Veris 133 User Manual

133
Digital Multimeter
Instruction Manual
32
TABLE OF CONTENTS
page
1. Congratulations . . . . . . . . . . . . . . . . . .3
2. Product Description . . . . . . . . . . . . . .3
3. EC Declaration of Conformity . . . . . . . .4
B. SAFETY CONSIDERATIONS . . . . . . . . . . . .5
C. TECHNICAL DATA
1. Features and Benefits . . . . . . . . . . . . .6
2. Product Applications . . . . . . . . . . . . . .7
3. Specifications . . . . . . . . . . . . . . . . . . .8
D. MEASUREMENT TECHNIQUES
1. Controls and Functions . . . . . . . . . .10
2. Step by Step Procedures:
a) Measuring DC Volts . . . . . . .11
b) Measuring AC Volts . . . . . . .12
c) Measuring DC Amps . . . . . .13
d) Measuring AC Amps . . . . . .15
e) Measuring Resistance . . . . .17
f) Measuring Diodes . . . . . . . .18
g) Continuity Buzzer . . . . . . . .19
h) Data Hold . . . . . . . . . . . . . . 19
E. ACCESSORIES . . . . . . . . . . . . . . . . . . . . .20
F. MAINTENANCE . . . . . . . . . . . . . . . . . . . .21
G. TROUBLE SHOOTING GUIDE . . . . . . . . . .22
A. INTRODUCTION
1. Congratulations!!
Thank you for purchasing TPI brand products. The meter is easy to use and is built to last. It is backed by a 3 year limited warranty. Please remember to complete and return your product warranty registration card.
2. Product Description
The 133 is a hand held manual ranging DMM. It features extra large numerals on the LCD, and Data Hold for all functions and ranges. The 133 is an affordable choice offering measurements in all of the basic electrical functions.
The 133 comes complete with the following:
133 Instrument Rubber Boot (133NB does not include boot) Test Lead Set Instruction Manual Battery
54
B. SAFETY CONSIDERATIONS
WARNING: Please follow manufacturers test pro­cedures whenever possible. Do not attempt to measure unknown voltages or components until a complete understanding of the circuit is obtained.
GENERAL GUIDELINES AL
WAYS
• Test the 133 before using it to make sure it is operating properly.
• Inspect the test leads before using to make sure there are no breaks or shorts.
• Double check all connections before testing.
• Have someone check on you periodically if working alone.
• Have a complete understanding of circuit being measured.
• Disconnect power to circuit, then connect test leads to the 133, then to circuit being measured.
NEVER
• Attempt to measure unknown high voltages.
• Attempt to measure current with the meter in parallel to the circuit.
• Connect the test leads to a live circuit before setting up the instrument.
• Touch any exposed metal part of the test lead assembly.
3. EC Declaration of Conformity
This is to certify that model 133 conforms to the protection requirements of the council directive 89/336/EEC, in the approximation of laws of the member states relating to Electromagnetic compatibility and 73/23/EEC, The Low Voltage Directive by application of the following standards:
EN 50081-1 1992 Emissions Standard EN 50082-1 1992 Immunity Standard EN61010-1 1993 Safety Standard EN61010-2-031 1995 Safety Standard
To ensure conformity with these standards, this instrument must be operated in accordance with the instructions and specifications given in this manual.
CAUTION:
Even though this instrument complies with the immunity standards, the accuracy can be affect­ed by strong radio emissions not covered in the above standards. Sources such as hand held radio transceivers, radio and TV transmitters, vehicle radios and cellular phones generate electromagnetic radiation that could be induced into the test leads of this instrument. Care should be taken to avoid such situations or alternatively, check to make sure that the instru­ment is not being influenced by these emis­sions.
!
2. Product Applications
Perform the following tests and/or measurements with the TPI 133 and the appropriate function:
HVAC/R
FUNCTION DCmV • Thermocouples in furnaces or gas
applications.
ACA • Heat anticipator current in thermostats.
ACV • Line voltage.
ACV or DCV • Control circuit voltage.
DCµA • Flame safeguard control current.
OHMS • Heating element resistance (continuity).
OHMS • Compressor winding resistance.
OHMS • Contactor and relay coil resistance.
OHMS • Continuity of wiring.
DCmV • Temperature with optional temperature
adapter (A310).
ELECTRICAL
FUNCTION ACV • Measure line voltage.
OHMS • Continuity of circuit breakers.
DCV • Voltage of direct drive DC motors.
76
INTERNATIONAL SYMBOLS
CAUTION: RISK OF ELECTRIC SHOCK
AC (ALTERNATING CURRENT)
DC (DIRECT CURRENT)
REFER TO INSTRUCTION MANUAL
GROUND
FUSE
DOUBLE INSULATION
ON/OFF, PUSH BUTTON SWITCH
C. TECHNICAL DATA
1. Features and Benefits
Safety Meets CE and IEC 1010 requirements.
UL Listed to U.S. and Canadian Safety Standards.
Large LCD Easy to read at all angles and the
majority of lighting levels.
Rubber Boot Added protection when the instrument
is dropped. (133NB does not include boot.)
Multi-function Measure all electrical characteristics
with one meter.
!
Loading...