
Input Input Model Fuel Gas Control BTU/h BTU/h
SDV30RN Nat Millivolt 28,000 20,000 SDV30RP Prop Millivolt 28,000 19,000 SDV30RFN Nat Comfort Control 28,000 20,000 SDV30RFP Prop Comfort Control 28,000 19,500
Weight: Fully assembled; 202 lbs.
Natural LP (Propane) Inlet Minimum 5.5” w.c. 11.0” w.c. Inlet Maximum 14.0” w.c. 14.0” w.c. Manifold Pressure 3.5” w.c. 10” w.c.
The installation of your Vermont Castings stove must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/ NFPA 54 - latest edition, or CSA B149.1 Installation code. (EXCEPTION: Do not derate this appliance for altitude up to 4,500 feet (1,370m). Maintain the mani­fold pressure at 3.5” w.c. for Natural Gas and 10.0” w.c. for LP Gas.
Input ratings are shown in BTU per hour and are cer­tified without deration for elevations up to 4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local au­thorities having jurisdiction for installations at eleva­tions above 4,500 feet (1,370m).
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause in­jury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.
20007065
Gas Specifications
Gas Inlet and Manifold Pressures
Stardance Direct Vent / Natural Vent
Certified to:
ANSI Z21.88-2005 / CSA 2.33-2005
Vented Gas Fireplace Heaters
High Elevations
Horizontal Termination -
Direct Vent ONLY
The vent must rise vertically a minimum of 24” (610mm) off the top of the unit, before the first elbow. The hori­zontal run may extend up to 20’ (6m) and include a vertical rise of up to 40’ (12m). (Fig. 7) Horizontal termination must also meet the criteria shown in Figures 9 through 11.
• Approved vent systems must terminate above and including the heavy line in Figure 7.
• Two 45˚ elbows may be substituted for each single 90˚ elbow.
• With a rise between 2’ - 5’, one 90˚ or two 45˚ el bows may be used.
May use up to
three 90° Elbows
One 90°
Elbow
Fig. 7 Horizontal vent termination window.
Unacceptable
Venting Configureation
-
ST134a
7
Stardance Direct Vent/Natural Vent Gas Heater
20
19
18
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Vertical Run (in feet)
(Measure from the appliance flue collar to the top of the vent pipe.)
Horizontal Run (in feet)
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
ST132a FDV28 Vertical vent run 12/3/99 djt area modified 1/11/00 djt
Vertical Termination - Direct Vent ONLY
A vertical vent system must terminate no less than 8’ (2.44m) and no more than 40’ (12m) above the appli­ance flue collar. A 2Z\v” restrictor plate (supplied) must be used where specified in all vertically terminated vent systems. (Fig. 8) NOTE: The restrictor plate supplied with the vertical termination should be discarded. Install restrictor plate supplied with stove directly at stove outlet. A vertically terminated vent system must also conform to the following criteria:
• No more than three 90˚ elbows may be used.
• Two 45˚ elbows may be substituted for one 90˚ el bow. No more than six elbows may be used.
• Vent must rise a minimum of 2 feet before offset is used.
• Termination height must conform to roof clearance as specified in Figure 9.
All Vertical Termina­tions in this area Require use of the 2¹⁄₄” Restrictor Plate*
Fig. 8 Vertical vent termination window. *The restrictor Plate is used on Direct Vent Installations Only.
8
Vertical Terminations
must be within this
area
Unacceptable Venting
Configuration
No Restrictor Plate
-
ST132a
Vent Termination Clearances
When planning the installation, consider the location of the vent terminal and clearances. Some of the most common clearances to keep in mind are shown in Fig­ure 10.
Important: All vent clearances must be maintained. Check your vent termination clearances against Figures 9 through 11.
The vent should be placed so that people cannot be burned by accidentally touching the vent surfaces when the stove is operating.
The vent termination should be located where it cannot be damaged by such things as automobile doors, lawn mowers or snowblowers and it should be located away from areas where it could become blocked by snow, etc.
Some considerations are:
• Obstructions or impediments to venting.
• Nearby combustible materials that could come into contact with combustion exhaust gases.
• Other nearby openings {within 12” (305mm)} through which exhaust gas could reenter the building.
• All vegetation within 3’ ((76mm) that may interfere with the draft.
Other factors that influence where the installation will be sited include the location of outside walls, where additional heat may be desired in the home, where the family members gather most regularly, and perhaps most importantly, the distance limitations of the venting system.
IMPORTANT Direct Vent Only
• The horizontal termination must not be recessed into the exterior wall or siding.
• Horizontal vent runs must be level toward the vent termination.
• Clearances around the vent termination must be maintained.
• For installations using Simpson DuraVent pipe, parallel installations with minimum wall clearance have restricted access for connecting the Hori­zontal Vent Cap straps to the vent pipe. See the maker’s instructions for recommended installation procedures.
20007065
Stardance Direct Vent/Natural Vent Gas Heater
Vent Termination Clearances
Your stove is approved to be vented either through the side wall, or vertical through the roof.
• CFM Corporation does not require any opening for inspection of vent pipe.
• Only CFM Corporation and Simpson DuraVent vent ing components specifically approved and labelled for this stove may be used.
• Minimum clearances between vent pipes and com bustible materials is one (1”) inch (25 mm), except where stated otherwise.
• Venting terminals shall not be recessed into a wall or siding.
• Horizontal venting must be installed on a level plane without an inclining or declining slope.
-
There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24” from the front of the termination hood.
Do not locate termination hood where excessive snow
-
or ice build up may occur. Be sure to check vent termi­nation area after snow falls, and clear to prevent ac­cidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.
Location of Vent Termination
It is imperative the vent termination be located observ­ing the minimum clearances as shown on this page.
20007065
9
Stardance Direct Vent/Natural Vent Gas Heater
V
V
V
V
V
V
V
X
X
X
D
E
B
B
B
C
B
M
B
A
J
K
F
L
VENT TERMINATION AIR SUPPLY INLET
AREA WHERE TERMINAL IS NOT PERMITTED
H
I


Operable
Operable
Fixed
Closed
V
B
INSIDE
CORNER DETAIL
V
A
G
N
N
CFM145a
General Venting Information - Termination Location
Canadian Installations1 US Installations
2
A = Clearance above grade, veranda, porch, 12” (30cm) 12” (30cm) deck, or balcony
B = Clearance to window or door that may be 6” (15cm) for appliances 6” (15cm) for appliances opened < 10,000Btuh (3kW), 12” (30cm) < 10,000 Btuh (3kW), 9” for appliances > 10,000 Btuh (3kW) and (23cm) for appliances > 10,000 < 100,000 Btuh (30kW), 36” (91cm) Btuh (3kW) and < 50,000 Btuh for appliances > 100,000 Btuh (30kW) (15kW), 12” (30cm) for appliances > 50,000 Btuh (15kW)
C = Clearance to permanently closed window 12” (305mm) recommended to 12” (305mm) recommended to prevent window condensation prevent window condensation
D = Vertical clearance to ventilated soffit located above the terminal within a horizontal 18” (458mm) 18” (458mm) distance of 2’ (610mm) from the center line of the terminal
E = Clearance to unventilated soffit 12” (305mm) 12” (305mm) F = Clearance to outside corner see next page see next page G = Clearance to inside corner (see next page) see next page see next page H = Clearance to each inside of center line 3’ (91cm) within a height of 15’ (5m) 3’ (91cm) within a height of 15’
extended above meter/regulator assembly above the meter/regulator assembly (5m) above the meter/regulator assy
I = Clearance to service regulator vent outlet 3’ (91cm) 3’ (91cm) J = Clearance to nonmechanical air supply inlet 6” (15cm) for appliances < 10,000 6” (15cm) for appliances
to building or the combustion air inlet to any Btuh (3kW), 12” (30cm) for < 10,000 Btuh (3kW), 9” other appliances appliances > 10,000 Btuh (3kW) and (23cm) for appliances > 10,000 < 100,000 Btuh (30kW), 36” (91cm) Btuh (3kW) and < 50,000 Btuh for appliances > 100,000 Btuh (30kW) (15kW), 12” (30cm) for appliances > 50,000 Btuh (15kW)
K = Clearance to a mechanical air supply inlet 6’ (1.83m) 3’ (91cm) above if within 10 feet (3m) horizontally
L = Clearance above paved sidewalk or paved 7’ (2.13m)† 7’ (2.13m)† driveway located on public property
M = Clearance under veranda, porch, deck or 12” (30cm)‡ 12” (30cm)‡ balcony
N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450mm).
1 In accordance with the current CSA-B149 Installation Codes 2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes † A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings ‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: NOTE: 1. Local codes or regulations may require different clearances.
2. The special venting system used on Direct Vent units are certified as part of the appliance, with clearances tested and approved by the listing agency.
3. CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.
Fig. 9 Vent termination clearances.
10
20007065
Venting Runs
Horizontal Run (in feet)
Vertical Run (in feet)
(Measured from top of the unit before any elbow)
A: Vertical installations up to 36 feet (12m) in height. Up to an 18 ft. horizontal vent run can be installed within the vent system using a maximum of two 90-degree elbows or four 45-degree elbows.
B: Vertical installations up to 36 feet (12m) in height. Up to a 24 ft. horizontal vent run can be installed within the vent system using a maximum of two 45-degree elbows. (Ratio = 2/3, Hor./Vert.)
= Acceptable venting configuration
= Unacceptable venting configuration















A
B
NOTE: When venting staight vertical, without any elbow, a minimum of 8 ft. vertical is required off the top of the stove.
Outside Corner
Inside Corner
Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors.
G =
Combustible 6" (152 mm)
Noncombustible 2" (51 mm)
F =
Combustible 6" (152 mm)
Noncombustible 2" (51 mm)
G
Balcony ­with no side wall
M =
Combustible & Noncombustible 12" (305 mm)
M
Balcony ­with perpendicular side wall
M = 24" (610 mm) P = 20” (508 mm)
M
F
Alcove Applications*
C
D
C
E
V
V
Combustible & Noncombustible
V
V
V
E = Min. 6” (152 mm) for
non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls
O = 8’ (2.4 m) Min.
O
P
*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap.
Fig. 10 Termination clearances.
Stardance Direct Vent/Natural Vent Gas Heater
No.
of Caps D 1 3’ (.9 mm) 2 x D 2 6’ (1.8 m) 1 x D 3 9’ (2.7 m) 2/3 x D 4 12’ (3.7 m) 1/2 x D
D
= # of Termination caps x 3
Min.
C
= (2 / # termination caps) x D
Max.
C
Min.
Max.
Actual
Actual
Actual
Actual
Actual
584-15
Venting Requirements - Natural Vent Only
Fig. 11 Vent termination window - Natural Vent ONLY.
20007065
NOTE: When using the FSDHAG, the restrictor plate supplied with the stove is not used.
11
Stardance Direct Vent/Natural Vent Gas Heater
Venting Requirements and Options -
Direct Vent ONLY
Approved Vent System Components
The Stardance Heater must be vented to the outdoors through an adjacent exterior wall or through the roof. The venting system must be comprised of the appropri­ate listed venting components specified on this page. These parts are available from DuraVent Corporation or your Vermont Castings Dealer.
