INSTALLER / CONSUMER SAFETY INFORMATION

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE.

WARNING!

IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY

Installation and service must be performed by a qualified installer, service agency or the gas suppler.

WHAT TO DO IF

YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from your neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

DO NOT STORE OR USE

GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

This appliance may be installed in an after market permanently located manufactured (mobile) home where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate.

This appliance is not convertible for use with other gases unless a certified kit is used.

Radiance

Direct Vent Gas Heater

Models:

RADVT Series: RADVTCB, RADVTEB, RADVTMB,

RADVTBS, RADVTCH, RADVTVG, RADVTBD, RAD-

VTBB, RADVTCG, RADVTGG, RADVTSG,

RADVTC Series: RADVTCCB, RADVTCEB,

RADVTCMB, RADVTCBS, RADVTCCH, RADVTCVG,

RADVTCBD, RADVTCBB, RADVTCCG, RADVTCSG

Homeowner’s Installation

and Operating Manual

 

S

 

E IG

N

D

 

CERTIFIED

C

D

E

 

RTIFIE

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

20012697 8/07 Rev. 1

Radiance Direct Vent Gas Heater

 

 

Table of Contents

 

PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.

Thank you and congratulations on your purchase of a Vermont Castings stove.

 

IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions

may result in a possible fire hazard and will void the warranty.

 

Installation &

General Information ....................................................................................................

3

Operating Instructions

Stove Dimensions .......................................................................................................

4

 

Installation Requirements ...........................................................................................

5

 

Locating the Stove ......................................................................................................

5

 

Clearance Requirements ............................................................................................

5

 

Parallel Installation ......................................................................................................

6

 

Corner Installation .......................................................................................................

6

 

Wall and Ceiling Clearances .......................................................................................

6

 

Hearth Requirements ..................................................................................................

6

 

Gas Specifications ......................................................................................................

7

 

Gas Inlet and Manifold Pressures ...............................................................................

7

 

High Elevations ...........................................................................................................

7

 

Horizontal Termination ................................................................................................

7

 

Vertical Termination .....................................................................................................

8

 

Restrictor Plate Adjustment for Extended Pipe Runs ..................................................

8

 

Vent Termination Clearances ......................................................................................

9

 

General Venting Information - Termination Location .................................................

10

 

Termination Clearances ............................................................................................

11

 

Venting Requirements and Options ..........................................................................

12

Assembly Procedures

Tools Required ..........................................................................................................

14

 

Parts Bag Contents ...................................................................................................

14

 

Unpack and Assemble Legs ......................................................................................

14

 

Install Optional Fan ...................................................................................................

15

 

Venting System Assembly - Direct Vent ....................................................................

16

 

Install Vent Adapter Pipe (CFM Corporation Components) ......................................

16

 

Install Vent Adapter Pipe (Simpson Dura-Vent Components) ...................................

16

 

Install Vent Adapter Pipe (Selkirk Corporation Components) ....................................

17

 

Side Wall Termination Assembly ...............................................................................

17

 

Vent Termination Below Grade .................................................................................

19

 

Vertical (Through the Roof) Vent Assembly ..............................................................

19

 

Selkirk Direct-Temp Metalbestos Direct Vent System................................................

20

 

Install Log Set............................................................................................................

25

 

Connect Gas Supply Line .........................................................................................

27

 

Burner Information ....................................................................................................

27

 

Install ON/OFF Switch ..............................................................................................

28

 

Thermostat Connection (Optional) ............................................................................

28

 

Install the Mesh and Grille ........................................................................................

28

Operation

Your First Fire ...........................................................................................................

28

 

Pilot and Burner Inspection .......................................................................................

28

 

Flame & Temperature Adjustment .............................................................................

29

 

Flame Characteristics ...............................................................................................

29

 

Lighting and Operating Instructions ..........................................................................

30

 

Troubleshooting - SIT NOVA 820 (RADVT Series) ...................................................

31

 

Instructions for RF Comfort Control Valve ................................................................

32

 

Fuel Conversion Instructions ....................................................................................

36

Maintenance

Annual System Inspection ........................................................................................

40

 

Logset and Burner/Cleaning and Inspection .............................................................

40

 

Care of Cast Iron .......................................................................................................

40

 

Cleaning the Glass ...................................................................................................

40

 

Glass Replacement ...................................................................................................

40

 

Gasket Replacement ................................................................................................

41

 

Inspect the Vent System Annually ............................................................................

41

 

Check the Gas Flame Regularly ...............................................................................

41

 

Wiring Diagrams .......................................................................................................

42

Replacement Parts

...................................................................................................................................

43

Optional Accessories

...................................................................................................................................

47

Warranty

...................................................................................................................................

51

22

20012697

Radiance Direct Vent Gas Heater

Installation & Operating Instructions

The Radiance Direct Vent Room Heater, Model Nos. RADVTCB, RADVTEB, RADVTMB, RADVTBS, RADVTCH, RADVTVG, RADVTBD, RADVTBB, RADVTCG, RADVTGG, RADVTSG, RADVTCCB, RADVTCEB, RADVTCMB, RADVTCBS, RADVTCCH,RADVTCVG,RADVTCBD,RADVTCBB,RADVTCCG, RADVTCSG, is a vented gas appliance listed to the ANSI standard Z21.88-2005 and CSA-2.33-2005 for Vented Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use at High Altitudes.

The installation of the Radiance Direct Vent Room Heater must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest edition and CSAB-149.1 Installation Code. (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5 inches w.c. for Natural Gas and 10 inches w.c. for LP gas at maximum input.)

In the Commonwealth of Massachusetts:

All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.

A carbon monoxide detector must be installed in the same room as the fireplace. (Refer to Regulation 248CMR 4.00 & 5.00 for more information.)

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

Installation and replacement of gas piping, gas utilization equipmentoraccessories,andrepairandservicingofequipmentshallbeperformedonlybyaqualifiedagency,preferably NFIorWETT(Canada)certified. Theterm“qualifiedagency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) installation or replacement of gas piping, or (b), the connection, installation, repair, or servicing of equipment, who is experienced in such work, familiar with all precautions required, and has complied with all the requirements of the authority having jurisdiction.

TheRadianceDirectVentRoomHeatershouldbeinspected before use and at least annually by a qualified service agency. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean.

The Radiance Direct Vent Room Heater and its individual shut-off valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The Radiance Direct Vent Room Heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.

An accessible tap is located above the pilot/On-Off knob for checking the inlet pressure.

‘Direct Vent’ describes a sealed combustion system in which incoming outside air for combustion and outgoing exhaust enter and exit through two separate concentric passages within the same sealed vent system. The system does not use room air to support combustion. The Direct Vent system permits the gas appliance to be vented directly to the outside atmosphere through the side of the house or vertically through the roof.

Conventional venting systems (Natural Vent) take air from the room for combustion and vent the exhaust vertically through the roof to the atmosphere.

This appliance is approved for bedroom installations in the U.S. and Canada.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.

The Radiance Direct Vent Room Heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, (latest edition), or of the current Canadian Electrical Code C22.1.

Due to high temperatures this appliance should be located out of traffic and away from furniture and draperies.

WARNING: This appliance is hot while in operation. Keep children, clothing, and furniture away. Contact may cause burns or ignition of combustible materials.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance.

Clothing or other flammable materials should not be placed on or near the appliance.

Any safety screen, glass or guard removed for servicing an appliance must be replaced prior to operating the appliance.

The appliance area must be kept clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

The flow of combustion and ventilation air must not be obstructed.Theinstallationmustincludeadequateaccessibility and clearance for servicing and proper operation.

WARNING: Do not operate the Room Heater with the glass panelremoved,crackedorbroken.Replacementofthepanel should be done by a licensed or qualified service person.

Do not use this appliance if any part has been under water. Immediatelycallaqualifiedservicetechniciantoinspectthe appliance and to replace any part of the control system and any gas control which has been under water.

Do not burn wood, trash or any other material for which this appliance was not designed. This appliance is designed to burn either natural gas or propane only.

Thisgasappliancemustnotbeconnectedtoachimneyflue serving a separate solid-fuel burning appliance.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

* Aftermarket: Completion of sale, nor for purpose of resale, from the manufacturer.

20012697

3

Radiance Direct Vent Gas Heater

Radiance Direct Vent Stove Dimensions

See Page 6 for Flue Collar

 

7" Outer Dia.

 

7" Outer Dia.

Centerline Dimensions.

14 "

(178 mm)

14 "

(178 mm)

Supply Inlet

Supply Inlet

 

(378 mm)

(378 mm)

 

 

 

4 "

 

9 "

4 "

8 "

Flue Collar C(120 mm)

 

C(120 mm)

 

(241 mm)

(218 mm)

L

 

 

L

 

 

 

Flue Collar

 

RADVT Models

13 ”

RADVTC Models

11”

 

 

(340 mm)

 

(279 mm)

 

 

 

 

 

29 "

 

 

 

 

(758 mm)

 

 

 

 

 

 

RADIANCE

 

 

 

28"

 

 

 

(711 mm)

Supply

 

 

 

 

 

 

 

 

Inlet

 

 

 

5"

 

 

 

 

(127 mm)

 

 

31"

 

18 "

 

 

 

(464 mm)

 

 

(787 mm)

 

 

 

 

 

 

Fig. 1 Radiance dimensions.

 

 

 

 

Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

Radiance Direct Vent

Certified to:

ANSI Z21.88-2005 / CSA 2.33-2005

Vented Gas Fireplace Heaters

44

20012697

Radiance Direct Vent Gas Heater

Installation Requirements

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5” w.c. for Natural Gas, and 10” w.c. for Propane).

In Canada, installation must be in accordance with the current CSA B-149.1 Installation Codes and/or local codes.

The installation should be done by a qualified service person who is familiar with the building codes and installation techniques appropriate for your area to accomplish a safe and effective installation.

Your dealer or your local gas supplier will be able to refer a qualified service person.

WARNING: Due to high temperatures, the HEATER should be located out of traffic and

away from furniture and draperies.

The surface of the Heater Is hot when it is in use. Young children should be watched carefully when they are in the same room when the Heater is in use, and they should be taught to avoid the hot surface. Keep any objects that can burn well away from the Heater, and observe the recommended clearances that follow.

Locating The Stove

In choosing a location for the stove, consider:

The location of outside walls;

Where additional heat is needed:

Where family members gather most often;

The vent system requirements.

NOTE: We do not recommend the use of wallpaper next to this stove. Over time, radiant heat may cause the wallpaper to shrink, or may adversely affect the binders in the wallpaper adhesive.

Direct Vent System Only

A D

B

C

E

A. Flat on corner wall

D. Cross Corner

B. Room Divider

E. Flat on wall

C. Island

ST207a

Fig. 2 Possible stove locations.

Clearance Requirements

Minimum Clearances to Combustible Materials

Measure side clearances as shown in Figures 3, 4 and 5 from the outer edge of the cast iron stove top. Measure rear clearances from the outermost surface of the steel rear skirt.

The Radiance heater is approved for installation into an alcove constructed of combustible materials to the dimensions and clearances shown on the next page.

The same clearances apply in a standard parallel installation.

WARNING:

• Always maintain required clearances (air spaces) to nearby combustibles to prevent fire hazard. Do not fill air

spaces with insulation. All venting components must maintain a 1” (25mm) clearance to combustible materials. Maintain a 6” (150mm) clearance when using single wall pipe.

The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas-burning appliance.

Refer to the manufacturer’s instructions included with the venting system for complete installation procedures.

20012697

5

Radiance Direct Vent Gas Heater

Parallel Installation:

Minimum Clearance and Flue Centerline

42" (1070mm)

Min. Alcove Width

4" (102mm)

48"

(1220mm) Max. Alcove Depth

 

 

 

6"

 

 

 

6"

 

 

 

 

 

 

 

 

 

 

 

ST130

(150mm)

 

 

(150mm)

 

 

 

 

 

 

 

 

 

Fig. 3 Parallel installation, minimum back and side clearances, and flue centerlines.

Corner Installation:

Minimum Clearance and Flue Centerline

18" (457mm)

6"(150mm)

18"

(457mm)

6"

(150mm)

ST129

Fig. 4 Corner installation, minimum corner clearances and flue centerline.

Wall Centerline from Floor

Direct Vent Only

A

ST131b

A

Effective Minimum

Centerline 57” (1448 mm) (CFM Corporation Pipe) 55” (1399 mm) (Simpson DuraVent Pipe)

Fig. 5 Minimum wall centerline.

Wall and Ceiling Clearances

Direct Vent Only

D

B

 

C

 

 

A

A: Rear Wall

4” (102 mm)

B: Min. Clearance

44” (1118 mm)*

C: Min. Alcove Height

72” (1830 mm)*

D: Max. Alcove Depth

48” (1220 mm)

Sidewall Clearance

6” (150 mm)

* needed for installing DuraVent Minimum Vent Kit #2792 or

 

CFM Corporation Minimum Vent Kit #7TFSMSK.

ST101b

 

Fig. 6 Dimensions and clearances to ceiling or alcove.

Hearth Requirements

The Radiance Heater must be installed on rigid flooring.

When the heater is installed directly on any combustible surface other than wood flooring, a metal or wood panel extending the full width and depth of the unit must be used as the hearth. There are no other hearth requirements.

66

20012697

Gas Specifications

 

 

 

Max.

Min.

 

 

 

Input

Input

Model

Fuel

Gas Control

BTU/h

BTU/h

RADVT Series

Nat

Millivolt

38,000

25,000

RADVT Series

Prop

Millivolt

36,000

25,000

RADVTC Series

Nat

Comfort Control

38,000

25,000

RADVTC Series

Prop

Comfort Control

36,000

25,000

Weight: Fully assembled; 350 lbs.

Gas Inlet and Manifold Pressures

 

Natural

LP (Propane)

Inlet Minimum

5.5” w.c.

11.0” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10” w.c.

The installation of your Vermont Castings stove must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, or CSA B149.1 Installation code. (EXCEPTION: Do not derate this appliance for altitude up to 2,000 (610 m) for natural gas and 4,500 feet (1,370 m) for LP Gas. Maintain the manifold pressure at 3.5” w.c. for Natural Gas and 10.0” w.c. for LP Gas.

