Venmar HEPA 3.2, THH 1.0 Installation Instructions And User Manual

INSTALLATION INSTRUCTIONS
AND USER MANUAL
RESIDENTIAL USE ONLY
INSTALLER: LEAVE THIS MANUAL WITH CONSUMER. HOMEOWNER: USE AND CARE INFORMATION
ON PAGES
22, 25, 28, 29 and 30.
READ AND SAVE THESE INSTRUCTIONS
MODELS
HEPA 3.2* and THH 1.0*
*Patents pending
NOTE: HEPA 3.2 model available in Canada only.
For United States, use Venmar HEPA 1000 model.
VB0049
VB0058
ABOUT THIS MANUAL
First, we want to congratulate you on your purchase of this excellent unit which will allow you and your family to enjoy clean and healthy air throughout your home for years to come! The illustrations in this publication are typical ones. Some details of your unit may be slightly different than the ones shown.
Please take note that this manual uses the following symbols to emphasize particular information:
NOTE: Indicates supplementary information needed to fully complete an instruction.
We welcome any suggestions you may have concerning this manual and/or the unit, and we would appreciate hearing your comments on ways to better serve you. Please contact us at the address listed in the warranty text, at the end of this manual.
WARNING
Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death.
CAUTION
Denotes an instruction which, if not followed, may severely damage the unit and/or its components.
- 2 -
ABOUT THESE UNITS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING:
1. This unit is intented for residential installation only.
2. Installation must be done in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
3. This unit is not designed to provide combustion and/or dilution air for fuel-burning appliances.
4. Do not install in a cooking area or connect directly to an appliance.
5. Before replacing filters, servicing or cleaning unit, disconnect the power cord from electrical outlet.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.
7. Do not use this unit with any solid-state speed control device other than wall controls #04862 or #05439 (for HEPA 3.2 unit) and #04391 or #05536 (for THH 1.0 unit) (all control devices sold separately).
8. This unit must be grounded. The power supply cord has a 3-prong grounding plug for your personal safety. It must be plugged into a mating 3-prong grounding receptacle, grounded in accordance with the national electrical code and local codes and ordinances. Do not remove the ground prong. Do not use an extension cord.
9. This unit must be installed in a weatherized location out of direct sunlight and protected from the elements.
10. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in this document.
11. For general filtration and ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors.
CAUTION
1. Intended for residential installation only in accordance with the requirements of NFPA 90B.
2. Do not run any air ducts directly above or closer than 2 ft (0.61 m) to any furnace or its supply plenum, boiler, or other heat producing appliance.
2.1 For HEPA 3.2 unit only, if a duct has to be connected to the furnace return plenum, it must be connected
not closer than 2 ft (0.61 m) from this plenum connection to the furnace.
2.2 For
THH 1.0 unit only, if a duct has to be connected to the furnace return plenum, it must be connected
not closer than 9’10” (3 m) from this plenum connection to the furnace.
3. The ductwork is intended to be installed in compliance with all local and national codes that are applicable.
4. To avoid prematurate clogged filters, turn OFF the unit during construction or renovation.
5. Please read the unit specification label on the product for further information and requirements.
!
!
1. TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.1 Performance Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.4 Mounting and Servicing Consideration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
2. HEPA 3.2 UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.1 Inspect the Content of the Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.2 Locating and Mounting the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.3 Mount the Ports on the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.4 Mount the Nameplate on the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.5 How to Hang the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8
2.6 Planning of the Ductwork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
2.7 Calculating the Duct Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
2.8 Installing Ductwork and Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
3. THH 1.0 UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
3.1 Inspect the Content of the Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
3.2 Locating and Mounting the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
3.3 Mount the Ports on the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
3.4 Mount the Nameplate on the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
3.5 How to Hang the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-14
3.6 Planning of the Ductwork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
3.7 Calculating the Duct Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
3.8 Installing Ductwork and Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-17
3.9 Installing Insulated Flexible Duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18-19
3.10 Installing Dual Exterior Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21
3.11 Connecting the Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4. CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
4.1 Main Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.2 Optional Wall Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.4 Installation of the Optional Wall Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-24
4.5 Operating the #04862 or #05439 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.6 Operating the #04391 or #05536 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5. WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
5.1 HEPA 3.2 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
5.2 THH 1.0 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
6. BALANCING PROCEDURE (THH 1.0 ONLY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
6.1 What You Need to Balance the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
6.2 Preliminary Stages to Balance the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
6.3 Installation of Flow Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
6.4 Balancing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
7. MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
7.1 Semi-Annual Maintenance (Essential) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28-29
7.2 Annual Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
7.3 Master Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
8. PARTS ORDERING CHART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
9. T
ROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
10. WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
TABLE OF CONTENTS
- 3 -
EXT. STATIC NET SUPPLY GROSS AIR FLOW
PRESSURE AIR FLOW SUPPLY EXHAUST
1. TECHNICAL DATA
HEP
A 3.2 F
IL
TRATION
AIRFLO
W
THH 1.0 VENTILATION PERFORMANCE
High speed
(Boost mode)
Low speed
(Normal mode)
Airflow (Cubic Feet per Minute)
External static Pressure
(inch of water)
External static Pressure (inch of water)
0 20 40 60 80 100 120
0.00
0.20
0.40
0.60
0.80
1.00
1.20
Gross Airflow (Cubic Feet per Minute)
Low Speed
Supply (cfm)
Exhaust (cfm)
1.1 PERFORMANCE CHARTS
Model HEPA 3.2 THH 1.0 Weight 34 lbs (15.4 kg) 41.2 lbs (18.7 kg)
Performance
180 cfm low speed, 50 cfm low speed,
320 cfm high speed 90 cfm high speed Oval Ports fit two 8” round ducts fit four 5” or 6” round ducts Installation: Suspension 4 Chains, springs and hooks (included with the unit) Electrical Supply 120 Volts AC, 60 Hz Power Consumption (“Boost”) 170 Watts 192 Watts Power Consumption (“Normal”) 105 Watts 110 Watts
1.2 SPECIFICATIONS
- 4 -
NOTE : All specifications are subjected to change without notice.
High Speed
Supply (cfm)
Exhaust (cfm)
Pa
50 100 150
in.w.g.
.2 .4 .6
l/s 23 21 19
cfm
48 45 40
m 3/h
82 76 68
l/s 24 23 20
cfm
51 48 43
m 3/h
87 82 73
l/s 26 23 19
cfm
54 49 41
m 3/h
92 83
70
HIGH SPEED
LOW SPEED
EXT STATIC NET SUPPLY GROSS AIR FLOW PRESSURE AIR FLOW SUPPLY EXHAUST
Pa
50 100 150 200 250
in.w.g
.2 .4 .6 .8
1.00
l/s 47 44 41 37 34
cfm 100
93 86 79 73
m 3/h
170 158 146 134 124
l/s 50 46 42 39 36
cfm
105
98 90 83 76
m 3/h
178 165 155 141 129
l/s 50 46 43 38 33
cfm 106
99 91 80 71
m 3/h
180 167 155 136 121
THH 1.0 ENERGY PERFORMANCE
SUPPLY POWER SENSIBLE APPARENT
TEMPERATURE NET AIR FLOW CONSUMED RECOVERY SENSIBLE
WATTS EFFICIENCY
EFFECTIVENESS
116 147 189 114
63 59 57 58
85 75 75 95
0 0 0
-25
+35 +35
+32 +32 +32
-13
+95 +95
l/s
24 35 44 16
–– ––
cfm
52 74 94 35
–– ––
m
3
/h
87 126 158
59
––
––
COOLING
HEATING
TOTAL RECOVERY EFFICIENCY
Not tested
1.20
1.00
0.80
0.60
0.40
0.20
0.00
100 125 150 175 200 225 250 275 300 325
VG0064
- 5 -
1. TECHNICAL DATA (CONT’D)
1.3 DIMENSIONS
HEPA 3.2 THH 1.0
FRONT VIEW TOP VIEW FRONT VIEW TOP VIEW
1.4 MOUNTING AND SERVICING CONSIDERATIONS
The two following pictures are showing the minimum clearance needed to open the door completely.