See Figure 4 for dimensions relevant to the standard minimum-vent kits.
Simpson DuraVent Components Minimum Horizontal Vent Kit 2792
Starter Pipe Assembly (incl. inner & outer sections) 2768* 90° Elbow, Blk. 990B* 45° Elbow, Gal. 945 6” Straight, Blk. 908B* 9” Straight, Blk. 907B 11” - 14B\,” Adjustable Straight Section 911B 12” Straight 906 24” Straight 904B* 36” Straight 903B 48” Straight 902 Horizontal Vent Cap 984* Wall Plate 940* Vinyl Siding Shield 950 Snorkel Termination - 14” 982 Snorkel Termination - 36” 981 Wall Strap 988 Cathedral Ceiling Support Box 941 Storm Collar 953 Firestop Spacer 963 Flashing 0/12 - 6/12 943 Flashing 6/12 - 12/12 943S Steel Chimney Kit A 931 Kit B 932 Kit C 933 Masonry Chimney Kit 934 Vertical Termination Cap (High Wind) 991 Vertical Termination Cap (Low Profile) 980
*Included in Minimum Horizontal Vent Kit #2792
All DuraVent Straight vent pipe sections have a net length 1¹⁄₂” (37mm) less than the nominal dimension; i.e., a 6” (152mm) Straight pipe section has an effective length of 4¹⁄₂” (115mm).
CFM Vent Components
The following kits are available to meet the needs of most installations. All pipe has a 7” outer diameter and includes a 4” diameter inner section. A (CG) designa­tion indicates the part is finished in Charcoal Gray paint. Consult your dealer about other vent parts that may be appropriate to complete the installation.
Min. Through the Wall Vent Kit 7TFSSK
(1) 90-Degree Elbow (CG) (1) 24” Straight pipe (CG) (1) 24” - 42” Adjustable Straight Pipe (1) Side Wall Termination (1) Firestop (1) Zero-clearance sleeve (1) Hardware package (1) Finishing plate (CG) (1) Finishing collar (CG) (4) Charcoal Gray flue pipe rings
Starter Kit for Below Grade Installation 7TDVSKS
(1) Snorkel Termination (7TDVSNORK)
Vertical Termination Kit, 1/12-6/12 Pitch 7TDVSKVA
(1) Combination Horizontal Offset / Roof Support (1) Vertical Termination (1) Storm Collar (1) 1/12-6/12 Flashing (1) Finishing Plate (CG) (1) Finishing Collar (CG) (1) Polished Brass Flue Pipe Ring (1) Hardware Package
Vertical Termination Kit, 7/12-12/12 Pitch 7TDVSKVB
(1) 7/12 - 12/12 Flashing and all of the other Vertical Termination parts.
Vertical Termination, Flat Roof 7DVSKVF
(1) Flat Flashing and all of the other Vertical Termination parts.
Twist Lock 12” Straight Pipe (CG) 7TFSDVP12
(1) 12” Non-adjustable Pipe
Twist Lock 12”-18” Straight Pipe (CG) 7TFSDVP1218
(1) 12” - 18” Adjustable Pipe
Twist Lock 24” Straight Pipe (CG) 7TFSDVP24
(1) 24” Non-adjustable Pipe
Twist Lock 48” Straight Pipe (CG) 7TFSDVP48
(1) 48” Nonadjustable Pipe
Twist Lock 45-Degree Elbow (CG) 7TFSDVT45
for vertical offsets (1) 45-degree Elbow
Draft Hood Adapter FSDHAG NV Stove Kit 7FSSK
(1) 7” Diameter Polished Brass Trim Ring (1) 48” Nonadjustable Pipe (CG) (1) 24” Nonadjustable Pipe (CG) (1) Finishing Plate (1) Finishing Collar (CG) (1) 90 Degree Elbow (CG)
Stove Kit 7FSDHASK
Includes all parts in the 7FSSK plus the Draft Hood Adapter FSDHAG
Combination Offset/Roof Support 7DVCS Attic Insulation Shield 7DVAIS 7” Charcoal Gray Pipe Rings, (4) 7FSDRG 7” Polished Brass Pipe Rings (4) 7FSDRP Wall Thimble 942G
NOTE: Direct vent pipe may be used on the Natural
Vent system from the top of the draft hood adapter to the ceiling.
12
20007065
Stardance Direct Vent/Natural Vent Gas Heater
Install the Optional Fan
If you are installing the optional convection Fan Kit #2767 (FK26), continue here. If you are not installing a Fan Kit, go to Page 14, Venting System Assembly.
1. The fan kit includes a Blower Assembly and a Rheo­stat Assembly, connected by a cable. (Fig. 12) The Blower Assembly mounts to the bottom rear of the stove, and the Rheostat mounts to the valve bracket to the left of the valve. The assembly includes a ‘snapstat’ which automatically turns the fan On (or Off) above (or below) approximately 109˚. The Rheo­stat also provides a range of fan speed settings from Off (which overrides the snapstat function) to High. Unpack and inspect the Blower assembly. Confirm the fan spins freely.
WARNING
This appliance is equipped with a three-prong (grounded) plug for your protection against shock hazard and should be plugged directly into a prop­erly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
Not Used on RF Models
Not Used on Stardance
Snapstat Bracket
Snapstat/ Extension Assembly
4. The rheostat control switch attaches to the left side of the valve bracket at the front of the stove. (Fig. 15)
Remove retaining nut from shaft of rheostat. (if
preinstalled)
Insert the rheostat through the hole in the back
of the left side of the valve bracket, aligning the locator pin with the smaller hole in that bracket.
Thread the retaining nut onto the shaft of the
rheostat, tightening with a wrench. Do not over­tighten.
Attach the control knob to the rheostat shaft.
Use the wire tie to secure the fan and rheostat
wire harnesses together.
Rear Skirt
Sheet Metal Screws
Rear Skirt Insert
Fig. 13 Remove rear skirt insert.
ST313
Rheostat Assembly
Not Used on RF Models
Blower Assembly
ST473
Fig. 12 Fan kit components.
Connect to PC Board on RF Models Only
2. Remove the rear skirt insert panel at the bottom of the Rear Skirt (Fig. 13) and fasten the blower assem­bly to the firebox back with the two Phillips pan-head bolts originally installed in the firebox back. (‘1’, Fig.
14)
NOTE: Steps 3 and 4 do not apply when the RF
valve is used. After attaching blower assembly to the firebox, run the spliced female leads to the front of the stove and attach to back of RF valve. (Page 28, Fig. 51)
3. Attach the snapstat assembly to the snapstat bracket with two sheet-metal screws. (‘2’, Fig. 15) Attach the snapstat bracket to the stove with a hex-head bolt passing through the bracket and into the stove base. (‘3’, Fig. 14)
Star Washer
Sheet Metal Screws
Phillips Pan Head Bolts
Star Washer
NOTE: Shown without shell for clarification
Fig. 14 Attach the fan assembly and the snapstat.
Fig. 15 Attach the fan rheostat.
1
Rheostat Retaining Collar
Rheostat Knob
2
3
Snapstat
1/4” - 20 Hex Bolt
Snapstat Bracket
ST314
ST347a
20007065
13
Stardance Direct Vent/Natural Vent Gas Heater
CEMENT
CEMENT
Venting System Assemlby - Direct Vent
General Information
The Stardance is approved for installation only with the vent components listed on Page 12. Follow the vent component instructions exactly.
For U.S. installations: The venting system must con­form with local codes and/or the current National Fuel Gas Code, ANSI Z223.1/NFPA 54.
For Canadian installations: The venting system must conform to the current CSA B149.1 installation code.
Install the Vent Adapter Pipe
(CFM Corporation Vent Components)
1. Install the Restrictor Plate. Consult the ‘Vent Run
Specifications’ on Page 8 to determine whether the restrictor plate is needed. If so, put the restrictor plate in place within the inner flue collar as shown in Figure 16.
First Section of Vent Pipe
#8 x 1/2” Sheet Metal Screws
3” Inner Starter PIpe
ST211
Fig. 17 Connect the inner starter with the next section of in­ner vent pipe.
ST210
Fig. 16 Install the restrictor plate only if required for the vent­ing configuraiotn. Refer to Page 8.
2. Attach Inner Starter Pipe, (found in with the log­set), to the next section of inner pipe.
• Run a bead of sealant about 1/2” from the upper end of the Inner starter pipe and join the two sec­tions together.
• Drill three pilot holes into the Inner Starter and secure the assembly with three sheet metal screws. (Fig. 17)
3. Dry fit the Inner Pipe assembly to the stove for the purpose of determining the center line of the pipe on the wall.
• Side Wall Terminations: Dry fit the outer elbow
with the vertical outer vent and confirm the centerline alignment with the wall thimble opening.
4. Attach the Inner Vent Assembly to the stove.
• Run a bead of sealant around the bottom end of the starter pipe and attach the assembly to the stove using three 1/4-20 x 3/8” Phillips screws provided in the parts bag. (Fig. 18)
ST212
Fig. 18 Attach inner assembly to flue collar.
5. Install the Outer Adapter Pipe. Apply a 1/4” bead of cement around the inside wall of the pipe, about 1” from the end. Insert the pipe over the stove flue collar, keeping the vertical seam oriented to the back of the stove. Also, be sure to align holes on the pipe with the holes on the flue collar of the firebox. Fasten the pipe to the holes in the flue collar with the #12 x 1/2” sheet metal screws provided. (Fig. 19)
ST213
Fig. 19 Fasten outer pipe with #12 x 1/2” sheet metal screw.
14
20007065
Stardance Direct Vent/Natural Vent Gas Heater
CEMENT
Install the Vent Adapter Pipe
(Simpson Dura-Vent Components)
1. Install the Restrictor Plate. Consult the ‘Vent Run
Specifications’ on Page 8 to determine whether the restrictor plate is needed. If so, put the restrictor plate in place within the inner flue collar. (Fig. 16)
2. Discard the inner starter pipe shipped with the log-
set. Using the starter pipe assembly listed on Page 7, slide the inner section out to allow access.
• Run a bead of sealant around the bottom end of the starter pipe and attach the assembly to the stove using three 1/4-20 x 3/8” Phillips screws provided in the parts bag. (Fig. 20)
3. Install the Outer Adapter Pipe. Apply a 1/4” bead of cement around the outside surface, about one inch from the crimped end. (Fig. 21) Orient the vertical seam to the rear, and insert the crimped end of the outer pipe into the flue collar. Fasten with three sheet metal screws provided.
1/4-20 x 3/8 Phillips Screws
Fig. 20 Simpson Dura-Vent - install inner adapter pipe.
Inner Adapter Pipe
ST355a
Side Wall Termination Assembly
1. Locate the vent opening on the wall. Refer to Fig­ure 4, Page 6, to determine the opening centerline. It may be necessary to first position the stove and measure to find the hole location. Depending on whether the wall is made of combustible materials, cut the opening to the size shown in Figure 23. Com­bustible wall openings must be framed as shown in Figure 22.