High Elevations

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 2,000 feet (610 m) for natural gas and 4,500 feet (1,370 m) for LP gas above sea level.

In the USA installations with elevations above 2,000 feet (610 m) for natural gas and 4,500 feet (1,370 m) for LP gas must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 2,000 feet (610 m) for natual gas and 4,500 feet (1,370 m) for LP gas.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

Radiance Direct Vent Gas Heater

Horizontal Termination

The vent must rise vertically a minimum of 24” (610mm) off the top of the unit, before the first elbow. The horizontal run may extend up to 20’ (6m) and include a vertical rise of up to 40’ (12m). (Fig. 7) Horizontal termination must also meet the criteria shown in Figures 10 through 12.

Approved vent systems must terminate above and including the heavy line in Figure 7.

Two 45˚ elbows may be substituted for each single 90˚ elbow.

With a rise between 2’ - 5’, one 90˚ or two 45˚ elbows may be used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pipe.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

vent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

top

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

feet)(inRunVertical collarflueappliancetheto the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

May

use

up

to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

three 90°

Elbows

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Measured

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

One

90°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Elbow

 

 

 

 

 

 

 

Unacceptable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Venting

Configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal Run (in feet)

 

ST134a

Fig. 7 Horizontal vent termination window.

20012697

7

Radiance Direct Vent Gas Heater

Vertical Termination

A vertical vent system must terminate no less than 8’ (2.44 m) and no more than 40’ (12 m) above the appliance flue collar. A restrictor plate (supplied) must be used, where specified, in all vertically terminated vent systems. (Refer to Figure 8) NOTE: The restrictor plate supplied with the vertical termination should be discarded. Adjust the restrictor plate according to recommendations in Figure 10. A vertically terminated vent system must also conform to the following criteria:

No more than three 90° elbows may be used.

Two 45° elbows may be substituted for one 90˚ elbow. No more than six 45° elbows may be used.

Vent must rise a minimum of 2 feet (305 mm) before offset is used.

Termination height must conform to roof clearance as specified in Figure 11.

 

 

All Vertical Termi-

 

 

 

 

nations in this area

 

 

 

 

 

 

pipe.)

 

Require use of the

 

 

 

Restrictor Plate*

 

 

vent

 

 

 

 

 

 

 

the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of

 

 

 

 

 

 

 

 

 

 

 

 

 

top

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tothe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

collar

 

 

 

 

 

 

 

(infeet) flue

 

 

 

 

 

 

 

 

Vertical terminations

 

 

appliance

 

must be within this area

 

 

 

 

 

 

 

 

 

Run

 

 

 

 

 

 

 

Vertical the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Measure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unacceptable

 

 

 

 

 

 

Venting Configuration

 

 

 

 

 

Plate

 

 

 

 

 

Restrictor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No offset may be used

 

 

 

 

 

 

 

 

 

 

 

 

within this area

 

 

 

 

 

 

 

 

 

 

Horizontal Run (in feet)

 

ST132a

Fig. 8

Vertical vent termination window.

 

 

*The Restictor Plate is used on Direct Vent installations only.

Restrictor Plate Adjustment

for Extended Pipe Runs

The Radiance stove is shipped with a restrictor plate in the Parts Bag. Adjustments can be made by loosening the adjustment screw to allow the restrictor plate to slide up or down. (Fig. 9) A guide for usage is shown in

Figure 10.

NOTE: Some installations may require some adjustment by the installer for optimum flame appearance.

Optimum flame appearance is a flame that is not subject to tall, dirty yellow flames producing soot or flames lifting off of the ember bed ports.

Restrictor Plate Adjustment

1.Remove the screw in the back wall of the firebox.

2.Install restrictor plate as shown in Figure 9 with cut out on left side. Secure with adjustment screw.

2.Measure from center of screw to top edge of diverter (Fig. 9) to adjust plate according to guidelines in Figure 10.

3.Tighten attachment screw.

4.Install logs following log installation instructions.

AdjustmentScrew

ST917

Fig. 9 Loosen screw to adjust restrictor plate.

Examples for Extended Run/Restrictor Plate Settings

1.Vertical 20’ (6 m), 90° elbow, out 8’ (2.4 m)

2.Vertical 11’ (3.4 m), 90° elbow, out 2’ (610 mm)

3.Vertical 40’ (12 m)

4.Vertical 5’ (1.5 m), 90° elbow, out 5’ (1.5 m)

Restrictor plate measurement from top of plate to center of screw:

1.2³⁄ ” (70 mm) from center of screw to top edge of plate

2.Plate down to top of slot

3.Plate down to top of slot

4.2³⁄ ” (60 mm) from center of screw to top edge of plate

Figure 10

88

20012697

Radiance Direct Vent Gas Heater

Vent Termination Clearances

When planning the installation, consider the location of the vent terminal and clearances. Some of the most common clearances to keep in mind are shown in Figure 11.

Important: All vent clearances must be maintained. Check your vent termination clearances against Figures 11 through 13.

The vent should be placed so that people cannot be burned by accidentally touching the vent surfaces when the stove is operating.

The vent termination should be located where it cannot be damaged by such things as automobile doors, lawn mowers or snowblowers and it should be located away from areas where it could become blocked by snow, etc.

Some considerations are:

Obstructions or impediments to venting.

Nearby combustible materials that could come into contact with combustion exhaust gases.

Other nearby openings {within 12” (305 mm)} through which exhaust gas could reenter the building.

All vegetation within 3’ (76 mm) that may interfere with the draft.

Other factors that influence where the installation will be sited include the location of outside walls, where additional heat may be desired in the home, where the family members gather most regularly, and perhaps most importantly, the distance limitations of the venting system.

IMPORTANT

The horizontal termination must not be recessed into the exterior wall or siding.

Horizontal vent runs must be level toward the vent termination.

Clearances around the vent termination must be maintained.

For installations using Simpson DuraVent pipe, parallel installations with minimum wall clearance have restricted access for connecting the Horizontal Vent Cap straps to the vent pipe. See the maker’s instructions for recommended installation procedures.

Your stove is approved to be vented either through the side wall, or vertical through the roof.

CFM Corporation does not require any opening for inspection of vent pipe.

Only CFM Corporation, Simpson DuraVent and Selkirk Corporation venting components specifically approved and labelled for this stove may be used.

Minimum clearances between vent pipes and combustible materials is one (1”) inch (25 mm), except where stated otherwise.

Venting terminals shall not be recessed into a wall or siding.

Horizontal venting must be installed on a level plane without an inclining or declining slope.

There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24” from the front of the termination hood.

Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

Location of Vent Termination

It is imperative the vent termination be located observing the minimum clearances as shown on this page.

20012697

9

Radiance Direct Vent Gas Heater

General Venting Information - Termination Location

D

E

V

L

B

CFM145a

C

V

F

V

Operable

 

B

 

INSIDE

 

 

 

CORNER DETAIL

 

 

 

G

 

 

 

V

 

N

A

H

N

 

 

 

B

BV

V Fixed

Operable Closed

 

V J X

B

M

B

 

I

V K X

 

A

 

 

 

V VENT TERMINATION X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED

 

 

 

Canadian Installations1

US Installations2

 

A =

Clearance above grade, veranda, porch,

12” (30cm)

12” (30cm)

 

 

deck, or balcony

 

 

 

B = Clearance to window or door that may be

6” (15cm) for appliances

6” (15cm) for appliances

 

 

opened

< 10,000Btuh (3kW), 12” (30cm)

< 10,000 Btuh (3kW), 9”

 

 

 

for appliances > 10,000 Btuh (3kW) and

(23cm) for appliances > 10,000

 

 

 

< 100,000 Btuh (30kW), 36” (91cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

C = Clearance to permanently closed window

12” (305mm) recommended to

12” (305mm) recommended to

 

 

 

prevent window condensation

prevent window condensation

 

D = Vertical clearance to ventilated soffit located

 

 

 

 

above the terminal within a horizontal

18” (458mm)

18” (458mm)

 

 

distance of 2’ (610mm) from the center

 

 

 

 

line of the terminal

 

 

 

E = Clearance to unventilated soffit

12” (305mm)

12” (305mm)

 

F =

Clearance to outside corner

see next page

see next page

 

G = Clearance to inside corner (see next page)

see next page

see next page

 

H = Clearance to each inside of center line

3’ (91cm) within a height of 15’ (5m)

3’ (91cm) within a height of 15’

 

 

extended above meter/regulator assembly

above the meter/regulator assembly

(5m) above the meter/regulator

 

 

 

 

assy

 

I =

Clearance to service regulator vent outlet

3’ (91cm)

3’ (91cm)

 

J =

Clearance to nonmechanical air supply inlet

6” (15cm) for appliances < 10,000

6” (15cm) for appliances

 

 

to building or the combustion air inlet to any

Btuh (3kW), 12” (30cm) for

< 10,000 Btuh (3kW), 9”

 

 

other appliances

appliances > 10,000 Btuh (3kW) and <

(23cm) for appliances > 10,000

 

 

 

100,000 Btuh (30kW), 36” (91cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

K =

Clearance to a mechanical air supply inlet

6’ (1.83m)

3’ (91cm) above if within 10’

 

 

 

 

(3m) horizontally

 

L =

Clearance above paved sidewalk or paved

7’ (2.13m)†

7’ (2.13m)†

 

 

driveway located on public property

 

 

 

M = Clearance under veranda, porch, deck or

12” (30cm)‡

12” (30cm)‡

 

 

balcony

 

 

N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450mm).

1 In accordance with the current CSA-B149 Installation Codes

2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes

† A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings

‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: NOTE: 1. Local codes or regulations may require different clearances.

2.The special venting system used on Direct Vent Stoves are certified as part of the appliance, with clearances tested and approved by the listing agency.

3.CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

Fig. 11 Vent termination clearances.

1010

20012697

Radiance Direct Vent Gas Heater

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

Inside Corner Outside Corner Alcove Applications*

 

 

 

 

C

D

 

 

 

 

C

 

 

 

 

F =

 

 

 

G =

 

Combustible

 

G

 

Combustible

 

6" (152 mm)

V

 

 

6" (152 mm)

V

Noncombustible

E

 

 

 

2" (51 mm)

 

 

Noncombustible

 

O

 

V

 

F

 

2" (51 mm)

 

 

 

 

 

Balcony -

Balcony -

 

 

 

 

with no side wall

with perpendicular side wall

E = Min. 6” (152 mm) for

 

 

 

 

 

 

non-vinyl sidewalls

 

 

 

 

Min. 12” (305 mm) for

 

 

 

vinyl sidewalls

 

 

 

 

O = 8’ (2.4 m) Min.

 

 

M

M

No.

 

 

 

V

V

of Caps

DMin.

CMax.

 

1

3’ (914 mm)

2 x DActual

 

 

P

 

 

2

6’ (1.8 m)

1 x DActual

 

M =

Combustible &

3

9’ (2.7 m)

2/3 x DActual

 

Noncombustible

4

12’ (3.7 m)

1/2 x DActual

 

Combustible &

 

M = 24" (610 mm)

 

Noncombustible

DMin. = # of Termination caps x 3

 

P = 20” (508 mm)

 

12" (305 mm)

 

 

CMax. = (2 / # termination caps) x DActual

584-15

 

 

*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap.

Fig. 12 Termination clearances.

20012697

11

Radiance Direct Vent Gas Heater

Venting Requirements and Options

Approved Vent System Components

The Radiance Heater must be vented to the outdoors through an adjacent exterior wall or through the roof. The venting system must be comprised of the appropriate listed venting components specified on this page. These parts are available from DuraVent Corporation, Selkirk Corporation or your Vermont Castings Dealer.

See Figure 4 for dimensions relevant to the standard minimum-vent kits.

Simpson DuraVent Components www.duravent.com

Phone: 1-800-835-4429, Fax: 1-707-446-4740

Minimum Horizontal Vent Kit

 

2792

Starter Pipe Assembly (incl. inner & outer sections)

2768*

90° Elbow, Blk.

46DVA-E90B*

45° Elbow, Gal.

46DVA-E45

6” Straight, Blk.

46DVA-06B*

9” Straight, Blk.

46DVA-09B

11” - 14⁄” Adjustable Straight Section

46DVA-08AB

12” Straight

 

46DVA-12

24” Straight

46DVA-24B*

36” Straight

46DVA-36B

48” Straight

 

46DVA-48

Horizontal Vent Cap

46DVA-HC*

Wall Plate

 

46DVA-DC

Vinyl Siding Shield

46DVA-VSS

Snorkel Termination - 14”

46DVA-SNK14

Snorkel Termination - 36”

46DVA-SNK30

Wall Strap

 

46DVA-WS

Cathedral Ceiling Support Box

 

46DVA-CS

Storm Collar

 

46DVA-SC

Firestop Spacer

 

46DVA-FS

Flashing 0/12 - 6/12

 

46DVA-F6

Flashing 6/12 - 12/12

46DVA-F12

Steel Chimney Conversion Kit

 

 

Kit A (6⁄” - 8⁄”)

46DVA-KCA

Kit B (6⁄” - 10¹⁄”)

46DVA-KCB

Kit C (6⁄” - 13”)

46DVA-KCC

Masonry Chimney Conversion Kit

46DVA-KMC

Vertical Termination Cap (High Wind)

46DVA-VCH

Vertical Termination Cap (Low Profile)

 

46DVA-VC

*Included in Minimum Horizontal Vent Kit #2792

All DuraVent Straight vent pipe sections have a net length 1¹⁄” (37mm) less than the nominal dimension; i.e., a 6” (152mm) Straight pipe section has an effective length of 4¹⁄” (115mm).

Selkirk Corporation Vent Components www.selkirkcorp.com

1301 W. President George Bush Highway Ste. 330 Richardson, TX 75080

Phone: 1-800-992-8368, Fax: 1-877-393-4145

Appliance Adapter

4DT-AAV

90° Elbow, Blk.

4DT-EL90B

45° Elbow, Blk.

4DT-EL45B

6” Straight, Blk.

4DT-06B

9” Straight, Blk.

4DT-09B

4” - 10” Adjustable Straight Section, Blk.

4DT-AJ12

12” Straight, Blk.