22.5” 15.75”
(572 mm) (400 mm)
VD0117
VD0116
22”
(559 mm)
NOTES: 1. A minimum of 8” (203 mm) clearance from any obstruction on top of the unit is required for the ductwork radius turn.
2. A grounded three-prong electrical outlet has to be available within 3 feet from the unit.
8”
(203 mm)
22.9'' (581 mm)
VK0047
29''
(737 mm)
17.8''
(452 mm)
22.9'' (581 mm)
VK0049
30.2''
(767 mm)
17.8''
(452 mm)
2. HEPA 3.2 UNIT INSTALLATION
INSTALLATION TYPE SHOWN:CENTRAL DRAW POINT
SEE SECTION 2.8.2
STAND ALONE INSTALLATION
SEE SECTION 2.8.1
RETURN-RETURN INSTALLATION
SEE SECTION 2.8.3
HOW TO HANG THE UNIT
SEE SECTION 2.5
SECTION 4: CONTROL
DUCT SIZE,
I
NSTALLING DUCTWORK AND
REGISTERS
SEE SECTIONS 2.7 AND 2.8
VD0129
VC0054
- 6 -
VI0013
VH0037
VH0047
VH0038
2
.1 INSPECT THE CONTENT OF THE BOX
• Inspect the exterior of the unit for shipping damage. Ensure there is no damage to the door, door latches, main switch, etc.
• Inspect the interior of the unit for damage. Ensure the blower assembly, insulation, prefilter, HEPA filter, etc. are all intact.
• If the unit was damaged during shipping, contact your local distributor.
2.2 LOCATING AND MOUNTING THE UNIT
Choose an appropriate location for the unit.
• Within an area of the house where the ambient temperature is between 10°C (50°F) and 30°C (86°F) (basement, furnace room, closet, etc.).
• So as to provide easy access to the interior of the unit, for filter maintenance.
• Away from hot chimneys and other fire hazards.
2.3 MOUNT THE PORTS ON THE UNIT
Mount the 8” (HEPA 3.2 unit) oval ports on the top of the unit using the screws provided in the hardware box (4 screws #8 x 3/4” long per port).
NOTE: If an optional wall control has to be installed, do not install the front oval port (1) at this time.
2.4 MOUNT THE NAMEPLATE ON THE UNIT
Select your company nameplate (Venmar or vänEE) and snap it on the unit door. Discard the other nameplate.
2.5 HOW TO HANG THE UNIT
Use the 4 chains and springs in the hardware pack provided with the unit. According to your needs, you can install the unit either in vertical or horizontal position.
CAUTION
Remove the cardboard strip inside the unit.
WARNING
To avoid risk of suffocation, discard the plastic bag wrapping the unit.
!
1
2. HEPA 3.2 UNIT INSTALLATION (CONT’D)
VO0049
VERTICAL POSITION
HORIZONTAL POSITION (LEFT SIDE)HORIZONTAL POSITION (RIGHT SIDE)
- 7 -
VO0045
VD0129
VD0130
VD0131
2. HEPA 3.2 UNIT INSTALLATION (CONT’D)
2.5 HOW TO HANG THE UNIT (CONTD)
Turn the switch knob to OFF position in order to unlock the door. Unlatch the door and open it.
NOTE: If preferred, the door can be removed. First, remove the stopper (A) located on the
right side of the door hinge, then, slide the door out of its hinge.
• Using a screwdriver, remove the 2 retaining screws of the front plate and carefully remove the front plate from the unit.
Insert the 4 hooks in the square holes and fix them to the unit using 4 screws #8 - 32 x 3/4”.
NOTE: If an optional wall controll has to be installed, go to Section 4.0 on pages 20 to 22.
If not, continue the installation.
Reinstall the front plate, the door and the door stopper.
Hang the unit to the floor joist, using 4 #8 x 1 1/2” screws, 4 chains and 4 spings.
See illustration beside.
VO0019
VO0020
- 8 -
VD0170
A
VD0132
2. HEPA 3.2 UNIT INSTALLATION (CONT’D)
2.6 PLANNING OF THE DUCTWORK
• Follow the instructions in Section 2.7 below to determine the appropriate duct diameters for your system. Do not use branch lines smaller than 6”ø (152 mm) diameter.
• Do not use wall cavities as ducts.
• Keep it simple. Plan for a minimum of bends and joints.
• Do not ventilate crawl spaces or cold rooms.
• If the house has two floors or more, be sure to plan for at least one exhaust register at the highest lived-in level of the house.
2.7 CALCULATING THE DUCT SIZE
Use the table below to ensure that the ducts you intend to install will be carrying air flows around the recommended values. Avoid installing ducts that will have to carry air flows near the maximum values and never install a duct if its airflow exceed the maximum value.
NOTE: Examples 2.7.1 and 2.7.2 use imperial measures. The same calculation applies to metric measures.
2.7.1 EXAMPLE OF CALCULATION:
Problem: My installation requires two exhaust registers (one for the kitchen, one for the living room). I will connect these registers to
a main duct which will connect to the unit (high speed performance value of 320 cfm). What size of duct should I use for the main exhaust duct and for the two end branches leading to the registers? (See illustration below.)
Solution: Simplified method.
(For a more detailed method of calculating duct size refer to the
ASHRAE or HRAI HANDBOOK). Main duct:
Table on page 8 indicates a 8” Ø: recommended air flow: 260 cfm; maximum air flow: 380 cfm.The high speed air flow of 320 cfm is close enough to the recommended value (260) and far enough of the maximum value (380). Therefore a 8”Ø duct or larger is an appropriate choice for the main e
xhaust duct.
End br
anches: Each end branch will have to transport an air flow of 160 cfm (320 divided by 2). Table on page 8 indicates a 6ӯ: recommended air flow: 120 cfm; maximum air flow: 180 cfm. The high speed air flow of 160 cfm is close enough to the recommended value (120) and far enough of the maximum value (180). Therefore a 6ӯ duct or larger is an appropriate choice for the 2 end br
anches.
2.7.2 EXAMPLE OF A DESIGN FOR A FULLY DUCTED SYSTEM FOR A UNIT HAVING A HIGH SPEED PERFORMANCE OF 320 CFM.
CAUTION
Do not attempt to recover the exhaust air from a dryer or a range hood. This would cause clogging of the filters.