CFM System
9³⁄₈
(240mm)
DuraVent System
VO584-100
Fig. 22 Locate vent opening.
2. Measure the wall thickness and cut the wall sleeve sections to proper length (MAXIMUM 12”). Assemble the sleeve with the #8 sheet metal screws supplied. Attach the firestop plate to the sleeve end with the holes. (Fig. 23) NOTE: The wall sleeve is required in combustible walls only.
3. Install the Wall Firestop/Sleeve assembly into the wall cutout and fasten the firestop to the wall cutout framing members. (Fig. 23)
9³⁄₈
(240mm)
Combustible Wall
10”
(254 mm)
Framing Detail
7¹⁄₂
(191 mm)
Noncombustible Wall
Fig. 21 Simpson Dura-Vent - install outer adapter pipe.
20007065
ST356a
12”
(305 mm)
Max. Length
Firestop
Fig. 23 Assemble the wall sleeve and firestop.
Sleeve
#8 Sheet Metal Screws
ZCS103
15
Stardance Direct Vent/Natural Vent Gas Heater
For DuraVent pipe only: Install vent pipe by aligning
the locking system together, sliding the pipes togeth­er and twisting clockwise.
• Install 90° elbow. Twist lock as before.
• Slide the wall plate over horizontal run before at taching the horizontal run to the elbow. Fasten wall plate to wall.
4. For CFM Vent Pipe only: If necessary, measure to determine the vertical length (X) of pipe required from the adapter pipe to the wall cutout centerline, including a 2” overlap at the joint. (Fig. 24) use a hacksaw or tin snips to trim the pipe as needed.
X
-
X
ST215
Fig. 25 Measure the horizontal length.
Trim Collar
Wall Sleeve
ST214a
Fig. 24 Determine the vertical pipe length.
5. Install first the inner then the outer straight pipe section(s), trimmed end down, to the point of the el­bow. Drill 3 holes through each joint and fasten with sheet metal screws.
6. Seal and install the elbow using 3 sheet metal screws at each joint.
7. Measure, and cut if needed, the appropriate length of pipe section needed to make the connection through the wall. Include a 2” overlap; i.e. from the elbow to the outside wall face, about 2” or the distance required if installing a second 90° elbow. (Fig. 25)
8. Slip the wall plate and trim collar over the interior end of the horizontal pipe and install into the wall sleeve. Seal the joint inside the wall plate if needed to keep cold air from being drawn into the home.
9. Seal the ends and connect the horizontal pipe to the elbow. Fasten the wall plate to the pipe with three sheet metal screws. Slide the trim collar up against the wall plate to cover the screws. (Fig. 26)
ST216
Fig. 26 Install the horizontal pipe and wall plate parts.
10. For both CFM and DuraVent Systems:
Wall Plate
Install the vent terminal. (Fig. 27) Apply high temperature sealant one inch from the ends of the inner and outer collars. Guide the inner and outer vent termination collars into the adjacent pipes. Double check that the vent pipes overlap the collars by 2”. Fasten the termination to the wall with the screws provided, and caulk the joint with weatherproof sealant.
11. For CFM only:
Install Charcoal Gray Pipe Rings (#7FSDRG) or Polished Brass Pipe Rings (#7FS­DRP) at pipe joints, if desired.
Recessed Wall
Caulk Plate Joint with Weatherproof Sealant
Fig. 27 Install the vent terminal.
ST217
16
20007065
Stardance Direct Vent/Natural Vent Gas Heater
Vent Termination Below Grade
Install Snorkel Kit #7FSDVSKS when it is not possible to meet the required vent termination clearances of 12” (305mm) above grade level. The snorkel kit will allow installation depth of down to 7” (178mm) below grade level. The seven inches is measured from the center of the horizontal vent pipe as it penetrates the wall. If the
venting system is installed below grade, a window well must be installed with adequate and proper drainage. (Fig. 28)
NOTE: Be sure to maintain side wall clearances and
vent run restrictions. Refer to Figures 5, 6, 7, and 8.
1. Establish the vent hole through the wall.
2. Remove soil to a depth of approximately 16” (400mm) below the base of the snorkel. Install a window well (not supplied). Refill the hole with 12” (305mm) of coarse gravel and maintain a clearance of at least 4” (100mm) below the snorkel. (Fig. 32)
3. Install the vent system as described on Pages 14-17.
4. Be sure to make a watertight joint around the vent pipe joint at the inside and outside wall joints.
5. Apply high temperature sealant around the inner and outer snorkel collars. Join the pipes and fasten the snorkel termination to the wall with the screws provided.
6. Level the soil to maintain a 4” clearance below the snorkel.
If the foundation is recessed, use extension brackets
(not supplied) to fasten the lower portion of the snor­kel. Fasten the brackets to the wall first, and then fasten to the snorkel with self-tapping #8 x 1/2” sheet metal screws. Extend the vent pipes out as far as the protruding wall face. (Fig. 29)
Wall Screws and Anchors
Snorkel Termination Cap
Drain
Window Well
Fig. 28 Snorkel kit installation.
Waterproof Seal Around PIpe
Firestop
ST218a
Recessed Wall
Firestop
Sheet Metal Screws and Bracket
Wall Screws and Anchor
Waterproof Seal Around Pipe
Fig. 29 Use extension brackets to mount snorkel against recessed wall.
Finishing Collar
7” Pipe
Wall Plate
ST219
Vertical (Through the Roof)
Vent Assembly
Note that all vertically terminated installations must include the restrictor plate included with the stove.
Refer to Page 8, Figure 8. Make certain the vent system conforms to all other
requirements for vertical termination as specified on Page 8.
This installation will require you to first determine the roof pitch and use the appropriate vent components. Refer to Pages 8 and 10, Figures 8 and 9.
1. Locate the final position of the stove, observing all clearances for both the vent and the stove.
2. Plumb to the center of the inner (4”) flue collar from the ceiling above, and mark that location.
3. Cut the opening:
CFM System: 9³⁄₈” x 9³⁄₈” (240 x 240mm) DuraVent System: 10” x 10” (254 x 254mm)
4. Plumb any additional opening through the roof or other construction that may be needed. In all cases, the opening must provide a minimum of 1” (25mm) clearance to the vent pipe.
5. Place the stove in its final position.
6. Install firestop(s) #7DVFS and Attic Insulation Shield #7DVAIS as needed. (Fig. 30) If there is a room above ceiling level, a firestop must be installed on both the bottom and top sides of the ceiling joists. If an attic is above ceiling level, an attic insulation shield must be installed.
7. Install the appropriate roof support and flashing, making certain that the upper flange of the flashing base is below the shingles. (Fig. 31)
8. Install appropriate pipe sections until the vent run reaches above the flashing. The enlarged ends of the vent sections always face downward.
20007065
17
Stardance Direct Vent/Natural Vent Gas Heater
9. Install the storm collar and seal around the joints. (Fig. 31)
10. Add additional vent lengths to achieve the proper overall height.
11. Apply cement to the inner and outer termination col­lars and install the terminal cap.
#7DVAIS Attic Insulation Shield
Use Four 8dNails
ST222
Fig. 30 Install firestops and attic insulation shield.
#7DVFS Firestop in Upper Floor
#7DVFS Firestop in Ceiling
Venting System Assembly - Natural Vent
General Information
The Stardance Heater is shipped from the factory as a Direct Vent Heater. It may be converted to a Natural Vent heater by installing the Vermont Castings Model Z31D00 FSDHAG Draft Hood Adapter.
The Stardance Heater is approved for installation as a Natural Vent. CFM Direct Vent pipe could be used directly after the Draft Hood Adapter up to the ceiling, then B-vent pipe must be used. Do not mix types of B-vent pipe; use components from one maker or the other. Follow the vent component maker’s instructions exactly. The heater will also accept standard or enam­elled 7” (178mm) diameter pipe, around the Type B venting, for decorative purposes only. (Fig. 32)
NOTE: The restrictor plate supplied with the stove is not used for Natural Vent applications.
Decorative 7” Pipe
4” B-vent Pipe
Draft Hood Adapter
CFM Direct Vent System may be used after Draft Hood up to the ceiling
Use three #5 sheet metal screws at each joint
Storm Collar
Flashing
#7DVSKV (A, B, or F) RoofSupport
Fig. 31 Roof support and flashing.
Sealant
Upper edge of flange goes under upper shingles
ST221
ST358
Fig. 32 Decorative 7” pipe may be fitted around the B-vent pipe.
The Stardance stove, when installed as a Natural vent heater, includes a vent safety switch. (Page 36, Figure
66) Operating the stove when it is not connected to a properly installed and maintained venting system, or tampering with or disconnecting the vent safety switch, can result in carbon monoxide (CO) poisoning and pos­sible death.
For U.S. installations: The venting system must con­form with local codes and/or the current National Fuel Gas Code, ANSI Z22.1.
For Canadian installations: The venting system must conform to the current CSA B149.1 installation code.
18
20007065
Stardance Direct Vent/Natural Vent Gas Heater
Install the Vent Pipe
Apply a bead of sealant around bottom end of inner starter pipe (found in bag with logset) and attach to stove. Apply a bead of sealant around top of inner starter pipe and install the Z31D00 FSDHAG Draft Hood according to Draft Hood instructions. (Fig. 33)
Attach the first section of venting to the draft hood. De pending on the length of the individual venting sections and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones. The sections of decorative pipe should be oriented with their seams (if any) toward the wall; sections usually do not need to be fastened at each joint, other than slip sections. If the layout includes a slip section, this should be the last section of pipe visible in the room, at the ceiling. Complete the venting according to the vent maker’s instructions.
Install the Log Set
1. Remove the logs from their packaging, and inspect
each piece for damage. DO NOT INSTALL DAM-
AGED LOGS.
2. Install the rear log centering it side to side on the sheet metal shelf at the back of the firebox. (Fig. 34) The log will touch both sides and the back wall of the firebox.
3. Install the right log by engaging hole on bottom with pin on the rear log. (Fig. 34) Then set right bottom side on the burner so the edge of the log touches the right side of the firebox. The right log does not use the locator pins on the burner to stay in place.
Left Log
Rear Log
Fig. 34 Install the back, left and right logs.
Decorative Grate
Right Log
LG141
4. Install the left log by engaging hole on bottom with pin on rear log. (Fig. 34) Then set left bottom side on the burner so the edge of the log touches the left side of the firebox.
5. Loosely sprinkle the lava rocks directly on top of the burner in front of and between the decorative grate and the right and left logs. Use the lava rock to cover
-
brackets on the burner. (Fig. 35)
Lava Rock
Fig. 35 Completed log installation.
LG142
Connect the Gas Supply Line
Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Stardance may be converted from one gas to another using the appropri­ate Fuel Conversion Kit listed on Page 39.
CAUTION
This appliance should only be connected by a qualified gas technician. Test to confirm manifold pressures as specified
below. The Stardance Heater and its individual shutoff
valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The Stardance Heater must be isolated from the gas supply piping system by closing its indi­vidual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig.
There must be a gas shutoff between the stove and the supply.