4DT-12B

18” Straight, Blk.

4DT-18B

24” Straight, Blk.

4DT-24B

36” Straight, Blk.

4DT-36B

48” Straight, Blk.

4DT-48B

Horizontal Vent Cap

4DT-HC

Wall Plate

4DT-WT

Vinyl Siding Shield

4DT-VS

Snorkel Termination - 14”

4DT-ST14

Snorkel Termination - 36”

4DT-ST36

Wall Strap

4DT-WS/B

Cathedral Ceiling Support Box

4DT-CCS

Storm Collar

4DT-SC

Firestop Spacer

4DT-FS

Flashing 0/12 - 6/12

4DT-AF6

Flashing 6/12 - 12/12

4DT-AF12

Steel Chimney

 

Horizontal Kit A

4DT-HKA

Horizontal Kit B

4DT-HKB

Vertical Kit

4DT-VKC

Masonry Chimney Kit

4DT-MCK

1212

20012697

Vertical Termination Cap

4DT-VC

CFM Vent Components

The following kits are available to meet the needs of most installations. All pipe has a 7” outer diameter and includes a 4” diameter inner section. A (CG) designation indicates the part is finished in Charcoal Gray paint. Consult your dealer about other vent parts that may be appropriate to complete the installation.

Min. Through the Wall Vent Kit

7TFSSK

(1)

90-Degree Elbow (CG)

 

(1)

24” Straight pipe (CG)

 

(1)

24” - 42” Adjustable Straight Pipe

 

(1)

Side Wall Termination

 

(1)

Firestop

 

(1)

Zero-clearance sleeve

 

(1)

Hardware package

 

(1)

Finishing plate (CG)

 

(1)

Finishing collar (CG)

 

(4)

Charcoal Gray flue pipe rings

 

Starter Kit for Below-Grade Termination

7TDVSKS

(1)

Snorkel Termination (7TDVSNORK)

 

Vertical Termination Kit, 1/12-6/12 Pitch

7TDVSKVA

(1) Combination Horizontal Offset / Roof Support

(1) Vertical Termination

(1) Storm Collar

(1) 1/12-6/12 Flashing

(1) Finishing Plate (CG)

(1) Finishing Collar (CG)

(1) Polished Brass Flue Pipe Ring

(1) Hardware Package

Vertical Termination Kit, 7/12-12/12 Pitch

7TDVSKVB

(1)

7/12 - 12/12 Flashing

 

and all of the other Vertical Termination parts.

 

Vertical Termination, Flat Roof

7DVSKVF

(1)

Flat Flashing

 

Radiance Direct Vent Gas Heater

and all of the other Vertical Termination parts.

 

Twist Lock 12” Straight Pipe (CG)

7TFSDVP12

(1)

12” Non-adjustable Pipe

 

Twist Lock 12” - 18” Adjustable Pipe

7TFSDVP1218

(1)

12” - 18” Adjustable Pipe

 

Twist Lock 24” Straight Pipe (CG)

7TFSDVP24

(1)

24” Non-adjustable Pipe

 

Twist Lock 48” Straight Pipe (CG)

7TFSDVP48

(1)

48” Nonadjustable Pipe

 

Twist Lock 45-Degree Elbow (CG)

7TFSDVT45

for vertical offsets

 

(1)

45-degree Elbow

 

Combination Offset/Roof Support

7DVCS

Attic Insulation Shield

7DVAIS

7” Charcoal Gray Pipe Rings, (4)

7FSDRG

7” Polished Brass Pipe Rings (4)

7FSDRP

Wall Thimble

942G

20012697

13

Radiance Direct Vent Gas Heater

Assembly Procedures

WARNING

Failure to position the parts in accordance with these diagrams or failure to

use only parts specifically approved for use with this heater may result in property damage or personal injury.

This heater and components are heavy. Have help available for assembly.

Tools Required

Phillips screwdriver (stub)

power drill

utility knife

reciprocating saw

metal drill bit: size 28 (.140”/3.5mm) 9/16” wrench

Parts Bag Contents:

(3) Vent Screws

(2) Switch bracket screws

Wood handle w/insert lifter (handle for operable door)

Restrictor Plate

4” Starter pipe

On-Off switch, housing, and wiring harness

(3)Phillips round-head bolts, 1/4”- 20 x 1/2”

(1) Tube of Vent Gasket Cement

(4) CS, Hex Hd 3/8-16 x 1 Gr 2-Z

(4) Washer, Fl 3/8-Z

Owner Registration Card

Homeowner’s Installation and Operating Manual

Unpack and Assemble Legs

The Radiance is shipped upright. Cut the shipping straps before beginning assembly.

1.Slide stove to the rear of the pallet just far enough to access rear leg holes. Make sure the stove does not tip over backwards. (Fig. 13)

2.Attach the rear legs using 3/8” hex head bolts and flat washer supplied. Tighten with a 9/16” wrench or socket.

3.Carefully tip the stove onto its rear legs. Adjust the pallet to allow access to one of the front leg holes. Be sure to leave the pallet under the stove to prevent the stove from falling fully forward. (Fig. 14)

CAUTION: To prevent valve tubing from being crushed or damaged, do not rest valve or ignitor on wooden pallet.

ST720

Fig. 13 Slide stove back just far enough to access rear leg holes.

 

Washer

ST721

Hex Head Bolt

 

Fig. 14 Carefully tip stove onto back legs. Leave pallet under stove to keep stove from falling fully forward.

4.Have your assistant attach one leg using the hardware described.

5.Move the pallet to allow access to the other front leg hole. Attach remaining leg.

6.Remove pallet and allow stove to gently rest on all four legs.

7.Adjust leg levelers to compensate for irregularities in the hearth.

NOTE: Verify the two relief doors (located on top of the firebox) are properly seated on the gasket. The doors should sit flush on the gasket, and should lift easily from the seal around the opening.

1414

20012697

WARNING

This appliance is equipped with a three-prong (grounded) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

Install the Optional Fan

If you are installing the optional convection Fan Kit #2767 (FK26), continue here. It is easiest to install fan kit before connecting gas line. If you are not installing a Fan Kit, go to Page 16, Venting System Assembly.

1.The fan kit includes a Blower Assembly and a Rheostat Assembly, connected by a cable. (Fig. 15) The Blower Assembly mounts to the bottom rear of the stove, and the Rheostat mounts to the valve coverplate. The assembly includes a ‘snapstat’ which automatically turns the fan On (or Off) above (or below) approximately 109˚. The Rheostat also provides a range of fan speed settings from Off (which overrides the snapstat function) to High. Unpack and inspect the Blower assembly. Confirm that the fan spins freely.

 

Not Used On

Snapstat

 

RF Models

Bracket

Not

 

Snapstat/

 

Extension

Used On

Assembly

Radiance

 

 

 

Rheostat

 

 

Assembly

 

 

Not Used

 

 

On RF

 

 

Models

Blower

 

 

Assembly

Connect to PC board on

 

 

ST473

 

RF models only

 

 

Fig. 15

Fan kit components.

 

2.Remove the rear shroud panel (Fig. 17) and fasten the blower assembly to the firebox back with the two bolts provided. (Fig. 17)

NOTE: Steps 3 and 4 do not apply to RADVTC series Comfort Control models. On these models, after attaching blower assembly to the firebox, run the spliced female leads to the front of the stove and attach to back of Honeywell valve. (Page 33, Fig. 59)

3.Attach the snapstat assembly to the snapstat bracket with two sheet-metal screws. Attach the snapstat bracket to the side shield. (Fig. 17)

4.The rheostat control switch attaches to the left side of the valve bracket at the front of the stove. (Fig. 18)

Radiance Direct Vent Gas Heater

ST147

Fig. 16 Remove rear shroud.

Side Shield

Snapstat

Bolts

ST149

Fig. 17 Attach blower assembly and snapstat.

Remove retaining nut from shaft of rheostat. (if preinstalled)

Insert the rheostat through the hole in the back of the left side of the valve bracket, aligning the locator pin with the smaller hole in that bracket.

Thread the retaining nut onto the shaft of the rheostat, tightening with a wrench. Do not overtighten.

Attach the control knob to the rheostat shaft.

Use the wire tie to secure the fan and rheostat wire harnesses together.

Rheostat

Rheostat

Retaining Collar

Rheostat Knob

ST347a

 

Fig. 18 Attach the fan rheostat.

20012697

15

Radiance Direct Vent Gas Heater

Venting System Assembly

General Information

The Radiance is approved for installation only with the vent components listed on Pages 12 and 13. Follow the vent component instructions exactly.

For U.S. installations: The venting system must conform with local codes and/or the current National Fuel Gas Code, ANSI Z223.1/NFPA 54.

For Canadian installations: The venting system must conform to the current CSA B149.1 installation code.

Install the Vent Adapter Pipe

(CFM Corporation Vent Components)

1.Attach Inner Starter Pipe, (found in the Parts Bag), to the next section of inner pipe.

Run a bead of sealant about 1/2” from the upper end of the Inner starter pipe and join the two sections together.

Drill three pilot holes into the Inner Starter and secure the assembly with three sheet metal screws. (Fig. 19)

First Section of

Vent Pipe

1/4”-20 x 1/2” Phillips Screw

4” Inner

CEMENT

Starter

 

Pipe

 

ST211

Fig. 19 Connect the inner starter with the next section of inner vent pipe.

2.Dry fit the Inner Pipe assembly to the stove for the purpose of determining the center line of the pipe on the wall.

Side Wall Terminations: Dry fit the outer elbow with the vertical outer vent and confirm the centerline alignment with the wall thimble opening.

3.Attach the Inner Vent Assembly to the stove.

Run a bead of sealant around the bottom end of the starter pipe and attach the assembly to the stove using three 1/4-20 x 3/8” Phillips screws provided in

the parts bag. (Fig. 20)

CEMENT

ST648a

Fig. 20 Attach inner assembly to flue collar.

4.Install the Outer Adapter Pipe. Insert the pipe over the stove flue collar, keeping the vertical seam oriented to the back of the stove. Also, be sure to align holes on the pipe with the holes on the flue collar of the firebox. Fasten the pipe to the holes in the flue collar with the #12 x 1/2” sheet metal screws provided. (Fig. 21)

ST650

Fig. 21 Fasten outer pipe with #12 x 1/2” sheet metal screw.

Install the Vent Adapter Pipe

(Simpson Dura-Vent Components)

1.Discard the inner starter pipe shipped in the Parts Bag. Using the starter pipe assembly listed on Page 12, slide the inner section out to allow access.

• Run a bead of sealant around the bottom end of the starter pipe and attach the assembly to the stove using three 1/4-20 x 3/8” Phillips screws provided in the parts bag. (Fig. 22)

2.Install the Outer Adapter Pipe. Orient the vertical seam to the rear, and insert the crimped end of the outer pipe into the flue collar. Fasten with three sheet metal screws provided. (Fig. 23)

1616

20012697

VO584-100

1/4-20 x

Inner Adpater Pipe

 

3/8” Phil-

 

lips Screws

 

 

CEMENT

ST649

Fig. 22 Simpson DuraVent - install inner adpater pipe.

ST651

Fig. 23 Simpson Dura-Vent - install outer adapter pipe.

Install Vent Adapter Pipe

(Selkirk Corporation Vent Components)

The appliance adapter (AA) adapts DIRECT-TEMP to most direct vent appliances incorporating outlet collars configured to receive most common 4” (ID) by 6⁄” (OD) or 5” (ID) by 8” (OD) “Twist Lock” style, direct vent systems.

The adapter incorporates two indentations on the outer wall of the inlet end, which are designed to “Twist Lock” into place upon attachment to the appliance outlet. Align the adapter indentations with the entry slots of the appliance outlet and slide together. Turn the adapter clockwise approximately one-quarter turn to lock in place. The outlet end of the adapter is standard DIRECTTEMP construction.

For connection of Direct-Temp to units with 4” x 7” flue outlets, the following methods have been approved:

Install the Universal/Napoleon Appliance Adapter 4DT-AAN.

Connect a standard Direct-Temp pipe length (do not use an adjustable length in this application) a

Radiance Direct Vent Gas Heater

minimum of 1¹⁄” over the flue outlet. The outside of the Direct-Temp Length will fit inside the flue outlet Secure with a minimum of two #8 x 1/4” sheet metal screws and seal with hi-temp silicone.

For units factory equipped with appliance adapters from other brands of Direct Vent systems, it is permissible to simply slide a length of DT pipe over the appliance adapter. Secure with a minimum of two #8 x 1/4” sheet metal screws and seal with hi-temp silicone.

Side Wall Termination Assembly

1.Locate the vent opening on the wall. Refer to Page 6, Figure 5, to determine the opening centerline. It may be necessary to first position the stove and measure to find the hole location. Depending on whether the wall is made of combustible materials,

cut the opening to the size shown in Figure 24. Combustible wall openings must be framed as shown in

Figure 24.

CFM System

9³⁄ ”

 

 

(240mm)

 

9³⁄ ”

 

 

(240mm)

 

 

Combustible Wall

 

DuraVent

10”

Framing Detail

System

(254mm)

 

 

10”

 

7¹⁄”

(254mm)

 

 

Noncombustible

NOTE: When Dura-Vent firestop is installed, Wall leave air space on top side of cut out.

Fig. 24 Locate vent opening.

2.Measure the wall thickness and cut the wall sleeve sections to proper length (MAXIMUM 12”). Assemble the sleeve with the #8 sheet metal screws supplied. Attach the firestop plate to the sleeve end with the holes. (Fig. 25) NOTE: The wall sleeve is required in combustible walls only.

3.Install the Wall Firestop/Sleeve assembly into the wall cutout and fasten the firestop to the wall cutout framing members. (Fig. 25)

For DuraVent pipe only: Install vent pipe by aligning the locking system together, sliding the pipes together and twisting clockwise.

Install 90° elbow. Twist lock as before.

Slide the wall plate over horizontal run before attaching the horizontal run to the elbow. Fasten wall plate to wall.

20012697

17

Radiance Direct Vent Gas Heater

12”

 

(305mm)

Sleeve

Max. Length

 

 

#8 Sheet

 

Metal Screws

Firestop

ZCS103

 

Fig. 25 Assemble the wall sleeve and firestop.