6”(152 mm) 120 cfm 57 l/s 204 m3/h 180 cfm 85 l/s 306 m3/h 7”(178 mm) 185 cfm 87 l/s 314 m3/h 270 cfm 127 l/s 459 m3/h 8”(203 mm) 260 cfm 123 l/s 442 m3/h 380 cfm 179 l/s 645 m3/h
Duct Recommended Maximum
Diameter Air Flow Air Flow
- 9 -
Main branch 8”ø 320 cfm
End branches
6”ø 160 cfm
8”ø 320 cfm
8”ø 320 cfm
6”ø 160 cfm
6”ø 160 cfm
6”ø 160 cfm
6”ø 160 cfm
VI0012
VI0013
2.8 INSTALLING DUCTWORK AND REGISTERS
2.8.1 STAND ALONE SYSTEM
Stale air exhaust ductwork
• Install the stale air exhaust registers in the areas where the contaminants are produced: kitchen, living room, etc. Position the register as f
ar from the stairway as possible and in such a way that the air circulates in all the lived-in spaces in the house.
NOTE: Never install a stale air exhaust register in a bathroom.
• If a register is installed in the kitchen, it must be located at least 4 feet (1.2 m) from the range.
• Install the registers 6 to 12 inches (152 to 305 mm) from the ceiling on an interior wall OR install it in the ceiling.
• Use the provided red sticker dots to identify the duct.
Filtered air distribution ductwork
• Install the filtered air distribution registers in the lowest level to ensure the greatest possible air circulation. Keep in mind that the filtered air registers must be located as far as possible from the stale air registers.
• Install the register in the ceiling OR 6 to 12 inches (152 to 305 mm) from the ceiling on an interior wall. The duct length should be at least 15’ (4.6 m). (The filtered air will then flow through the room and mix with room air, ensuring a continuous recirculating airflow.)
• Use the provided blue sticker dots to identify the duct.
How to connect the flexible duct to the unit ports
• Each port is identified on top of the unit (see illustrations below). Attach the filtered air to building duct to its corresponding port, using tie wrap (1). Then, attach the exhaust air from building duct to the other port (2).
NOTE: Use a 8’’ insulated duct if the duct will have to go through extreme temperature (e.g.: in northern area, not heated attic in
winter or attic not cooled in southern area). Also. if you plan to stop the unit for more than 12 hours, we recommend to cover the duct with R12 insulation.
2. HEPA 3.2 UNIT INSTALLATION (CONT’D)
WARNING
Never install a stale air exhaust register in a closed room where a combustion device operates, such as a gas furnace, a gas water heater or a fireplace.
!
- 10 -
12
VO0047
VO0048
2. HEPA 3.2 UNIT INSTALLATION (CONT’D)
2.8 INSTALLING DUCTWORK AND REGISTERS
2.8.2 CENTRAL DRAW POINT
Filtered air distribution ductwork (Return side connection)
• Locate the opening for the filtered air ductwork on the furnace / air handler return duct at a minimum linear distance of 2’ (0.61 m) upstream (return side: A+B+C).
• Attach this duct to the
FRESH AIR TO BUILDING
port (see icon on the top of the unit), using tie wrap
and duct tape. Use the provided blue sticker dots to identify the duct
Stale air exhaust ductwork
Same as for Stand Alone System, described in point 2.8.1.
2.8.3 RETURN-RETURN
Filtered air distribution ductwork (Return side connection)
Same as for Central Draw Point, described in point 2.8.2.
Stale air exhaust ductwork (Return side connection)
• Locate the take-off duct opening at least 3’ (0.9m) from the filtered air ductwork connection. Proceed as for the filtered air ductwork, but instead of using the blue dot sticker to identify the duct, use the red dot.
• Attach this duct to the
EXHAUST AIR FROM BUILDING
port (see icon on the top of the unit) using tie wrap
and duct tape.
WARNING
When performing duct connections, always use approved tools and materials. Respect all corresponding laws and/or safety regulations. Please refer to your local building code.
!
Minimum 3’
(0.9 m) from
filtered air
ductwork
connection
WARNING
When performing duct connections, always use approved tools and materials. Respect all corresponding laws and/or safety regulations. Please refer to your local building code.
!
- 11 -
A
B
C
VD0114
VO0047
VO0048
3. THH 1.0 UNIT INSTALLATION
INSTALLATION TYPE SHOWN:CENTRAL DRAW POINT
SEE SECTION 3.8.2
STAND ALONE INSTALLATION
SEE SECTION 3.8.1
RETURN-RETURN INSTALLATION
SEE SECTION 3.8.3
HOW TO HANG THE UNIT
SEE SECTION 3.5
CONNECTING THE DRAIN
SEE SECTION 3.11
SECTION 4: CONTROL
VD0150
VO0029
VC0054
DUCT SIZE,
I
NSTALLING DUCTWORK AND
REGISTERS
SEE SECTIONS 3.7 AND 3.8
OUTDOOR CONNECTION
SEE SECTIONS 3.9 AND 3.10
- 12 -
VH0039
VH0043
VH0040
3
.1 INSPECT THE CONTENT OF THE BOX
• Inspect the exterior of the unit for shipping damage. Ensure there is no damage to the door, door latches, main switch, etc.
• Inspect the interior of the unit for damage. Ensure the blower assembly, insulation, prefilter, HEPA filter,heat recovery core, etc. are all intact.
• If the unit was damaged during shipping, contact your local distributor.
3.2 LOCATING AND MOUNTING THE UNIT
Choose an appropriate location for the unit.
• Within an area of the house where the ambiant temperature is between 10°C (50°F) and 30°C (86°F) (basement, furnace room, closet, etc.).
• So as to provide easy access to the interior of the unit, for filter maintenance.
• Away from hot chimneys and other fire hazards.
• Close to an exterior wall, so as to limit the length of the insulated flexible duct to and from the unit.
• Close to a drain. If no drain is close by, use a pail to collect run-off.
3.3 MOUNT THE PORTS ON THE UNIT
Mount the 5” to 6” oval ports on the top of the unit using the screws provided in the hardware box (4 screws #8 x 3/4” long per port).
NOTE: If an optional wall control has to be installed, do not install the front oval port (1) at this time.
3.4 MOUNT THE NAMEPLATE ON THE UNIT
Select your company nameplate (Venmar or vänEE) and snap it on the unit door. Discard the other nameplate.
3.5 HOW TO HANG THE UNIT
Use the 4 chains and springs in the hardware pack provided with the unit.
1
3. THH 1.0 UNIT INSTALLATION (CONT’D)
VO0049
CAUTION
Always install the unit vertically (with ports on top). Make sure the unit is level.
WARNING
To avoid risk of suffocation, discard the plastic bag wrapping the unit.
!
- 13 -
VO0060
VD0150
3. THH 1.0 UNIT INSTALLATION (CONT’D)
3.5 HOW TO HANG THE UNIT (CONTD)
Turn the switch knob to OFF position in order to unlock the door. Unlatch the door and open it.
NOTE: If preferred, the door can be removed. First, remove the stopper (A) located on the
right side of the door hinge, then, slide the door out of its hinge.
• Using a screwdriver, remove the 2 retaining screws of the front plate and carefully remove the front plate from the unit.
Insert the 4 hooks in the square holes and fix them to the unit using 4 screws #8 - 32 x 3/4”.
NOTE: If an optional wall controll has to be installed, go to Section 4.0 on pages 20 to 22.
If not, continue the installation.
Reinstall the front plate, the door and the door stopper.
Hang the unit to the floor joist, using 4 #8 x 1 1/2” screws, 4 chains and 4 spings.
See illustration beside.
