Venmar FAE115, vFAE115, uFAE115, FAE115M, vFAE115M Installation And User Manual

...
Installation and User Manual
Address of your installer
04423 07/04/00
Furnace Air Exchanger with
Heat Recovery
CANADIAN MODELS US MODELS
FAE115 vFAE115 uFAE115
INSTALLER: LEAVE THIS MANUAL TO HOMEOWNER
Customer Service Phone Number: 1-800-567-3855
VB0026
This manual uses the following symbols to emphasize particular information:
NOTE: Indicates supplementary information needed to fully complete an instruction.
2
ABOUT THIS MANUAL
WARNING
Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death.
!
CAUTION
Denotes an instruction which, if not followed, may severely damage the unit and/or its components.
Venmar Ventilation Inc. or vänEE Canada warrants to the original consumer purchaser of its products, that such products will be guaranteed against all manufacturing defects and defective material for a period of three (3) years and a lifetime warranty on the heat recovery core (used under normal conditions).
THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. VENMAR VENTILATION INC. OR vänEE CANADA WILL NOT BE HELD RESPONSIBLE FOR ANY CLAIMS OVER THE ORIGINAL PURCHASE PRICE OF A FURNACE AIR EXCHANGER WITH HEAT RECOVERY, NOR HELD RESPONSIBLE FOR SUBSEQUENT DAMAGE OR INCIDENT.
During the period stated above, Venmar Ventilation Inc. or vänEE Canada will, at its opinion, repair or replace, without charge, any product or part which is found to be defective under normal use and service. This warranty does not cover a) normal maintenance and service, b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repairs made by other than Venmar Ventilation Inc or vänEE Canada, or c) a faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the 3-year period as specified for the express warranty. Some states or provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
VENMAR VENTILATION INC. OR vänEE CANADA'S OBLIGATION TO REPAIR OR REPLACE AT VENMAR OR vänEE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. VENMAR OR vänEE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. SOME STATES OR PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
This warranty gives you specific legal rights and you may also have other rights, which vary from state or province to another. This warranty supersedes all prior warranties.
To contact Venmar Ventilation Inc. or vänEE Canada warranty service call 1-800-567-3855 in Canada and United States.
In order to qualify for a warranty claim, the owner of a Furnace Air Exchanger with heat recovery must have the model and serial number along with a proof of the original purchase date. At the time of requesting service, describe the nature of any defect in the product or part.
In case of discrepancies between the english version of the warranty and the french version, the english version will prevail.
WARRANTY
1.0 SERVICE . . . . . . . . . . . . . . . . . . . . . . . . .4
1.1 Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.2 Parts Ordering Chart . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.0 TECHNICAL DATA . . . . . . . . . . . . . . . . . . . .4
2.1 Air Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.2 Performance Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
2.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
2.4 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.0 TYPICAL INSTALLATION . . . . . . . . . . . . . . . .6
4.0 INSTALLATION . . . . . . . . . . . . . . . . . . . . . .6
4.1 Locating and Mounting the Unit . . . . . . . . . . . . . . . . . .6
4.2 Connecting Ducts to the Unit . . . . . . . . . . . . . . . . . . . . .7
4.3 Installing Exterior Hoods . . . . . . . . . . . . . . . . . . . . . . . .7
4.4 Connecting the Drain . . . . . . . . . . . . . . . . . . . . . . . . . . .8
5.0 AIR FLOW BALANCING . . . . . . . . . . . . . . . . .9
6.0 Y
OUR UNIT . . . . . . . . . . . . . . . . . . . . . .11
6.1 Unit Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
6.2 Heat Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
6.3 During Cold Weather . . . . . . . . . . . . . . . . . . . . . . . . . .11
7.0 HOW TO OPERATE THE UNIT . . . . . . . . . . . . .12
7.1 Instructions Regarding Wall Control . . . . . . . . . . . . . .12
7.2 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
8.0 MAINTENANCE . . . . . . . . . . . . . . . . . . . . .13
8.1 Every Three Months . . . . . . . . . . . . . . . . . . . . . . . . . . .13
9.0 TROUBLESHOOTING . . . . . . . . . . . . . . . . . .14
3
TABLE OF CONTENTS
1.1 SERVICE PARTS
4
1.0
SERVICE
1.2 PARTS ORDERING CHART
Number
1.
2.
3.
Part Description Basic Filter Heat Recovery Core Damper Motor
Part Number
04432
04433 Canada/ 04455 US
04434
VL0004
2 2
1
1
3
NOTE: Unit in normal position. Can also be installed upside down.
FAE115M,
uFAE115M & vFAE115M
FAE115,
uFAE115 & vFAE115
2.0 T
ECHNICAL
D
ATA
2.1 AIR DISTRIBUTION
VF0014
STALE AIR
FROM HOUSE
FRESH AIR FROM OUTSIDE
FRESH AIR TO HOUSE
STALE AIR TO OUTSIDE
The Figure 1 illustrates the air flow inside units (all models).
Figure 1
5
These following curves illustrate the air volume through the units for a typical installation. A typical installation is close to an exterior wall, in order to shorten the insulated duct length. On the warm air side (between the unit and the furnace), use steel rigid ducts. It is strongly recommended to minimize the number of elbows to ease air flow. See Section 3.0 and 4.0 for more details.
2.2 PERFORMANCE CHART
0.00
0.10
0.20
0.30
5040 60 80 100 1209070
Flows (cfm)
Pressure (in. water gauge)
VG0031A
Stale air Fresh air
0.05
0.15
0.25
110
2.3 DIMENSIONS
VK0028
22.562”
(573 mm)
27.250”
(692 mm)
1.500’’
(38 mm)
2.225”
(57 mm)
20.000”
(508 mm)
14.500”
(368 mm)
6.000”
(152 mm)
NOTE: Typical illustration; dimensions are the same for all models.
* For models FAE115M, uFAE115M and vFAE115M only.
Weight 35.3 lbs (16 kg) 40.6 lbs (18.4 kg) Port diameter 6 inches (152 mm) 6 inches (152 mm) Drain diameter 1/2 inch (12 mm) 1/2 inch (12 mm) Installation Chains (provided with the unit) Chains (provided with the unit) Electrical supply* 24 Volts, AC 24 Volts, AC Power consumption* 6 Watts 6 Watts
Models
FAE115 & FAE115M
uFAE115 & uFAE115M
vFAE115 & vFAE115M
2.4 SPECIFICATIONS