 

4.For CFM Vent Pipe only: If necessary, measure to determine the vertical length (X) of pipe required from the adapter pipe to the wall cutout centerline, including a 2” overlap at the joint. (Fig. 26) use a hacksaw or tin snips to trim the pipe as needed.

X

RADIANCE

ST652

Fig. 26 Determine the vertical pipe length.

5.Install first the inner then the outer straight pipe section(s), trimmed end down, to the point of the elbow. Drill 3 holes through each joint and fasten with sheet metal screws.

6.Install the elbow using 3 sheet metal screws at each joint.

7.Measure, and cut if needed, the appropriate length of pipe section needed to make the connection through the wall. Include a 2” overlap; i.e. from the elbow to the outside wall face, about 2” or the distance required if installing a second 90° elbow. (Fig. 27)

8.Slip the wall plate and trim collar over the interior end of the horizontal pipe and install into the wall

1818

X

ST215

Fig. 27 Measure the horizontal length.

sleeve. Seal the joint inside the wall plate if needed to keep cold air from being drawn into the home.

9.Connect the horizontal pipe to the elbow. Fasten the wall plate to the pipe with three sheet metal screws. Slide the trim collar up against the wall plate to cover the screws. (Fig. 28)

10.For both CFM and DuraVent Systems: Install the vent terminal. (Fig. 29) Apply high temperature sealant one inch from the ends of the inner and outer collars. Guide the inner and outer vent termination collars into the adjacent pipes. Double check that the vent pipes overlap the collars by 2”. Fasten the termination to the wall with the screws provided, and caulk the joint with weatherproof sealant.

Wall

Sleeve

ST216

Trim Collar

Wall Plate

Fig. 28 Install the horizontal pipe and wall plate parts.

Seal Both Terminal Ends

Caulk Plate Joint with

ST217

Weatherproof Sealant

Fig. 29 Install the vent terminal.

20012697

11. For CFM only: Install Charcoal Gray Pipe Rings (#7FSDRG) or Polished Brass Pipe Rings (#7FSDRP) at pipe joints, if desired.

Vent Termination Below Grade

Install Snorkel Kit #7FSDVSKS when it is not possible to meet the required vent termination clearances of 12” (305 mm) above grade level. The snorkel kit will allow installation depth of down to 7” (178 mm) below grade level. The seven inches is measured from the center of the horizontal vent pipe as it penetrates the wall. If the venting system is installed below grade, a window well must be installed with adequate and proper drainage. (Fig. 31)

NOTE: Be sure to maintain side wall clearances and vent run restrictions. Refer to Page 6, Figures 3, 4, 5, 6.

1.Establish the vent hole through the wall.

2.Remove soil to a depth of approximately 16” (406 mm) below the base of the snorkel. Install a window well (not supplied). Refill the hole with 12” (305 mm) of coarse gravel and maintain a clearance of at least 4” (102 mm) below the snorkel. (Fig. 31)

3.Install the vent system as described on Pages 16-18.

4.Be sure to make a watertight joint around the vent pipe joint at the inside and outside wall joints.

5.Apply high temperature sealant around the inner and outer snorkel collars. Join the pipes and fasten the snorkel termination to the wall with the screws provided.

6.Level the soil to maintain a 4” clearance below the snorkel.

If the foundation is recessed, use extension brackets (not supplied) to fasten the lower portion of the snorkel. Fasten the brackets to the wall first, and then fasten to the snorkel with self-tapping #8 x 1/2” sheet metal screws. Extend the vent pipes out as far as the protruding wall face. (Fig. 31)

Recessed Wall

 

 

Firestop

Sheet Metal

Finishing

Screws and

Collar

Bracket

 

Wall Screws

 

and Anchors

 

Waterproof Seal

 

Around Pipe

 

 

7” Pipe

 

Wall Plate

ST219

 

Fig. 30 Use extension brackets to mount snorkel against recessed wall.

Radiance Direct Vent Gas Heater

 

Wall Screws

 

 

and Anchors

Waterproof Seal

 

 

Snorkel

Around Pipe

Termination

Firestop

Cap

 

 

 

4” Clearance

 

 

Gravel

 

 

Drain

 

 

Window Well

 

 

 

RADIANCE

 

 

ST653

Fig. 31

Snorkel kit installation.

 

Vertical (Through the Roof)

Vent Assembly

Make certain the vent system conforms to all other requirements for vertical termination as specified on Page 9.

This installation will require you to first determine the roof pitch and use the appropriate vent components. Refer to Figure 11 on Page 10.

1.Locate the final position of the stove, observing all clearances for both the vent and the stove.

2.Plumb to the center of the inner (4”) flue collar from the ceiling above, and mark that location.

3.Cut the opening:

CFM System: 9³⁄ ” x 9³⁄ ” (240 x 240 mm)

DuraVent System: 10” x 10” (254 x 254 mm)

4.Plumb any additional opening through the roof or other construction that may be needed. In all cases, the opening must provide a minimum of 1” (25 mm) clearance to the vent pipe.

5.Place the stove in its final position.

6.Install firestop(s) #7DVFS and Attic Insulation Shield #7DVAIS as needed. (Fig. 32) If there is a room above ceiling level, a firestop must be installed on both the bottom and top sides of the ceiling joists. If an attic is above ceiling level, an attic insulation shield must be installed.

20012697

19

Radiance Direct Vent Gas Heater

#7DVAIS Attic Insulation Shield

 

Use Four

#7DVFS

 

Firestop in

 

8d Nails

 

Upper Floor

 

 

 

 

#7DVFS

ST222

 

Firestop in

 

Ceiling

 

 

Fig. 32 Install firestops and attic insulation shield.

7.Install the appropriate roof support and flashing, making certain that the upper flange of the flashing base is below the shingles. (Fig. 33)

8.Install appropriate pipe sections until the vent run reaches above the flashing. The enlarged ends of the vent sections always face downward.

9.Install the storm collar and seal around the joints. (Fig. 33)

10.Add additional vent lengths to achieve the proper overall height.

11.Apply cement to the inner and outer termination collars and install the terminal cap.

 

Use three #5

 

 

sheet metal

 

 

screws at

 

 

each joint

 

 

 

Sealant

Storm Collar

 

 

 

Upper

 

 

edge of

#7DVSKV

flange goes

(A, B, or

 

under upper

F) Roof

 

shingles

Support

 

 

Flashing

ST221

 

 

Fig. 33

Roof support and flashing.

 

Selkirk Direct-Temp Metalbestos Direct

Vent System

Installation Instructions

1.Determine whether the length of pipe fits the appliance outlet by attempting to engage the parts. If the parts engage smoothly, proceed to Step 2. If obstructions, interference or loose fit is noted, contact the appliance manufacturer or Selkirk Metalbestos with the dimensions of the appliance outlet.

2.Slide the length of pipe over the appliance outlet a minimum of 1¹⁄” and screw to the appliance outlet collar using a minimum of two (2) #8 x 1/4” sheet metal screws.

Appliance Adapter (AAV)

The appliance adapter (AAV) adapts DIRECT-TEMP to most direct vent appliances incorporating outlet collars configured to receive most common 4” (ID) 6⁄” (OD) or 5” (ID) by 8” (OD) “Twist Lock” Style, direct vent systems.

The adapter incorporates two (2) indentations on the outer wall of the inlet end, which are designed to “Twist Lock” into place upon attachment to the appliance outlet. Align the adapter indentations with the entry slots of the appliance outlet and slide together. Turn the adapter clockwise approximately one-quarter turn to lock in place. The outlet end of the adapter is standard DIRECT-TEMP construction.

Framing Dimension Table 1

Model DT

Ceiling Support (CS)

Cathedral Ceiling

Wall Thimble

Diameter

Firestop (FS)

Support CCS)

(WT)

4”

8¹⁄ ” x 8¹⁄ ”

10 ⁄ ” x 10 ⁄ ”

8¹⁄ ” x 8¹⁄ ”

5”

10¹⁄ ” x 10¹⁄ ”

14¹⁄ ” x 14¹⁄ ”

10¹⁄ ” x 10¹⁄ ”

Use of Sealant

It is not required to apply or use sealant on the inner liner of DIRECT-TEMP. For outer wall joint sealing considerations, follow appliance manufacturer recommendations.

Joint Connection:

The pipe and elbows are assembled by inserting the outlet (male) end of a length of pipe or elbow into the inlet (female) end of an adjacent length of pipe or elbow. Make sure the outlet end is fully seated within the inlet end of the adjoining section and the gasket, located on the inner liner of the inlet section is fully enclosed by the inner liner of the outlet of the adjoining section. Push in the Lock Tab such that it becomes seated within the inward groove of the adjoining section. This locks the joint in place. (Fig. 34)

Supporting DIRECT-TEMP: Vertical Support

Vertical installations can be supported by two methods:

Ceiling Support (CS) (used in flat ceiling installation) comes with a support plate and a support collar. Install

2020

20012697

Radiance Direct Vent Gas Heater

 

Gasket

 

Inlet End

 

Outlet End

To Termination

Lock Tab

To Appliance

 

 

ST922

Fig. 34 Joint connection.

 

 

Vent Termination (VC)

 

 

Storm Collar (SC)

Roof Flashing (AF)

Ceiling Support (CS)

Trim Plate (TP)

Pipe Length

Pipe Length

it by screwing the support plate to the top of the properly framed ceiling joist opening, using screws provided. A round trim plate (TP) is attached to the ceiling, using screws, to provide a finished appearance once installed. (Fig. 35)

Ceiling Support

Ceiling Support Collar

Plate

Trim Plate

ST923

Fig. 35 Ceiling support.

Horizontal Termination (HC)

Trim Plate (TP) (Required if Wall Thimble is not used)

Pipe Length

90° Elbow (EL90)

Wall Thimble (WT)

(Optional)

Vertical Venting

Pipe Length

Appliance Adapter

(AAV)

Appliance Adapter

(AAV)

Horizontal Venting

ST924

ST925

Fig. 36 Selkirk Venting Components

20012697

21

Radiance Direct Vent Gas Heater

The Cathedral Ceiling Support (CCS) may be used in pitched or flat ceiling installations and comes with a support collar and a decorative two part square trim plate. Install by inserting the support box down through the framed joist opening (end with round hole first) in the ceiling using tin snips, cut the corners of the open end of the box such that the sides can be folded down over the top of the joist framing members. Nail the folded sides to the top of the framing. (Fig. 37)

Two Part Square

Trim Plate

Support Box

Support Box Collar

ST926

Fig. 37 Support box.

A two-part square trim plate is provided to give a finished look once installed. Simply fit the two halves of the trim plate around the cathedral ceiling support box hanging below the ceiling (overlapping if necessary) and screw them to the ceiling. Both the ceiling support and cathedral ceiling support can support a maximum of 40’ (12 m) of pipe.

Offsets:

If any offsets are necessary in the vertical system, an Offset Support (OS) should be installed directly above the upper elbow of the offset. Install by attaching the offset support band to the pipe with two #8 x 1/4” sheet metal screws (minimum ) and secure the offset support straps to surrounding structure. (Fig. 38)

 

Nail to top of

 

framing

Offset Support

Offset Support

Strap

Collar

ST927

Fig. 38 Offset support.

Supporting DIRECT-TEMP: Horizontal Support

Horizontal runs of Direct-Temp should be supported every 4’ (122 cm) of pipe. This can be done with the use of plumbers strapping or the offset support.

Adjustable Length (AJ)

An Adjustable Length is available to accommodate installations where non-standard lengths are necessary.

The adjustable length telescopes down over a standard length of pipe and provides an extension range of 3¹⁄ ” (89 mm) to 10¹⁄ ” (267 mm). Install by sliding the inlet end of the adjustable length over the outlet end of a standard length of pipe. After positioning the adjustable length appropriately, secure it to the standard length with two (2) #8 x1/4” sheet metal screws (provided). Seal the area between both the top and bottom of the adjustable length outer wall and the outer wall of the standard length with an approved silicone sealant.

Fire Stopping

DIRECT-TEMP must be firestopped wherever it passes through floors, ceiling or walls. The only location where a firestop is not required is at the roof level. Both vertical support components with trim plates provide for firestopping. The wall thimble also acts as a firestop. AT other locations, a firestop spacer (FS) should be installed. In the attic the firestop should be placed on top of the joist framing to prevent debris from falling into the joist framing. (Fig. 39)

Firestop (FS) Placed on Top of Framed Opening

 

Maintain at Least

 

Minimum Clearance to

Attic Framing

Combustibles, Wire and

(No floor)

Insulation

 

ST928

Fig. 39 Firestop spacer.

Horizontal Installation

1. Determine the appliance location. Refer to the appliance manufacturer’s installation instructions for clearance to combustible requirements, termination options, number of elbows, maximum length, etc. Then position the appliance and plan vent routing accordingly. Consider locating the appliance in a place where there will be no interference with wall studs, electrical wiring, conduit, plumbing pipe or other obstructions. The termination should be located at least 12” (305 mm) (Fig. 40) above grade, remain above the snow line in geographical areas that accumulate snow and be away

2222

20012697

from traffic areas such as walkways if it is less than 7’ (2.1 m) high. Refer to Pages 10, 11, Figures 11, 12 for more detail.

Snorkel Termination

Window Well

 

12” (305 mm) Minimum

Maintain 2”

Clearance Above Grade Level to

(51 mm)

Air Intake

Clearance

Grade Level

Below Snorkel

Sloped Away

 

 

From Building

Adequate

 

Drainage as per

 

Local Codes

 

 

ST929

Fig. 40 Below grade installation.

2.Assemble the pipe (and elbow if using) and attach it to the appliance. Plan for a level to 1/4” per foot rise (6 mm per 305 mm) (from inlet to outlet) in the horizontal system if not specified by the appliance manufacturer. Horizontal runs should be supported every 4’ (122 cm).

3.Push the appliance near the desired location. Determine the centerpoint of the penetration by locating the centerline of the outlet of the pipe with respect to the wall.

4.Frame an opening to the dimension specified in the Framing Dimension Table 1. Ensure the centerline of the pipe lines up with the center of the prepared opening unless otherwise specified by the appliance manufacturer.

