Venmar FAE125, VFAE125, FAE 125M, VFAE125M Installation And User Manual

09219 rev. 02
INSTALLATION AND USER MANUAL
VB0134
FURNACE AIR EXCHANGER WITH HEAT RECOVERY
MODELS
ADDRESS OF YOUR INSTALLER
FAE125
FAE 125M
VFAE125M
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER
CUSTOMER SERVICE PHONE NUMBER: 1-800-567-3855
2
This manual uses the following symbols to emphasize particular information:
NOTE: Indicates supplementary information needed to fully complete an instruction.
ABOUT THIS MANUAL
WARRANTY
Venmar Ventilation inc. or vänEE Canada warrants to the original purchaser of its products that such products will be guaranteed against all manufacturing defects and defective material for a period of two (2) years from the date of original purchase. The heat recovery core is protected by a limited lifetime warranty.
THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.VENMAR VENTILATION INC. OR vänEE CANADA WILL NOT BE HELD RESPONSIBLE FOR ANY CLAIMS OVER THE ORIGINAL PURCHASE PRICE OF A FURNACE AIR EXCHANGER WITH HEAT RECOVERY, NOR HELD RESPONSIBLE FOR SUBSEQUENT DAMAGE OR INCIDENT.
During the period stated above, Venmar Ventilation Inc. or vänEE Canada will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. This warranty does not cover a) normal maintenance and service, b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repairs made by other than Venmar Ventilation inc. or vänEE Canada, or c) a faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the 2-year period as specified for the express warranty. Some jurisdictions do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
VENMAR VENTILATION INC. OR vänEE CANADA'S OBLIGATION TO REPAIR OR REPLACE AT VENMAR OR vänEE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. VENMAR OR vänEE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
This warranty gives you specific legal rights and you may also have other rights, which vary from province to another. This warranty supersedes all prior warranties. To contact Venmar Ventilation inc. or vänEE Canada warranty service, call 1-800-567-3855.
In order to qualify for a warranty claim, the owner of a Furnace Air Exchanger with heat recovery must have the model and serial number along with a proof of the original purchase date. At the time of requesting service, describe the nature of any defect in the product or part.
WARNING
Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death.
!
CAUTION
Denotes an instruction which, if not followed, may severely damage the unit and/or its components.
3
ABOUT THESE UNITS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S), OBSERVE THE FOLLOWING:
1. This unit is intented for residential installation only.
2. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
3. This unit is not designed to provide combustion and/or dilution air for fuel-burning appliances.
4. Do not install in a cooking area or connect directly to an appliance.
5. Before servicing or cleaning the unit, disconnect power from HVAC system.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.
7. Do not use FAE125M and VFAE125M units with any solid-state speed control device. Use only with Dehumidistat wall control provided with the unit.
8. This unit must be installed in a weatherized location, out of direct sunlight and protected from the elements.
9. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the telephone number listed in the warranty.
10. When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
11. Servicing shall be done by qualified service personnel.
12. When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses.
!
CAUTION
1. For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. Intended for residential installation only in accordance with the requirements of NFPA 90B and in compliance with all local and national codes that are applicable.
3. Be sure to duct air outside. Do not intake/exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or garage.
4. To avoid premature clogged filter, turn OFF the unit during construction or renovation.
5. Please read the unit specification label on the product for further information and requirements.
6. At least once a year, the unit mechanical and electronic parts (if need be) should be inspected by qualified service personnel.
7. The FAE125M or VFAE125M must be connected to a 24-volt class 2 circuit only.
4
1. S
ERVICE PARTS ................................................................................... 5
2. TECHNICAL DATA ................................................................................ 6-7
2.1 AIR DISTRIBUTION ....................................................................................... .6
2.2 H
EAT RECOVERY .........................................................................................6
2.3 DURING COLD WEATHER...............................................................................6
2.4 DIMENSIONS ...............................................................................................7
2.5 SPECIFICATIONS ........................................................................................... 7
2.6 PERFORMANCE CHART .................................................................................7
3. TYPICAL INSTALLATIONS .......................................................................... 8
4. INSTALLATION ................................................................................... 8-10
4.1 LOCATING AND MOUNTING THE UNIT................................................................ 8
4.2 CONNECTING DUCTS TO THE UNIT .................................................................. 9
4.3 INSTALLING EXTERIOR HOODS ........................................................................ 9
4.4 CONNECTING THE DRAIN ............................................................................. 10
5. AIR FLOW BALANCING ..................................................................... 10-12
6. WALL CONTROL (FAE125M AND VFAE125M ONLY) .............................. 12
6.1 INSTRUCTIONS REGARDING WALL CONTROL .................................................. .12
6.2 WALL CONTROL CONNECTION TO THE UNIT ................................................... 12
7. M AINTENANCE ..................................................................................... 13
8. TROUBLESHOOTING .............................................................................. 14
TABLE OF CONTENTS
5
1. S ERVICE PARTS
1
3
4
5
6
8
7
9
10
11
12
13
2
REPLACEMENT PARTS AND REPAIRS
In order to ensure your ventilation unit remains in good working condition, you must use the manufacturer genuine replacement parts only. The manufacturer replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. The manufacturer recommends to contact a certified service depot for all replacement parts and repairs.
NO.PART NO.DESCRIPTION
FAE125 OR
VFAE125
FAE125M OR
VFAE125M
1 02253 B
ALANCING DAMPER 22
2 02256 PORT FOR BALANCING DAMPER 22 3 18620 HEAT RECOVERY CORE 11 4 09214 FILTER 11 5 18619 DOOR ASSEMBLY (WITH SCREWS)1 1
6 18618
MOTORIZED DAMPER ASSEMBLY (WITH DAMPER SPRING)
—1
7 18682 DRAIN CONNECTOR WITH FOAM 11 8 18683 DOOR SCREWS (4 PER KIT)1 1
9 02021 PORT 22 10 09221 DAMPER SPRING 11 11 09220 H
ARDWARE KIT 11
12 18617 DAMPER MOTOR ASSEMBLY —1 13 10177 DAMPER MOTOR COVER —1
VL0037