TM
OCCUPANCY SENSORS
AA47 AA47
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• Follow safe electrical work practices. See NFPA 70E in the USA, or applicable local codes.
• This equipment must only be installed and serviced by qualied electrical personnel.
• Read, understand and follow the instructions before installing this product.
• Turn o all power supplying equipment before working on or inside the equipment.
• Use a properly rated voltage sensing device to conrm power is o.
DO NOT DEPEND ON THIS PRODUCT FOR VOLTAGE INDICATION
Failure to follow these instructions will result in death or serious injury.
OPERATION
The AA47 Line-Switching Power Pack provides local switching capability to control
loads based on the signal from MSC Series occupancy sensors, independently of any
connection to building control systems. The AA47 routes 120/277 VAC, 60 Hz line
power directly to a Form A relay contact (SPST, normally open) to control a load,
and it generates full-wave, 24 VDC to power up to four MSC sensors (depending on
model). The relay is rated for maximum 15 A tungsten and 20 A ballast loads.
Mounted the AA47 either inside or outside a standard junction box using a 1/2-in.,
threaded EMT nipple. Route power to the sensor(s) using plenum-rated cable.
MOUNTING OPTIONS
INSIDE
INSTALLATION GUIDE
Line Switching Power Pack
Installer’s Specifications
Storage Temperature -29° to 65°C (-20° to 150°F )
Operating Temperature 0° to 40°C (32° to 104°F)
Maximum Humidity 90% RH non-condensing
AC Power Input 120/277 VAC ± 10%, 60 Hz
Output Voltage 24 VDC
Output Current 100 mA max.
Relay Contac ts:
Horsepower Rating 1 HP@120V
Switching Capacity 120 VAC, 60 Hz; 15 A tungsten 1800 W
277 VAC, 60 Hz 20 A Ballast
INSTALLATION
1. Provide separate overcurrent protection in accordance with the National Electrical
Code® and applicable local codes.
2. Use copper wire only.
3. Conrm that the device rating is appropriate for your application.
4. Set the voltage selector on the front of the unit to either 120 or 277 V, depending
on your application. The unit is shipped with the selector set to 277 V.
5. Mount the power pack to a suitable junction box using the 1/2-in., threaded nipple
and lock. The power pack is plenum-rated, and can be mounted to the inside or
the outside of a junction box or xture in a ceiling plenum.
6. Connect the power pack as shown. Use approved wire nuts for electrical
connections.
SCHEMATIC DIAGRAM
Hot
Line Voltage
120/277 VAC
Neutral
Voltage
Selector
Black
White
Relay
Load
Red
Transformer
Control
Red
(+24 VDC)
Black
(Common)
Blue
(Control)
Line Voltage
From Sensor Output
OUTSIDE
From Sensor Output
Line Voltage
SYSTEM DIAGRAM
Voltage Selector
Hot
Line Voltage
120/277VAC
Neutral
Load
BLK
White
RED
Ext. Override OFF
120V
277V
+24VDC
Common
Control Input
BLUE
Sensor
REDBLK
ZL0033-0B PAGE 1 ©2012 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 03121
Alta Labs, Enercep t, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘ V’ logo are trademark s or registered tradema rks of Veris Industries, L.L .C. in the USA and /or other count ries.