VO0019
VO0020
VD0170
A
- 14 -
VD0151
3.6 PLANNING OF THE DUCTWORK
• Follow the instructions in Section 3.7 below to determine the appropriate duct diameters for your system. Do not use branch lines smaller than 4”ø (102 mm) diameter.
• Do not use wall cavities as ducts.
• Keep it simple. Plan for a minimum of bends and joints.
• Do not ventilate crawl spaces or cold rooms.
• If the house has two floors or more, be sure to plan for at least one exhaust register at the highest lived-in level of the house.
• Keep the length of insulated ducts to a minimum.
3.7 CALCULATING THE DUCT SIZE
Use the table below to ensure that the ducts you intend to install will be carrying air flows around the recommended values. Avoid installing ducts that will have to carry air flows near the maximum values and never install a duct if its airflow exceed the maximum value.
NOTE: Examples 3.7.1 and 3.7.2 use imperial measures. The same calculation applies to metric measures.
3.7.1 EXAMPLE OF CALCULATION:
Problem: My installation requires two exhaust registers (one for the kitchen, one for the bathroom). I will connect these registers to
a main duct which will connect to the unit (high speed performance value of 90 cfm). What size of duct should I use for the main exhaust duct and for the two end branches leading to the registers? (See illustration below.)
Solution: Simplified method.
(For a more detailed method of calculating duct size refer to the
ASHRAE or HRAI HANDBOOK). Main duct:
Table above indicates a 5” Ø duct: recommended air flow: 75 cfm; maximum air flow: 110 cfm.The high speed air flow of 90 cfm is close enough to the recommended value (75) and under the maximum value (110). Therefore a 5”Ø duct or larger is an appropriate choice for the main e
xhaust duct.
End branches: Each end branch will have to transport an air flow of 45 cfm (90 divided by 2). Table above indicates a 4ӯ duct: recommended air flow: 40 cfm; maximum air flow: 60 cfm. The high speed air flow of 45 cfm is close enough to the recommended value (40) and far enough away from the maximum value (60). Therefore a 4ӯ duct or larger is an appropriate choice for the 2 end br
anches.
2.7.2 EXAMPLE OF A DESIGN FOR A FULLY DUCTED SYSTEM FOR A UNIT HAVING A HIGH SPEED PERFORMANCE OF 90 CFM.
3. THH 1.0 UNIT INSTALLATION (CONT’D)
CAUTION
Do not attempt to recover the exhaust air from a dryer or a range hood. This would cause clogging of the filters and the heat recovery core.
4”(102 mm) 40 cfm 19 l/s 68 m3/h 60 cfm 28 l/s 102 m3/h 5”(127 mm) 75 cfm 35 l/s 127 m3/h 110 cfm 52 l/s 187 m3/h 6”(152 mm) 120 cfm 57 l/s 204 m3/h 180 cfm 85 l/s 306 m3/h
Duct Recommended Maximum
Diameter Air Flow Air Flow
VI0010
Main branch
5” or 6”ø 90 cfm
4”ø 45 cfm
5”ø 90 cfm
5”ø 90 cfm
4”ø 45 cfm
4”ø 45 cfm
4”ø 45 cfm
4”ø 45 cfm
End branches
- 15 -
VI0011
3.8 INSTALLING DUCTWORK AND REGISTERS
3.8.1 STAND ALONE SYSTEM
Stale air exhaust ductwork
• Install the stale air exhaust registers in the areas where the contaminants are produced: kitchen, living room, etc. Position the register as f
ar from the stairwa
y as possible and in such a way that the air circulates in all the lived-in spaces in the house.
• If a register is installed in the kitchen, it must be located at least 4 feet (1.2 m) from the range.
• Install the registers 6 to 12 inches (152 to 305 mm) from the ceiling on an interior wall OR install it in the ceiling.
• Use the provided red sticker dots to identify the duct.
Fresh / Filtered air distribution ductwork
• Install the fresh / filtered air distribution registers in the lowest level to ensure the greatest possible air circulation. Keep in mind that the fresh / filtered air registers must be located as far as possible from the stale air registers.
• Install the register in the ceiling OR 6 to 12 inches (152 to 305 mm) from the ceiling on an interior wall. The duct length should be at least 15’ (4.6 m). (The fresh / filtered air will then flow through the room and mix with room air, ensuring a continuous recirculating airflow.)
• Use the provided blue sticker dots to identify the duct.
How to connect the flexible duct to the unit ports
• Each port is identified on top of the unit (see illustrations below). Attach the fresh / filtered air to building duct to its corresponding port, using tie wrap (1). Then, attach the exhaust air from building duct to the other port (2).
NOTE: Use a 5’’or 6’’ insulated duct if the duct will have to go through extreme temperature (e.g.: in northern area, not heated attic
in winter or attic not cooled in southern area). Also. if you plan to stop the unit for more than 12 hours, we recommend to cover the duct with R12 insulation.
3. THH 1.0 UNIT INSTALLATION (CONT’D)
WARNING
Never install a stale air exhaust register in a closed room where a combustion device operates, such as a gas furnace, a gas water heater or a fireplace.
!
- 16 -
12
VO0061
VO0062
3. THH 1.0 UNIT INSTALLATION (CONT’D)
3.8 INSTALLING DUCTWORK AND REGISTERS (CONTD)
3.8.2 C
ENTRAL DRAW POINT
NOTE: For this type of installation, it is not essential that the furnace blower runs when the unit is in operation, but we recommend it.
Fresh / Filtered air distribution ductwork (Return side connection)
• Locate the opening for the fresh / filtered air ductwork on the furnace / air handler return duct at a minimum linear distance of 9’
10”
(3 m) upstream (return side: A+B+C).
• Attach this duct to the
FRESH AIR TO BUILDING
port (see icon on the top of the unit), using tie wrap
and duct tape. Use the provided blue sticker dots to identify the duct
Stale air exhaust ductwork
Same as for Stand Alone System, described in point 3.8.1.
3.8.3 RETURN-RETURN
NOTE: To avoid the cross-contamination and achieve highest efficiencies, the fur
nace/air handler blower must always be ON (or
the unit efficiency will be affected).
Fresh / Filtered air distribution ductwork (Return side connection)
Same as for Central Draw Point, described in point 3.8.2.
Stale air exhaust ductwork (Return side connection)
• Locate the take-off duct opening at least 3’ (0.9m) from the filtered air ductwork connection. Proceed as for the filtered air ductwork, but instead of using the blue dot sticker to identify the duct, use the red dot.
• Attach this duct to the
EXHAUST AIR FROM BUILDING
port (see icon on the top of the unit) using tie
wrap and duct tape.
Minimum 3’ (0.9 m)
from fresh / filtered air
ductwork connection
WARNING
When performing duct connections, always use approved tools and materials. Respect all corresponding laws and/or safety regulations. Please refer to your local building code.
!
WARNING
When performing duct connections, always use approved tools and materials. Respect all corresponding laws and/or safety regulations. Please refer to your local building code.
!
- 17 -
A
B
C
VD0153
VO0061
VD0154
VO0062
3.9 INSTALLING INSULATED FLEXIBLE DUCTS
Use the following procedure for connecting the insulated flexible ducts to the Tandem® transition* (
EXHAUST AIR TO OUTSIDE
and
FRESH AIR FROM OUTSIDE
).
• The joist opening needed to install the Tandem®* transition must be 9 3/4” (248 mm) minimum. Also, the maximum height of the Tandem® transition* is 8 3/4” (222 mm). See Tandem® transition* end view below.