NOTE: As a general rule, the wall thimble is optional in the U.S. However, there may be some manufacturers that require it. Contact the appliance manufacturer for information if uncertain. When installed in Canada, a wall thimble is required on all installations in which the vent passes through a combustible wall.

5. If required, install the outside half of the wall thimble (WT) through the opening and screw or nail in place. (Fig. 41) Seal around the perimeter of the thimble face plate on the exterior wall using an RTV silicone sealant to provide protection from possible rain infiltration. (Fig. 41)

NOTE: The wall thimble accommodates wall thicknesses of 4¹⁄ ” (114 mm) to 7¹⁄ ” (191 mm). If a larger range is needed due to a thicker wall, it is permissible to field fabricate a metal sleeve extension and attach it to the shields.

6. Install the horizontal termination to the exterior wall using four (4) all purpose screws through the holes located at each corner of the termination. Make sure the arrow (embossed on the front of the termination) is pointing up. (Fig. 42) If the house has vinyl siding,

 

Radiance Direct Vent Gas Heater

 

 

 

 

 

 

Wall Thimble

 

 

Shield

 

 

 

Seal with RTV

 

 

Wall

 

 

Silicone Sealant

 

 

Thimble

 

 

on Exterior side

 

 

 

 

 

 

 

Shield

 

 

here (around

 

 

 

 

 

 

 

perimeter)

 

 

 

 

 

 

 

 

 

 

 

 

Wall

Wall Thimble

Thimble

Face Plate

Face

 

Plate

 

 

ST930

Fig. 41

Wall thimble.

 

Horizontal Termination

ST931

Fig. 42 Horizontal termination.

a Vinyl Siding Standoff (VS) must be installed prior to installing the horizontal termination. Refer to the appliance manufacturer to determine if one is recommended. Attach the vinyl siding standoff to the exterior side of the wall (making sure it is level and centered with respect to the opening) with screws (provided) at each corner of the standoff. Attach the horizontal termination to the standoff. (Fig. 43)

Vinyl Siding Standoff

Horizontal Termination

ST932

Fig. 43 Vinyl siding standoff and horizontal termination.

20012697

23

Radiance Direct Vent Gas Heater

If the wall is brick or concrete, and contains no combustible material, a 7” (178 mm) round penetration hole is adequate. The wall thimble is not required. The perforated straps of the horizontal termination provide a method of attachment. These can either be threaded through the opening or wall thimble (if used) and screwed to the pipe or removed with a pair of tin snips if not used. Use proper masonry fasteners to attach the horizontal termination to the wall.

7. If a wall thimble is used, push the pipe (which is connected to the appliance) carefully through the wall thimble until the DIRECT-TEMP pipe becomes fully engaged with the horizontal termination. If no thimble is used, place the Trim Plate (TP) on the DIRECT-TEMP pipe. Carefully push the DIRECT-TEMP pipe through the wall until fully engaged with the horizontal termination. Secure the trim plate to the wall.

NOTE: If a vertical rise is necessary on the exterior side of the building, a 14” (356 mm) and 36” (914 mm) Snorkel Termination (ST) is available. Follow the installation procedures for horizontal terminations. If the snorkel termination is to be located below grade, a window well is recommended with adequate and proper drainage as per local codes. Leave 2” (51 mm) clearance below snorkel to prevent water from entering the snorkel termination. Do not enclose the snorkel within a wall or other type of enclosure and do not back fill. Ensure that grade level slopes away from the building. (Fig. 40)

Vertical Installation (Fig. 44)

1.Determine the location of the appliance. Choose a location which provides adequate clearance from obstacles such as electrical wiring, conduit, framing members, plumbing pipe, etc.

2.After positioning the appliance, determine where the vent pipe will pass through the ceiling. This can be done by using a plum bob or a small weight attached to a string. Hold the plum bob from the ceiling moving it until it lines up with the centerline of the outlet of the appliance. Mark the position on the ceiling.

NOTE: Frame openings to the dimensions specified in the framing table for the cathedral ceiling support box (CCS), the ceiling support (SC) and wherever the firestop spacer (FS) is being used.

3.Cut and frame the appropriate sized square hole through the ceiling. Repeat the process for other ceiling penetrations as necessary.

4.Determine and mark the roof penetration in the same manner.

5.Cut a hole in the roof at this point large enough to satisfy all clearance-to-combustible requirements as specified by the appliance manufacturer’s installation instructions.

6.Install the ceiling support cathedral ceiling support box assembly, as appropriate.

Vertical Termination

Storm Collar

Approved Silicone

Sealant Here

Flashing

Offset Support

Collar

Firestop

Spacer

Ceiling

 

 

Support

Ceiling Support Collar

 

Plate

 

 

 

 

Trim Plate

ST933

 

 

Fig. 44 Typical vertical venting configuration.

7.Determine the distance from the appliance outlet to a point just above [approximately 12” (305 mm) to 24” (610 mm)] either the cathedral ceiling support box or the ceiling support plate and assemble lengths of pipe to satisfy this distance. Do not attach assembly to appliance.

8.Loosely position the support collar around the assembled lengths (flared end down).

9.From above, lower the assembled pipe sections down through the cathedral ceiling box or ceiling support plate and attach it to the appliance adapter. The support collar should then be adjusted so that when the assembled lengths of pipe are attached to the appliance, it rests on the bottom of the cathedral ceiling support box on top of the ceiling support plate.

10.Tighten the tabs of the collar. Secure the sup-

port collar by inserting three (3) #8 x 1/4” sheet metal screws through the support collar and the outer wall of the pipe.

NOTE: If the cathedral ceiling support box assembly is being used, it may be necessary to temporarily connect

2424

20012697

the assembled pipe to the appliance. Determine and mark the location of where the support collar will be attached to the pipe. Disconnect and remove assembled pipe. Attach the support collar per Step 10 (where marked) and reinstall assembly. This is due to limited space within the cathedral ceiling support box. Install any required offset supports.

11. Add lengths of pipe and firestop as necessary until assembly extends to a point above the roof which complies with local code requirements for minimum termination height and with the appliance manufacturer’s installation instructions. (Fig. 45)

 

Minimum

Roof Pitch

Height

Flat to 7/12

1’0”

Over 7/12 to 8/12

1’6”

Over 8/12 to 8/12

2’0”

Over 9/12 to 10/12

2’6”

Over 10/12 to 11/12

3’3”

Over 11/12 to 12/12

4’0”

Over 12/12 to 14/12

5’0”

Over 14/12 to 16/12

6’0”

Over 16/12 to 18/12

7’0”

Over 18/12 to 20/12

7’6”

Over 20/12 to 21/12

8’0”

Minimum Height

Above Roof

Fig. 45 Minimum Height Above Roof Requirements

Radiance Direct Vent Gas Heater

NOTE: Whenever DIRECT-TEMP penetrates through a ceiling, a floor or a wall, it must be firestopped.

12.Using a level, make sure the system is perfectly vertical.

13.Slide the flashing, suitable for the roof pitch, down over the pipe protruding through the roof. Recheck orientation and use a silicone sealant around and under the perimeter of the flashing where it is in contact with the roof. Secure the flashing with roofing nails. Finish roofing around the pipe, covering the sides and upper ares of the flashing base with roofing material. However, be sure the lower unnailed portion of the base covers the roofing material.

14.Position the storm collar around the pipe and slide down until it is in contact with the flashing. Secure the storm collar by inserting the two (2) tabs into the raised slots and fold tabs back. Seal the area between the storm collar and the vent pipe with a silicone sealant to prevent rain infiltration.

15.Install the vertical termination (VC) by inserting it down into the top most section of pipe until it is fully seated. Depress lock tab to secure the cap to the pipe. NOTE: In high wind areas, it is recommended to screw termination to the pipe with two (2) #8 x 1/4” sheet metal screws. The screws should be approximately 3/4” from the bottom of the vertical termination’s galvanized collar.

Install Log Set

Before beginning log installation, remove stove front and glass frame. Refer to Figures 44 and 47.

1. Remove the logs from their packaging and inspect each piece for damage. DO NOT INSTALL DAM-

AGED LOGS.

ST141

Fig. 47 Release the latches to remove the glass frame.

ST139

Fig. 46 Remove the stove front.

20012697

25

Radiance Direct Vent Gas Heater

2.Install the rear log by placing it on the ember bed toward the back of the firebox. (Fig. 48) The log should touch the back wall of the firebox. When the log is in place, the two (2) notches on the bottom of the log rest on the two (2) ribs on the back side of the ember bed. (Fig. 49)

Rear Log

Figure 48

Ribs for Rear Log

Figure 49

Rib Flat Spot for

Front Left Log

3.Install the front left and right logs (Fig. 50) by placing them on the ribs shown in Figure 49. Make sure the logs line up with the flat spots on the ember bed intended for location purposes. (Fig. 49)

4.Install the left cross log by engaging the hole on the bottom with the pin on the left side of the rear log. Set front side of cross log on notch in ember bed. (Fig. 51)

5.Install the right cross log by engaging the hole on the bottom with the pin on the right side of the rear log. Set front edge of cross log on ember bed as shown in Figure 51.

Figure 50

Front Left Log

LG488

Ember Bed

LG487

Rib and Flat Spot for Front Right Log

LG489

Front Right Log

2626

20012697

Left Cross

Log

Figure 51

Front Left Log

Connect the Gas Supply Line

Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Radiance may be converted from one gas to another using the appropriate Fuel Conversion Kit listed on Page 45.

In the U.S.; Gas connection should be made in accordance with current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Since some municipalities have additional local codes, be sure to consult your local authority.

In Canada; consult the local authority and CSA-B149.1 installation code.

Always check for gas leaks with a mild soap and water solution. Do not use an

open flame for leak testing.

Light the pilot according to the directions on Page 30, before going to the next step.

Burner Information

The appliance must only use the gas specified on the rating plate, unless converted using a Vermont Castings Fuel Conversion Kit. To convert from Natural Gas to LP use Kit 20012729 or 20012900. To convert from LP to Natural Gas use Kit 20012899 or 20012902.

Conversion instructions are provided with each kit and beginning on Page 36 in this manual.

Radiance Direct Vent Gas Heater

Rear Log

Right Cross Log

Front Right Log

LG490

Ember Bed

CAUTION

This appliance should only be connected by a qualified gas technician. Test to confirm manifold pressures as specified below.

The Radiance Heater and its individual shutoff valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The Radiance Heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig.

There must be a gas shutoff between the stove and the supply.

In order to connect Natural Gas, use a fitting with 1/2” NPT on the valve side and 1/2” natural gas supply line with an input of 38,000 BTUs at a manifold pressure of 3.5” between minimum inlet supply of 5.5” w.c. and maximum of 14.0” w.c.

In order to connect Propane, use a fitting with 1/2” NPT on the valve side and 1/2” propane gas supply line with an input of 36,000 BTUs at a manifold pressure of 10.0” between a minimum inlet supply of 11.0” w.c. and maximum of 14.0” w.c.

20012697

27

Radiance Direct Vent Gas Heater

THIS APPLIANCE SHOULD BE CONNECTED TO THE GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE TECHNICIAN. FOLLOW ALL LOCAL CODES.

THERE MUST BE A GAS SHUT-OFF BETWEEN THE STOVE AND THE SUPPLY.

Install ON/OFF Switch

The switch assembly parts are found in the parts bag.

1.Attach switch assembly to left rear side of stove shroud (when facing shroud) using two screws and existing holes in shroud. (Fig. 52)

2.Run wires down back of stove, under bottom of rear shroud to valve.

3.Attach wires to valve terminals. (Fig. 53)

Switch As-

sembly Existing Holes

Screws

ST315

 

Fig. 52 Attach switch assembly to rear shroud.

TH TP TPTH

PILOT

ADJ

ST228

Fig. 53 Attach switch wires to valve.

Thermostat Connection (optional)

Use only a thermostat rated for 500 - 750 millivolts.

Check the table below for the appropriate gauge thermostat wire to use for the length of lead required in your installation.

Thermostat

 

Wire / Gauge

Maximum Run

18

20 feet

16

20 - 40 feet

14up to 60 feet

1.Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors.

2.Connect the thermostat wires to the valve. (Fig. 53)

Install the Mesh and Grille

Place the mesh and grille on the top of the Radiance stove to complete assembly.

Operation

The Radiance is operated with the front plate in place with the doors open or closed. To open the front doors, pull forward to separate the magnetic catch.

Your First Fire

Read these instructions carefully and familiarize yourself with the burner controls shown on Page 29. Locate the pilot assembly, Figure 54. Follow the lighting instructions on Page 30 exactly.

During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within the first eight to ten hours, however, you can open a window to provide fresh air to alleviate the condition.

Pilot and Burner Inspection

CAUTION: DO NOT TOUCH DOORS WHEN HOT!

Each time you light your heater check that the pilot

flame and burner flame patterns are as shown in Figure 56. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for assistance. Do not operate the heater until the pilot flame is correct.

2828

20012697

Pilot As-

sembly

ST476

Fig. 54 Pilot Assembly location.

Follow regular maintenance procedures as described on Page 41.

Flame & Temperature Adjustment

For stoves equipped with HI/LO valves, flame adjustment is accomplished by rotating the HI/LO adjustment knob located near the center of the gas control valve. (Fig. 55)

Radiance Direct Vent Gas Heater

Turn

 

Turn clockwise

counterclockwise

H

 

I

 

to increase

LO

to decrease

flame height

 

flame height

Fig. 55 Flame adjustment knob for SIT valve.

Flame Characteristics

It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to Figure 56. If any of the flames appear abnormal, call a service person.

 

SIT Pilot

RADVT Series

PSE

 

 

 

Pilot

 

 

RADVTC Series

 

CO105d

(Comfort Control Models)

 

 

 

LG491

Fig. 56 Correct pilot and burner flame appearance.

20012697

29

Radiance Direct Vent Gas Heater

Lighting and Operating Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly.

B.BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.Turn the On/Off switch to “OFF” position, set the remote to OFF or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn clockwise to “OFF”.