In order to connect Natural Gas, use a fitting with 3/8” NPT nipple on the valve side and 1/2” natural gas supply line with an input of 28,000 BTUs at a manifold pressure of 3.5” and minimum inlet sup­ply for adjustment of 5.5” w.c.
In order to connect Propane, use a fitting with 3/8” NPT nipple on the valve side and 1/2” pro­pane gas supply line with an input of 28,000 BTUs at a manifold pressure of 10.0” and minimum inlet supply for adjustment of 11.0” w.c.
20007065
19
Stardance Direct Vent/Natural Vent Gas Heater
In the U.S.; Gas connection should be made in ac­cordance with current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Since some municipalities have additional local codes, be sure to consult your local authority.
In Canada; consult the local authority and CSA-B149.1 installation code.
Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing.
Light the pilot according to the directions on Page 25, before going to the next step.
Burner Information
The appliance must only use the gas specified on the rating plate, unless converted using a Vermont Castings Fuel Conversion Kit. To convert from LP to Natural Gas use Kit #000-5021. To convert from Natural Gas to LP use Kit #000-5022.
Conversion instructions are provided with each kit and beginning on Page 31 in this manual.
THIS APPLIANCE SHOULD BE CONNECTED TO THE GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE TECHNICIAN.
THERE MUST BE A GAS SHUT-OFF BETWEEN THE STOVE AND THE SUPPLY.
In order to connect Natural Gas, use a fitting with 3/8”
NPT nipple on the valve side and 1/2” natural gas sup­ply line with an input of 28,000 BTUs at a manifold pres­sure of 3.5” and minimum inlet supply for adjustment of
5.5” w.c. In order to connect Propane, use a fitting with 3/8”
NPT nipple on the valve side and 1/2” propane gas supply line with an input of 28,000 BTUs at a manifold pressure of 10.0” and minimum inlet supply for adjust­ment of 11.0” w.c.
Air Shutter Adjustment
Air Shutter Adjustment Instructions
To adjust the air shutter, the following procedures should be followed:
1. Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Fig. 36)
2. Swing open the swiveling latches at the top left and right corners of the glass frame. (Page 35, Fig. 62)
ST474a
Fig. 36 Remove stove front.
3. Pull the top edge of the glass and frame assembly away from the firebox, and lift it off its supports on the bottom of the firebox face. Place the assembly out of the way on a flat, padded surface such as a counter protected by a towel.
4. Take the logset out of the firebox if previously in­stalled.
5. Remove the rear log bracket by unfastening the screw. (Fig. 37)
6. Remove the right and left log bracket assembly by unfastening the two screws which hold the burner in place. (Fig. 37)
7. Hold the burner at the right hand side and lift to clear the right burner leg. Then pull to the right to clear the injectors on the left hand side.
The Stardance is shipped from the factory with the air shutter adjusted to the minimum allowed opening. Refer to Table 1. Based on the altitude where the stove is located, a shutter adjustment is acceptable to provide a mixed balance of flame color/glow. To adjust the shutter opening, follow the steps below.
NOTE: The air shutter may only be adjusted to a more open position. The factory setting is the minimum allow­able air shutter opening. (Figs. 38 & 39)
Table 1. Air Shutter Adjustment Minimum rear injector air inlet openings.
Model Natural Gas LP Direct Vent 1/2” 1/2” Natural Vent 1/2” 1”
20
Remove Screws Rear Log Bracket
Pilot
Left & Right Log Bracket Assembly
Fig. 37 Remove rear log bracket and left and right log bracket assembly.
20007065
ST350
Stardance Direct Vent/Natural Vent Gas Heater
90°
PILOT
ADJ
TP
TH
TPTH
8. The air shutter is located on the bottom of the burner to the left. Unfasten the two nuts holding the shutter in place. The shutter may be adjusted between the factory adjusted 1/2” to fully open. Reassemble the shutter to allow the rear injector air inlet to close from the minimum 1/2” opening to fully open. (Fig. 39) You may have to try more than once to find the correct air shutter opening for best results depending on your altitude.
Refer to Table 1
Fig. 38 Air shutter in original from-the-factory position.
Front Injector Air Inlet
Air Shutter (Original Position)
Burner
ST352
Air Shutter (May be adjusted up to fully open)
Burner
Left Burner Leg
Injector Shoulder
ST353
Fig. 40 Be sure to maintain 90° angle at left burner leg.
Complete the Assembly
• Open the swiveling latches (cams) on the top left and right corners of the glass frame.
• Position the glass and frame against the firebox by placing the bottom edge on the brackets on the bot­tom face of the firebox.
• Swing the assembly against the firebox, and close the latches firmly against the pins protruding from the firebox top.
Install ON/OFF Switch
Rear Injector Air Inlet
ST351
Fig. 39 Air shutter adjusted.
9. Refasten the two nuts and assemble the burner into the unit by sliding the burner in at an angle with the left side lower than the right side. Slide the left side onto the injectors. Lower the right hand side down into place. Make sure the burner is as far left as pos­sible and the injector shoulders are inside the burner. NOTE: It is very critical to keep the left burner leg, which holds the injectors, at a 90° angle to the base. (Fig. 40) This keeps the orifices aligned with tubes on the inside of the burner. Failure to do so could affect the flame appearance and performance of the unit.
10.Refasten the right and left log bracket assembly.
11.Refasten the rear log bracket.
12.Replace logs.
13.Replace glass and stove front.
Follow lighting instructions on Page 25. Check flame color appearance. NOTE: Allow stove to burn for at least 1/2 hour to establish full flame color.
Should color need further adjustment, repeat steps 1
- 12 for air shutter adjustment.
The switch assembly parts are found in the parts bag.
1. Attach switch assembly to left rear side of stove shroud (when facing shroud) using two screws and existing holes in shroud. (Fig. 41)
2. Run wires down back of stove, under bottom of rear shroud to valve.
3. Attach wires to valve terminals. (Fig. 42)
Switch Assembly
Screws
Fig. 41 Attach switch assembly to rear shroud.
Fig. 42 Attach switch wires to valve.
Existing Holes
ST315
ST228
20007065
21
Stardance Direct Vent/Natural Vent Gas Heater
Thermostat Connection (optional)
Use only a thermostat rated for 500 millivolts.
Check the table below for the appropriate gauge ther­mostat wire to use for the length of lead required in your installation. Thermostat
Wire / Gauge Maximum Run
18 20 feet 16 20 - 40 feet 14 up to 60 feet
1. Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors.
2. Connect the thermostat wires to the valve. (Fig. 42)
Install the Front Plate
Hold the front plate by the window bars and lift it into position, engaging the two steel tabs on the top corners behind the adjacent bosses in the side plates. (Fig. 43) Then seat the Front against the sides so the tabs at the bottom lip engage with the notches in the stove legs.
When properly installed, the bottom of the Front Plate cannot be pulled away from the sides without also lifting it .
Engage steel tabs gehind the cast iron bosses
Control Door
Bottom tabs engage notch in the leg.
Fig. 43 Install the front plate.
ST474
This completes assembly of the Stardance stove.
22
20007065
Operation
LO
HI
Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
The Stardance is operated with the operable door front plate in place with the doors open or closed. To open the front doors, insert the handle into the door latch stub and turn it to the left and up. (Fig. 44) When not in use, the handle may be stored in the handle holder on the right side of the rear shroud. (Fig. 47)
Clockwise to Open
Counterclockwise to Close
ST621
Fig. 44 To open the front doors, turn handle clockwise.
Stardance Direct Vent/Natural Vent Gas Heater
ST476
Fig. 46 Pilot assembly location.
Flame & Temperature Adjustment
For stoves equipped with HI/LO valves, flame adjust­ment is accomplished by rotating the HI/LO adjustment knob located near the center of the gas control valve. (Fig. 47)
Handle Holder
ST624
Fig. 45 When not in use, store handle in the handle holder.
Your First Fire
Read these instructions carefully and familiarize your­self with the burner controls. Locate the pilot assembly, Figure 46. Follow the lighting instructions on Page 24 exactly.
During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within an hour or so, however, you can open a window to provide fresh air to alleviate the condition.
Pilot and Burner Inspection
Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figure
54. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for as­sistance. Do not operate the heater until the pilot flame is correct.
Follow regular maintenance procedures as described on Page 33.
Fig. 47 Flame adjustment knob for Honeywell valve.
Flame Characteristics
It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to Figure 48. If any of the flames appear abnormal, call a service person.
CO105c
Red Glow
20007065
LG143
Fig. 48 Correct pilot and burner flame patterns.
23
Stardance Direct Vent/Natural Vent Gas Heater
PILOT
ON
OFF
ON
P
I
L
O
T
O
F
F
O
F
F
5
4
3
2
1
O
F
F
P
i
l
o
t
3/8" - 1/2"
Lighting and Operating Instructions
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A. This heater has a pilot which must be lit manu
ally. When lighting the pilot follow these instruc­tions exactly.
B. BEFORE LIGHTING smell all around the
heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any fireplace
Do not touch any electric switch
Do not use any phone in your building
Immediately call your gas supplier from a
neighbor’s phone.
Lighting Instructions
-
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call
the Fire Department
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service techni­cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.
1. STOP! Read the safety information above.
2. Turn off all electrical power to the fireplace.
3. For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the ON/OFF switch to “OFF” position or set thermostat to lowest level.
4. Open control access panel.
5. Push in gas control knob slightly and turn clock­wise to “OFF”.
Euro SIT SIT NOVA
Honeywell
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety infor­mation above. If you do not smell gas, go to the next step.
7. Remove glass door before lighting pilot. (See Glass Frame Removal section).
8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counterclockwise
to “PILOT”.
10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depress­ing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.
If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
If after several tries, the pilot will not stay lit, turn the gas control knob to “OFF” and call your service technician or gas supplier.
11. Replace glass door.
12. Turn gas control knob to “ON” position.
13. For RN/RP appliances turn the ON/OFF switch to “ON” position or set thermostat to desired setting.
14. Turn on all electrical power to the fireplace.
To Turn Off Gas To Heater
1. Turn the ON/OFF switch to Off position or set the thermostat to lowest setting.
2. Turn off all electric power to the fireplace if service is to be performed.
24
3. Open control access panel.
4. Push in gas control knob slightly and turn clock­wise to “OFF”. Do not force.
5. Close control access panel.
20007065
Stardance Direct Vent/Natural Vent Gas Heater
Troubleshooting / Honeywell #8420 Gas Control System
NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position.
WARNING: REMOVE THE GLASS PANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK.
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION
1. Spark ignitor will not light
2. Pilot will not stay lit after carefully fol­lowing the lighting instructions
3. Pilot lights, no gas to burner, valve knob ON, remote switch (rocker switch) ON
4. Frequent pilot out age
20007065
A. Defective or misaligned elec
trode at the pilot
B. Defective ignitor (push button)
A. Defective pilot generator (ther
mocouple)
B. Defective automatic valve op-
erator
A. Remote switch or wires defec
tive
B. Thermopile may not generate
sufficient voltage
C. Plugged burner orifice D. Defective automatic valve op
erator
-
A. Pilot flame may be too low or
high, (blowing or lifting), caus­ing the pilot to drop out
B. Possible blockage of the vent
terminal
Using a match, light pilot. If pilot lights, turn off pilot
­and push the ignitor button again. If pilot will not light, check gap at electrode and pilot - it should be 1/8” to have a strong spark.