NOTE: If the joists are perpendicular to the ducts, or if the connection to the exterior hood is in a limited area, your installation will
need two exterior hoods instead of one. In this case, do not use the Tandem® transition*. Identify each insulated duct. For fresh air from outside duct, use the blue sticker dots (one dot at each end). For exhaust air to outside duct, use the red sticker dots (one dot at each end). Then, go to point 3.9.2 and refer to the optional single hood enclosed instructions.
*Patent pending.
3.9.1 CONNECTION TO TANDEM® TRANSITION
1. F
or each duct, pull back the insulation to expose the interior flexible duct.
2. Connect the interior flexible duct to the smaller part of the Tandem® transition (5’’ oval) using a 24’’ tie wrap. NOTE: If you are using a 6’’ diameter insulated duct, use the bigger part of the Tandem® transition (6’’ oval).
3. Pull the insulation over the joint. Pull the vapor barrier over the insulation.
4. Apply duct tape gently to the joint in order to make an air
tight seal. See figures below.
Identify each insulated duct. For fresh air from outside duct, use the blue sticker dots (one dot at each end). For exhaust air to outside duct, use the red sticker dots (one dot at each end). Be careful to identify the exhaust air to outside duct (red dot) at the upper
section of the transition.
3. INSTALLATION OF THE THH 1.0 UNIT (CONT’D)
CAUTION
Make sure the vapor barrier on the insulated ducts does not tear during installation.
1
2
3
4
- 18 -
9 3/4"
248 mm
8 3/4"
222 mm
VD0118
VJ0025
VJ0023
VJ0022
VJ0024
3.9 INSTALLING INSULATED FLEXIBLE DUCTS (CONTD)
3.9.2 C
ONNECTION TO THE 5’’ TO 6’’ OVAL PORTS OF THE UNIT
Use the following procedure for connecting the insulated flexible ducts to the 5’’ to 6’’oval ports of the unit (
EXHAUST AIR TO OUTSIDE
and
FRESH AIR FROM OUTSIDE
).
1. Pull back the insulation to expose the flexible duct.
2. Connect the interior flexible duct to the smaller part of the port (5’’ oval) using a
24’’ tie wrap. NOTE: If you are using a 6’’ diameter insulated duct, use the bigger part of the
port (6’’ oval).
3. Pull the insulation over the joint and tuck it between the inner and outer rings of the port. Pull the vapor barrier over the insulation and over the outer ring of the port.
4. Apply duct tape gently to the joint in order to make an airtight seal.
5. Repeat steps 1 to 4 for the other 5’’ to 6’’ port.
See figure beside to find the
EXHAUST AIR TO OUTSIDE
(1)
and
FRESH AIR FROM OUTSIDE
(2) oval ports on the top of the unit.
Be careful to connect the right insulated duct to its corresponding port.
3. INSTALLATION OF THE THH 1.0 UNIT (CONT’D)
1
2
CAUTION
Avoid compressing the insulation when you pull the tape tightly around the joint. Compressed insulation loses its insulation properties and causes water dripping due to condensation on the exterior surface of the duct.
- 19 -
VJ0016
VJ0017
VJ0018
VJ0019
VJ0020
3. INSTALLATION OF THE THH 1.0 UNIT (CONT’D)
3.10 INSTALLING DUAL EXTERIOR HOOD*
3.10.1 ASSEMBLING DUAL EXTERIOR HOOD
Exterior dual hood comes in separate parts. Using 2 #8 x 3/4” screws, assemble the top metal screen and the plastic grille to the dual exterior hood. Then, slide the bottom metal screen to the dual exterior hood. See illustration beside.
*Patent pending
3.10.2 LOCATING THE DUAL EXTERIOR HOOD
The dual exterior hood must be installed at a minimum distance of 18 inches (457 mm) from the ground. See illustration beside.
3.10.3 CONNECTING TANDEM® TRANSITION TO THE DUAL EXTERIOR HOOD
1. Using a jig saw, cut a 6’’ diameter hole in the exterior wall and insert the Tandem®
transition through this hole.
1) EXHAUST AIR TO OUTSIDE duct
2. Joint the end of the Tandem® transition to the rear of the exterior backplate. Secure
with 2 Xmas tree pins and seal properly with duct tape.
WARNING
Make sure this hood is at least 3 feet (0.9 m) away from any of the following:
• High efficiency furnace vent. • Any exhaust from a combustion source.
• Gas meter exhaust, gas barbecue-grill. • Garbage bin and any other source of contamination.
!
1
CAUTION
The Tandem® transition must be inserted in such a way that the
EXHAUST AIR TO OUTSIDE
duct will be located
on the top.
Xmas tree pin
CAUTION
The exterior backplate must be installed with the word “TOP” pointing upward.
- 20 -
VO0024
VD0083
VD0084
18''
(457 mm)
VD0085
3. INSTALLATION OF THE THH 1.0 UNIT (CONT’D)
3.11 CONNECTING THE DRAIN
1. Remove the door by turning the switch knob to the OFF position (to unlock the door). Then, unlatch the door and open it. Slide out the core assembly to access the 2 drain fitting hole locations (1). Punch out the holes.
2. Hand tighten the 2 plastic drain fittings (1) using the gaskets (2) and nuts (3) as shown. Close the door.
1
2
3. Cut 2 sections of plastic tubing;
one 7’’ (178 mm) long and one 27’’ (686 mm) long, and attach them to each drain fitting as shown.
3
4. Join these 2 sections to the ‘’T’’
junction and main tube as shown.
4
5
Tie-wrap
To drain
5. Make a water trap loop in the tube to prevent the unit from drawing unpleasant odors from the drain source. Make sure this loop is situated BELOW the ‘’T’’ as shown. This will prevent water from being drawn back up into the unit in case of negative pressure. Run the tube to the floor drain or an alternative drain pipe or pail. Be sure there is a slight slope for the run-off.
3.10 INSTALLING DUAL EXTERIOR HOOD* (CONTD)
3.10.3 C
ONNECTING TANDEM® TRANSITION TO THE DUAL EXTERIOR HOOD (CONTD)
3. Lean the exterior backplate to the exterior wall. Using 4 #8 x 1 1/2” screws, fix it to the wall. Seal the outline with caulking.
4. Snap the assembled exterior hood to its backplate and secure with 2 provided screws (#8 x 3/4” long).
screw
- 21 -
1
VD0086
VD0087
1
VO0025
VO0028
2
3
VO0046
27''
686 mm
VO0027
'
(178 mm)
VO0029
4.1 MAIN SWITCH
These unist are equipped with a 3-position main switch, located on the front panel.
4.2 OPTIONAL WALL CONTROLS
The optional wall control part number for the HEPA 3.2 unit is 04862 (for Venmar unit) or 05439 (for vänEE unit).
The optional wall control part number for the THH 1.0 unit is 04391 (for Venmar unit) or 05536 (for vänEE unit).
HEPA 3.2 THH 1.0
#04862 or #05439 #04391 or #05536
4.3 DIMENSIONS
Dimensions are the same for both optional wall controls.
4.4 INSTALLATION OF THE OPTIONAL WALL CONTROL
1.Determine the more convenient location for the control.
2. Remove the cover plate control (1). If you prefer to have your optional main control mounted on an approved outlet box or an approved mounting bracket (not included), discard the backplate (2).