 

 

 

ILO

T

 

 

 

 

 

P

 

t

 

1

 

 

 

 

 

F

 

 

 

lo

 

 

 

 

 

F

 

 

 

P

 

 

 

 

 

i

 

2

O

 

 

 

O

 

 

 

 

 

 

 

F

 

 

 

F

 

 

 

 

 

 

5

 

3

FFO

 

 

 

4

 

 

 

 

 

 

 

 

 

 

Euro SIT

SIT NOVA

Honeywell

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you do not smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal section).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to “PILOT”.

10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2"

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to “OFF” and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to “ON” position.

13.Turn the On/Off switch to “ON” position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

To Turn Off Gas To Heater

1.Turn the On/Off switch to Off position or set the thermostat to lowest setting.

2.Turn off all electric power to the fireplace if service is to be performed.

3.Open control access panel.

4.Push in gas control knob slightly and turn clockwise to “OFF”. Do not force.

5.Close control access panel.

3030

20012697

Radiance Direct Vent Gas Heater

Troubleshooting the Gas Control System (RADVT Series)

SIT NOVA 820 MILLIVOLT VALVE

NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position.

 

Symptom

Possible Causes

Corrective Action

 

 

 

 

1.

Spark ignitor will not light

A. Defective or misaligned electrode

Using a match, light pilot. If pilot lights, turn off pilot and

 

 

at pilot

push the red button again. If pilot will not light - check

 

 

 

gap at electrode and pilot-should be 1/8” to have a

 

 

 

strong spark.

 

 

 

 

 

 

B. Defective ignitor (Push Button)

With the control knob in the pilot position, push the

 

 

control knob all the way and hold. Check for spark at

 

 

 

 

 

 

electrode and pilot. If no spark to pilot, and electrode

 

 

 

wire is properly connected, replace the battery in the

 

 

 

ignitor module and try again. Refer to Maintenance

 

 

 

Section. If the problem still exists, replace the ignitor

 

 

 

module box.

 

 

 

 

2.

Pilot will not stay lit after

A. Defective pilot generator (thermo-

Check pilot flame. Must impinge on thermocouple/ther-

mopile. NOTE: This pilot burner assembly utilizes both

 

carefully following lighting

couple), remote wall switch

 

a thermocouple and a thermopile. The thermocouple

 

instructions

 

 

 

operates the main valve operation (On and Off). Clean

 

 

 

 

 

 

and or adjust pilot for maximum flame impingement on

 

 

 

thermopile and thermocouple.

 

 

 

 

 

 

B. Defective automatic valve

Turn valve knob to “Pilot”. Maintain flow to pilot; millivolt

 

 

 

meter should read greater than 10mV. If the reading

 

 

 

is okay and the pilot does not stay on, replace the gas

 

 

 

valve. NOTE: An interrupter block (not supplied) must

 

 

 

be used to conduct this test.

 

 

 

 

3.

Pilot burning, no gas to

A. Wall switch or wires defective

Check wall switch and wires for proper connections.

Jumper wire across terminals at wall switch, if burner

 

main burner

 

 

 

comes on, replace defective wall switch.. If okay,

 

 

 

 

 

 

jumper wires across wall switch wires at valve, if burner

 

 

 

comes on, wires are faulty or connections are bad.

 

 

 

 

 

 

B. Thermopile may not be generat-

1. Be sure wire connections form thermopile at gas

 

 

valve terminals are tight and thermopile is fully

 

 

ing sufficient millivoltage

 

 

inserted into pilot bracket.

 

 

 

 

 

 

2. One of the wall switch wires may be grounded. Re-

 

 

 

move wall switch wires form valve terminals if pilot

 

 

 

now stays lit, trace wall switch wiring for ground.

 

 

 

May be grounded to fireplace or gas supply.

 

 

 

3. Check thermopile with millivolt meter. Take reading

 

 

 

at thermopile terminals of gas valve. Should read

 

 

 

250-300 millivolts (minimum 150) while holding

 

 

 

valve knob depressed in pilot position and wall

 

 

 

switch “Off”. Replace faulty thermopile if reading is

 

 

 

below specified minimum.

 

 

 

 

 

 

C. Plugged burner orifice

Check burner orifices for debris and remove.

 

 

 

 

 

 

D. Defective automatic valve opera-

Turn valve knob to “On”, place wall switch to “On”

 

 

millivolt meter should read greater than 150mV. If the

 

 

tor

 

 

reading is okay and the burner does not come on,

 

 

 

 

 

 

replace the gas valve.

 

 

 

 

4.

Frequent pilot outage

A. Pilot flame may be too low or

Clean and/or adjust pilot flame for maximum flame

impingement on thermopile and thermocouple.

 

problem

blowing (high) causing the pilot

 

 

 

 

safety to drop out

 

 

 

 

 

 

 

B. Possible blockage of the vent

Check the vent terminal for blockage (recycling the flue

 

 

terminal

gases).

 

 

 

 

20012697

31

Radiance Direct Vent Gas Heater

Instructions for Comfort Control Valve

RADVTC Series

The Comfort Control valve allows remote control of temperature, fan and flame appearance.

NOTE: The antenna should hang in free air away from grounded metal.

Operation

1.If the manual switch is in remote position, switch it to LOCAL. (Fig. 57)

2.Turn the pilotstat knob counterclockwise from OFF to the PILOT position, push the knob down, and hold in position. The pilot valve opens and allows gas to flow to the pilot burner.

3.Push plunger on the piezo until the pilot burner is lit. When the pilot burner is lit, the LED on the control will come on after approximately 40 seconds and will provide 1 short blink continuously in the normal mode. When the light turns off which will be approximately 10 seconds after it has been continuously red, the receiver/valve is fully powered.

Motor Top Cap

Piezo Ignitor

 

 

 

 

PILOT

OFF

 

 

 

 

REMOTE

ON•

 

LOCAL

 

LED

 

 

 

 

 

LED

Local/Remote

Pilotstat

Plug

Switch

Knob

 

 

Antenna

FP1037

Fig. 57 Comfort control valve.

4.Release the knob. The shaft will move upward. The pilot burner should now stay burning. If the pilot burner goes out, repeat step 2.

5.Turn the knob counterclockwise to the ON position. If the manual switch is in the LOCAL position, the main burner will turn on immediately.

6.ON the initial use of a transmitter, a recognition operation is required between the receiver/valve and transmitter. Change the switch from LOCAL to REMOTE. Press the fan or flame button on the transmitter within 30 seconds. The LED will blink indicating the transmitter will now work with the re-

ceiver/valve. If the switch continues in the REMOTE position, the transmitter will now control the main valve, flame modulation level and fan control.

7.If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting and the fan will be at the highest fixed speed. The transmitter will control the fan only.

Shut Off Procedure

If the manual switch is in the REMOTE position, the transmitter can shut off the main burner and fan. However, the control is still on and a command from the transmitter can turn on the main burner or fan.

To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The transmitter cannot turn on the main burner or fan.

Transmitter Operation

Off Mode

In the OFF mode, the fireplace flame and fan are off, the display will show OFF and displays the room temperature. If the receiver is in REMOTE mode, the fireplace will shut off.

 

Display

 

Room Temperature

 

Set Temperature

 

Flame Height Level

Mode

Fan Speed Level

Auto

Countdown Timer

On

Low Battery

Off

Flame

Countdown

Up

Increases Flame

Timer

Height, Fan Speed

 

Timer, or Set Point

Fan

Down

Decrease

 

Flame, Fan

 

Speed Timer

FP1039

or Set Point

Fig. 58 Transmitter diagram.

On (Manual) Mode

In the ON mode, the room temperature, flame and fan levels will be shown. MANUAL will appear next to both the flame and fan icons.

When the control is in the ON mode, the flame and fan levels, and delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit.

Delay Timer Mode

The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes.

3232

20012697

Auto Mode

In the AUTO mode, the room temperature, set temperature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons.

When the control is in the AUTO mode, the main burner will turn on/off or modulate based on the heat needed to maintain the set temperature. The flame level will change automatically to optimize the heat output needed to maintain the set temperature. To change the set temperature, press the up or down key. Pushing a key once will change the temperature by one degree.

In the AUTO mode, the fan speed will increase with increasing flame height or decrease with decreasing flame height. “AUTO” is displayed next to the flame and fan icons.

Fan Override During Auto Mode

If a lower or higher fan speed is desired when operating in the AUTO mode, the fan speed can be overridden by pushing the fan button followed by the up or down key. Pushing a key once will change the fan level by one unit. In this mode “AUTO” is displayed next to the flame icon and “MANUAL” is displayed next to the fan icon.

Change Between F/C Temperature Units

Push the up and down arrow keys simultaneously for at least 3 seconds to toggle between Fahrenheit and Celsius units.

Disable Thermostat Function

To disable the thermostat function in the AUTO mode, push the time and down keys simultaneously for at least 3 seconds.

To Change Batteries

1.Remove cover on the backside of the transmitter. Install 3 AAA batteries as shown and reattach cover.

2.Once steps 1-3 in OPERATION are completed, receiver/valve and transmitter are now ready. Press any button on transmitter for recognition process to occur between the receiver/valve and transmitter.

3.Use functions as described in TRANSMITTER section.

Troubleshooting

1.Locate LED light on valve.

2.LED will blink after every valid command received by the transmitter; this is not an error.

3.Failure codes may occur anytime after pilot burner is lit.

4.Sequence is failure code followed by light not blinking for 30 seconds.

Radiance Direct Vent Gas Heater

 

 

Pilot As-

 

 

 

sembly

 

 

 

 

Blower

 

 

Red

FAN

 

 

 

 

Red

White

 

 

 

 

 

White

 

 

 

 

White Dots

 

 

Antenna

 

FP1038

 

Comfort Control Valve

 

(Bottom View)

 

Fig. 59 Comfort Valve wiring diagram.

 

5.In the event of multiple failure codes, next failure code follows previous failure code by approximately 3 seconds.

If an Error Code 3 is observed while performing the testing, complete the following:

1.Make sure the spade connectors are pushed all the way on. If rhe Error Code 3 is still showing, then go to the next step.

2.Switch the front two thermopile leads with the back two. Be sure the white lead is connected to the spade with the white dot next to it. If the Error Code 3 is still showing, replace the thermopiles.

If an Error Code 8 is observed while performing the testing, complete the following:

1.Confirm the valve is not in REMOTE mode.

If the valve is producing Error Code 8 and in REMOTE mode, the valve is defective and should be replaced.

If the valve is in LOCAL mode and producing Error Code 8, then go to the next step.

2.Slide the Remote/Local switch to REMOTE and teach the valve a transmitter. The Error Code will clear itself after approximately 1.5 minutes and return to normal operation.

LED Count

Service Action

8Replace valve

7 Confirm stepper motor connection exists

5 Confirm fan connection exists and works

4 Confirm gas type; jumper in place

3 Replace thermopiles

2 Turn fan ON NOTE: Some keys are not active.

20012697

33

Radiance Direct Vent Gas Heater

Comfort Control Valve System Sequence of Operation with Transmitter

Set manual switch to local or remote

Five minute wait period

Light pilot burner

Did the LED stop

No

Review LED fail-

blinking?

 

 

ure analysis.

 

 

 

 

 

 

 

 

 

 

Release pilotstat knob.

Yes

Turn pilotstat knob from PILOT to ON.

Cycle switch once and leave in remote. Press any

key on transmit- ter for recognition

operation.

Choose Manual or Remote path. Set switch to manual or remote.

Local Path

On Path

 

 

 

 

If manual switch is

 

 

 

Move switch from

 

 

 

 

 

 

If the manual switch

 

 

 

 

 

 

set to LOCAL, did

 

 

 

local to remote.

 

 

 

 

 

 

 

is set to REMOTE,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

main burner light

 

 

 

Press any key on

 

 

 

 

 

 

press the mode but-

 

 

 

 

 

 

and fan turn on?

 

 

 

transmitter. Move

 

 

 

 

 

 

 

ton to display “ON”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

switch back to

 

 

 

 

 

does transmitter con-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

local.

 

 

 

 

 

 

 

trol the main burner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

and fan?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn pilotstat knob

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to PILOT to turn

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off main burner.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does transmitter

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

change levels of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

flame height, fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

speed?

 

 

 

 

 

 

Turn pilotstat knob

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to OFF to turn

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

valve completely

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off.

 

 

 

 

 

 

 

 

 

 

 

Set levels of flame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

height and fan to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“0” to shut off main

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

burner and fan.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn pilotstat knob

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to OFF to turn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

valve completely

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Move switch from manual to remote. Press any key on transmitter.

3434

20012697

Radiance Direct Vent Gas Heater

Auto Path

If the manual switch is set to REMOTE, press the mode button

to display AUTO on the transmitter. Does the transmitter display the

room and temperture setting?

Move switch from LOCAL to REMOTE. Press any key within 30 seconds.

Yes

If the settings is above

room temperture on the No

transmitter, does the main valve and fan

turn on?

Yes

If the settings is below

room temperture on the No

transmitter, does the main valve and fan

turn off?

Turn pilotstat knob to OFF to turn valve completely off.

20012697

35

Radiance Direct Vent Gas Heater

Fuel Conversion Instructions

WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion

or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.

CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion.

I

H O

TPILOJAD

Main

Gas Line

Gas Supply Inlet

ST226a

Fig. 60 Attach the gas line to the right side of the valve.

Conversion Precautions

Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance.

Conversion Procedure

1.Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Page 25, Fig. 46)

2.Undo the right and left latches at the top of the glass frame. (Page 25, Fig. 47)

3.Pull the top edge of the glass and frame assembly away from the firebox face. Place the assembly out of the way on a flat, padded surface such as a counter protected by a towel.

4.Remove the logset from the firebox.

Valve Conversion

RADVT Series Models

1.Turn control knob to the OFF position, and shut off the gas supply to the valve.

2.Allow the valve to cool to room temperature.

3.Remove the black protection cap by hand. (Fig. 61)

4.Insert a 5/32” or 4 mm Allen wrench into the hexagonal key-way of the screw (Fig. 62), rotate it counterclockwise until it

is free and extract it.

5.Check that the screw is clean and if necessary remove dirt.

6.Flip the screw.

(Fig. 63)

7.Using the Allen wrench as shown in Figure 64, rotate the screw clockwise and tighten until snug.

