Veris V200 Datasheet

Pull in Voltage AC DC
10-30V..................................... 8 9
120V........................................ 78
208-277V................................. 154
Drop Out Voltage AC DC
10-30V..................................... 2 3
120V........................................ 18
208-277V................................ 36
Voltage Coil Current AC DC
10V.......................................... 25mA 14mA
12V.......................................... 25mA 14mA
24V.......................................... 31mA 16mA
30V.......................................... 39mA 18mA
120V........................................ 22mA -
208V........................................ 19mA
277V........................................ 25mA
TYPICAL COIL PERFORMANCE
CONTACT RATINGS
Resistive.............. 10A@277VAC, 28VDC
Motor.................... 120VAC, 1/3HP N.O. & 1/6HP N.C.
240VAC, 1/3HP N.O. & 1/6HP N.C. 277VAC, 1/4HP N.O. & 1/8HP N.C.
Pilot Duty............. 277VAC, (1.7A), 480VA N.O.
Ballast.................. 277VAC, 1.7A
Tungsten............... 120VAC, TV3 N.O. TV2 N.C.
Gold Flash............. Yes
VICTORY 100 & 200 SERIES
Enclosed Victory Relays: 10A SPDT
Great For External
VERIS INDUSTRIES
Mount Applications
DESCRIPTION
APPLICATIONS
Command contactors
Control motors
Isolation
Device interlocking
Relay logic
Sense voltages for alarm conditions
RELAYS
V100 V200D
FEATURES
Sleek eld enclosure reduces the need for panel space
The nipple mount feature allows the Victory Series to be mounted to any
electrical enclosure
Flexible tinned stranded wire...ts easily in tight spaces & provides secure
connections to wire nuts
UL508 Listed...designed and approved for eld installation...makes electrical
inspection a snap
Run low voltage instead of line voltage...eliminate conduit in some applications
SPECIFICATIONS
Operating Temperature Range:
V100, V100DC, V200 -34° to 60°C (-29° to 140°F) V100D, V200D -40° to 55°C (-40 ° to 131°F) Operating Humidity Range 10-90% RH non-condensing Expected Relay Life Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles Relay Status LED ON=energized
Wire Specications:
Lead Length 14” (356 mm) min. Gauge UL1015; Coil: 18 AWG; Contacts: 16 AWG Insulation Class 60 0VAC RM S Agency Approvals UL 508
800.354.8556
Year
5
Warranty
+1 503.598.4564
www.veris.com
HQ0001833.B 01131
800.354.8556
To Load
To Controls
C
O
N
T
A
C
T
S
COIL
To Load
To Controls
Wire Nut
C
O
I
L
CONTACTS
CONTACT OUTPUT
CONTROL SYSTEM INPUT
E150462
+1 503.598.4564
www.veris.com
APPLICATION/WIRING EXAMPLES
Nipple mount directly to a panel
Nipple mount to any 2x or 4x electrical box
DIMENSIONAL DRAWINGS
V100/V100DC/V200
2.9"
(74 mm)
2.8"
(71 mm)
(43 mm)
1/2" NPT Nipple
4.0"
(103 mm)
3.8"
(97 mm)
V100D/V200D
1.7"
1.6"
(41 mm)
2.0"
(52 mm)
1.8"
(46 mm)
WIRE COLOR CODES
HI
wht/brown
HI
wht/black
LOW
wht/blue
COMM
wht/yellow
ORDERING INFORMATION
MODEL RELAY COIL AMPERAGE RATING RELAY POWER LED UL
V100* SPDT 10-30VAC/DC, 120VAC
V100D 2x SPDT 10-30VAC/DC, 120VAC
V100DC SPDT 10-30VDC
V200 SPDT 10-30VAC/DC, 208-277VAC
V200D 2x SPDT 10-30VAC/DC, 208-277VAC
Some devices are Plenum rated per UL 1995...see White Paper VWP01 at veris.com for details. * Optional domestic version available.
HQ0001833.B 01131
br
o
208-277VAC
b
l
a
b
l
y
e
ll
w
White
n
c
White
k
120VAC
ue
White
10-30VAC/DC
o
White
w
Common
br
o
w
n
b
bl
l
a
a
c
c
k
k
b
l
ue
y
e
ll
o
w
Primar y
or
*
*Isolation…600VAC
2.3"
(59 mm)
2.5"
(64 mm)
3/4" NPT Nipple
Relay 2 on V100D and V200D only
RELAYS
CONTACT OUTPUTCONTROL SYSTEM INPUT
N.C.
YELLOW
Common
ORANGE
N.O.
10A
HI
wht/orange
HI
wht/red
LOW
grey/wht
COMM
wht/violet
n n
n n
n n
n n
n n
o
ra
ng
208-277VAC
10-30VAC/DC
Common
e
120VAC
o
ra
ng
e
or
*
*Isolation…600VAC
N.C.
Common
N.O.