3.Take one end of the cable and pass it through the wall control backplate (or outlet box or mounting bracket).
OFF:
U
NIT IS OFF AND
DOOR IS
UNLOCKED
.
BOOST: UNIT IS OPERATING
ON HIGH SPEED.
VC0054
VC0055
CAUTION
Never install more than one optional wall control per unit.
WARNING
Always disconnect the unit before making any connections. Failure in disconnecting power could result in electrical shock or damage of the wall control or electronic module inside the unit.
!
1
2
- 22 -
VC0053
NORMAL/REMOTE: UNIT IS OPERATING ON
NORMAL SPEED.THIS IS THE RIGHT POSITION WHEN AN OPTIONAL WALL CONTROL IS USED
.
WARNING
To avoid risk of electrical shocks, never install another wire in the same electrical box than the one for the optional wall control.
!
4. CONTROLS
VC0049
4.4 INSTALLATION OF THE OPTIONAL WALL CONTROL (CONTD)
4. Splice back this end of the cable to access to the 4 wires. Remove the insulated sleeve of each wire ends. Make a loop with each bare
end wire to hook them to their corresponding screw. Connect YELLOW wire to “Y” screw, RED wire to “R” screw, GREEN to “G” screw and BLACK to “B” screw. See illustration below.
5. Pass the other end of the cable through the wall. Reinstall the cover plate. Using wall anchors (not included) and provided screws, mount the wall control on the wall. See illustrations below.
1) Wall anchors 4) Control 1) Outlet box 3) Control
2) Control cable 5) Screws 2) Control cable 4) Screws
3) Control backplate
6. Route the cable to the unit.
7. If it is not done yet, remove the front 8’’ (HEPA 3.2 unit) or the 5” to 6” (THH 1.0 unit) oval port (1).
HEPA 3.2 unit THH 1.0 unit
4. CONTROLS (CONT’D)
1
1
1
3
4
5
2
3
4
1
CAUTION
Keep control low voltage wiring at least 1’ (305 mm) away from motors, lightning ballast, light dimming circuit and power distribution panel. Do not route control wiring along house power wiring. Avoid poor wiring connections. Failure to follow these practices can introduce electrical interference, which can cause erratic control operations.
BLACK
wire
YELLOW
wire
GREEN
wire
RED wire
2
WARNING
Make sure that the wires do not short circuit between themselves or by touching any other components on the wall control.
!
- 23 -
VC0051
VC0052
VO0045
VO0060
4.4 INSTALLATION OF THE OPTIONAL WALL CONTROL (CONTD)
8. Remove the front panel of the unit by unscrewing its retaining screws.
9. Using a small rod, pierce a hole through the unit at the end of the wire channel. (See
picture beside.) Splice back the end of the cable to access the 4 wires. Remove the insulated sleeve of each wire ends. Insert the end of the cable through the unit, using the small hole previously done.
10. In order to access the unit PCB terminals, remove the side door located on the
electrical box and punch out its knock out. Run the cable through the knock-out hole and connect each wire in their corresponding terminal (YELLOW in “Y”, RED in “R”, GREEN in “G” and BLACK in “B”). NOTE: Push forward slightly on the little tabs (1) to ease insertion of each wires. See
picture beside.
11. Reinstall the side door on the electrical box and the front oval port on the unit.
12. Route the wire through its channel and reinstall the front panel on the unit.
See picture beside.
13. If the installation is not completed, return to Section 2 on page 8 ( for HEPA 3.2 unit) or Section 3 on page 13 (for THH 1.0 unit).
If the installation is completed, plug the unit.
NOTE: When using an optional wall control, the main s
witch on the unit must always be positioned to NORMAL/REMOTE.
VD0089
VE0049
1
VD0088
VO0019
4. CONTROLS (CONT’D)
- 24 -
4. CONTROLS (CONT’D)
4.6 OPERATING #04391 OR #05536 CONTROL
4.6.1 #04391 OR #05536 CONTROL DESCRIPTION
4.6.2 USING #04391 or #05536 CONTROL
• OFF : To stop the unit, slide the button on this position.
• N
ORMAL : For a day-to-day usage, slide the button on this position. The unit then will operate on normal speed.
• B
OOST : For a high speed operation, slide the button on this position.
Generally used when extreme conditions occur, e.g.: parties, smokers, etc.
• R
ECIRCULATION : For a normal speed operation, without exchanging air with the outside, slide the button on this position.
This mode is ideal when the inside air is too dry, or during extremely cold outside temperature. It can be used also to recirculate the heat coming from a wood stove throughout the house, or the fresh air from a cooling system.
VC0048
NORMAL INDICATOR:
LIGHTS UP WHEN SLIDE SWITCH IS ON NORMAL
POSITION.UNIT IS OPERATING
ON NORMAL SPEED.
FRESH AIR INDICATOR:
LIGHTS UP WHEN SLIDE
SWITCH IS ON NORMAL OR
BOOST POSITION.
FILTER MAINTENANCE
INDICATOR:
FLASHES WHEN IT IS TIME TO
REPLACE PREFILTER AND WASH CORE FILTERS
.SEE
SEMI-ANNUAL MAINTENANCE
IN
SECTION 7.
LIGHTS UP WHEN IT IS TIME
TO REPLACE FILTER AND
PREFILTER AND WASH CORE
FILTERS
.SEE ANNUAL
MAINTENANCE IN SECTION 7.
RESET FILTER HOLE:
ONCE THE MAINTENANCE DONE, RESET THE FILTER MAINTENANCE
INDICATOR BY CAREFULLY INSERTING A SMALL ROD
(E.G.: PAPER
CLIP) IN THE RESET FILTER HOLE, DURING 1 SECOND.THE FILTER MAINTENANCE INDICATOR WILL TURN OFF.
BOOST INDICATOR:
LIGHTS UP WHEN SLIDE
SWITCH IS ON BOOST
POSITION
.UNIT IS OPERATING
ON HIGH SPEED.
RECIRCULATION INDICATOR:
LIGHTS UP WHEN SLIDE
SWITCH IS ON
RECIRCULATION.UNIT IS
OPERATING ON NORMAL
SPEED.
4.5 OPERATING #04862 OR #05439 CONTROL
4.5.1 #04862 OR #05439 CONTROL DESCRIPTION
4.5.2 USING #04862 OR #05439 CONTROL
• OFF : To stop the unit, slide the button on this position.
• NORMAL : For a day-to-day usage, slide the button on this position. The unit then will operate on normal speed.
• B
OOST : For a high speed operation, slide the button on this position.
Generally used when extreme conditions occur, e.g.: parties, smokers, etc.
VC0054
OFF:
U
NIT IS OFF.
POWER INDICATOR:
LIGHTS UP WHEN SLIDE SWITCH
IS ON NORMAL OR BOOST
POSITION.
FILTER MAINTENANCE
INDICATOR
:
FLASHES EVERY MINUTE TO
INDICATE IT IS ON DUTY.
FLASHES EVERY SECOND WHEN
IT IS TIME TO REPLACE
PREFILTER
.SEE SEMI-ANNUAL
MAINTENANCE IN SECTION 7.
LIGHTS UP WHEN IT IS TIME TO
REPLACE FILTER AND
PREFILTER
.SEE ANNUAL
MAINTENANCE IN SECTION 7.
NORMAL:
UNIT IS OPERATING ON
NORMAL SPEED.