Push piezo ignitor button. Check for spark at elec­trode and pilot. If there is no spark at the pilot, and electrode wire is properly connected, replace ignitor.
Check pilot flame. It must impinge on the thermo-
­couple or thermopile. NOTE: This pilot burner as­sembly uses both a thermocouple and a thermopile. The thermocouple operates the pilot flame. Tighten the thermocouple. The thermopile operates the main valve (ON and OFF). Clean and/or adjust pilot for maximum flame impingement on thermocouple and thermopile.
Turn valve knob to ‘Pilot’. Maintain flow to pilot; mil­livolt meter should read greater than 10mV. If the reading is okay and the pilot does not stay on, re­place the gas valve. NOTE: An interrupter block (not supplied) must be used to conduct this test.
Check rocker switch and wires for proper connection.
­Use jumper wires across terminals at rocker switch. If burner lights, replace rocker switch. If okay, use jumper wires across rocker switch wires at the valve; if burner lights, wires are faulty or connections are bad.
1. Be sure wire connections from thermopile at gas
valve terminals are tight and thermopile is fully inserted into pilot bracket.
2. One of the rocker switch wires may be grounded.
Remove rocker switch wires from valve terminals. If burner now stays lit, trace rocker switch wiring from ground. It may be grounded to the appliance or the gas supply line.
3.
Check the thermopile with a millivolt meter. Take reading at thermopile (“TP” and “TP/TH”) terminals of gas valve. Should read 325 millivolts minimum while holding valve knob depressed in PILOT po­sition and with rocker switch OFF. Replace faulty
thermopile if reading is below specified minimum. Check burner orifices for debris, and remove. Turn knob to ON, place rocker switch to ON, millivolt
­meter should read greater than 10 mV. If the read­ing is okay and the burner does not light, replace the valve.
Clean and/or adjust pilot flame for maximum flame impingement on thermocouple and thermopile.
Check the vent terminal for blockage.
25
Stardance Direct Vent/Natural Vent Gas Heater
LOCAL
REMOTE
ON
PILOT
OFF
LED
Instructions for RF Comfort Control Valve
The Comfort Control valve allows remote control of tem­perature, fan and flame appearance.
NOTE: The antenna should hang in free air away form grounded metal.
Operation
1. If the manual switch is in remote position, switch it to LOCAL. (Fig. 49)
2. Turn the pilotstat knob counterclockwise from OFF to the PILOT position, push the knob down, and hold in position. The pilot valve opens and allows gas to flow to the pilot burner.
3. Push plunger on the piezo until the pilot burner is lit. When the pilot burner is lit, the LED on the control will come on after approximately 40 seconds and will provide 1 short blink continuously in the normal mode. When the light turns off which will be approxi­mately 10 seconds after it has been continuously red, the receiver/valve is fully powered.
Motor Top Cap
Piezo Ignitor
Shut Off Procedure
If the manual switch is in the REMOTE position, the transmitter can shut off the main burner and fan. How­ever, the control is still on and a command from the transmitter can turn on the main burner or fan.
To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The transmitter cannot turn on the main burner or fan.
Transmitter Operation
Off Mode
In the OFF mode, the fireplace flame and fan are off, the display will show OFF and displays the room temperature. If the receiver is in REMOTE mode, the fireplace will shut off.
Display Room Temperature Set Temperature Flame Height Level
Mode Auto On Off
Countdown Timer
Fan Speed Level Countdown Timer Low Battery
Flame
Up Increase Flame Height, Fan Speed Timer, or Set Point
LED
Local/Remote Switch
Fig. 49 Comfort control valve.
Pilotstat Knob
Plug
Antenna
FP1037
4. Release the knob. The shaft will move upward. The pilot burner should now stay burning. If the pilot burner goes out, repeat step 2.
5. Turn the knob counterclockwise to the ON position. If the manual switch is in the LOCAL position, the main burner will turn on immediately.
6. ON the initial use of a transmitter, a recognition operation is required between the receiver/valve and transmitter. Change the switch from LOCAL to RE­MOTE. Press the fan or flame button on the transmit­ter within 30 seconds. The LED will blink indicating the transmitter will now work with the receiver/valve. If the switch continues in the REMOTE position, the transmitter will now control the main valve, flame modulation level and fan control.
7. If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting and the fan will be at the highest fixed speed. The trans­mitter will control the fan only.
26
Down
Fan
FP1039
Fig. 50 Transmitter diagram.
Decrease Flame, Fan Speed Timer or Set Point
On (Manual) Mode
In the ON mode, the room temperature, flame and fan levels will be shown. MANUAL will appear next to both the flame and fan icons.
When the control is in the ON mode, the flame and fan levels, and delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit.
Delay Timer Mode
The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes.
20007065
Stardance Direct Vent/Natural Vent Gas Heater
FAN
Antenna
Red White
Red
White
Auto Mode
In the AUTO mode, the room temperature, set tem­perature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons.
When the control is in the AUTO mode, the main burner will turn on/off or modulate based on the heat needed to maintain the set temperature. The flame level will change automatically to optimize the heat output needed to maintain the set temperature. To change the set temperature, press the up or down key. Pushing a key once will change the temperature by one degree.
In the AUTO mode, the fan speed will increase with increasing flame height or decrease with decreasing flame height. “AUTO” is displayed next to the flame and fan icons.
Fan Override During Auto Mode
If a lower or higher fan speed is desired when operating in the AUTO mode, the fan speed can be overridden by pushing the fan button followed by the up or down key. Pushing a key once will change the fan level by one unit. In this mode “AUTO” is displayed next to the flame icon and “MANUAL” is displayed next to the fan icon.
Change Between F/C Temperature Units
Push the up and down arrow keys simultaneously for at least 3 seconds to toggle between Fahrenheit and Celsius units.
Disable Thermostat Function
To disable the thermostat function in the AUTO mode, push the time and down keys simultaneously for at least 3 seconds.
To Change Batteries
1. Remove cover on the backside of the transmitter. Install 3 AAA batteries as shown and reattach cover.
2. Once steps 1-3 in OPERATION are completed, receiver/valve and transmitter are now ready. Press any button on transmitter for recognition process to occur between the receiver/valve and transmitter.
3. Use functions as described in TRANSMITTER sec­tion.
Troubleshooting
1. Locate LED light on valve.
2. LED will blink after every valid command received by the transmitter; this is not an error.
3. Failure codes may occur anytime after pilot burner is lit.
4. Sequence is failure code followed by light not blink­ing for 30 seconds.
20007065
Pilot
Assembly
Fan
White Dots
FP1038
Fig. 51 Comfort valve wiring diagram.
Valve
(Bottom View)
5. In the event of multiple failure codes, next failure code follows previous failure code by approximately 3 seconds.
If an Error Code 3 is observed while performing the testing, complete the following:
1. Make sure the spade connectors are pushed all the way on. If rhe Error Code 3 is still showing, then go to the next step.
2. Switch the front two thermopile leads with the back two. Be sure the white lead is connected to the spade with the white dot next to it. If the Error Code 3 is still showing, replace the thermopiles.
If an Error Code 8 is observed while performing the testing, complete the following:
1. Confirm the valve is not in REMOTE mode.
• If the valve is producing Error Code 8 and in RE­MOTE mode, the valve is defective and should be replaced.
• If the valve is in LOCAL mode and producing Error Code 8, then go to the next step.
2. Slide the Remote/Local switch to REMOTE and teach the valve a transmitter (see item 6, page 32). The Error Code will clear itself after approximately
1.5 minutes and return to normal operation.
LED Count Service Action 8 Replace valve 7 Confirm stepper motor connection exists 5 Confirm fan connection exists and works 4 Confirm gas type; jumper in place 3 Replace thermopiles 2 Turn fan ON
NOTE: Some keys are not active.
27
Stardance Direct Vent/Natural Vent Gas Heater
Comfort Valve System Control Sequence of Operation with Transmitter
Set manual switch to local or remote
Light pilot burner
Did the LED stop blinking?
Release pilotstat
knob
Yes
Turn pilotstat knob from PILOT to ON
five minute wait period
Review LED
failure analysis
Cycle switch once and leave in remote. Pressy any key on transmitter for recognition operation
Choose Manual or Remote path. Set switch to manual or remote.
If manual switch is set to LOCAL, did main burner light and fan turn on?
Yes
Turn pilotstat knob to PILOT to turn off main burner.
Turn pilotstat knob to OFF to turn valve completely off.
Local Path
Move switch from local to remote. Press any key on transmitter. Move switch back to local.
If the manual switch is set to REMOTE, press the mode but­ton to display “ON”. Does transmitter con­trol the main burner and fan?
Yes
Does transmitter change levels of flame height, fan speed?
Set levels of flame height and fan to “0: to shut off main burner and fan.
On Path
Move switch from manual to remote. Press any key on transmitter.
No
28
Turn pilotstat knob to OFF to turn valve completely off.
20007065
Auto Path
If the manual switch is set to REMOTE, press the mode button to display AUTO on the transmitter. Does the transmitter dis­play the room and tempera­ture setting?
Stardance Direct Vent/Natural Vent Gas Heater
Move switch from LOCAL to REMOTE. Press any key within 30 seconds.
If the setting is above room temperature on the transmitter, does the main valve and fan turn on?
If the settings is below room temperature on the transmitter, does the main valve and fan turn off?
Turn pilotstat knob to OFF to turn valve completely off.
No
No
20007065
29
Stardance Direct Vent/Natural Vent Gas Heater
PILO
T
O
N
O
F
F
PILO
T
AD
J
L
O
H
I
L
O
H
I
L
O
H
I
Fuel Conversion Instructions
WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruc­tions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is respon­sible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.
CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before pro­ceeding with the conversion.
Main Gas
ST226
Gas Supply Inlet
Fig. 52 Attach the gas line to the left side of the valve.
Line
Remove Screws Rear Log Bracket
Pilot
Left & Right Log Bracket Assembly
ST350
Fig. 53 Remove the rear log bracket and left and right log bracket assembly.
8. Remove injector orifices from left burner leg using 1/2” wrench. (Fig. 60)
9. Install conversion orifices. (Refer to Table 2)
Models 3900, 3910 (R Models) Only Honeywell Valve
10. Remove cap from Hi-Lo knob. This can be accom­plished by lifting the plastic cap off the screw. (Fig.
54)
11. Remove the screw from center of Hi-Lo knob with small screwdriver turning counterclockwise. (Fig. 54)
Cap
Lift Open
Conversion Precautions
Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance.
Conversion Procedure
1. Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Page 33, Fig. 63)
2. Swing open the swiveling latches at the top left and right corners of the glass frame. (Page 34, Fig. 64)
3. Pull the top edge of the glass and frame assembly away from the firebox face. Place the assembly out of the way on a flat, padded surface such as a coun­ter protected by a towel.
