VENTS AXIAL DECORATIVE FANS User Manual

AXIAL DECORATIVE FANS
VENTS LD
Series
Axial decorative fans
for exhaust ventilation with air
capacity up to 310 m3/h
Application
Continuous or periodic exhaust ventilation
of bathroom, showers, kitchens and other utility spaces.
Ventilation shaft mounting or duct connec-
tion.
Low to medium air ow motion for short dis-
tances at low air resistance.
Compatible with Ø 100, 125 and 150 mm air
ducts.
LDA
LDA gold
LDA chrome
LD alulak
Design
Modern design and aesthetic look.
The casing and the impeller are made of high-
quality durable ABS plastic, UV resistant.
Various decorative plates for the front panel of
the natural aluminum.
The intellectual impeller design makes the fan
eciency high and the service life long.
Protection rating IP34.
Motor
Reliable and low-watt electric motor.
Designed for continuous operation and
requires no maintenance.
Equipped with overheating protection.
Modifications and Options
LDA – the fan with a ground alumunium front
panel.
LDA gold – the fan with a gold-tinted aluminium front panel.
LDA chrome – the fan with a mirror nish aluminium front panel.
LD alumat – the fan with a front panel painted silver (matt).
LD alulak – the fan with a front panel painted silver (gloss).
LD1 – shortened branch pipe model.
LD K – fan is equipped with a backdraft
damper for back ow preventing.
LD L – the motor is equipped with ball bearings for long service life (appr. 40
any angle. The bearings are maintenance-free and contain enough grease for the entire operating period.
sensor with the threshold value from 60 to 90%.
thousand hours) and fan mounting at
LD turbo – high-powered motor.
LD 12 – modication with low-voltage
motor. 12 V AC power supply.
LDT – equipped with a regulated timer with the operating time from 2 to 30 minutes.
LDTH – equipped with a timer with the operating time from 2 to 30 minutes and a humidity
LDV – equipped with a pull cord switch.
LDVT – equipped with a pull
cord switch and a regulated
adjustable from 2 to 30 minutes.
timer with the operating time adjustable from 2 to 30 minutes and a humidity sensor with the operating threshold range from 60 to 90%.
timer with the operating time
LDVTH – equipped with a pull cord switch, regulated
Control
Manual:
The fan is controlled by a room light switch. It
is not included in the delivery set.
The fan is controlled by the built-in pull cord
switch V. Not applied in case of ceiling mounting.
Speed control is possible through a thyristor
speed controller (see Electrical Accessories). Several fans may be connected to the same controller. Speed controllers can not be connected to the fans with T, TH, TP, VT, VTH modications.
Automatic:
By the BU-1-60 electronic control unit (see
Electrical Accessories). The control unit is supplied separately.
By the T timer (the built-in turn-o delay timer
enables the fan operation within 2 to 30 minutes after the fan switching o).
By the humidity sensor and the TH timer (ifthe
humidity level in the room exceeds the sensor threshold adjustable value within 60-90% the fan switches automatically on and operates until the humidity level drops to the standard level, after that the fan continues operating within the time period according to the timer setting, then shuts down).
Mounting features
The fan is mounted directly into the ventilation
shaft.
In case of remote location of the ventilation
shaft exible air ducts may be used. The air duct is connected to the fan exhaust ange through a clamp.
Fixed to the wall by means of screws.
Suitable for ceiling mounting.
To connect a fan with a 12 V low voltage motor
to 220 V/50 Hz power mains, it is necessary to purchase a step-down transformer (e.g. the TRF 220/12-25 transformer).
114
LD alumat
Air ducts
Accessories
Grilles and hoods
VENTS. Domestic ventilation. Catalogue 6 | 012019
Backdraft
damper
Speed controllers
Clamps
Aerodynamic characteristics
Pressure, ΔP [Pa]
Air flow [m3/h]
Air flow [m3/h]
Air flow [m3/h]
VENTS100 LD VENTS100 LD turbo VENTS100 LD (127-220 V/60 Hz) VENTS100 LD 12
VENTS125 LD VENTS125 LD turbo VENTS125 LD (127-220 V/60 Hz)
Pressure, ΔP [Pa]
VENTS125 LD 12
Pressure, ΔP [Pa]
VENTS150 LD VENTS150 LD turbo VENTS150 LD (127-220 V/60 Hz) VENTS150 LD 12
Technical data
Model
Frequency
[Hz]
Voltage [V]
Power
Consumption
[W]
VENTS 100 LD 50/60 220-240 14 0.085 2300 88 33 0.60 VENTS 100 LD turbo 50/60 220-240 16 0.1 2300 115 36 0.68
VENTS 100 LD (127-220 V/60 Hz)
60
127 10 0.115
220 9 0.054 VENTS 100 LD 12 50/60 12 14 1.5 2200 77 32 0.59 VENTS 125 LD 50/60 220-240 16 0.1 2400 167 34 0.74 VENTS 125 LD turbo 50/60 220-240 24 0.105 2400 209 36 0.84
VENTS 125 LD (127-220 V/60 Hz)
60
127 16 0.119
220 15 0.102 VENTS 125 LD 12 50/60 12 16 1.7 2300 149 33 0.72 VENTS 150 LD 50 VENTS 150 LD (220-240 V/60 Hz)
60
220-240 24 0.13 2400 265 37 0.96
VENTS 150 LD turbo 50 VENTS 150 LD turbo
(220-240 V/60 Hz)
VENTS 150 LD (127-220 V/60 Hz)
60
60
220-240 29 0.13 2400 310 39 1.10
127 25 0.175
220 25 0.388
Current
[A]
R.p.m.
Maximum air
ow [m3/h]
Sound Pressure
Level at 3m [dBA]
Weight
[kg]
2500 82 33 0.60
2400 172 35 0.74
2350 240 37 0.96
VENTS 150 LD 12 50 12 29 2 2300 236 36 0.92
Mounting example
Overall dimensions
Model
Ø D B H L L1
Dimensions [mm]
VENTS 100 LD 100 152 120 126 30
VENTS 100 LD1 100 152 120 111 30
VENTS 125 LD 125 177 140 135 34
VENTS 125 LD1 125 177 140 116 34
VENTS 150 LD 150 206 165 154 36
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
VENTS. Domestic ventilation. Catalogue 6 | 012019
115
Loading...