Figure 61

Figure 62

Figure 63

Figure 64

WARNING: Do not overtighten the

screw. Recommended to grip the wrench by the short side.

8.Verify that if the conversion is from NG to LP, the screw must be reassembled with the red o-ring visible. (Fig. 65)

Figure 65

 

Natural Gas

LP Configuration

Configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red O-ring Visible

 

 

 

Red O-ring NOT Visible

CO141

9. Replace the black protection cap.

WARNING: Check that also the pilot and main burner injectors are appropriate for

the gas type.

RADVTC Series Models

1. Follow procedure for pilot type 2 to replace pilot orifice.

3636

20012697

2.Remove and replace plug on lower right hand side of the valve; Red for LP and Blue for NG. (Page 32, Fig. 57)

3.Remove motor top cap using a standard slotted screwdriver. Depress and turn center plunger until arrow points to correct screw. Red for LP and Blue for NG. NOTE: Plunger will “snap” into NG position when arrow is close to blue screw. It will not “snap” at LP (Red) position. (Fig. 66)

 

 

Motor Top Cap

Center

 

 

Plunger

 

 

 

 

Valve

Blue - NG

Red - LP

LOCAL

FP1037b

 

 

 

Fig. 66 Depress and turn center plunger.

4.Insure manifold pressure remains between 3.2” - 3.5” w.c. for NG and 9.5” - 10” w.c. for LP. To adjust the manifold pressure, for NG, using a Torx #10 key turn the blue screw clockwise to increase the manifold pressure. Turn the screw counterclockwise to decrease the pressure. Use the red screw to adjust LP.

5.Replace motor top cap.

Pilot Orifice Conversion

1. Locate pilot. (Fig. 67)

Pilot

ST916

Fig. 67 Locate pilot.

2. Replace pilot orifice.

Pilot Type 1 (SIT Pilot)

Remove pilot hood by lifting up. (Fig. 68) Do not remove the snap ring to remove the pilot hood. NOTE: It is not necessary to remove the pilot tube for conversion.

Remove pilot orifice with Allen wrench. (Fig. 69)

Install the conversion orifice.

Reinstall pilot hood. Be sure to align hood with

index tab.

Radiance Direct Vent Gas Heater

Pilot Hood

Pilot

Bracket

CO105a

Fig. 68 Remove pilot hood.

Index Tab

Allen Wrench

 

Snap Ring

 

CO106a

 

Fig. 69 Remove pilot orifice.

Pilot type 2 (Honeywell Pilot)

Loosen pilot hood turning counterclockwise using a 7/16” wrench. (Fig. 70) NOTE: You may use penetrating oil to prevent pilot hood threads from seizing up.

Pilot Hood

Index

Marks

Pilot Bracket

CO143

Fig. 70 Remove pilot hood. (Your pilot may have a different appearance.)

Remove pilot orifice with needlenose pliers. (Fig. 71) NOTE: Use a wrench to hold pilot tube in place while removing the orifice.

Install the conversion orifice.

Reinstall pilot hood and tighten until mark on pilot hood aligns with mark on pilot bracket.

20012697

37

Radiance Direct Vent Gas Heater

Pilot

Orifice

CO1044

Fig. 71 Remove pilot orifice.

Burner Orifice Conversion

1.Remove three (3) 3/8” nuts on bottom side of burner pan. (Fig. 72)

2.Carefully remove ember bed by tilting the right side up and lifting out toward the right side of the unit. (Fig. 73)

Remove Nut

Bottom View

Remove Nuts

ST918

Fig. 72 Remove three (3) nuts securing ember bed in place.

Orifice

Venturi Bracket

Bracket

 

Pem Studs

ST919

Fig. 73 Tilt ember bed slightly to correctly place on venturi and air shutter.

3.Remove injector orifice from left burner bracket with a 1/2” wrench. Use a back up wrench to prevent damage to the manifold. (Fig. 74)

CO145

Fig. 74 Use two wrenches to avoid damage to manifold.

4.Install conversion orifice. (Refer to Table 2)

5.The air shutter is factory set according to Table 3 and should not need adjustment. The air shutter opening may be verified by measuring as shown in Figure 75.

Orifice

Orifice

Air Shutter

 

Bracket

 

 

CO142

Fig. 75 The air shutter setting is 1/2” (13 mm) from the orifice bracket to the edge of the air shutter.

All Models

1.Replace burner making sure venturi on bottom of ember bed aligns with orifice and is seated properly on air shutter assembly. (Fig. 73) Make sure burner is slid into place at a slight angle and opposite to how it was removed. When burner is slid into place, the three (3) pem studs should slide down through clearance holes into the bottom of the control panel.

2.Thread and tighten 3/8” nuts back onto pem studs on underneath side of control panel, reversing Step 1 shown in Figure 72.

3.Reinstall logs as per instructions on Page 26.

4.Place conversion label on valve.

3838

20012697

Radiance Direct Vent Gas Heater

5.Replace glass and stove front.

6.Restore gas to system and relight appliance according to Lighting Instructions on Page 30.

7.Leak check the system using a gas leak detector solution.

8.Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and operation.

Conversion is complete.

Table 2. Injector Orifice Size Matrix

Conversion to LP

 

 

 

 

 

 

 

 

Input (BTU/h)

 

Model

 

Kit #

 

Orifice

 

Part #

Minimum

 

Maximum

 

RADVT

 

20012729

 

1.75 mm

 

20012946

25,000

 

36,000

 

 

 

 

 

 

 

 

RADVTC

 

20012900

 

 

 

 

 

 

 

 

 

 

 

 

 

Conversion to Natural Gas

 

 

 

 

 

 

 

 

 

 

 

Input (BTU/h)

 

Model

 

Kit #

Orifice

Part #

Minimum

Maximum

 

RADVT

20012899

 

#31 / 0.120”

20006927

25,000

 

38,000

 

RADVTC

20012902

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 3. Air Shutter Adjustment

 

Natural Gas

Natural Gas

LP

Model

 

High Altitude

 

RADVT/RADVC

1/2” Open

1/2” Open

1/2” Open

Table 4. High Altitude Orifice

[Required for altitudes above 2000’ (610 m) up to 4500’ (1,370 m)]

 

 

 

Input (BTU/h)

Model

Orifice

Part #

Minimum

Maximum

RADVT/RADVTC

#33 / 0.113”

20012554

25,000

36,000

(Natural gas only)

 

 

 

 

*LP models do not need re-orificed up to 4500’ (1,370 m) above sea level.

20012697

39

Radiance Direct Vent Gas Heater

Maintenance

Your Radiance Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly.

Annual System Inspection

Have the entire heater and venting system inspected annually by a qualified gas technician. Replace any worn or broken parts.

Logset and Burner /

Cleaning and Inspection

Cleanliness is critical to the proper function of the heater. The logset and burner must all be kept free of dust and unobstructed by debris. Inspect these areas before each use and clean as necessary.

1.Turn the burner OFF and let the heater cool completely before cleaning.

2.Lift the Stove Front up and then swing the bottom out to disengage it from the heater shell. (Fig. 76)

3.Carefully remove the glass and frame assembly and place it out of the way on a flat, padded surface such as a counter protected by a towel.

4.Carefully inspect the Logs for damage. Contact your local dealer if any damage is evident.

5.Use a soft bristled brush to sweep dust or debris from the Logs, Pilot and Burner. Use care as the logs are fragile and susceptible to damage.

6.Replace the glass panel and frame assembly.

7.Replace the Stove Front.

Care of Cast Iron

An occasional dusting with a dry rag will help keep the painted surfaces looking new. Use high-temperature stove paints, available through your local dealer, to touch-up areas as needed. Clean areas to be painted with a wire brush and be sure to cover the logs, burner and valve assembly, glass and frame assembly. Apply the paint sparingly; two light coats of paint will give better results than a single heavy coat.

Clean porcelain enamel surfaces with a soft, damp cloth. Do not use abrasive cleaning agents. If necessary, use only a cleaning agent formulated especially for use on porcelain enamel surfaces.

CAUTION

TURN THE PILOT OFF BEFORE PAINTING. ALLOW THE HEATER TO COOL COMPLETELY BEFORE PAINTING.

Cleaning the Glass

WARNING: Allow the glass to cool completely before attempting to clean.

It will be necessary to clean the glass periodically. During start-up, condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a non-ammonia household cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleaned two or three times during each heating season depending on the circumstances present.

Clean glass after first two weeks of operation.

Glass Replacement

Replace glass only with CFM Corporation approved parts. Refer to Page 43 for Replacement Parts. Refer to Figure 77 and previous instructions for removal of the damaged glass frame.

ST139a

Fig. 76 Remove the Stove Front.

4040

20012697

Figure 79

ST141

Fig. 77 Release the latches to remove the glass frame.

Gasket Replacement

The Radiance Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer.

Shut off the gas supply and allow the stove to cool. Wear safety goggles and a dust mask.

1.Remove the Front, Glass Frame and Glass Panel.

(Figs. 76 & 77) Remove the old gasket. Use a razor blade to separate the glass and gasket from the frame, and to clean the glass of any remaining cement or bits of gasket. Use a cold chisel if necessary.

2.Determine the correct length of gasket by laying it out around the edge of the glass. Allow an extra 1

- 2” (25-50mm). Mark the spot to be cut. Use a utility knife.

3.Starting on a long edge, remove about 6” of the protective paper strip and apply the flat adhesive

face of the gasket around the outside-facing edge of the panel. Continue around the panel, applying about 6” at a time and being

careful to not stretch the material. Do not overlap the gasket ends. (Fig. 78)

4.Apply a thin bead of high temperature silicone rubber sealant along the inside

Radiance Direct Vent Gas Heater

 

ST179

Fig. 78

Wrap the gasket material around the outside edge of

the glass.

corner of the glass frame, all around the perimeter. Place the flat gasketed side of the glass panel back into the steel frame. Pinch the rounded inside-facing gasket material to bulk it up.

5.Replace the glass frame and front panel as previously described.

Inspect the Vent System Annually

Have the vent system inspected annually by a qualified technician. Shut off the main gas supply before inspecting the system. Both the inner exhaust pipe and the outer combustion supply pipe must be checked to confirm that they are unblocked and in good condition.

Check the Gas Flame Regularly

To ensure that the stove is operating properly, check the flames periodically to confirm they match Figure 79. The flames will be blue during the first 15-20 minutes of operation, and will gradually turn to yellow after that.

Do not use your stove if the flame pattern differs from that shown here. Contact your Vermont Castings dealer or a qualified technician for help.

LG491

20012697

41

Radiance Direct Vent Gas Heater

Wiring Diagrams

OFF ON

On/Off Switch

Wiring

Black

TP/TH

TP

TH

opile Therm

Black

ST124b

Thermostat

Optional Thermostat (Optional)

Wiring

Black

TP/TH

TP

TH

Thermopile

Black

ST124c

Fig. 80 On/off switch and optional thermostat circuit.

NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED WITH THE APPLIANCE, MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE SF-2, 200°C WIRE OR ITS EQUIVALENT.

FAN

POWER

CORD

WHT BLK

BLK

Chassis

GRN

 

 

Ground

 

 

 

 

 

K

 

 

L

 

 

B

 

BLK

 

 

 

FAN JUNCTION BOX

Strain Relief

ON / OFF

Rheostat

Snapstat

 

K

WHT

 

 

L

BLK

B

 

 

 

GRN

Chassis Ground

RHEOSTAT / SNAPSTAT

 

 

BOX

ST153

MOTOR

Schematic Diagram

 

BLK

BLK

BLK

 

 

 

BLK

SNAPSTAT

WHT

WHT

GRN

RHEOSTAT

 

 

ON/OFF

 

 

ST236

Fig. 81 Fan circuit.

4242

20012697

Radiance Direct Vent Gas Heater

1

1a

 

 

 

5

 

 

 

 

 

 

 

 

1b

 

4

1c

 

 

 

 

3

 

 

 

 

1e

 

 

1d

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

2

 

15

 

 

 

19

14

 

 

16

 

 

 

 

 

 

 

 

 

 

17

 

 

 

 

 

18

 

 

 

 

 

27b

 

25

 

 

13

 

 

 

 

 

 

 

 

 

 

26a,b

38

 

 

 

 

 

 

 

 

PILOT OFF

 

 

 

 

 

 

 

 

 

 

ON•

 

42

 

LOCAL

REMOTE

 

 

 

LED

 

 

44

50

7 8

6

11

9

22

 

 

21

20

 

 

 

 

 

24

 

 

 

 

23

 

 

 

 

12

29

30

28

31

34

27a

 

 

 

 

 

27c

 

 

 

 

32

 

 

 

35a,b

36a,b

33

 

37a,b,c

 

 

 

40

 

 

41

46

47

48

43

45

CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.

Radiance Direct Vent Gas Heater

Models: RADVT Series: RADVTCB, RADVTEB, RADVTMB, RADVTBS, RADVTCH, RADVTVG, RADVTBD, RADVTBB, RADVTC Series: RADVTCG, RADVTGG, RADVTSG, RADVTCCB, RADVTCEB, RADVTCMB, RADVTCBS, RADVTCCH, RADVTCVG, RADVTCBD, RADVTCBB, RADVTCCG, RADVTCSG

20012697

43

Radiance Direct Vent Gas Heater

Radiance Direct Vent Gas Heater (continued)

Models: RADVT Series: RADVTCB, RADVTEB, RADVTMB, RADVTBS, RADVTCH, RADVTVG, RADVTBD, RADVTBB, RADVTC Series: RADVTCG, RADVTGG, RADVTSG, RADVTCCB, RADVTCEB, RADVTCMB, RADVTCBS, RADVTCCH, RADVTCVG, RADVTCBD, RADVTCBB, RADVTCCG, RADVTCSG

Ref.

Description

RADVT/RADVTC

1.

Log Set - Complete

20012550

1a.

Log, Rear

20012541

1b.

Log, Right Front

20012543

1c.

Log, Left Front

20012542

1d.

Left Cross Log

20012544

1e.

Right Cross Log

20012545

2.

Ember Bed Assembly

20012206

3.

Top

Refer to Enamel Parts Chart

4.

Screen, Top

1601970

5.