BOOST:
UNIT IS OPERATING ON
HIGH SPEED.
RESET FILTER HOLE:
ONCE THE MAINTENANCE DONE, RESET THE FILTER
MAINTENANCE INDICATOR BY CAREFULLY INSERTING A SMALL ROD
(E.G.: PAPER CLIP) IN THE RESET FILTER
HOLE, DURING 1 SECOND.THE FILTER MAINTENANCE INDICATOR WILL TURN OFF.
- 25 -
- 26 -
5. WIRING DIAGRAMS
WARNING
Risk of electrical shocks. Before performing any maintenance or servicing, always disconnect the unit from its power source.
!
5.1 HEPA 3.2 WIRING DIAGRAM
5.2 THH 1.0 WIRING DIAGRAM
Critical characteristic
Field wiring
remote control
(See Note 3)
R
BKGY
4 3 2 1
J6
A1
ELECTRONIC ASSEMBLY
F1
J5
See
J3
Note 1
1 2 31 2
J4
BK
G
G
9.6V, 60Hz,
TRANSFORMER
1. For continued fire protection. Use specified UL
2. If any of the original wire, as supplied, must be replaced, use the same equivalent wire.
3. Field wiring must comply with applicable codes, ordinances and regulations.
3. Remote control available (class 2 circuit). See installation manual.
VE0069A
BL
T1
W
120V
60V
Neutral
UL Class 2
NOTES
listed/CSA Certified line fuse.
3 2 1
nc
W
W1
120V, 60Hz
J2
1 2 3
soldered
wires
Access panel
mechanical interlock
S1
L
BN
3
nc
SL S1 S2
Y
1
a
b
c
2
G
S1
L
a (nc) OFF b c
9.6V 60Hz
Class 2
120V, 60Hz
Line
J3-1
F1
S1 S2 SL
J4-1
J4-2
60V 60Hz
J5-1
J5-2
Ground
motor
capacitor
J2-3
J2-1
K1
K2
120V, 60Hz
Fan motor
Neutral
J3-3
J2-2
J4-3
M1
BN
BK
G
G
Class 2 low voltage field wiring
BL
BK
FAN MOTOR
G
High voltage factory wiring
COLOR CODE
BK BLACK BL BLUE BN BROWN G GREEN
RRED W WHITE Y YELLOW nc
no connection
K2
K1
ELECTRONIC ASSEMBLY
POSITION
a
b
c
S1 LOGIC
CONTACT
L
L - 1
L - 2
J6
4 3 2 1
MODE
Off
Normal / Remote
Boost
Field wiring
remote control
Critical characteristic
BGY
4 3 2 1
J6
1 2 31 2
BK
T1
120V
60V
Neutral
UL Class 2
BL
W
G
G
9.6V, 60Hz,
TRANSFORMER
1. For continued fire protection. Use specified UL listed/CSA Certified line fuse.
2. If any of the original wire, as supplied, must be
replaced, use the same equivalent wire.
3. Field wiring must comply with applicable codes,
ordinances and regulations.
3. Remote control available (class 2 circuit).
See installation manual.
VE0068A
R
ELECTRONIC ASSEMBLY
J5
Note 1
J4
120V, 60Hz
NOTES
Field wiring
remote control
(See Note 3)
A1
SL
F1
See
3 2 1
W1
J3
nc
W
soldered
wires
1 2 3J21 2
BK
J1
G
o
-t
R1
BK
2 1
J8
BN
S1 S2
G
G
High voltage factory wiring
Class 2 low voltage factory wiring
Class 2 low voltage field wiring
Access panel
mechanical interlock
S1
L
a
b
c
3
nc
G
Y
M2
Y
Y
DAMPER MOTOR
M1
BN
BL
BK
FAN MOTOR
G
1
2
Damper motor
Fan motor
S1 LOGIC
CONTACT
L
L - 1
L - 2
120V, 60Hz
Neutral
J3-3
J1-2
J2-2
J4-3
J6
4 3
2 1
MODE
Off
Normal / Remote
Boost
Field wiring
remote control
120V, 60Hz
Line
J3-1
F1
K3
J4-1
9.6V 60Hz
Class 2
J4-2
60V 60Hz
J5-1
G
S1
L
J5-2
a (nc) OFF
b
c
BK BLACK BL BLUE BN BROWN G GREEN
S1 S2 SL
COLOR CODE
K1
K2
RRED W WHITE Y YELLOW nc
no connection
CPU
motor
capacitor
Ground
J1-1
J2-3
J2-1
K1
K2
K3
ELECTRONIC ASSEMBLY
POSITION
a
b
c
- 27 -
6. BALANCING PROCEDURE (THH 1.0 ONLY)
6.1 WHAT YOU NEED TO BALANCE THE UNIT
• A magnehelic gauge capable of measuring 0 to 0.5 inches water gauge (0 to 125 Pa) and 2 plastic tubes.
• Two flow collars (the size will vary depending of duct diameter).
Flow collar
6.2 PRELIMINARY STAGES FOR BALANCING THE UNIT
Seal all the unit ductwork with tape. Close all windows and doors. Turn off all exhaust devices such as: range hoods, dryers and bathroom fans. Make sure balancing dampers are fully open
(F and G in figure below).
Choose an appropriate location for the 2 flow collars according to figure below:
• On the exhaust air duct (first measuring location, A)
• On the fresh/filtered air distribution duct (second measuring location, B)
• At least 36” (914 mm) away from the unit; at least 12” (304 mm) before or after 90° elbow and at least 12” (304 mm) away from a register.
• At least 12” (304 mm) away a from a balancing damper (F and G in figure below).
(
)
(30m)4m36(
)
36
(
)
OR
G
(
)
(
)
Insert the flow collars in the ducts at each location (A et B on figure above). Make sure their arrows are pointing in the direction of the airflow. Tape collars in place temporarily.
6.3 INSTALLATION OF FLOW COLLAR
6.4 BALANCING PROCEDURE
1. Set the unit to high speed. Make sure that the furnace blower is ON if the installation is in any way connected to the ductwork of the cold air return. If not leave furnace blower OFF.
2. Place the magnehelic gauge on a level surface and adjust it to zero.
3. Connect tubing from gauge to flow collar in exhaust air stream (location A in illustration above). Be
sure to connect the tubes to their appropriate high / low fitting. If the gauge reading drops to below
zero, reverse the tubing connections.
NOTE: It is better to start with the exhaust air flow reading because the exhaust typically has more
restriction than the fresh air, especially in cases of stand alone and central draw point installations.
Hold or place the magnehelic gauge upright and level. Record the reading.
4. Move tubing to the other side of the unit (location B in illustration above and note reading. Adjust the fresh air balancing damper F until the reading at B is approximately the same as the reading at A. If the reading at B is less than the reading at A then go back and adjust the exhaust balancing damper G to equal the fresh air flow.
5. Remove flow collars and reconnect the duct, then, seal with duct tape. Write the required airflow information on a label and stick it near the unit for future reference: (date, maximum speed airflows, your name and phone number and business address). NOTES:
• Most flow collar kits provide a conversion chart situated on the collar which enables you to convert magnehelic gauge readings to equivalent cfm values.
• A difference of ± 10 cfm ( ± 0.015 inches water gauge) between the 2 readings isconsidered balanced.
• If you are using only one flow collar, then, after completing the first reading, transfer this measuring device to the other side of the unit and take the second reading.
