Veris AA47 Installation Instructions

TM
OCCUPANCY SENSORS
AA47 AA47
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• Follow safe electrical work practices. See NFPA 70E in the USA, or applicable local codes.
• This equipment must only be installed and serviced by qualied electrical personnel.
• Read, understand and follow the instructions before installing this product.
• Turn o all power supplying equipment before working on or inside the equipment.
• Use a properly rated voltage sensing device to conrm power is o. DO NOT DEPEND ON THIS PRODUCT FOR VOLTAGE INDICATION
Failure to follow these instructions will result in death or serious injury.
OPERATION
The AA47 Line-Switching Power Pack provides local switching capability to control loads based on the signal from MSC Series occupancy sensors, independently of any connection to building control systems. The AA47 routes 120/277 VAC, 60 Hz line power directly to a Form A relay contact (SPST, normally open) to control a load, and it generates full-wave, 24 VDC to power up to four MSC sensors (depending on model). The relay is rated for maximum 15 A tungsten and 20 A ballast loads.
Mounted the AA47 either inside or outside a standard junction box using a 1/2-in., threaded EMT nipple. Route power to the sensor(s) using plenum-rated cable.
MOUNTING OPTIONS
INSIDE
INSTALLATION GUIDE
Line Switching Power Pack
Installer’s Specifications
Storage Temperature -29° to 65°C (-20° to 150°F ) Operating Temperature 0° to 40°C (32° to 104°F) Maximum Humidity 90% RH non-condensing AC Power Input 120/277 VAC ± 10%, 60 Hz Output Voltage 24 VDC Output Current 100 mA max.
Relay Contac ts:
Horsepower Rating 1 HP@120V Switching Capacity 120 VAC, 60 Hz; 15 A tungsten 1800 W 277 VAC, 60 Hz 20 A Ballast
INSTALLATION
1. Provide separate overcurrent protection in accordance with the National Electrical Code® and applicable local codes.
2. Use copper wire only.
3. Conrm that the device rating is appropriate for your application.
4. Set the voltage selector on the front of the unit to either 120 or 277 V, depending on your application. The unit is shipped with the selector set to 277 V.
5. Mount the power pack to a suitable junction box using the 1/2-in., threaded nipple and lock. The power pack is plenum-rated, and can be mounted to the inside or the outside of a junction box or xture in a ceiling plenum.
6. Connect the power pack as shown. Use approved wire nuts for electrical connections.
SCHEMATIC DIAGRAM
Hot
Line Voltage 120/277 VAC
Neutral
Voltage Selector
Black
White
Relay
Load
Red
Transformer
Control
Red (+24 VDC)
Black (Common)
Blue (Control)
Line Voltage
From Sensor Output
OUTSIDE
From Sensor Output
Line Voltage
SYSTEM DIAGRAM
Voltage Selector
Hot
Line Voltage 120/277VAC
Neutral
Load
BLK
White
RED
Ext. Override OFF
120V
277V
+24VDC Common Control Input
BLUE
Sensor
REDBLK