Vent-A-Hood EPH18242SS, EPTH18460SS, PDH14236SS, SEPH18236SS, SEPTH18348SS Installation Manual

...
U
L
CUS
R
Read and Save These Instructions
All Hoods Must Be Installed By A Qualied Installer
EUROLINE/EUROLINE PRO
WALL MOUNT HOOD
Read All Instructions Thoroughly Before Beginning Installation
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualied person(s)
in accordance with all applicable codes and standards, including re­rated construction. Switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally
during installation.
B. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
C. Ducted fans must always be vented to the outdoors.
D. Sufcient air is needed for proper combustion and exhausting of gases
through the ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and local code authorities.
E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to
a maximum of 15 CFM per 100 square feet of occupiable space, unless a back drafting test is performed or make-up air is provided. Consult a local HVAC engineer for make-up air evaluation.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK
Page 1L112 0611A
Ducting Do’s and Don’ts
NEVER restrict the duct size. The single blower unit (B100) requires 6” round duct or equivalent (28 square inches), and the dual blower unit (B200) requires 8” round duct or equivalent (50
square inches). When combining ducts together, the square inch area must reect the total
square inch area of the ducts being combined. Using Vent-A-Hood transitions (back page) will
ensure proper efciency.
Blower Duct Size Sq. Inch Area Vent-A-Hood Transition
Single (B100) 6” round or equivalent 28” N/A Dual (B200) 8” round or equivalent 50” N/A Single and Dual (B100 & B200) 10” round or equivalent 79” VP562 (Included) Two Dual (Two B200s) 12” round or equivalent 113” VP563 (Included)
Do not use exible or corrugated duct. This type of duct will restrict airow and reduce performance. Only use smooth, galvanized, metal duct. Observe local codes regarding special
duct requirements and placement of duct against combustibles. Make the duct run as short and as straight as possible with as few turns as possible. Avoid sharp-angled turns. Instead, use smooth, gradual turns such as adjustable elbows or 45 degree angled turns. For duct runs
over 20 feet, increase the duct diameter by one inch for every ten feet of duct. A 90 degree
elbow is equal to 5 feet of duct. Using Vent-A-Hood roof jacks or wall louvers (back page) will
ensure proper efciency. Airow must not be restricted at the end of the duct run. Do not use
screen wire or spring-loaded doors on wall louvers or roof jacks. Do not terminate venting into
an attic or chimney. Where possible, seal joints with duct tape. The hood must be ducted to the
outdoors without restrictions.
YES
NO
Smooth Duct
Flexible Duct
Smooth Gradual Turn
Sharp Angled Turns
Page 2L112 0611A
Installation Details
1) Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard hoods only. Custom hoods may require additional specication consideration.
2) When installing a 14” tall Euroline wall mount range hood, it is recommended that the bottom edge of the hood be located no more than 24” above the cooking surface. When installing an 18” tall Euroline Pro wall mount range hood, it is recommended that the bottom edge of the hood be located no more than 30” above the cooking surface. Exceeding the recommended maximum mounting height may compromise performance.
14” Tall Hoods 18” Tall HoodsShown with duct cover installed (sold separately).
3) IF THE HOOD IS TO BE “BACK VENTED”, PROCEED DIRECTLY TO STEP 4.
Install the duct from the outside of the home down to the location of the exhaust outlet on the top of the hood allowing
room for the transition (if applicable). If a transition is used, install duct down to the location of the transition outlet plus 1”. This will allow the transition to engage 1” inside of duct. Consult the connection diagrams (on next two pages) for further details on exhaust outlet placement.
Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is provided on the back
page of this instruction sheet.
Transition heights are as follows:
Single Blower (B100): 6” round duct will connect directly to the top of the hood.
Dual Blower (B200): 8” round duct will connect directly to the top of the hood.
Single and Dual Blower (B100 & B200): 10” round combination transition (VP562, included) extends 8 1/2” above
the top of the hood.
Two Dual Blowers (Two B200s): 12” round combination transition (VP563, included) extends 7 1/2” above
the top of the hood.
4) Remove the hood from its packaging and place the back of the hood on the oor or countertop in front of the wall
where it will hang.