Verilink PRISM 3021 Installation Guide

TRANSPORT
®
3021 E1 NTU/DSU
Configuration Guide
45 -00112
1.0
1
®
TRANSPORT
ST ATUS
3021
E1 CSU/DSU
9
BV/CR/FE
TD
2
10
E
N
LOS/OOF
T
D
RD
3
11
T
AIS
E
RTS
4
125
REM ALM
DTR
13
LOOP
TST
TST
14
15
ERR
SUPV Port
LOCFAR
SUPV Port
Pin
Interface
1
8
SUP
V
6
7
8
1 Control Out 2 Signal Groun d 3 Data Out 4 Data In 5 Signal Groun d 6 Control In
Front Panel Description
Index Item Function
1 STATUS If neither LED is On, the 3021 is not powered. If only the green LED is On, the 3021 is powered and may be functioning normally. If only the red LED is On, there
2 TD This green LED is On during a mark condition on the high-speed transmit data line. 3 RD This green LED is On during a mark condition on the high-speed receive data line. 4 RTS This green LED is On when the request-to-send signal is active. 5 DTR This green LED is On when the data-terminal-ready signal is active. 6 FAR/LOC
Switch
7Activity
Indicators 8 SUPV Port The supervisory jack provides direct terminal access to control and monitor the 3021. 9 BV/CR/FE This LED is On when the unit detects bipolar violations, cyclic redundancy checking errors, or framing errors. 10 LOS/OOF This LED flashes when the unit detects a loss-of-signal condition or remains On during an out-of-frame condition. 11 AIS This LED is On when the network interface is receiving an alarm indication signal. 12 REM ALM This LED is On when the network interface is receiving a remote alarm indication. 13 LOOP This LED is On when the network interface is in a line loopback. 14 TST This LED is On when a BERT is in progress. 15 ERR This LED is On when BERT pattern errors are detected.
is a fault that exceeds alarm thresholds or another type of 3021 failure.
This switch is used for local testing and setting the SUPV port rate when downloading firmware for the Flash PROM. For testing, setting the switch to LOC performs a network LLB and setting the switch to FAR sends fiv e seconds of in-band loop code and then sends the BERT pattern selected in the user interface. The default pattern is QRSS.
These two small, recessed LEDs indicate supervisory/network manager port activity.
Network Interface
Service Types: CEPT/E1 Line Rate: 2.048 Mbps (±50 ppm) Framing: CAS or CCS Line Code: AMI or HDB3 Input Signal: 0 t o -2 2. 5 dB ALBO Line Connection: 75 Ω: BNC
120 Ω: DB-15, twinax, and RJ-48
Output Signal: Per G.703 with 75-Ω or
120-Ω option Surge Protection: 1000 volts High-Speed Data
Port Compatibility: ITU V.35 female
DB-25, female 34-pin
through adapter cable,
ITU X.21 fe m a l e
DB-15; EIA-530 DB-25 Rate: Synchronous, N×56, or
N×64 kbps (N = 1 to 31 ) Clocking: Internal or external Data Invert: Enabled or disabled
Specifications
Configuration
Configuration: Car d-edge switches
Terminal interface on the supervisory port, Tel net session using the 8100A SNMP Management System. Soft configura­tion is non-volatile.
Diagnostics
Performance: RFC1406 (with the 8100A) Status: Front panel LEDs for
network, t esting, and DTE
Network Loopbacks: Line, payload,
and proprietary E1-DTE Loopbacks: Line and proprietary DTE Loopbacks: Responds to V.54 in-band
loop codes and pe rf orms
bidirectional f ractional-
port loopback
Power
Power: -48 VDC, 150 mA, max;
7.2 W, (24.6 BTU, max)
Mechanical
Mounting: W all, vertical, horizontal
rack, TxPORT 1051 chassis, or standalone
Weight: 1 pound, nominal
Compliance
FCC Compliance: Part 15, Class A, Subpart B US Safety: UL 1950, 3rd Ed. (Pending) Canadian Safety: CSA: C22.2 No. 950-95
(Pending) G.703: Signal Waveform G.704: Framing G.732: Multiframing G.823: Jitter G.831: Framing Requirement
Environmental
Operating Temp: 0° to 50°C(32° to 122°F) Storage T emp: -20° to 85°C(-4° to 185°F) Relative Humidity: 95% max., non-condensing
TOP-E
DGE VIEW OF THE
Switch
12345
Switch S3
S4
PRISM 3021
81234567
Switch S2
81234567
Switch S1
Switch SW1
3
2
4
1
5
0
6
9
7
81234567
8
B
OTTOM-EDGE VIEW OF THE
E1-DTE Option Switch S1
18765432
PRISM 3021
Switch S1
S1-1:
Sets network framing. Down: CAS
S1-2:
Sets CRC4. Down: Enable d
S1-3:
Selects network line code. Down: HDB3
S1-4
S1-5:
and
source.
Timing Source S1-4 S1-5
Network Internal Down Up E1 DTE Up Down DTE or External Up Up
S1-6:
Selects keep alive framed and unframed ones. Down: Keep alive unframed ones Up: Keep alive framed ones
S1-7:
Selects normal or inverted data
Up: CCS
Up: Disabled
Up: AMI
Select the unit’s timing
Down Down
Switch S2 sets the unit address. When using the
3021 with an 8100A Site Controller, each ele­ment in a group must have a unique unit address. As many as 50 units (with addresses from 1 to 50) can exist in a group. If the unit is not connected to a site controller, the NMS unit address should be left at the factory default set­ting of 1 positions are Down.