4. Remove the logset from the firebox.
5. Remove the rear log bracket by unfastening the screw. (Fig. 53)
6. Remove the right and left log bracket assembly by unfastening the two screws which hold the burner in place. (Fig. 53)
7. Hold the burner at the right hand side and lift to clear the right burner leg. Then pull to the right to clear the injectors on the left hand side.
30
Hi/Lo Knob
Center Screw
CO100
Fig. 54 Remove center screw from Hi/Lo knob.
12.Insert blue painted screw when converting to natural gas and red painted screw when converting to LP.
13. Tighten screw (do not over tighten), replace cap.
SIT 820 Valve
14. Using TORX T20 bit, remove and discard the three (3) pressure regulator mounting screws (A), pressure regulator tower (B) and the spring and diaphragm assembly (C). (Fig. 55)
15. Insure the rubber gasket (D) is properly positioned and install the new HI/LO pressure regulator assem­bly to the valve using the new screws (E) supplied with the kit. Tighten the screws securely. (Ref. torque = 25 in/lb) (Fig. 56)
16. Install the enclosed conversion label (F) to the valve body where it can easily be seen. (Fig. 57)
20007065
Stardance Direct Vent/Natural Vent Gas Heater
A
B
C
O
F
F
P
I
L
O
T
O
D
E
F
O
F
F
P
I
L
O
T
O
Pilot Hood
Pilot Bracket
CO105a
Fig. 57 Remove pilot hood.
FC107
Fig. 55 Remove mounting screws, pressure regulator tower and spring and diaphragm assembly.
FC108
Fig. 56 Replace regulator.
Index Tab
Allen Wrench
Snap Ring
CO106a
Fig. 58 Remove pilot orifice.
Pilot type 2
• Loosen pilot hood turning counterclockwise using a
7/16” wrench. (Fig. 59) NOTE: You may use pen­etrating oil to prevent pilot hood threads from seizing up.
• Remove pilot orifice with needlenose pliers. (Fig.
60) NOTE: Use a wrench to hold pilot tube in place while removing the orifice.
• Install the conversion orifice.
• Reinstall pilot hood and tighten until mark on pilot hood aligns with mark on pilot bracket.
NOTE: Be sure burner leg remains at a 90° angle to
firebox base after conversion.
Pilot Orifice Conversion
1. Locate pilot. (Fig. 53)
Pilot
2. Replace pilot orifice.
Pilot Type 1
• Remove pilot hood by lifting up. (Fig. 57) Do not
remove snap ring to remove pilot hood. NOTE: It is not necessary to remove the pilot tube for conver­sion.
• Remove pilot orifice with Allen wrench. (Fig. 58)
Index Marks
Pilot Bracket
CO105
Fig. 59 Remove pilot hood. (Your pilot may have a different appearance.)
• Install the conversion orifice.
• Reinstall pilot hood. Be sure to align hood with index tab.
Fig. 60 Remove pilot orifice.
20007065
Pilot Orfice
CO106b
31
Stardance Direct Vent/Natural Vent Gas Heater
LOCAL
REMOTE
ON
PILOT
OFF
LED
90°
Models 3940, 3950 (RF Models) Only
16. Follow procedure for pilot type 2 to replace pilot orifice.
17. Remove and replace plug on lower right hand side of the valve; Red for LP and Blue for NG. (Page 26, Fig. 49)
18. Remove motor top cap. Depress and turn center plunger until arrow points to correct screw. Red for LP and Blue for NG. NOTE: Plunger will “snap” into NG position when arrow is close to blue screw. It will not “snap” at LP (Red) position. (Fig. 61)
19. Insure manifold pressure remains between 3.2”
- 3.5” w.c. for NG and 9,5” - 10” w.c. for LP. To adjust the manifold pressure, for NG, using a torque #10 key turn the blue screw clockwise to increase the manifold pressure. Turn the screw counterclockwise to decrease the pressure. Use the red screw to adjust LP.
20. Replace motor top cap.
Motor Top Cap Center Plunger
Valve
All Models
21. Replace burner. Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. Lower the right hand side down in to place. Make sure the burner is as far left as possible and the injector shoulders are inside the burner.
NOTE: It is very critical to keep the left burner leg,
which holds the injectors, at a 90° angle to the base. (Fig. 62) This keeps the orifices aligned with the tubes inside burner. Failure to do so could affect the flame appearance and performance of the unit.
22.Place conversion label on valve.
23.Reinstall the right and left log bracket assembly.
24.Reinstall the rear log bracket.
25.Replace logs.
26.Replace glass and stove front.
Conversion is complete.
Left Burner Leg
Injector Orifice
Blue - NG
Red - LP
Fig. 61 Depress and turn center plunger.
Conversion to Natural Gas Input (Btu/h)
Kit # Front Part # Rear Part # Minimum Maximum
000-5021 000-5011
#54 / .055” 30000514 #44 / .086” 30000334 19,000 28,000
Conversion to LP Input (Btu/h)
Kit # Front Part # Rear Part # Minimum Maximum
000-5022 000-5012
#69 / .029” 30000513 #54 / .055” 30000514 20,000 28,000
FP1037b
ST353a
Fig. 62 Remove and replace injector orifices.
Table 2. Injector Orifice Size Matrix
32
20007065
Stardance Direct Vent/Natural Vent Gas Heater
Maintenance
Your Stardance Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly.
Annual System Inspection
Have the entire heater and venting system inspected annually by a qualified gas technician. Replace any worn or broken parts.
Logset and Burner /
Cleaning and Inspection
Cleanliness is critical to the proper function of the heater. The logset and burner must all be kept free of dust and unobstructed by debris. Inspect these areas before each use and clean as necessary.
1. Turn the burner OFF and let the heater cool com­pletely before cleaning.
2. Lift the Stove Front up and then swing the bottom out to disengage it from the heater shell. (Fig. 64)
3. Carefully remove the glass and frame assembly and place it out of the way on a flat, padded surface such as a counter protected by a towel.
4. Carefully inspect the Logs for damage. Contact your local dealer if any damage is evident. DO NOT OP-
ERATE THE HEATER WITH DAMAGED LOGS.
5. Use a soft bristled brush to sweep dust or debris from the Logs, Pilot and Burner. Use care as the logs are fragile and susceptible to damage. DO NOT USE
A VACUUM TO CLEAN THE LOGS OR BURNER.
6. Replace the glass panel and frame assembly.
7. Replace the Stove Front.
CAUTION
TURN THE PILOT OFF BEFORE PAINTING. AL­LOW THE HEATER TO COOL COMPLETELY BE­FORE PAINTING.
Cleaning the Glass
WARNING: Allow the glass cool completely before attempting to clean.
It will be necessary to clean the glass periodically. Dur ing start-up, condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a non-ammonia household cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleaned two or three times during each heating season depend­ing on the circumstances present.
Clean glass after first two weeks of opera­tion.
-
Glass Replacement
Replace glass only with CFM Corporation approved parts. Refer to Page 36 for Replacement Parts. Refer to Figure 63 and previous instructions for removal of the damaged glass frame.
Care of Cast Iron
An occasional dusting with a dry rag will help keep the painted surfaces looking new. Use high-temperature stove paints, available through your local dealer, to touch-up areas as needed. Clean areas to be painted with a wire brush and be sure to cover the logs, burner and valve assembly, glass and frame assembly. Apply the paint sparingly; two light coats of paint will give bet­ter results than a single heavy coat.
Clean porcelain enamel surfaces with a soft, damp cloth. Do not use abrasive cleaning agents. If neces­sary, use only a cleaning agent formulated especially for use on porcelain enamel surfaces.
20007065
ST474a
Fig. 63 Remove the stove front.
33
Stardance Direct Vent/Natural Vent Gas Heater
Fig. 64 Release the latches to release the glass frame.
ST208
Inspect the Vent System Annually
Have the vent system inspected annually by a qualified technician. Shut off the main gas supply before inspect­ing the system. Both the inner exhaust pipe and the out­er combustion supply pipe must be checked to confirm that they are unblocked and in good condition.
Check the Gas Flame Regularly
Gasket Replacement
The Stardance Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer.
Shut off the gas supply and allow the stove to cool. Wear safety goggles and a dust mask.
1. Remove the Front, Glass Frame and Glass Panel. (Figs. 63 & 64) Remove the old gasket. Use a razor blade to separate the glass and gasket from the frame, and to clean the glass of any remaining cement or bits of gasket. Use a cold chisel if neces­sary.
2. Determine the correct length of gasket by laying it out around the edge of the glass. Allow an extra 1
- 2” (25-50mm). Mark the spot to be cut. Use a utility knife.
3. Starting on a long edge, remove about 6” of the pro tective paper strip and apply the flat adhesive face of the gasket around the outside-facing edge of the panel. Continue around the panel, applying a bout 6” at a time and being careful to not stretch the mate­rial. Do not overlap the gasket ends. (Fig. 65)
4. Apply a thin bead of high temperature silicone rubber sealant along the inside corner of the glass frame, all around the perimeter. Place the flat gasketed side of the glass panel back into the steel frame. Pinch the rounded inside-facing gasket material to bulk it up.
5. Replace the glass frame and front panel as previ­ously described.
-
To ensure that the stove is operating properly, check the flames periodically to confirm that they match Figure 64. The flames will be blue during the first 15-20 minutes of operation, and will gradually turn to yellow after that.
Do not use your stove if the flame pattern differs from that shown here. Contact your Vermont Castings dealer or a qualified technician for help.
Red Glow
LG143
Fig. 66 Correct flame pattern.
Stove Disassembly
If there is ever a need to remove the firebox assem­bly from the stove shell, support the firebox with solid stands about 6” (152mm) tall under the left and right outer edges of the firebox base. Do not set the firebox assembly directly on the floor; this can damage the control valve and/or the gas lines from the valve to the firebox.
Before removing the firebox from the shell, disconnect the on/off switch wires from the valve. If the assembly includes the optional fan, disconnect the fan rheostat. If the installation includes a wall thermostat, disconnect the thermostat leads from valve.
Disconnection and reconnection to the gas line should only be done by a qualified gas service technician.
Upon reinstallation, the vent system must be sealed to the firebox as shown in the installation section, Page
14. Also be sure the logs are placed in the firebox cor­rectly, as shown in Page 19, Figures 34 & 35.
ST179
Fig. 65 Wrap the gasket material around the outside iedge of the glass.
34
20007065
OFF
ON
Therm
opile
Black
Black
Millivolt
Gas Valve
TP/TH
TP
TH
Wiring Diagrams
Thermostat
(Optional)
Therm
opile
Black
Black
Millivolt
Gas Valve
TP/TH
TP
TH
Thermocouple
Safety Limit
Switch
Valve
FAN JUNCTION BOX
FAN
POWER
CORD
Strain Relief
Chassis Ground
B
L
K
GRN
GRN
WHT
ON / OFF Rheostat
Chassis Ground
RHEOSTAT / SNAPSTAT
BOX
Snapstat
BLK
B
L
K
BLK
BLK
B
L
K
WHT
MOTOR
SNAPSTAT
ON/OFF RHEOSTAT
WHT
WHT
BLK
BLK
BLK
GRN
BLK
On/Off Switch Wiring
Optional Thermostat Wiring
Stardance Direct Vent/Natural Vent Gas Heater
ST124b
Fig. 67 On/Off switch and optional thermostat circuit.
NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED WITH THE APPLIANCE, MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE SF-2, 200°C WIRE OR ITS EQUIVALENT.
Fig. 68 Draft hood adapter wiring.
20007065
ST124c
ST153
Schematic Diagram
ST665
ST234
Fig. 69 Stardance fan circuit.
35
Stardance Direct Vent/Natural Vent Gas Heater
1a
1b
1c
PILOT
ON
OFF
PILOT
ADJ
L
O
H
I
CEMENT
2
5
6
7
19
8a,b
20
4
18
21
25a,b, c,d
31
24
32
LOCAL
REMOTE
ON
PILOT
OFF
LED
9a,b
26
33
35
34
10a
11
12
13
14
16
15
10b
10c
17
30
27
28
29
36
3
22
23
38
39
40
41
42
48a,b
49
CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
Stardance Direct Vent/Natural Vent Gas Heater (SDV30)
Models 3900-3916, 3940-3956
Ref. Description SDV30
1. Gas Log Assembly - SDV30 20003458
1a. Log Rear (V21) 20003459 1b. Log Right (V22) 20003460 1c. Log Left (V23) 20003461
36
20007065
Stardance Direct Vent/Natural Vent Gas Heater
Stardance Direct Vent/Natural Vent Gas Heater (SDV30)
Models 3900-3916, 3940-3956 (continued)
Ref. Description SDV30
2. Gasket Cement 1206122
3. Manifold Assembly 20003739
4. Lava Rocks Burner 57897
5. Gasket, Glass - Med. Knit - RDV40 1203702
6. Glass, DV25 1601691
7. Glass Frame Assembly - SDV30 30000127 8a. Valve RN Honeywell VS8420E 2038 (Serial #’s up to 8738)* 10001782 8b. Valve RP Honeywell VS8420E 2020 (Serial #’s up to 8738)** 10001759 9a. Valve Gas Honeywell Convertible RFN RV8310E 20003719 9b. Valve Gas Honeywell Convertible RFP RV8310E 20003720 10a. Pilot Assembly 3Way N/DV RN 0.199.706 10002264
Pilot Assembly 3Way N/DV RP 0.199.703 10002265 10b. Pilot, PSE - NA175 20001115
Pilot, PSE - LP175 20001116 10c. Pilot Assembly 3Way DV/RFN CS3003A2009 20002266
Pilot Assembly 3Way DV/RFP CS3003A2017 20002268
11. Thermocouple 24” 53373 7531137
12. Electrode Ignitor w/Cable SIT24 10001297
13. Pilot Top Convertible 10002266
14. Thermopile 18” RS 51827 7533113
15. Nut Electrode SIT #0.974.144 57886
16. Tubing Pilot w/Fittings 1/8 x 24” 10001296
17. Thermopile - PSE for RF Pilots 20002400
18. Burner Housing Assembly NG/LP 20002214
19. Switch ON/OFF - RN/RP Models 30000874
20. Grate, Burner - JDV 20002167
21. Wiring Harness - FSDV32 RN/JDV 10002582
22. Right Log Bracket 20005259
23. Left Log Bracket 20005258
24. Door, Control - FS/HM 1301087 25a. Orifice Hood #69 - Front - LP 30000513 25b. Orifice Hood #54 - Front - NG 20000130 25c. Orifice Hood #54 - Rear - LP 20000130 25d. Orifice Hood #44 - Rear - NG 30000334
26. Top, Stardance DV Refer to Enamel Parts Chart Page 38
27. Nut, Hex Jam 3/8 -16 TOPLK-Z 1203290
28. Pawl Assy, Ash Door - ENC 5004025
29. Front Steel Handle/Shaft - NI/VER 30002717
30. Handle Pkg, Ceramic w/Screw 0004345
31. Gasket, Base Pan - JDV 20002282
32. Gasket, Base Pan Inner 20002566
33. Front, Stardance OP Dr Refer to Enamel Parts Chart Page 38
*When converting to SIT valve, must order RP275 **When converting to SIT valve, must order RP269
20007065
37
Stardance Direct Vent/Natural Vent Gas Heater
Stardance Direct Vent/Natural Vent Gas Heater (SDV30)
Models 3900-3916, 3940-3956 (continued)
Ref. Description SDV30
34. Door, Right - Stardance Refer to Enamel Parts Chart Page 38
35. Door, Left - Stardance Refer to Enamel Parts Chart Page 38
36. Sensor 1450 CMG-8184-0032 10002013
37. Draft Hood Final Assembly (not shown) 20005228
38. Gasket, HE Door 1203687
39. Left End Refer to Enamel Parts Chart Page 38
40. Right End Refer to Enamel Parts Chart Page 38
41. Transmitter Honeywell RF 20002047
42. FK26 Fan Subassembly (RF only) 30000879
43. Switch Bracket (not shown) 53821
44. Starter Pipe (not shown) 30000245
45. Rear Shroud (not shown) 20003802
46. 2
47. 1/4” Fiberglass Gasket 1203560
48a. Valve Nova SIT820.662 RN (Serial #’s starting with 8738) 20010563 48b. Valve Nova SIT820.653 RP (Serial #”s starting with 8738) 20010645
49. Ignitor Piezo w/Nut SIT 52464
50. Bracket Piezo Ignitor (not shown) 20010876
¹⁄₄” Restrictor (not shown) 1409170
Fuel Conversion Kits
Conversion Kit, NG to LP - JDV/SDV30R Kit #000-5022 Conversion Kit, NG to LP - SDV30RFN (DB) Kit #000-5012 Conversion Kit, LP to NG - JDV/SDV30R Kit #000-5021 Conversion Kit, LP to NG - SDV30RFP (DB) Kit #000-5011
Shell Enamel Part Numbers Color Top Left End Right End Front OP Left Door Right Door Classic 30001276 30001280 30001279 30001496 30001139 30001138 Biscuit 30003305 30003300 30003301 30003302 30003304 30003303 Bordeaux 30001283 30001287 30001286 30001261 30001263 30001262 Chestnut Brown 30003313 30003308 30003309 30003310 30003312 30003311 Ebony 30001304 30001308 30001307 30001270 30001272 30001271 Forest Green 30001290 30001294 30001293 30001264 30001266 30001265 Midnight Blue 30001317 30001321 30001320 30001314 30001316 30001315 Sand 30001297 30001301 30001300 30001267 30001269 30001268 Suede Brown 30002549 30002547 30002548 30002550 30002552 30002551 Vermont
Classic Green 30003321 30003316 30003317 30003318 30003320 30003319
38
20007065
Stardance Direct Vent/Natural Vent Gas Heater
Optional Accessories
Fan Kits
FK26 Fan
The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem­perature rises above and falls below a preset tempera­ture. A rheostat provides for variable fan speeds.
Specifications
115 Volt / 60Hz / .75 Amps
Maintenance
The fan itself does not require regular maintenance, however, periodic cleaning of the fan and the surround­ing area is required.
Installation
Refer to Page 13 for installation instructions.
Remote Controls
The remote control allows you to turn the heater on or off from anywhere in the room. Refer to Page 40 for wir­ing diagrams. These remotes for use with RN/RP model gas stoves.
Model Functions Controlled RC1 ON/OFF
RC2 ON/OFF and Temperature IMTFK Wall mounted thermostat control
Screen Kit
An optional screen, S30SK, for use with the operable doors is available to allow the doors to be left in the open position.
Warming Shelf
Warming shelves add versatility to your stove; they can be used to keep foods warm at mealtime.
Model Color 2702 Classic Black
2684 Biscuit 2685 Chestnut Brown 2688 Vt. Classic Green 2704 Bordeaux 2706 Forest Green 2764 Sand 2765 Ebony 2711 Midnight Blue 2712 Suede Brown
The shelf installation is done in three stages. First you attach the shelf loosely to the stove, leaving the screws loose enough to allow final adjustments. Then, you po­sition the shelf and adjust the brackets so the shelf fits correctly. Finally, you tighten the screws. Refer to the instructions included with each warming shelf for complete installation procedures.
Decorative Rings
7” brass or charcoal gray rings are available to add a decorative touch to the exposed stove pipe.
Model Description 7FSDRG/4 7” Charcoal Gray Rings (4)
7FSDRP/4 7” Polished Brass Rings (4)
20007065
39
Stardance Direct Vent/Natural Vent Gas Heater
40
20007065
Stardance Direct Vent/Natural Vent Gas Heater
20007065
41
Stardance Direct Vent/Natural Vent Gas Heater
LIMITED LIFETIME WARRANTY
PRODUCT COVERED BY THIS WARRANTY
All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.
BASIC WARRANTY
CFM Corporation (hereinafter referred to collectively as the Company)
warrants that your new Vermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
EXTENDED LIFETIME WARRANTY
The heat exchanger, where applicable, and combustion chamber
of every Vermont Castings or Majestic gas product is warranted for life against through wall perforation. All appliances equipped with an Insta-Flame Ceramic Burner have limited lifetime coverage on the ceramic burner plaque. Warrantees are made to the original owner subject to proof of purchase and the conditions and limitations listed on this Warranty Document
COMPONENT WARRANTY
CAST IRON: All external and internal cast iron parts are warranted for a period of three years.
Note: On porcelain enamel finished external parts and accessories
The Company offers no Warranty on chipping of enamel surfaces. Inspect all product prior to accepting it for any damage to the enamel.
The salt air environment of coastal areas or a high humidity
environment can be corrosive to the porcelain enamel finish. These conditions can cause rusting of the cast iron beneath the porcelain enamel finish, which will cause the finish to flake off.
Dye lot variations with replacement parts and/or accessories can
occur and are not covered by warranty.
GLASS DOORS: Glass doors are covered for a period of one year. Glass doors are not warranted for breakage due to misuse or accident. Glass doors are not covered for discoloration or burned in stains due to environmental issues, or improper cleaning and maintenance.
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be cleaned with Lemon oil only. mix and masonry cleaners may corrode the brass finish. The Company will not be responsible for, nor will it warrant any brass parts which are damaged by external chemicals or down draft conditions.
GAS VALVES: Gas valves are covered for a period of one year ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and
mechanical components of the burner assembly are covered for one year. All steel tube burners are warranted for one year.
ACCESSORIES: Unless otherwise noted all components and CFM Corporation company supplied accessories are covered for a period of one year.
CONDITIONS AND LIMITATIONS
• This new Vermont Castings or Majestic product must be installed by
a competent, authorized, service contractor. A licensed technician, as prescribed by the local jurisdiction must perform any installation/service work. It must be installed and operated at all times in accordance with the Installation and Operating instructions furnished with the product. Any alteration, willful abuse, accident, or misuse of the product shall nullify this warranty.
• This warranty is non-transferable, and is made to the original owner,
provided that the purchase was made through an authorized supplier of the Company.
• The customer must pay for any Authorized Dealer in-home travel fees
or service charges for in-home repair work. It is the dealers option whether the repair work will be done in the customer’s home or in the dealer’s shop.
