Hot Tap Models
V200 Screw Drive
Threaded Components
Differential Pressure Flow Sensors
Verabar
®
V200 Hot Tap
Pipe Connection Threaded (NPT)
Mounting Type Ball or gate access valve
• Most commonly used hot tap model
• Installation, insertion & retraction without system shutdown
• Economical single threaded rod for most applications
• Two threaded rods for high pressures
Features and
• Synchro drive simultaneously rotates both rods
Benefits
(double rod drives only)
• Patented, anti-seize orbital bearing aligns threaded rods
and eliminates galling
• Can mount to existing valves
• Air (compressed, combustion)
Applications
• Natural gas
• Water (raw, cooling, feedwater)
• Steam
Special Designs—
• Custom mounting, lengths, materials,
Consult Factory
instrument connections, etc.
• Short straight run
Temperature
Pressure
Limits
(ANSI Class Rating)*
150 #
275 psig @ 100°F
(19 Bars @ 38°C)
80 psig @ 800°F
(5.5 Bars @ 426°C)
600#
1440 psig @ 100°F
(99.3 Bars @ 38°C)
825 psig @ 800°F
(56.9 Bars @ 426°C)
Model Specifications V200S V200D
Sensor Code 05 10 15 10 15
Sensor Diameter 7/16” (11mm) 7/8” (22mm) 1-3/8” (35mm) 7/8” (22mm) 1-3/8” (35mm)
Accuracy ±1% of flow rate; ±0.5% if calibrated
ANSI Class* 600# 150# 150# 600# 600#
Drive Rods Single Double
Pipe Size
2”- 6” 6”- 42” 12”-60” 6”-42” 12”- 60”
(50mm-150mm) (150mm-1050mm) (300mm-1500mm) (150mm-1050mm) (300mm-1500mm)
Instrument Connection 1/2” NPT 1/2” NPT or Direct Mount 1/2” NPT or Direct Mount
Components Furnished Weld coupling, close nipple, access nipple and valve
Weld Coupling Size 3/4” NPT 1-1/4” NPT 2” NPT 1-1/4” NPT 2” NPT
The Most Accurate and Reliable Technology
for Measuring Gas, Liquid and Steam…
Developed from aerospace technology,
the Verabar® averaging pitot flow
sensor provides unsurpassed
accuracy and reliability.
With its solid, one-piece
construction and bullet
shape, the Verabar
makes flow
measurement
leak proof
and precise.
The unique
sensor shape
reduces drag and flow induced vibration. The location
of the low-pressure ports eliminates the potential for
clogging and improves signal stability.
Model
V200D
Model
V200S
* DIN and JIS flanges available. Consult factory.