LOW
HIGH
F
LOW
O
L
O
W
H
IG
H
F
L
O
W
O
VP0005
VP0014A
304mm
304mm
914mm
304mm
914mm
VP0003
VP0004
7. MAINTENANCE
7.1 SEMI-ANNUAL MAINTENANCE (ESSENTIAL)
If your unit is equipped with an optionnal wall control (04862 / 05439 or 04391 / 05536) you should perform this maintenance when the Filter Maintenance light is flashing. Otherwise, this maintenance must be performed every 6 months to ensure your unit proper operation for years to come. Follow these steps:
1. Turn switch knob to OFF to unlock the door.
2. Unlatch the door and open it. Clean the inner side of the door with a clean damp cloth, then wipe with a dry one.
3. Slide out the heat recovery module (THH 1.0 units only) and the filter cartridge from the unit.
1) Heat recovery module 2) Tabs
NOTE: To remove the filter cartridge, pull on its tabs (2).
4. Using your thumbs, push on the prefilter side to disengage it from the filter cartridge. Then, slide it out of the filter cartridge and discard it. Install the new prefilter by reversing this operation.
1) Filter cartridge
2) Prefilter
5. Clean the inside walls of the unit with a clean damp cloth, then wipe with a dry one.
WARNING
Risk of electrical shocks. Before performing any maintenance or servicing, always disconnect the unit from its power source.
!
VD0112
2
1
2
VD0092
VD0093
1
VD0091
- 28 -
7.1 SEMI-ANNUAL MAINTENANCE (ESSENTIAL) (CONTD)
For
THH unit only
Wash the 2 core filters under hot water with mild soap. Soak the core in a solution of warm water and mild soap. Rinse the core filters and the core thoroughly and let dry before reinstalling them in the unit.
1) Core filters
2) Core
NOTE: Make sure the damper spring (1) is still inside the left front port opening before
reinstalling the recovery module.
1) Damper spring
6. Close the door, close the latches and turn ON the switch knob to its previous position.
7. If your unit is equipped with a wall control (04862 / 05439 or 04391 / 05536), reset the filter maintenance indicator by inserting a
small rod (eg: paper clip end) into the reset filter hole of the optional wall control. Press lightly until the Filter Maintenance indicator light turns off.
7.2 ANNUAL MAINTENANCE (ESSENTIAL)
If your unit is equipped with an optional wall control (04862 / 05439 or 04391 / 05536) you should perform this maintenance when the Filter Maintenance light stays ON. Otherwise, this maintenance must be performed once a year to ensure proper operation of your unit for years to come. Proceed as the Semi-annual Maintenance (Section 7.1), but instead of replacing the prefilter (point 4), discard the complete HEPA Filter cartridge (including prefilter). Install a new HEPA filter cartridge (or a new pleated filter cartridge) with a new prefilter on it.
7.3 MASTER RESET
Use the master reset only if you replace the filters before the annual maintenance indicator is on. By inserting a small rod (eg: paper clip end) for 5 seconds or more into the reset filter hole of the optional wall control, a master reset will be done and both biannual and annual maintenance filter are reset.
04862 / 05439 Control
: The filter maintenance indicator will flash 1/4 second if the wall control is on Normal or Boost position.
04391 / 05536 Control: If the wall control is in ”Off” position, “Fresh air” light indicator will flash for 1 second. If the wall control is in
”Normal” or “Boost” position, the unit motor, the “Fresh air” light indicator and speed light indicator (“Normal” or
“Boost”) will turn off for 3 seconds. If the wall control is in ”Recirculation” position, the “Recirculation” light indicator and the unit motor will turn off for 3 seconds.
7. MAINTENANCE (CONT’D)
1
1
2
VD0091
VD0120
1
- 29 -
WARRANTY
Venmar Ventilation inc. and vänEE Canada warrant to the original consumer purchaser of their products, that such products will be
free from defects for a period of two (2) years, from date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. VENMAR VENTILATION INC. AND VÄNEE CANADA WILL NOT BE HELD RESPONSIBLE FOR ANY CLAIMS OVER THE ORIGINAL PURCHASE PRICE OF A WHOLE-HOUSE HEPA AIR PURIFIER SYSTEM, NOR HELD RESPONSIBLE FOR SUBSEQUENT DAMAGE OR INCIDENT.
During the period stated above, Venmar Ventilation Inc. or vänEE Canada will, at their opinion, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO ANY CORE FILTERS (THH 1.0 MODELS ONLY) FILTER AND PREFILTER. This warranty does not cover a) normal maintenance and service, b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repairs made by other than Venmar Ventilation inc. or vänEE Canada or c) a faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the 2-year period as specified for the express warranty. Some states or provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
VENMAR’S OR VÄNEE ‘S OBLIGATION TO REPAIR OR REPLACE AT VENMAR’S OR VÄNEE’S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. VENMAR VENTILATION INC. AND VÄNEE CANADA WILL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. SOME STATES OR PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
This warranty gives you specific legal rights and you may also have other rights, which vary from province to another. This warranty supersedes all prior warranties.
To contact warranty service call 1-800-567-3855. In order to qualify for a warranty claim, the owner of a Venmar or vänEE whole-house HEPA air purifier system must have the model and serial number along with a proof of the original purchase date. In each case, costs for the removal of a defective part (and/or unit) and installation of a new or repaired one and travel costs are not covered by this warranty.
In case of discrepancies between the english version of the warranty and french version, the english version will prevail. VVI, 550 Lemire Blvd., Drummondville, Qc Canada J2C 7W9
10. WARRANTY
PROBLEMS SOLUTIONS
• Check breaker or fuse in main distribution panel.
1.Unit does not start at Normal • Check there is 120V at the electrical outlet. or Boost position. • Make sure the unit main switch is properly set in Normal or Boost position.
• If a wall control is connected, disconnect control wire from the unit, then make sure the unit main switch is properly set in Normal position.
2. Unit does not run at Normal • If a wall control is used, disconnect control wire from the unit. Then, if the unit runs at speed, but runs at Boost. Normal speed, check control wiring and wall control connections.
3. Unit is not operating as per • Check if the unit main switch is in “Normal/Remote” position. the selected mode. • Check wall control wiring.
4. Wall control indicators do not work
• Check wall control wiring.
properly or not at all.
5. On 04391 / 05536 wall control only,
• Check if the unit main switch is in “Normal/Remote” position.
1 or 2 light indicators flash every second. • Check wall control wiring.
9. TROUBLESHOOTING
If the problem is still not solved, call your installer or the nearest approved Service Center. Also, you can reach the Customer Service Department at the following toll free telephone number: 1 800 567-3855.
*Items 3, 4, 5 and 6 are optional. All listed parts are available where you bought your unit. NOTE: Please note that parts not listed are not available; those parts require assembly knowledge that only manufacturer can garantee.
No. Description
Part Venmar vänEE Venmar vänEE
Number HEPA 3.2 HEPA 3.2 THH 1.0 THH 1.0 1 Prefilter Kit (2) 05123 1 1 1 1 2 HEPA Pleated Filter Kit 04803 1 1 1 1 3 Wall Control ** 04862 1 - - ­4 Wall Control ** 05439 - 1 - ­5 Wall Control ** 04391 - - 1 ­6 Wall Control ** 05536 - - - 1
8. PARTS ORDERING CHART
- 30 -