• If upon inspection, the damage is found to be the fault of the
manufacturer, repairs will be authorized at no charge to the customer parts and/or labor.
Brass cleaners cannot be used. Mortar
42
• Any part and/or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty, whichever is longest.
• This warranty is limited to the repair of or replacement of part(s) found to be defective in material or workmanship, provided that such part(s) have been subjected to normal conditions of use and service, after said defect is confirmed by the Company’s inspection.
• The company may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of the defective part(s)
• Any installation, labor, construction, transportation, or other related costs/expenses arising from defective part(s), repair, replacement, or otherwise of same, will not be covered by this warranty, nor shall the Company assume responsibility for same. Further, the Company will not be responsible for any incidental, indirect, or consequential damages except as provided by law.
SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
• All other warranties-expressed or implied- with respect to the product, its components and accessories, or any obligations/liabilities on the part of the Company are hereby expressly excluded.
• The Company neither assumes, nor authorizes any third party to assume on its behalf, any other liabilities with respect to the sale of this Vermont Castings or Majestic product
• The warranties as outlined within this document do not apply to chimney components or other non CFM Corporation accessories used in conjunction with the installation of this product..
• Damage to the unit while in transit is not covered by this warranty but is subject to claim against the common carrier. Contact the dealer from whom you purchased your fireplace/stove (do not operate the appliance as this might negate the ability to process the claim with the carrier).
• The Company will not be responsible for: a) Down drafts or spillage caused by environmental conditions such
as near-by trees, buildings, roof tops, hills, or mountains.
b) Inadequate ventilation or negative air pressure caused by
mechanical systems such as furnaces, fans, clothes dryers, etc.
• This warranty is void if: a) The fireplace has been operated in atmospheres contaminated by
chlorine, fluorine, or other damaging chemicals.
b) The fireplace has been subjected to prolonged periods of
dampness or condensation
c) Any damages to the fireplace, combustion chamber, heat
exchanger or other components due to water, or weather damage, which is the result of but not limited to, improper chimney/venting installation.
d) Any alteration, willful abuse, accident, or misuse of the product
has occurred.
IF WARRANTY SERVICE IS NEEDED…
1) Contact your supplier. Make sure you have your warranty, your sales receipt, and the model/serial number of your CFM Corporation product.
2) DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.
20007065
GARANTIE À VIE LIMITÉE
PRODUIT COUVERT PAR LA PRÉSENTE GARANTIE
L’ensemble des cuisinières à gaz, des poêles encastrables et des foyers à gaz Vermont Castings, ainsi que l’ensem­ble des foyers à gaz de marque Majestic équipés d’un brûleur en céramique Insta-Flame ou d’un brûleur en acier standard.
GARANTIE DE BASE
La société CFM Corporation (ci-après la « Société ») garantit votre
nouveau poêle/foyer au gaz Vermont Castings ou Majestic contre tous défauts de fabrication et de matières premières pour une période d’un an à compter de la date d’achat, sous réserve des conditions et limitations suivantes.
GARANTIE À VIE PROLONGÉE
L’échangeur de chaleur, s’il y a lieu, ainsi que la chambre à com
bustion de tout produit à gaz de la société Vermont Castings ou Majestic sont garantis pour la vie contre la perforation des parois. Tous les produits équipés d’un brûleur en céramique Insta-Flame comprennent une garantie à vie limitée de la plaque du brûleur en céramique. Les garanties sont accordées à l’acheteur d’origine, le tout sujet à une preuve d’achat et aux conditions et limitations suivantes :
GARANTIE DES COMPOSANTS
FONTE : Toutes les pièces en fonte externes et internes sont garanties pour une période de trois ans. Nota : Dans le cas des pièces et accessoires externes au fini en émail
de porcelaine, la Société n’offre aucune garantie quant à l’écaillage des surfaces en émail. Avant d’accepter un produit, inspectez-le afin de vous assurer que les surfaces en émail ne sont pas endomma­gées.
L’atmosphère saline des zones côtières ou les environnements à
forte humidité peuvent provoquer la corrosion du fini en émail de porcelaine. Ces conditions peuvent également faire rouiller la fonte sous le fini en émail de porcelaine, provoquant ainsi l’écaillement de la couche de fini.
Dans le cas des pièces et (ou) des accessoires de remplacement,
les variations de lots de teinture sont possibles, mais elles ne sont
pas couvertes par la garantie. PORTES EN VERRE : Les portes en verre sont couvertes pour une période d’un an. Les portes en verre ne sont pas garanties contre le bris causé par un mauvais usage ou un accident. Les portes en verre ne sont pas couvertes contre la décoloration ni contre les taches imprégnées attribuables à des conditions environnementales ou à un nettoyage et un entretien inadéquats. PIÈCES ET ACCESSOIRES PLAQUÉS EN LAITON : Les pièces en laiton ne doivent être nettoyées qu’avec de l’essence de citron. Les nettoyants pour le laiton ne doivent pas être utilisés, et les agents net­toyants pour le mortier et la maçonnerie peuvent provoquer la corrosion du fini laiton. La Société ne pourra être tenue responsable des domma ges à toute pièce en laiton occasionnés par des conditions chimiques externes ou le refoulement, et elle n’offre aucune garantie à cet égard. SOUPAPES À GAZ : Les soupapes à gaz sont couvertes pour une période d’un an. COMPOSANTS ÉLECTRONIQUES ET MÉCANIQUES : Les compo sants électroniques et mécaniques du brûleur sont couverts pendant un an. Tous les brûleurs en acier sont garantis pendant un an. ACCESSOIRES : À moins d’indication contraire, tous les composants et accessoires fournis par CFM Corporation sont couverts pendant une période d’un an.
CONDITIONS ET LIMITATIONS
• Ce nouveau produit Vermont Castings ou Majestic doit être installé
par un entrepreneur de service autorisé et compétent. L’installation/le service doivent être assurés par un technicien breveté, conformé­ment à la juridiction locale. Le produit doit être installé et utilisé en tout temps selon les instructions d’installation et de fonctionnement fournies avec le produit. Toute altération ou tout abus volontaire, accident ou mauvais usage du produit annulera cette garantie.
• Cette garantie n’est pas transférable et est offerte à l’acheteur
d’origine, à condition que l’achat ait été effectué par l’entremise d’un détaillant autorisé de la Société.
• Le client doit assumer les frais de déplacement à domicile de tout
détaillant autorisé ou les frais de service relatifs à toute réparation effectuée à domicile. Le détaillant peut à son choix effectuer les réparations chez le client ou à son atelier.
• Si, lors de l’inspection, on constate que les dommages sont la faute
20007065
-
-
Stardance Direct Vent/Natural Vent Gas Heater
du fabricant, les réparations, les pièces et la main-d’œuvre seront autorisées sans frais pour le client.
• Toute pièce et (ou) tout composant remplacé en vertu des dispo sitions de la présente garantie est couvert pour une période de six mois ou jusqu’à l’expiration de la garantie originale, selon la dernière des éventualités à survenir.
• Cette garantie est limitée à la réparation ou au remplacement de toute pièce trouvée défectueuse en matières premières ou main-d’oeuvre, à condition que ladite pièce ait été sujette aux con­ditions normales d’usage et de service, après que ledit défaut a été confirmé par une inspection par la Société.
• La Société peut, à sa discrétion, se décharger entièrement de toutes obligations se rapportant à cette garantie en remboursant le prix de gros de toute pièce défectueuse.
• Tous les frais/dépenses d’installation, de main-d’oeuvre, de cons­truction, de transport ou autres causés par toute pièce défectueuse, une réparation, un remplacement ou autre, ne seront pas couverts en vertu de la présente garantie, et la Société n’assume aucune responsabilité pour ceux-ci. De plus, la Société ne pourra être tenue responsable de tous dommages fortuits ou indirects, sauf là où prévu par la loi.
• CERTAINS PROVINCES NE PERMETTENT PAS L’EXCLUSION OU LES LIMITATIONS RELATIVES AUX DOMMAGES CONSÉCU­TIFS OU INDIRECTS QUANT À LA DURÉE DE TOUTE GARANTIE IMPLICITE, SI BIEN QU’IL EST POSSIBLE QUE LES LIMITATIONS CI-DESSUS NE S’APPLIQUENT PAS DANS VOTRE CAS. LA PRÉ­SENTE GARANTIE VOUS DONNE DES DROITS SPÉCIFIQUES, ET IL EST POSSIBLE QUE VOUS AYEZ D’AUTRES DROITS QUI PEUVENT VARIER D’UN ÉTAT À L’AUTRE.
• Toute autre garantie, expresse ou implicite, en ce qui a trait au pro duit et ses composants et accessoires, ou toute obligation/responsa­bilité de la part de la Société sont expressément exclues en vertu des présentes.
• La Société n’assume et n’autorise personne à assumer, en son nom, toute responsabilité en ce qui a trait à la vente de ce produit Vermont Castings ou Majestic.
• Les garanties, telles qu’elles sont décrites dans le présent document, ne s’appliquent pas aux composants de cheminée ni à d’autres ac­cessoires CFM Corporation utilisés conjointement avec l’installation de ce produit.
• Les dommages causés à l’unité tandis qu’elle est en transit ne sont pas couverts par la présente garantie, mais pourront être l’objet d’une réclamation contre le transporteur général. Communiquez avec le détaillant chez qui vous avez acheté votre foyer/poêle (n’utilisez
­pas l’appareil étant donné que cela pourrait annuler toute réclamation contre le transporteur).
• La Société n’engagera aucune responsabilité quant : a) au refoulement de cheminée ou débordement causé par les
conditions environnementales (arbres, édifices, toits, coteaux ou montagnes adjacents);
b) à une ventilation inadéquate ou une pression d’air négative
causée par des systèmes mécaniques comme les fournaises, les ventilateurs, les sécheuses, etc.
• Cette garantie est nulle si : a) le foyer a été utilisé dans une atmosphère contaminée par du
chlore, du fluor ou tout autre produit chimique;
b) le foyer est assujetti à de longues périodes d’humidité ou de
condensation;
c) des dommages sont causés au foyer, à la chambre de combus-
tion, à l’échangeur de chaleur ou aux autres composants par de l’eau ou par la température qui est le résultat mais sans y être limité, d’une mauvaise installation de cheminée/ventilation;
d) toute altération ainsi que tout abus volontaire, accident ou mau
vais usage du produit annule la présente garantie.
SI UN SERVICE SOUS GARANTIE EST REQUIS…
1) Communiquez avec votre détaillant. Assurez-vous que vous avez votre garantie, votre reçu de caisse ainsi que le numéro de modèle/ série de votre produit CFM Corporation.
2) NE TENTEZ PAS D’EFFECTUER DES RÉPARATIONS VOUS­MÊME.
-
-
-
43
Efficiency Ratings
Model EnerGuide Ratings Fireplace Efficiency (%)
SDV30RN 63.0 SDV30RP 63.0 SDV30RFN 63.0 SDV30RFP 63.0
CFM Corporation
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6
800-668-5323 • www.cfmcorp.com