This installation guide contains the procedure to configure and install an Ethernet or Token Ring card into a 3100 series, 4100
series, or an 8100A unit.
Step 1:
Step 2:
[Ethernet card only] Configure the ethernet card by setting the jumper (J1) and the dual in-line package (DIP)
switches (S1). Refer to bottom figure for location identification. Refer to the following table for setting positions.
Unit J1 S1-1 (A16) S1-2 (A17) S1-3 (A18) S1-4 (A19)
3100 Series 1-2 Off Off On On
4100 Series 2-3 Off Off On On
8100A 2-3 Off On Off On
S1 settings have four different interpretations:
On = Closed = Up = 0
Off = Open = Down = 1
Disconnect power to the unit. Flip the unit and place it on a flat surface. Remove the four screws with a Phillips
head screwdriver. Then , flip the unit b ack to the upright po sition. G ently remove the top cover to expose the main
circuit board.
PRISM 3101
TEST LOOP
TEST
LOOP NET ALARM POWER
TRANSPORT
screws
TRANSPORT
LOOP NET ALARM POWER
TEST
TEST LOOP
screws
PRISM 3101
PRISM 3101
TEST LOOP
TEST
LOOP NET ALARM POWER
TRANSPORT
Step 3:
Insert the plastic stand-offs on the card into the main circuit board. as shown in the figure below.
S1
J1
A
C
C
S1, S2 and S3
switches
D
D
A
Step 4:
Once the board is firmly connected, place the cover back on the unit, flip the unit, and reinsert the four screws.
B
B