Switch S2 has eight positions used to create an 8-bit binary code for an address i n the range of 1 to 50. Switch position S2 -1 is the lea st sign if­icant bit (LSB) and S2 -8 is the most significant bit (MSB). If a switc h is down, its value is 0. If up, its value is that of the upper location. The values ar e additive. For exa mple, to set a unit address to 5, position S2 -3 (binary value is 4) and position S2 - 1 (bi nary value is 1) would be set Up for a unit address of 5 (4 + 1). All other positions would be set
Switch S2
where Position 1 is Up and all other
.
Down
LSB MSB
binary values
1 2 4 8 16 32 64 128
mode.
Down: Normal
S1-8:
Used for programming the Flash memory. Down: Disabled
Switch SW1
SW1:
Sets the national bit .
National Bit Switch Position
None 0 SA4 SA5 2 SA6 3 SA7 4 SA8 5 None 6-9
Factory default settings are underlined.
Up: Inverted
Up: Enabled
1
00000000
Down Up
TRANSPORT
127 Jetplex Circle
Madison, Alabama 35748
Sales and Marketing
800-926-0085 205-772-3770
info@txport.com
Returns and RMA
800-926-0085, ext. 2227
Technical Support
800-258-2755 205-772-3770
7654321 8
®
For 3021 applications, read E1 in place of T1 on the rear of the 1051 chas sis.
Switch S3
S3-1
S3-2:
and
port rate. Configure the port
S3-3
S3-5
S3-7:
S3-8:
Set the NMS
for 8 bits, no parity, and 1 stop bit.
NMS
Port Rate
19200 bps 9600 bps Down Up 2400 bps Up Down 1200 bps Up Up
S3-4:
and
S3-1 S3-2
Down Down
Set the SUPV port rate. Configure the port for 8 bits, no parity, and 1 stop bit.
SUPV
Port Rate
38400 bps 19200 bps Down Up 9600 bps Up Down 2400 bps Up Up
S3-6:
and
Boot
Mode
Switches RAM Down Up ROM Up Down Reserved
for future expansion.
S3-3 S3-4
Down Down
Set the boot mode.
S3-5 S3-6
Down Down
Up Up
Selects the D TE rate multiplier.
×
Down: N
64 Up: N×56 Selects the channel assignment mode. Down: Contiguous Up: Alternating
Switch S4
S4-1
DTE Rate
N=31 N=3011680 1920 Up Down Down Down Down N=29 N=28 N=27 N=26 N=25 N=24 N=23 N=22 N=21 N=20 N=19 N=18 N=17 N=16 N=15 840 960 Down Down Down Down Up N=14 784 896 Up Down Down Down Up N=13 728 832 Down Up Down Down Up N=12 672 768 Up Up Down Down Up N=11 616 704 Down Down Up Down Up N=10 560 640 Up Down Up Down Up N=9 504 576 Down Up Up Down Up N=8 448 512 Up Up Up Down Up N=7 392 448 Down Down Down Up Up N=6 336 384 Up Down Down Up Up N=5 280 320 Down Up Down Up Up N=4 224 256 Up Up Down Up Up N=3 168 192 Down Down Up Up Up N=2 112 128 Up Down Up Up Up N=1 56 64DownUpUpUpUp
1
This selection is not valid if the Channel Assignment is set to Alternating.
2
This selection is not valid for CAS mode.
S4-5:
through
(kbps)
1,2
1 1 1 1 1 1 1 1 1 1 1 1 1 1
Set the DTE rate.
N×56
N×64
S4-1 S4-2 S4-3 S4-4 S4-5
(kbps)
1736 1984 Down Down Down Down Down
1624 1856 Down Up Down Down Down 1568 1792 Up Up Down Down Down 1512 1728 Down Down Up Down Down 1456 1664 Up Down Up Down Down 1400 1600 Down Up Up Down Down 1344 1536 Up Up Up Down Down 1288 1472 Down Down Down Up Down 1232 1408 Up Down Down Up Down 1176 1344 Down Up Down Up Down 1120 1280 Up Up Down Up Down 1064 1216 Down Down Up Up Down 1008 1152 Up Down Up Up Down
952 1088 Down Up Up Up Down 896 1024 Up Up Up Up Down
E1-DTE Option Switch S1
S1-1:
Sets CRC4. Down: Enabled
S1-2:
Selects the E1-DTE line code. Down: HBD3
S1-8:
Selects the E1-DTE line termination. Down: 75 ohm
Up: Disabled
Up: AMI
Up: 120 ohm
( B ) NMS
IN
12 8 7 6 5 4 3 21011 1 9
( B ) NMS OUT
TB1 TB2
Rear Panel of the TxPORT 1051-2 Chassis
T1 DTE
HIGH SPEED DTE
T1 NET
TB1 TB2
( A ) NMS
IN
( A ) NMS OUT
ENET
Rear Panel Connections
E1 NET
Pin
123456789101112
123456789101112
(labeled
T1 NET)
1 Data In Not Used Not Used Ntwk In 48-V Return Tip Output 2 Data In Signal Gnd Signal Gnd Ntwk In Signal Gnd Ring Output 3 Not Used Data Out Data Out Ntwk Out -48 VDC Not Used 4 Data Out Data In Not Used Ntwk Out Frame Gnd Tip Input 5 Data Out Signal Gnd Signal Gnd Station Clk Alm Contact Ring Input 6 Not Used Not Used Not Used Station Clk Common Not Used 7 Not Used N/A N/A N/A N/A Chassis Gnd 8 Not Used N/A N/A N/A N/A Chassis Gnd
NMS IN
NMS OUT
*
TB1
Network/
Clock
TB2
Alarm/
Power
E1 DTE
(labeled T1
DTE)