Grille

1301195

6.

Front II

Refer to Enamel Parts Chart

7.

Door, Left

Refer to Enamel Parts Chart

8.

Door, Right

Refer to Enamel Parts Chart

9.

Control Door

Refer to Enamel Parts Chart

10.

Left End

Refer to Enamel Parts Chart

11.

Right End

Refer to Enamel Parts Chart

12.

Leg

Refer to Enamel Parts Chart

13.

Glass Frame Assembly

5003075

14.

Frame, Glass

1409112

15.

Gasket, Glass Med. Knit

1203702

16.

Glass, GFP Firebox

1601290

17.

Wood Handle

1600664

18.

Pan Hd, Sl 1/4-20 x 3-Z

1201310

19.

Brushed Nickel Insert

30002714

20.

Control Door Handle Assembly

30002730

21.

Washer, Flat 1/4 - Blk. 266 x .629.064

1202473

22.

CS, Hex Hd 1/4-20 x 5/8” - Blk

1201372

23.

Latch, Front Door

30001249

24.

FK26 Fan Subassembly (RADVTC Series Only)

30000879

25.

Valve Nova SIT820.852 (RADVT Series Only)

20012218

26a.

Valve Gas Honeywell Convertible RFN RV8310E

20003719

26b.

Valve Gas Honeywell Convertible RFP RV8310E

20003720

27a.

Pilot Assembly 3Way N/DV RN 0.199.706

10002264

 

Pilot Assembly 3Way N/DV RP 0.199.703

10002265

27b.

PIlot PSE - NA175

20001115

 

Pilot PSE - LP175

20001116

27c.

Pilot Assembly 3Way DV/RFN CS3003A2009

20002266

 

Pilot Assembly 3Way DV/RFP CS3003A2017

20002268

28.

Pilot Top Convertible

10002266

29.

Thermocouple 24”

53373

 

 

7531137

30.

Electrode Ignitor w/ Cable SIT24

10001297

31.

Thermopile 18” RS

51827

 

 

7533113

32.

Nut Electrode SIT #0.974.144

57886

33.

Tubing Pilot w/ Fitting 1/8 x 24”

10001296

34.

Thermopile PSE fro RF Pilots

20002400

35a.

Pilot Orifice #62 - NG Top Convertible

10002268

4444

20012697

Radiance Direct Vent Gas Heater

Radiance Direct Vent Gas Heater (continued)

Models: RADVT Series: RADVTCB, RADVTEB, RADVTMB, RADVTBS, RADVTCH, RADVTVG, RADVTBD, RADVTBB, RADVTC Series: RADVTCG, RADVTGG, RADVTSG, RADVTCCB, RADVTCEB, RADVTCMB, RADVTCBS, RADVTCCH, RADVTCVG, RADVTCBD, RADVTCBB, RADVTCCG, RADVTCSG

Ref.

Description

RADVT/RADVTC

35b.

Pilot Orifice #35 - LP Top Convertible

10002269

36a.

PIlot Orifice PSE RFN

20000908

36b.

PIlot Orifice PSE RFP

20000907

37a.

Orifice Hood 1.75 mm LP

20012946

37b.

Orifice Hood #31 (0.120”) Natural

20006927

37c.

Orifice - High Altitude #33 (0.113”) Natural

20012554

38.

Ignitor Piezo w/ Nut SIT

52464

39.

Bracket Piezo Ignitor (not shown)

20010876

40.

Manifold Assembly

20012202

41.

Air Shutter Assembly

20012204

42.

Trim ON/OFF Switch

30000874

43.

Transmitter Honeywell RF

20002047

44.

Antennae, Honeywell 395783-1

20003561

45.

Wire w/ Straight Term 2 End 50”

10002582

46.

Sensor 2450 CMG-8184-0032

10002013

47.

Gasket Base Pan

20004287

48.

Gasket, HE Door

1203687

49.

Gasket Cement, 3 oz. Tube (not shown)

1206122

50.

Restrictor Plate

20013028

Fuel Conversion Kits

Conversion Kit, NG to LP - RADVTC

Kit 20012900

Conversion Kit, NG to LP - RADVT

Kit 20012729

Conversion Kit, LP to NG - RADVTC

Kit 20012902

Conversion Kit, LP to NG - RADVT

Kit 20012899

High Altitude Conversion Kit

Kit 20013135

20012697

45

Radiance Direct Vent Gas Heater

Radiance Direct Vent Gas Heater (continued)

Models: RADVT Series: RADVTCB, RADVTEB, RADVTMB, RADVTBS, RADVTCH, RADVTVG, RADVTBD, RADVTBB, RADVTC Series: RADVTCG, RADVTGG, RADVTSG, RADVTCCB, RADVTCEB, RADVTCMB, RADVTCBS, RADVTCCH, RADVTCVG, RADVTCBD, RADVTCBB, RADVTCCG, RADVTCSG

Shell Enamel Parts - Radiance Direct Vent

Enamel

Model

Top

Left

Right

Front

Left

Right

Control

Leg

Color

 

 

End

End

 

Door

Door

Door

(4)

Classic

RADVTCB

1301194

30001751

30001752

30001376

30001378

30001377

30001413

30001753

 

RADVTCCB

 

 

 

 

 

 

 

 

Biscuit

RADVTBS

30003244

30003239

30003238

30003240

30003242

30003241

30003243

30003245

 

RADVTCBS

 

 

 

 

 

 

 

 

Bordeaux

RADVTBD

2321194

30001771

30001770

30001416

30001418

30001417

30001419

30001772

 

RADVTCBD

 

 

 

 

 

 

 

 

Chestnut

RADVTCH

30003253

30003248

30003247

30003249

30003251

30003250

30003252

30003254

Brown

RADVTCCH

 

 

 

 

 

 

 

 

Ebony

RADVTEB

30003262

30003257

30003256

30003258

30003260

30003259

30003261

30003263

 

RADVTCEB

 

 

 

 

 

 

 

 

Midnight

RADVTMB

2371194

30001777

30001776

30001424

30001426

30001425

30001427

30001778

Blue

RADVTCMB

 

 

 

 

 

 

 

 

Vermont

RADVTVG

30003271

30003266

30003265

30003267

30003269

30003268

30003270

30003272

Cl. Green

RADVTCVG

 

 

 

 

 

 

 

 

Brick Blue

RADVTBB

30003592

30003587

30003586

30003588

30003590

30003589

30003591

30003595

 

RADVTCBB

 

 

 

 

 

 

 

 

Country

RADVTCG

30003603

30003598

30003597

30003599

30003607

30003600

30003602

30003606

Cookware

RADVTCCG

 

 

 

 

 

 

 

 

Gray

 

 

 

 

 

 

 

 

 

Granite

RADVTGG

30003614

30003609

30003608

30003610

30003612

30003611

30003613

30003617

Gray

RADVTCGG

 

 

 

 

 

 

 

 

Sage

RADVTSG

30003625

30003620

30003619

30003621

30003623

30003622

30003624

30003628

Green

RADVTCSG

 

 

 

 

 

 

 

 

4646

20012697

Radiance Direct Vent Gas Heater

Optional Accessories

Fan Kits

FK26 Fan

The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox temperature rises above and falls below a preset temperature. A rheostat provides for variable fan speeds.

Specifications

115 Volt / 60Hz / .75 Amps

Maintenance

The fan itself does not require regular maintenance, however, periodic cleaning of the fan and the surrounding area is required.

Installation

Refer to Page 15 for installation instructions.

Remote Controls

The remote control allows you to turn the heater on or off from anywhere in the room. Refer to Page 43 for wiring diagrams. These remote controls are for use with RN/RP models.

Model

Functions Controlled

RC1

ON/OFF

RC2

ON/OFF and Temperature

IMTFK

Wall mounted thermostat control

Screen Kit

An optional screen, R40SK, for use with the operable doors is available to allow the doors to be left in the open position.

Warming Shelf

Warming shelves add versatility to your stove; they can be used to keep foods warm at mealtime.

Model

Color

1560

Classic Black

1555

Biscuit

1556

Chestnut Brown

1557

Ebony

1558

Vermont Classic Green

1562

Sand

1565

Bordeaux

1566

Forest Green

1567

Midnight Blue

1568

Suede Brown

30220

Brick Blue

30222

Country Cookware Gray

30223

Granite Gray

30224

Sage Green

The shelf installation is done in three stages. First you attach the shelf loosely to the stove, leaving the screws loose enough to allow final adjustments. Then, you position the shelf and adjust the brackets so the shelf fits correctly. Finally, you tighten the screws.

Refer to the instructions included with each warming shelf for complete installation procedures.

Decorative Rings

7” brass or charcoal gray rings are available to add a decorative touch to the exposed stove pipe.

Model

Description

7FSDRG/4

7” Charcoal Gray Rings (4)

7FSDRP/4

7” Polished Brass Rings (4)

20012697

47

Radiance Direct Vent Gas Heater

4848

20012697

Radiance Direct Vent Gas Heater

20012697

49

Radiance Direct Vent Gas Heater

5050

20012697

LIMITED LIFETIME WARRANTY

PRODUCT COVERED BY THIS WARRANTY

All Vermont Castings brand gas stoves, gas inserts, and gas fireplaces installed in the United States of America or Canada.

LIMITED LIFETIME WARRANTY

CFMCorporation(hereinafterreferredtoasCFM)warrantsthatall castironparts,thecombustionchamber,ceramicburner,andheat exchanger of every Vermont Castings gas product will be free of defective material or workmanship during the period the product is owned by the original owner subject to proof of purchase and the conditions and limitations listed on this warranty document.

BASIC ONE-YEAR WARRANTY

CFMwarrantstotheoriginalownerthatyournewVermontCastings Gas Appliance is free from defects in material or workmanship for a period of one year from the date of purchase, subject to the following conditions and limitations. Labor to replace these parts is covered for one year, reimbursed per our warranty service fee schedule.

COMPONENT WARRANTY LIMITATATIONS

PORCELAINENAMELFINISHEDPARTS: CFMoffersnowarrantyon chippingofenamelsurfaces.Inspectallproductspriortoaccepting them for any damage to the enamel. The salt air environment of coastal areas or a high humidity environment can be corrosive to the porcelain enamel finish. These conditions can cause rusting of the cast iron beneath the porcelain enamel finish, which will cause the finish to flake off. Color lot variations with parts and/or accessories can occur and are not covered by warranty.

GLASS:Glassisnotwarrantedforbreakageduetomisuseoraccident. Glassisnotcoveredfordiscolorationorstainsduetoenvironmental issues, or improper cleaning and maintenance.

PLATED PARTSANDACCESSORIES: Brass, nickel, and gold parts shouldbecleanedwithLemonoilonly.Commercialcleanerscannot be used. Mortar mix and masonry cleaners corrode the brass finish. The CFM will not be responsible for, nor will it warrant any brass parts which are damaged by external chemicals or down draft conditions.

ACCESSORIES: Unless otherwise noted, CFM supplied accessories are covered for a period of one year.

GENERAL CONDITIONS AND LIMITATIONS

This Vermont Castings product must be installed or serviced by a qualified installer, preferably NFI or WETT (Canada) certified, as prescribed by the local jurisdiction. It must be installed and operated at all times in accordance with the Installation and Operating instructions furnished with the product. Any alteration, willful abuse, accident, or misuse of the product shall nullify this warranty.

This warranty is non-transferable, and is made to the original owner,providedthatthepurchasewasmadethroughanauthorized supplier of Vermont Castings branded CFM products.

Parts covered under the Limited Lifetime Warranty will be covered for the lifetime of the appliance up to a maximum of seven (7) years after CFM discontinues the model. The maximum amount recoverable under this warranty is limited to the purchase price of the product and, if CFM is unable to provide replacement or repair in an expedient and cost effective manner, CFM may discharge all obligations under this warranty by refunding the purchase price of the product.

Any labor and related repair charges relating to the cost and expenses of replacing or repairing defective components under the Limited Lifetime Warranty are not covered, except as provided for under the Basic One-Year Warranty.

Any part or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty, whichever is longest.

Anyinstallation,labor,construction,transportation,orotherrelated costs/expensesarisingfromdefectivepart(s),repair,replacement, orotherwiseofsame,willnotbecoveredbythiswarranty,norshall theCompanyassumeresponsibilityforsame.INNOEVENTSHALL

CFMBELIABLEFORANYINCIDENTALORCONSEQUENTIAL DAMAGES CAUSED BY DEFECTS IN THE PRODUCT except as provided by law

SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLYTOYOURCIRCUMSTANCES. THISWARRANTYGIVES YOU SPECIFIC RIGHTSAND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.

Allotherwarrantiesexpressedorimpliedwithrespecttotheproduct, its components and accessories, or any obligations/liabilities on the part of the Company are hereby expressly excluded.

The Company neither assumes, nor authorizes any third party to assume on its behalf, any other liabilities with respect to the sale of this Vermont Castings product

The warranties as outlined within this document do not apply to chimney components or other non CFM Corporation accessories used in conjunction with the installation of this product.

Damage to the unit while in transit is not covered by this warranty but is subject to claim against the common carrier. Contact the dealer from whom you purchased your fireplace/stove (do not operate the appliance as this might negate the ability to process the claim with the carrier).

The Company will not be responsible for:

a)Down drafts or spillage caused by environmental conditions such as near-by trees, buildings, roof tops, hills, or mountains.

b)Inadequate ventilation or negative air pressure caused by mechanical systems such as furnaces, fans, clothes dryers, etc.

This warranty is void if:

a)The fireplace has been operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals.

b)Thefireplacehasbeensubjectedtoprolongedperiodsofdampness or condensation

c)Any damages to the fireplace, combustion chamber, heat exchanger or other components due to water, or weather damage, which is the result of but not limited to, improper chimney/venting installation.

d)Any alteration, willful abuse, accident, or misuse of the product has occurred.

IF WARRANTY SERVICE IS NEEDED...

Contact your installing Vermont Castings dealer. Make sure you have your warranty, your sales receipt, the model number and serial number of your CFM product. If you’re the installing dealer is unknown or unable to provide necessary parts or service, a list of Authorized Vermont Casting dealers can be located on the internet at www.vermontcastings.com

20012697