Veris V645 Installation Instructions

REL AY S
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• Follow safe electrical work practices.
See NFPA 70E in the USA, or applicable local codes.
• This equipment must only be installed and serviced by qualied electrical personnel.
• Read, understand and follow the instructions before installing this product.
• Turn o all power supplying equipment before working on or inside the equipment.
• Use a properly rated voltage sensing device to conrm power is o. DO NOT DEPEND ON THIS PRODUCT FOR VOLTAGE INDICATION
Failure to follow these instructions will result in death or serious injury.
DANGER
TM
INSTALLATION GUIDE
V645
V645
10A SPDT Mini Command Relay
Installer’s Specifications
Operating Temperature -0°C to 60°C (-32° to 140°F) Operating Humidity 10-90% non condensing Expected Relay Life Electrical (at rated current): 100,000 cycles Mechanical (unpowered): 10,000,000 cycles Relay Status LED ON=energized Insulation Class 277 VAC RMS
Wire Specications:
Lead Length 10” (254mm) min. Gauge UL1015; Coil: 18AWG; Contacts: 16AWG Agency Approvals UL508 enclosed device listing, pollution degree 2
INSTALLATION
Disconnect and lock out all power sources before beginning the installation.
1. Mount the unit using the DIN rail clip or the screw.
2. Connect coil:
NOTICE
• This product is not intended for life or safety applications.
• Do not install this product in hazardous or classified locations.
• The installer is responsible for conformance to all applicable codes.
• Mount this product inside a suitable fire and electrical enclosure.
DIMENSIONS
1.1”
(28 mm)
0.6
(14 mm)
0.5
(13 mm)
1.2
(30 mm)
1.3”
(33 mm)
1.1
(28 mm)
• Choose the coil common lead (white with yellow stripe) and connect it to the common (-) source termination point.
• Choose either the low voltage (24-30 VAC/DC, white with blue stripe) or high voltage (120 VAC, white with black stripe) lead, depending on the application requirements, and connect it to the (+) source termination point.*
3. Connect relay contacts:
• Choose the relay common wire (yellow) and connect to the switched load.
• Choose the relay N.O. (orange) or N.C. (blue) lead* and connect to the
switched load.
4. Secure the enclosure and reconnect power.
* Isolate or insulate all non-terminated wires according to local electrical code requirements, i.e. wire nut.
Ø 0.15”
ZL0012-0C PAGE 1 ©2012 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 05123
Alta Labs, Enercep t, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘ V’ logo are trademark s or registered tradema rks of Veris Industries, L.L .C. in the USA and /or other count ries.
(4 mm)
V645
Voltage Coil Current AC DC
24-30V................................. 32mA 13mA
120V...................................... 17mA
TYPICAL COIL PERFORMANCE
Resistive................. 10A@250VAC, N.O.
7A@250VAC, N.C. 6A@277VAC 7A@30VDC
Motor..................... 125VAC, 1/4 HP, N.0.
CONTACT RATINGS
TM
INSTALLATION GUIDE
WIRING COLOR CODES
CONTACT OUTPUTCONTROL SYSTEM INPUT
wht/black
LOW
wht/blue
COMM
wht/yellow
b
l
a
HI
b
l
y
e
ll
c
White
k
120VAC
ue
White
24VAC/DC
o
White
w
Common
b
bl
l
a
a
c
c
k
k
b
l
ue
y
e
ll
o
w
N.C.
YELLOW
Common
ORANGE
N.O.
CONTACT AND COIL SPECIFICATIONS
WIRING EXAMPLE
PANEL
V645
To Load
Coil
PANEL
V645
To Load
Coil
24V
24V
120V
120V
DIGITAL
CONTROL
POWER
SOURCE
ZL0012-0C PAGE 2 ©2012 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 05123
Alta Labs, Enercep t, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘ V’ logo are trademark s or registered tradema rks of Veris Industries, L.L .C. in the USA and /or other count ries.
Loading...